- [FileInfo]
- CreatedBy=Someone
- ModifiedBy=Someone
- Description=Electronic datasheet for Keya 4830-1E
- CreationTime=11:18AM
- CreationDate=06-15-2018
- ModificationTime=11:18AM
- ModificationDate=06-15-2018
- FileName=keya.eds
- FileVersion=1
- FileRevision=0
- EDSVersion=4.0
- [DeviceInfo]
- VendorName=Keya
- VendorNumber=0
- ProductName=KYDBL 4830-1E
- ProductNumber=0
- RevisionNumber=1
- BaudRate_10=0
- BaudRate_20=0
- BaudRate_50=0
- BaudRate_125=1
- BaudRate_250=1
- BaudRate_500=1
- BaudRate_800=0
- BaudRate_1000=0
- SimpleBootUpMaster=0
- SimpleBootUpSlave=1
- Granularity=8
- DynamicChannelsSupported=0
- CompactPDO=0
- GroupMessaging=0
- NrOfRXPDO=0
- NrOfTXPDO=0
- LSS_Supported=0
- [DummyUsage]
- Dummy0001=0
- Dummy0002=0
- Dummy0003=0
- Dummy0004=0
- Dummy0005=0
- Dummy0006=0
- Dummy0007=0
- [Comments]
- Lines=0
- [MandatoryObjects]
- SupportedObjects=3
- 1=0x1000
- 2=0x1001
- 3=0x1018
- [1000]
- ParameterName=Device Type
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- PDOMapping=0
- [1001]
- ParameterName=Error Register
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- PDOMapping=0
- [1018]
- ParameterName=Identity Object
- ObjectType=0x9
- SubNumber=5
- [1018sub0]
- ParameterName=Number of entries
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=4
- PDOMapping=0
- LowLimit=1
- HighLimit=4
- [1018sub1]
- ParameterName=Vendor Id
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- DefaultValue=0
- PDOMapping=0
- [1018sub2]
- ParameterName=Product Code
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- DefaultValue=0
- PDOMapping=0
- [1018sub3]
- ParameterName=Revision number
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- DefaultValue=1
- PDOMapping=0
- [1018sub4]
- ParameterName=Serial number
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- PDOMapping=0
- [OptionalObjects]
- SupportedObjects=5
- 1=0x1002
- 2=0x6040
- 3=0x6041
- 4=0x6060
- 5=0x6061
- [1002]
- ParameterName=Manufacturer Status Register
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- PDOMapping=0
- [6040]
- ParameterName=Controlword
- ObjectType=0x7
- DataType=0x0006
- AccessType=rw
- PDOMapping=0
- [6041]
- ParameterName=Statusword
- ObjectType=0x7
- DataType=0x0006
- AccessType=ro
- PDOMapping=0
- [6060]
- ParameterName=Modes_of_operation
- ObjectType=0x7
- DataType=0x0002
- AccessType=rw
- [6061]
- ParameterName=Modes_of_operation_display
- ObjectType=0x7
- DataType=0x0002
- AccessType=ro
- [ManufacturerObjects]
- SupportedObjects=26
- 1=0x2000
- 2=0x2001
- 3=0x2002
- 4=0x2003
- 5=0x2006
- 6=0x2007
- 7=0x200C
- 8=0x200D
- 9=0x2017
- 10=0x2100
- 11=0x2101
- 12=0x2103
- 13=0x2107
- 14=0x2108
- 15=0x2109
- 16=0x210A
- 17=0x210C
- 18=0x210D
- 19=0x210E
- 20=0x210F
- 21=0x2111
- 22=0x2112
- 23=0x2113
- 24=0x2119
- 25=0x2121
- 26=0x2C0E
- [2000]
- ParameterName=Set motor speed
- ObjectType=0x8
- SubNumber=3
- [2000sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2000sub1]
- ParameterName=Set motor speed ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=wo
- PDOMapping=0
- [2000sub2]
- ParameterName=Set motor speed ch2
- ObjectType=0x7
- DataType=0x0003
- AccessType=wo
- PDOMapping=0
- [2001]
- ParameterName=Set position command
- ObjectType=0x8
- SubNumber=3
- [2001sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2001sub1]
- ParameterName=Set position command ch1
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [2001sub2]
- ParameterName=Set position command ch2
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [2002]
- ParameterName=Set position speed
- ObjectType=0x8
- SubNumber=3
- [2002sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2002sub1]
- ParameterName=Set position speed ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=wo
- PDOMapping=0
- [2002sub2]
- ParameterName=Set position speed ch2
- ObjectType=0x7
- DataType=0x0003
- AccessType=wo
- PDOMapping=0
- [2003]
- ParameterName=Set encodeur counter
- ObjectType=0x8
- SubNumber=3
- [2003sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2003sub1]
- ParameterName=Set encodeur counter ch1
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [2003sub2]
- ParameterName=Set encodeur counter ch2
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [2006]
- ParameterName=Set acceleration
- ObjectType=0x8
- SubNumber=3
- [2006sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2006sub1]
- ParameterName=Set acceleration ch1
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [2006sub2]
- ParameterName=Set acceleration ch2
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [2007]
- ParameterName=Set deceleration
- ObjectType=0x8
- SubNumber=3
- [2007sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2007sub1]
- ParameterName=Set deceleration ch1
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [2007sub2]
- ParameterName=Set deceleration ch2
- ObjectType=0x7
- DataType=0x0004
- AccessType=wo
- PDOMapping=0
- [200C]
- ParameterName=Emergency shutdown
- ObjectType=0x7
- DataType=0x0005
- AccessType=wo
- PDOMapping=0
- [200D]
- ParameterName=Release shutdown
- ObjectType=0x7
- DataType=0x0005
- AccessType=wo
- PDOMapping=0
- [2017]
- ParameterName=Save config to flash
