  1. root@hostname-ubuntu-01:~# cd /opt/noc
  2. root@hostname-ubuntu-01:/opt/noc# ./noc script --debug get_version "TestEltex" 2021-03-02 17:19:06,320 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: None: 'pattern_more' '^---MORE---' pattern must be of binary type. Support for text values will be removed in NOC 20.2
  3. warnings.warn(
  4.  
  5. 2021-03-02 20:19:07,353 [noc.core.ioloop.util] Setting up asyncio event loop pol icy
  6. 2021-03-02 20:19:07,353 [noc.core.ioloop.util] Setting up default event loop
  7. 2021-03-02 20:19:07,353 [asyncio] Using selector: EpollSelector
  8. 2021-03-02 20:19:07,354 [root] Starting DCS runner thread
  9. 2021-03-02 20:19:07,354 [asyncio] Using selector: EpollSelector
  10. 2021-03-02 20:19:07,355 [root] DCS runner thread is ready
  11. 2021-03-02 20:19:07,355 [root] Starting DCS consul://consul:8500/noc
  12. 2021-03-02 20:19:07,566 [noc.core.dcs.base] Resolve near service postgres
  13. 2021-03-02 20:19:07,567 [noc.core.http.client] HTTP GET http://consul:8500/v1/he alth/service/postgres?passing=1&near=_agent
  14. 2021-03-02 20:19:07,573 [noc.core.http.client] HTTP Response 200
  15. 2021-03-02 20:19:07,574 [noc.core.dcs.base] Resolved near service postgres to [' 172.16.99.124:5432']
  16. 2021-03-02 20:19:08,576 [noc.main.models.textindex] Adding FTS index for ip.vrf
  17. 2021-03-02 20:19:08,835 [noc.core.cache.base] Using cache backend: noc.core.cach e.mongo.MongoCache
  18. 2021-03-02 20:19:08,945 [noc.main.models.doccategory] Registering Capability
  19. 2021-03-02 20:19:08,946 [noc.main.models.doccategory] Registering MetricType
  20. 2021-03-02 20:19:09,026 [noc.main.models.doccategory] Registering ConnectionType
  21. 2021-03-02 20:19:09,033 [noc.main.models.doccategory] Registering ObjectModel
  22. 2021-03-02 20:19:09,137 [noc.main.models.textindex] Adding FTS index for sa.mana gedobject
  23. 2021-03-02 20:19:09,166 [asyncio] Using selector: EpollSelector
  24. 2021-03-02 20:19:09,167 [noc.core.dcs.base] [mongo] Starting resolver (near=Fals e)
  25. 2021-03-02 20:19:09,167 [noc.core.dcs.base] [mongo] Requesting changes from inde x 0
  26. 2021-03-02 20:19:09,167 [noc.core.http.client] HTTP GET http://consul:8500/v1/he alth/service/mongo?passing=1
  27. 2021-03-02 20:19:09,169 [noc.core.http.client] HTTP Response 200
  28. 2021-03-02 20:19:09,169 [noc.core.dcs.base] [mongo] Index changed 0 -> 142749. A pplying changes
  29. 2021-03-02 20:19:09,170 [noc.core.dcs.base] [mongo] Set active services to: mong o: 172.16.99.124:27017
  30. 2021-03-02 20:19:09,170 [noc.core.dcs.base] [mongo] Stopping resolver
  31. 2021-03-02 20:19:09,171 [noc.core.mongo.connection] Connecting to MongoDB {'db': 'noc', 'username': 'noc', 'password': '********', 'authentication_source': 'noc ', 'replicaSet': 'noc', 'readPreference': 'secondaryPreferred', 'maxIdleTimeMS': 60000, 'host': 'mongodb://noc:********@172.16.99.124:27017/noc'}
  32. 2021-03-02 20:19:09,245 [noc.core.loader.base] [script] Loading script Eltex.MES .get_version
  33. 2021-03-02 20:19:09,271 [noc.core.loader.base] [profile] Loading profile Eltex.M ES
  34. 2021-03-02 20:19:09,277 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: Eltex.MES: 'pattern_more' '^More: <space>, Quit: q, One line: <return>$' p attern must be of binary type. Support for text values will be removed in NOC 20 .2
  35. warnings.warn(
  36.  
  37. 2021-03-02 20:19:09,278 [py.warnings] /opt/noc/core/profile/base.py:78: UserWarn ing: Eltex.MES: 'pattern_more' ' ' command must be of binary type. Support for t ext values will be removed in NOC 20.2
  38. warnings.warn(
  39.  
