  1. smartctl 7.0 2018-12-30 r4883 [x86_64-linux-5.2.9-zen1-1-zen] (local build)
  2. Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Seagate Samsung SpinPoint M8 (AF)
  6. Device Model: ST1000LM024 HN-M101MBB
  7. Serial Number: S32XJ9HF718315
  8. LU WWN Device Id: 5 0004cf 20d89edb9
  9. Firmware Version: 2BA30001
  10. User Capacity: 1 000 204 886 016 bytes [1,00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Rotation Rate: 5400 rpm
  13. Form Factor: 2.5 inches
  14. Device is: In smartctl database [for details use: -P show]
  15. ATA Version is: ATA8-ACS T13/1699-D revision 6
  16. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  17. Local Time is: Wed Oct 16 13:25:24 2019 +07
  18. SMART support is: Available - device has SMART capability.
  19. SMART support is: Enabled
  20.  
  21. === START OF READ SMART DATA SECTION ===
  22. SMART overall-health self-assessment test result: PASSED
  23.  
  24. General SMART Values:
  25. Offline data collection status: (0x00) Offline data collection activity
  26. was never started.
  27. Auto Offline Data Collection: Disabled.
  28. Self-test execution status: ( 121) The previous self-test completed having
  29. the read element of the test failed.
  30. Total time to complete Offline
  31. data collection: (13080) seconds.
  32. Offline data collection
  33. capabilities: (0x5b) SMART execute Offline immediate.
  34. Auto Offline data collection on/off support.
  35. Suspend Offline collection upon new
  36. command.
  37. Offline surface scan supported.
  38. Self-test supported.
  39. No Conveyance Self-test supported.
  40. Selective Self-test supported.
  41. SMART capabilities: (0x0003) Saves SMART data before entering
  42. power-saving mode.
  43. Supports SMART auto save timer.
  44. Error logging capability: (0x01) Error logging supported.
  45. General Purpose Logging supported.
  46. Short self-test routine
  47. recommended polling time: ( 2) minutes.
  48. Extended self-test routine
  49. recommended polling time: ( 218) minutes.
  50. SCT capabilities: (0x003f) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 1754
  59. 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
  60. 3 Spin_Up_Time 0x0023 092 081 025 Pre-fail Always - 2588
  61. 4 Start_Stop_Count 0x0032 096 096 000 Old_age Always - 4551
  62. 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
  63. 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
  64. 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
  65. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 18509
  66. 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
  67. 12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4561
  68. 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 368
  69. 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
  70. 194 Temperature_Celsius 0x0002 064 058 000 Old_age Always - 34 (Min/Max 18/42)
  71. 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
  72. 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
  73. 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 9
  74. 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
  75. 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0
  76. 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 75851
  77. 223 Load_Retry_Count 0x0032 092 092 000 Old_age Always - 8574
  78. 225 Load_Cycle_Count 0x0032 051 051 000 Old_age Always - 501714
  79.  
  80. SMART Error Log Version: 1
  81. ATA Error Count: 30 (device log contains only the most recent five errors)
  82. CR = Command Register [HEX]
  83. FR = Features Register [HEX]
  84. SC = Sector Count Register [HEX]
  85. SN = Sector Number Register [HEX]
  86. CL = Cylinder Low Register [HEX]
  87. CH = Cylinder High Register [HEX]
  88. DH = Device/Head Register [HEX]
  89. DC = Device Command Register [HEX]
  90. ER = Error register [HEX]
  91. ST = Status register [HEX]
  92. Powered_Up_Time is measured from power on, and printed as
  93. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  94. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  95.  
  96. Error 30 occurred at disk power-on lifetime: 18505 hours (771 days + 1 hours)
  97. When the command that caused the error occurred, the device was active or idle.
  98.  
  99. After command completion occurred, registers were:
  100. ER ST SC SN CL CH DH
  101. -- -- -- -- -- -- --
  102. 40 51 08 90 87 ca e6 Error: UNC 8 sectors at LBA = 0x06ca8790 = 113936272
  103.  
  104. Commands leading to the command that caused the error were:
  105. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  106. -- -- -- -- -- -- -- -- ---------------- --------------------
  107. c8 00 08 90 87 ca e6 08 00:00:03.925 READ DMA
  108. 27 00 00 00 00 00 e0 08 00:00:03.925 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  109. ec 00 00 00 00 00 a0 08 00:00:03.925 IDENTIFY DEVICE
  110. ef 03 46 00 00 00 a0 08 00:00:03.925 SET FEATURES [Set transfer mode]
  111. 27 00 00 00 00 00 e0 08 00:00:03.925 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  112.  
  113. Error 29 occurred at disk power-on lifetime: 18505 hours (771 days + 1 hours)
  114. When the command that caused the error occurred, the device was active or idle.
  115.  