- ObjectType=0x7
- DataType=0x0005
- AccessType=wo
- PDOMapping=0
- [2100]
- ParameterName=Read motor amps
- ObjectType=0x8
- SubNumber=3
- [2100sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2100sub1]
- ParameterName=Read motor amps ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2100sub2]
- ParameterName=Read motor amps ch2
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2101]
- ParameterName=Read Actual Motor Command
- ObjectType=0x8
- SubNumber=3
- [2101sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2101sub1]
- ParameterName=Read Actual Motor Command ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2101sub2]
- ParameterName=Read Actual Motor Command ch2
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2103]
- ParameterName=Read Encoder Motor Speed
- ObjectType=0x8
- SubNumber=3
- [2103sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2103sub1]
- ParameterName=Read Encoder Motor Speed ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2103sub2]
- ParameterName=Read Encoder Motor Speed ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2107]
- ParameterName=Read Encoder Motor Speed as 1/1000 of max
- ObjectType=0x8
- SubNumber=3
- [2107sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2107sub1]
- ParameterName=Read Encoder Motor Speed as 1/1000 of max ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2107sub2]
- ParameterName=Read Encoder Motor Speed as 1/1000 of max ch2
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [2108]
- ParameterName=Read Encoder Count Relative
- ObjectType=0x8
- SubNumber=3
- [2108sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2108sub1]
- ParameterName=Read Encoder Count Relative ch1
- ObjectType=0x7
- DataType=0x0004
- AccessType=ro
- PDOMapping=0
- [2108sub2]
- ParameterName=Read Encoder Count Relative ch2
- ObjectType=0x7
- DataType=0x0004
- AccessType=ro
- PDOMapping=0
- [2109]
- ParameterName=Read Brushless Count Relative
- ObjectType=0x8
- SubNumber=3
- [2109sub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2109sub1]
- ParameterName=Read Brushless Count Relative ch1
- ObjectType=0x7
- DataType=0x0004
- AccessType=ro
- PDOMapping=0
- [2109sub2]
- ParameterName=Read Brushless Count Relative ch2
- ObjectType=0x7
- DataType=0x0004
- AccessType=ro
- PDOMapping=0
- [210A]
- ParameterName=Read BL Motor Speed in RPM
- ObjectType=0x8
- SubNumber=3
- [210Asub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [210Asub1]
- ParameterName=Read BL Motor Speed in RPM ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [210Asub2]
- ParameterName=Read BL Motor Speed in RPM ch2
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [210C]
- ParameterName=Read Battery Amps
- ObjectType=0x8
- SubNumber=3
- [210Csub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [210Csub1]
- ParameterName=Read Battery Amps ch1
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [210Csub2]
- ParameterName=Read Battery Amps ch2
- ObjectType=0x7
- DataType=0x0003
- AccessType=ro
- PDOMapping=0
- [210D]
- ParameterName=Read Internal Voltage
- ObjectType=0x8
- SubNumber=4
- [210Dsub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=3
- PDOMapping=0
- [210Dsub1]
- ParameterName=Read Internal Voltage (V int)
- ObjectType=0x7
- DataType=0x0006
- AccessType=ro
- PDOMapping=0
- [210Dsub2]
- ParameterName=Read Internal Valtage (V)
- ObjectType=0x7
- DataType=0x0006
- AccessType=ro
- PDOMapping=0
- [210Dsub3]
- ParameterName=Read Internal Valtage (mV)
- ObjectType=0x7
- DataType=0x0006
- AccessType=ro
- PDOMapping=0
- [210E]
- ParameterName=R Digital Inputs
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- [210F]
- ParameterName=Read Case & Internal Temperature
- ObjectType=0x8
- SubNumber=4
- [210Fsub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=3
- PDOMapping=0
- [210Fsub1]
- ParameterName=Read Case & Internal Temperature (MCU Temperature)
- ObjectType=0x7
- DataType=0x0002
- AccessType=ro
- PDOMapping=0
- [210Fsub2]
- ParameterName=Read Case & Internal Temperature (ch.1)
- ObjectType=0x7
- DataType=0x0002
- AccessType=ro
- PDOMapping=0
- [210Fsub3]
- ParameterName=Read Case & Internal Temperature (ch.2)
- ObjectType=0x7
- DataType=0x0002
- AccessType=ro
- PDOMapping=0
- [2111]
- ParameterName=Read Status Flags
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- PDOMapping=0
- [2112]
- ParameterName=Read Fault Flags
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- PDOMapping=0
- [2113]
- ParameterName=Read Current Digital Outputs
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- PDOMapping=0
- [2119]
- ParameterName=Read Time
- ObjectType=0x7
- DataType=0x0007
- AccessType=ro
- [2121]
- ParameterName=Read Motor Status
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- PDOMapping=0
- [2C0E]
- ParameterName=Set motor command
- ObjectType=0x8
- SubNumber=3
- [2C0Esub0]
- ParameterName=NrOfObjects
- ObjectType=0x7
- DataType=0x0005
- AccessType=ro
- DefaultValue=2
- PDOMapping=0
- [2C0Esub1]
- ParameterName=Object 2C0E_sub1
- ObjectType=0x7
- DataType=0x0005
- AccessType=wo
- PDOMapping=0
- [2C0Esub2]
- ParameterName=Object 2C0E_sub2
- ObjectType=0x7
- DataType=0x0005
- AccessType=wo
- PDOMapping=0