  40. 2021-03-02 20:19:09,278 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: Eltex.MES: 'pattern_more' '\\[Yes/press any key for no\\]' pattern must be of binary type. Support for text values will be removed in NOC 20.2
  41. warnings.warn(
  42.  
  43. 2021-03-02 20:19:09,278 [py.warnings] /opt/noc/core/profile/base.py:78: UserWarn ing: Eltex.MES: 'pattern_more' 'Y' command must be of binary type. Support for t ext values will be removed in NOC 20.2
  44. warnings.warn(
  45.  
  46. 2021-03-02 20:19:09,278 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: Eltex.MES: 'pattern_more' '<return>, Quit: q or <ctrl>' pattern must be of binary type. Support for text values will be removed in NOC 20.2
  47. warnings.warn(
  48.  
  49. 2021-03-02 20:19:09,278 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: Eltex.MES: 'pattern_more' 'q or <ctrl>+z' pattern must be of binary type. S upport for text values will be removed in NOC 20.2
  50. warnings.warn(
  51.  
  52. 2021-03-02 20:19:09,278 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: Eltex.MES: 'pattern_more' 'Overwrite file \\[startup-config\\].... \\(Y\\/N \\)' pattern must be of binary type. Support for text values will be removed in NOC 20.2
  53. warnings.warn(
  54.  
  55. 2021-03-02 20:19:09,279 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: Eltex.MES: 'pattern_more' 'Would you like to continue \\? \\(Y\\/N\\)\\[N\\ ]' pattern must be of binary type. Support for text values will be removed in NO C 20.2
  56. warnings.warn(
  57.  
  58. 2021-03-02 20:19:09,279 [py.warnings] /opt/noc/core/profile/base.py:72: UserWarn ing: Eltex.MES: 'pattern_more' 'Clear Logging File \\? \\(Y\\/N\\)\\[N\\]' patte rn must be of binary type. Support for text values will be removed in NOC 20.2
  59. warnings.warn(
  60.  
  61. 2021-03-02 20:19:09,282 [script] [Eltex.MES.get_version|172.16.99.97] Running. I nput arguments: {}, timeout 3600
  62. 2021-03-02 20:19:09,283 [script] [Eltex.MES.get_version|172.16.99.97] Open telne t CLI
  63. 2021-03-02 20:19:09,293 [script] [Eltex.MES.get_version|172.16.99.97] Disable pa ging
  64. 2021-03-02 20:19:09,293 [asyncio] Using selector: EpollSelector
  65. 2021-03-02 20:19:09,294 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C onnecting 172.16.99.97
  66. 2021-03-02 20:19:09,294 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting TCP NODELAY
  67. 2021-03-02 20:19:09,294 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S ettings KEEPALIVE
  68. 2021-03-02 20:19:09,294 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting TCP KEEPIDLE to 10
  69. 2021-03-02 20:19:09,294 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting TCP KEEPINTVL to 10
  70. 2021-03-02 20:19:09,294 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting TCP KEEPCNT to 3
  71. 2021-03-02 20:19:09,296 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C onnected
  72. 2021-03-02 20:19:09,296 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <start>
  73. 2021-03-02 20:19:09,297 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 50s, error=CLIStartTimeout
  74. 2021-03-02 20:19:09,299 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived DO SGA
  75. 2021-03-02 20:19:09,299 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end WILL SGA
  76. 2021-03-02 20:19:09,302 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived WILL SGA
  77. 2021-03-02 20:19:09,302 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end DO SGA
  78. 2021-03-02 20:19:09,306 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived DO ECHO
  79. 2021-03-02 20:19:09,306 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end WILL ECHO
  80. 2021-03-02 20:19:09,306 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived WILL ECHO
  81. 2021-03-02 20:19:09,306 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end DO ECHO
  82. 2021-03-02 20:19:09,332 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  83. 2021-03-02 20:19:09,373 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\r\n\r\n'
  84. 2021-03-02 20:19:09,390 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  85. 2021-03-02 20:19:09,391 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'User Name:'
  86. 2021-03-02 20:19:09,392 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'([Uu]ser ?[Nn]ame|[Ll]ogin): ?'