  116. After command completion occurred, registers were:
  117. ER ST SC SN CL CH DH
  118. -- -- -- -- -- -- --
  119. 40 51 08 88 87 ca e6 Error: UNC 8 sectors at LBA = 0x06ca8788 = 113936264
  120.  
  121. Commands leading to the command that caused the error were:
  122. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  123. -- -- -- -- -- -- -- -- ---------------- --------------------
  124. c8 00 08 88 87 ca e6 08 00:00:03.923 READ DMA
  125. c8 00 08 80 87 ca e6 08 00:00:03.923 READ DMA
  126. c8 00 08 78 87 ca e6 08 00:00:03.923 READ DMA
  127. c8 00 08 70 87 ca e6 08 00:00:03.923 READ DMA
  128. c8 00 08 68 87 ca e6 08 00:00:03.923 READ DMA
  129.  
  130. Error 28 occurred at disk power-on lifetime: 18505 hours (771 days + 1 hours)
  131. When the command that caused the error occurred, the device was active or idle.
  132.  
  133. After command completion occurred, registers were:
  134. ER ST SC SN CL CH DH
  135. -- -- -- -- -- -- --
  136. 40 51 08 48 06 24 e0 Error: UNC 8 sectors at LBA = 0x00240648 = 2360904
  137.  
  138. Commands leading to the command that caused the error were:
  139. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  140. -- -- -- -- -- -- -- -- ---------------- --------------------
  141. c8 00 08 48 06 24 e0 08 00:00:00.991 READ DMA
  142. 27 00 00 00 00 00 e0 08 00:00:00.991 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  143. ec 00 00 00 00 00 a0 08 00:00:00.991 IDENTIFY DEVICE
  144. ef 03 46 00 00 00 a0 08 00:00:00.991 SET FEATURES [Set transfer mode]
  145. 27 00 00 00 00 00 e0 08 00:00:00.991 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  146.  
  147. Error 27 occurred at disk power-on lifetime: 18505 hours (771 days + 1 hours)
  148. When the command that caused the error occurred, the device was active or idle.
  149.  
  150. After command completion occurred, registers were:
  151. ER ST SC SN CL CH DH
  152. -- -- -- -- -- -- --
  153. 40 51 08 48 06 24 e0 Error: UNC 8 sectors at LBA = 0x00240648 = 2360904
  154.  
  155. Commands leading to the command that caused the error were:
  156. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  157. -- -- -- -- -- -- -- -- ---------------- --------------------
  158. c8 00 08 48 06 24 e0 08 00:00:00.988 READ DMA
  159. c8 00 08 40 06 24 e0 08 00:00:00.988 READ DMA
  160. c8 00 08 38 06 24 e0 08 00:00:00.988 READ DMA
  161. 27 00 00 00 00 00 e0 08 00:00:00.988 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  162. ec 00 00 00 00 00 a0 08 00:00:00.988 IDENTIFY DEVICE
  163.  
  164. Error 26 occurred at disk power-on lifetime: 18505 hours (771 days + 1 hours)
  165. When the command that caused the error occurred, the device was active or idle.
  166.  
  167. After command completion occurred, registers were:
  168. ER ST SC SN CL CH DH
  169. -- -- -- -- -- -- --
  170. 40 51 08 30 06 24 e0 Error: UNC 8 sectors at LBA = 0x00240630 = 2360880
  171.  
  172. Commands leading to the command that caused the error were:
  173. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  174. -- -- -- -- -- -- -- -- ---------------- --------------------
  175. c8 00 08 30 06 24 e0 08 00:00:00.986 READ DMA
  176. 27 00 00 00 00 00 e0 08 00:00:00.986 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  177. ec 00 00 00 00 00 a0 08 00:00:00.986 IDENTIFY DEVICE
  178. ef 03 46 00 00 00 a0 08 00:00:00.986 SET FEATURES [Set transfer mode]
  179. 27 00 00 00 00 00 e0 08 00:00:00.986 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  180.  
  181. SMART Self-test log structure revision number 1
  182. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  183. # 1 Short offline Completed: read failure 90% 18499 2360880
  184. # 2 Extended offline Completed: read failure 90% 18497 2360856
  185. # 3 Short offline Completed: read failure 90% 18497 2360880
  186. # 4 Offline Completed without error 00% 0 -
  187. # 5 Offline Completed without error 00% 0 -
  188.  
  189. SMART Selective self-test log data structure revision number 0
  190. Note: revision number not 1 implies that no selective self-test has ever been run
  191. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  192. 1 0 0 Completed_read_failure [90% left] (0-65535)
  193. 2 0 0 Not_testing
  194. 3 0 0 Not_testing
  195. 4 0 0 Not_testing
  196. 5 0 0 Not_testing
  197. Selective self-test flags (0x0):
  198. After scanning selected spans, do NOT read-scan remainder of disk.
  199. If Selective self-test is pending on power-up, resume after 0 minute delay.