NealzE

config.g

Jul 8th, 2019
203
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 3.70 KB | None | 0 0
  1. ; Configuration file for Duet WiFi (firmware version 1.21)
  2. ; executed by the firmware on start-up
  3. ;
  4. ; generated by RepRapFirmware Configuration Tool v2 on Thu Jun 13 2019 23:35:42 GMT+0200 (Mitteleuropäische Sommerzeit)
  5.  
  6. ; General preferences
  7. G90 ; Send absolute coordinates...
  8. M83 ; ...but relative extruder moves
  9. M665 R250 L450 B185 H410.500 ; Set delta radius, diagonal rod length, printable radius and homed height
  10. M666 X0 Y0 Z0 ; Put your endstop adjustments here, or let auto calibration find them
  11.  
  12. ; Network
  13. M550 P"Predator" ; Set machine name
  14. M552 P192.168.0.180 S1 ; Enable network and set IP address
  15. M553 P255.255.255.0 ; Set netmask
  16. M554 P192.168.0.1 ; Set gateway
  17. M586 P0 S1 ; Enable HTTP
  18. M586 P1 S1 ; Disable FTP
  19. M586 P2 S1 ; Disable Telnet
  20.  
  21. ; Drives
  22. M569 P0 S0 ; Physical drive 0 goes forwards
  23. M569 P1 S0 ; Physical drive 1 goes forwards
  24. M569 P2 S0 ; Physical drive 2 goes forwards
  25. M569 P3 S0 ; Physical drive 3 goes forwards
  26. M569 P4 S0 ; Physical drive 3 goes forwards
  27. M350 X16 Y16 Z16 E16:16 I1 ; Configure microstepping with interpolation
  28. M92 X200.00 Y200.00 Z200.00
  29. M92 E2585.0844:2585.0844 ; Set steps per mm
  30. M566 X600.00 Y600.00 Z600.00 E60.00:60.00 ; Set maximum instantaneous speed changes (mm/min)
  31. M203 X18000.00 Y18000.00 Z18000.00 E3600.00:3600.00 ; Set maximum speeds (mm/min)
  32. M201 X900.00 Y900.00 Z900.00 E240.00:240.00 ; Set accelerations (mm/s^2)
  33. M906 X1100.00 Y1100.00 Z1100.00 E600.00:600.00 I30 ; Set motor currents (mA) and motor idle factor in per cent
  34. M84 S30 ; Set idle timeout
  35.  
  36. ; Axis Limits
  37. M208 Z0 S1 ; Set minimum Z
  38.  
  39. ; Endstops
  40. M574 X2 Y2 Z2 S1 ; Set active high endstops
  41.  
  42. ; Z-Probe
  43. M558 P8 R0.4 H5 F1200 T6000 ; Set Z probe type to effector and the dive height + speeds
  44.  
  45. M558 H10 ;*** Remove this line after delta calibration has been done and new delta parameters have been saved
  46. G31 P100 X0 Y0 Z-0.00 ; Set Z probe trigger value, offset and trigger height
  47. M557 R180 S20 ; Define mesh grid
  48.  
  49. ; Heaters
  50. M305 P0 T100000 B4725 C7.060000e-8 R4700 ; Set thermistor + ADC parameters for heater 0
  51. M143 H0 S120 ; Set temperature limit for heater 0 to 120C
  52. M305 P1 B4725 C7.060000e-8 ; Set thermistor + ADC parameters for heater 1
  53. M143 H1 S280 ; Set temperature limit for heater 1 to 280C
  54.  
  55. ; Fans
  56. M106 L0.1 P0 S0 I0 F100 H-1 C"Print Cooling" ; Set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off
  57. M106 P1 S1 I0 F100 H1 T45 C"Heatsink" ; Set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on
  58.  
  59.  
  60. ; Tools
  61. M563 S"V6" P0 D1 H1 F0 ; Define tool 0
  62. G10 P0 X0 Y0 Z0 ; Set tool 0 axis offsets
  63. G10 P0 R0 S0 ; Set initial tool 0 active and standby temperatures to 0C
  64.  
  65. M572 D1 S0.2 ; Pressure Advance
  66. ; Automatic saving after power loss is not enabled
  67.  
  68.  
  69. ;### enable use of sys/config-override.g###
  70. M501 ; Load saved parameters from non-volatile memory
  71.  
  72. ; Miscellaneous
  73. T0 ; Select first tool
Advertisement