  87. 2021-03-02 20:19:09,392 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <username>
  88. 2021-03-02 20:19:09,392 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'ss\n'
  89. 2021-03-02 20:19:09,392 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 30s, error=CLIUsernameTimeout
  90. 2021-03-02 20:19:09,395 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's'
  91. 2021-03-02 20:19:09,437 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's\r\n\rPassword:'
  92. 2021-03-02 20:19:09,438 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'[Pp]ass[Ww]ord: ?'
  93. 2021-03-02 20:19:09,438 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <password>
  94. 2021-03-02 20:19:09,438 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'ss\n'
  95. 2021-03-02 20:19:09,438 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 30s, error=CLIPasswordTimeout
  96. 2021-03-02 20:19:09,440 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'*'
  97. 2021-03-02 20:19:09,485 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'*\r\n\r\r\n\r\nsw_IT#'
  98. 2021-03-02 20:19:09,486 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b"^(?P<hostname>[A-Za-z0-9-_ \\:\\.\\*\\'\\,\\(\\)\\/]+)?(?:\\(config[^\\) ]*\\))?#"
  99. 2021-03-02 20:19:09,486 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  100. 2021-03-02 20:19:09,486 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R efining pattern prompt to b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  101. 2021-03-02 20:19:09,486 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  102. 2021-03-02 20:19:09,486 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'terminal datadump\n'
  103. 2021-03-02 20:19:09,490 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b't'
  104. 2021-03-02 20:19:09,533 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'erminal datadump\r\n\rsw_IT#'
  105. 2021-03-02 20:19:09,534 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  106. 2021-03-02 20:19:09,534 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  107. 2021-03-02 20:19:09,534 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  108. 2021-03-02 20:19:09,534 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C ommand: b'terminal datadump'
  109. terminal datadump
  110.  
  111. 2021-03-02 20:19:09,535 [asyncio] Using selector: EpollSelector
  112. 2021-03-02 20:19:09,535 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'show unit\n'
  113. 2021-03-02 20:19:09,537 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's'
  114. 2021-03-02 20:19:09,581 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'how unit\r\n\r% Unrecognized command\r\nsw_IT#'
  115. 2021-03-02 20:19:09,582 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  116. 2021-03-02 20:19:09,582 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  117. 2021-03-02 20:19:09,582 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  118. 2021-03-02 20:19:09,582 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C ommand: b'show unit'
  119. show unit
  120. % Unrecognized command
  121.  
  122. 2021-03-02 20:19:09,583 [asyncio] Using selector: EpollSelector
  123. 2021-03-02 20:19:09,583 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'show stack\n'
  124. 2021-03-02 20:19:09,585 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's'
  125. 2021-03-02 20:19:09,631 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'how stack\r\n\r\r\nTopology is Chain'
  126. 2021-03-02 20:19:09,633 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  127. 2021-03-02 20:19:09,651 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  128. 2021-03-02 20:19:09,654 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'Unit Id MAC Address Role '
  129. 2021-03-02 20:19:09,670 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  130. 2021-03-02 20:19:09,674 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'------- ------------------- -------- '
  131. 2021-03-02 20:19:09,690 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  132. 2021-03-02 20:19:09,695 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' 1 e8:28:31:32:31:40 master '
  133. 2021-03-02 20:19:09,720 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  134. 2021-03-02 20:19:09,743 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  135. 2021-03-02 20:19:09,745 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'sw_IT#'
  136. 2021-03-02 20:19:09,746 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  137. 2021-03-02 20:19:09,746 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  138. 2021-03-02 20:19:09,746 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  139. 2021-03-02 20:19:09,746 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C ommand: b'show stack'
  140. show stack
  141.  
  142. Topology is Chain
  143.  
  144. Unit Id MAC Address Role
  145. ------- ------------------- --------
  146. 1 e8:28:31:32:31:40 master
  147.  
  148.  
