- LOGGING DATA STARTED
- Static Position for galvs is:
- pitch 24800
- roll 32950
- 14:08 - Cold Start Coordinates
- X1594
- Y2540
- TempSensors:
- CH0 = Ambient = approx 20.25 C
- CH1 = Motor
- Ch2 = Block
- 14:11 - Started Aggressive Scan
- 15:26 - Stopped Aggressive Scan
- CH0 = 21.62
- CH1 = 22.04
- CH2 = 21.59
- Pointed to Static Position pitch/roll, new centroid coordinates are:
- X1525 um
- Y2600 um
- 16:44 - Bryan Messing
- Static Position for galvs is:
- pitch 24800
- roll 32950
- Bryan turned off Galvs....will keep off for 30 minutes. Then power back on and check where galvs point
- 17:02
- Galv Beam Centroid
- X1493.5
- Y2606.0
- Mirror Beam Centroid
- X4990.7 um
- Y2700.5 um
- --------------------------------------------------------------------
- --------------------------------------------------------------------
- 20200220 Morning - galvs cold turn on, point to same pitch/roll
- Galv Beam Centroid
- X1604 um
- Y2498 um
- Mirror Beam Centroid
- X4982
- Y2712
- HEATER TEST
- RTDs, QuadCell, BeamGage Recroding
- Re-positioned Static Centroid Cursors on BeamGage Software based on new "Cold Start" Galv startup with these pitch/roll coordinates:
- pitch 24800
- roll 32950
- Initial Galv Beam Centroids:
- X1604 um
- Y2509 um
- 14:12 ish - Heater turned on @9.00V
- 14:30 - both RTDs still rising. CH1 at 23.8 C. CH2 at 24.5 C. Ambient is 20.25 C. Galv Beam walking in both axis (300-400 urad). The static mirror pointing unchanged.
- 14:50 - Both RTDs still rising (now much slower). CH1 at 24.5 C. CH2 at 25.12 C. Galv Beam still walking. 500 urad in X. 450 urad in Y. Far far far outer rings of energy are beginning to go off screen and impacting the centroid calculation very slightly (maybe 5-10 um).
- 15:10 - Turning off heater strip now. Ending Temps are CH1 at 24.70 C, CH2 at 25.38 C, Ambient at 20.46 C.
- New Galv Beam Centroids:
- X1030 um (delta from Cold start = 574 urad)
- Y2985 um (delta from Cold start = 476 urad)
- 15:30 - CH1 at 22.13 C. CH2 at 21.82 C. Ambient 20.43 C. Galvs still walking further away (but much much slower)
- 16:20 - CH1 at 21.46 C. CH2 at 21.08 C. Ambient 20.33 C. Galvs HOLDING position
- New Galv Beam Centroids:
- X960 um (delta from Cold start = 644 urad)
- Y2975 um (delta from Cold start = 466 urad)
- LEFT Setup ON overnight.....to see if Galvs snap back to their Initial Centroid locations
- --------------------------------------------------------------------
- --------------------------------------------------------------------
- 20200221
- 08:35 - Checking position of galvs
- X1285 um (delta from Cold start = 319 urad)
- Y2745 um (delta from Cold start = 236 urad)
- 08:45 - Turned off Galvs to let cool down in preperation to repeat yesterday's HEATER TEST