  149. 2021-03-02 20:19:09,747 [asyncio] Using selector: EpollSelector
  150. 2021-03-02 20:19:09,747 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'show system unit 1\n'
  151. 2021-03-02 20:19:09,751 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's'
  152. 2021-03-02 20:19:09,789 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'how system unit 1\r\n\rSystem Description: MES2 324 AC 28-port 1G/10G Managed Switch\r\nSystem Up Time (days,hour:min:sec): 25,02:59:18'
  153. 2021-03-02 20:19:09,801 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  154. 2021-03-02 20:19:09,845 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'System Contact: \r\nSystem Na me: sw_IT\r\nSystem Location: sw-IT'
  155. 2021-03-02 20:19:09,860 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  156. 2021-03-02 20:19:09,863 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'System MAC Address: e8:28:c'
  157. 2021-03-02 20:19:09,864 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'1:36:31:40'
  158. 2021-03-02 20:19:09,881 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  159. 2021-03-02 20:19:09,883 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'System Object ID: 1.3.6.1'
  160. 2021-03-02 20:19:09,884 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'.4.1.35265.1.76'
  161. 2021-03-02 20:19:09,901 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  162. 2021-03-02 20:19:09,902 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'Reset-Button: enable'
  163. 2021-03-02 20:19:09,920 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  164. 2021-03-02 20:19:09,942 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  165. 2021-03-02 20:19:09,944 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'Unit Fans Status '
  166. 2021-03-02 20:19:09,960 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  167. 2021-03-02 20:19:09,962 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'---- -------------------------------------'
  168. 2021-03-02 20:19:09,980 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  169. 2021-03-02 20:19:09,985 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' 1 Fans status is N/A '
  170. 2021-03-02 20:19:10,011 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  171. 2021-03-02 20:19:10,031 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  172. 2021-03-02 20:19:10,034 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'Unit Temperature (Celsius) Status '
  173. 2021-03-02 20:19:10,050 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  174. 2021-03-02 20:19:10,055 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'---- --------------------- ------- '
  175. 2021-03-02 20:19:10,082 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  176. 2021-03-02 20:19:10,084 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' 1 44 OK '
  177. 2021-03-02 20:19:10,111 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  178. 2021-03-02 20:19:10,131 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  179. 2021-03-02 20:19:10,133 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'sw_IT#'
  180. 2021-03-02 20:19:10,133 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  181. 2021-03-02 20:19:10,133 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  182. 2021-03-02 20:19:10,133 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  183. 2021-03-02 20:19:10,133 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C ommand: b'show system unit 1'
  184. show system unit 1
  185. System Description: MES2324 AC 28-port 1G/10G Managed Swit ch
  186. System Up Time (days,hour:min:sec): 25,02:59:18
  187. System Contact:
  188. System Name: sw_IT
  189. System Location: sw-IT
  190. System MAC Address: e8:28:31:32:31:40
  191. System Object ID: 1.3.6.1.4.1.35265.1.76
  192. Reset-Button: enable
  193.  
  194. Unit Fans Status
  195. ---- -------------------------------------
  196. 1 Fans status is N/A
  197.  
  198. Unit Temperature (Celsius) Status
  199. ---- --------------------- -------
  200. 1 44 OK
  201.  
  202.  
  203. 2021-03-02 20:19:10,134 [asyncio] Using selector: EpollSelector
  204. 2021-03-02 20:19:10,134 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'show version unit 1\n'
  205. 2021-03-02 20:19:10,137 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's'
  206. 2021-03-02 20:19:10,140 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'how '
  207. 2021-03-02 20:19:10,141 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b've'
  208. 2021-03-02 20:19:10,150 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'rsion unit 1\r\n\r'
  209. 2021-03-02 20:19:10,170 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'% Wrong number of parameters or invalid range, si'
  210. 2021-03-02 20:19:10,189 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'ze or characters entered\r\nsw_IT#'
  211. 2021-03-02 20:19:10,190 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  212. 2021-03-02 20:19:10,190 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  213. 2021-03-02 20:19:10,190 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  214. 2021-03-02 20:19:10,190 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C ommand: b'show version unit 1'
  215. show version unit 1
  216. % Wrong number of parameters or invalid range, size or characters entered
  217.  
  218. 2021-03-02 20:19:10,192 [asyncio] Using selector: EpollSelector
  219. 2021-03-02 20:19:10,192 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'show version\n'
  220. 2021-03-02 20:19:10,195 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's'
  221. 2021-03-02 20:19:10,220 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'how version\r\n\rActive-image: flash://system/images/_image1.bin'
  222. 2021-03-02 20:19:10,230 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  223. 2021-03-02 20:19:10,278 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Version: 4.0.13\r\n Commit: f0e0150c\r\n Build: 1 (master)'
  224. 2021-03-02 20:19:10,291 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  225. 2021-03-02 20:19:10,293 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' MD5 Digest: 35e8f93c9b104239a39265afa81342f7'
  226. 2021-03-02 20:19:10,310 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  227. 2021-03-02 20:19:10,312 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Date: 28-Aug-2019'
  228. 2021-03-02 20:19:10,331 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  229. 2021-03-02 20:19:10,332 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Time: 17:07:22'
  230. 2021-03-02 20:19:10,350 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  231. 2021-03-02 20:19:10,352 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'Inactive-image: flash://system/images/image1.bin'
  232. 2021-03-02 20:19:10,370 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  233. 2021-03-02 20:19:10,372 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Version: 4.0.13'
  234. 2021-03-02 20:19:10,390 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  235. 2021-03-02 20:19:10,392 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Commit: f0e0150c'
  236. 2021-03-02 20:19:10,411 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  237. 2021-03-02 20:19:10,413 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Build: 1 (master)'
  238. 2021-03-02 20:19:10,430 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  239. 2021-03-02 20:19:10,433 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' MD5 Digest: 35e8f93c9b104239a39265afa81342f7'
  240. 2021-03-02 20:19:10,450 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  241. 2021-03-02 20:19:10,455 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Date: 28-Aug-2019'
  242. 2021-03-02 20:19:10,470 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  243. 2021-03-02 20:19:10,472 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b' Time: 17:07:22'
  244. 2021-03-02 20:19:10,492 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  245. 2021-03-02 20:19:10,494 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'sw_IT#'
  246. 2021-03-02 20:19:10,494 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  247. 2021-03-02 20:19:10,494 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  248. 2021-03-02 20:19:10,494 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  249. 2021-03-02 20:19:10,494 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C ommand: b'show version'
  250. show version
  251. Active-image: flash://system/images/_image1.bin
  252. Version: 4.0.13
  253. Commit: f0e0150c
  254. Build: 1 (master)
  255. MD5 Digest: 35e8f93c9b104239a39265afa81342f7
  256. Date: 28-Aug-2019
  257. Time: 17:07:22
  258. Inactive-image: flash://system/images/image1.bin
  259. Version: 4.0.13
  260. Commit: f0e0150c
  261. Build: 1 (master)
  262. MD5 Digest: 35e8f93c9b104239a39265afa81342f7
  263. Date: 28-Aug-2019
  264. Time: 17:07:22
  265.  
  266. 2021-03-02 20:19:10,495 [asyncio] Using selector: EpollSelector
  267. 2021-03-02 20:19:10,495 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S end: b'show system id unit 1\n'
  268. 2021-03-02 20:19:10,498 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b's'
  269. 2021-03-02 20:19:10,499 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'ho'
  270. 2021-03-02 20:19:10,509 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'w system id unit 1\r\n\rMAC address : e8:28:31:32:31:40'
  271. 2021-03-02 20:19:10,532 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\nHardware version : 03.01.03'
  272. 2021-03-02 20:19:10,550 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  273. 2021-03-02 20:19:10,552 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'Serial number : ES2A015753'
  274. 2021-03-02 20:19:10,571 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'\r\n'
  275. 2021-03-02 20:19:10,573 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] R eceived: b'sw_IT#'
  276. 2021-03-02 20:19:10,573 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] M atch: b'^sw_IT?(?:\\(config[^\\)]*\\))?#'
  277. 2021-03-02 20:19:10,574 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C hanging state to <prompt>
  278. 2021-03-02 20:19:10,574 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] S etting timeout: 3600s, error=CLIConnectionReset
  279. 2021-03-02 20:19:10,574 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C ommand: b'show system id unit 1'
  280. show system id unit 1
  281. MAC address : e8:28:31:32:31:40
  282. Hardware version : 03.01.03
  283. Serial number : ES2A015753
  284.  
  285. 2021-03-02 20:19:10,575 [script] [Eltex.MES.get_version|172.16.99.97] [telnet] C losing stream
  286. 2021-03-02 20:19:10,575 [script] [Eltex.MES.get_version|172.16.99.97] Result: {' vendor': 'Eltex', 'platform': 'MES-2324', 'version': '4.0.13', 'image': '_image1 .bin', 'attributes': {'Serial Number': 'ES2A015753'}}
  287. 2021-03-02 20:19:10,576 [script] [Eltex.MES.get_version|172.16.99.97] Complete ( 1293.12ms)
  288. {'vendor': 'Eltex', 'platform': 'MES-2324', 'version': '4.0.13', 'image': '_imag e1.bin', 'attributes': {'Serial Number': 'ES2A015753'}}
  289. root@hostname-ubuntu-01:/opt/noc#