- 2017-10-16 22:02:40.857 [DEBUG] [nternal.ModbusGenericBindingProvider] - Item 'itemName' is of type 'DimmerItem'. Please make sure that transformation is in place to convert the polled data to a format understood by the item. Furthermore, make sure that commands are converted to DecimalType or any command accepted by Switch, Contact or Number items.
- 2017-10-16 22:02:40.859 [DEBUG] [.modbus.internal.ModbusBindingConfig] - Since '[' in item 'Dimmer1' config string '>[slave2:1],<[slave4:1]', trying to parse it using extended parser
- 2017-10-16 22:02:40.891 [DEBUG] [.modbus.internal.ModbusBindingConfig] - Parsed IOConnection (read=false) for item 'Dimmer1': ItemIOConnection@111f44bd[slaveName=slave2,index=1,type=COMMAND,trigger=default,transformation=Transformation@7420f970[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]
- 2017-10-16 22:02:40.892 [DEBUG] [.modbus.internal.ModbusBindingConfig] - Parsed IOConnection (read=true) for item 'Dimmer1': ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]
- 2017-10-16 22:02:40.892 [DEBUG] [.modbus.internal.ModbusBindingConfig] - item 'Dimmer1' parsed
- 2017-10-16 22:02:40.893 [DEBUG] [org.openhab.binding.modbus ] - ServiceEvent REGISTERED - {org.openhab.model.item.binding.BindingConfigReader, org.openhab.binding.modbus.ModbusBindingProvider}={component.name=org.openhab.binding.modbus.genericbindingprovider, component.id=170, service.id=296, service.bundleid=180, service.scope=bundle} - org.openhab.binding.modbus
- 2017-10-16 22:02:40.913 [DEBUG] [org.openhab.binding.modbus ] - ServiceEvent REGISTERED - {org.osgi.service.cm.ManagedService, org.osgi.service.event.EventHandler}={event.topics=openhab/*, service.pid=org.openhab.modbus, component.name=org.openhab.binding.modbus, component.id=171, service.id=298, service.bundleid=180, service.scope=bundle} - org.openhab.binding.modbus
- 2017-10-16 22:02:40.956 [DEBUG] [inding.modbus.internal.ModbusBinding] - modbusSlave 'slave1' instanciated
- 2017-10-16 22:02:40.983 [DEBUG] [inding.modbus.internal.ModbusBinding] - modbusSlave 'slave2' instanciated
- 2017-10-16 22:02:40.984 [DEBUG] [inding.modbus.internal.ModbusBinding] - modbusSlave 'slave3' instanciated
- 2017-10-16 22:02:40.996 [DEBUG] [inding.modbus.internal.ModbusBinding] - modbusSlave 'slave4' instanciated
- 2017-10-16 22:02:40.999 [WARN ] [inding.modbus.internal.ModbusBinding] - Slave slave1 (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) has different retry/connection delay (EndpointPoolConfiguration) etc. settings. Replacing EndpointPoolConfiguration@57512a6e[passivateBorrowMinMillis=60,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=0,connectTimeoutMillis=0] with EndpointPoolConfiguration@47ddfa61[passivateBorrowMinMillis=60,interConnectDelayMillis=0,connectMaxTries=50,reconnectAfterMillis=0,connectTimeoutMillis=100]
- 2017-10-16 22:02:41.007 [DEBUG] [inding.modbus.internal.ModbusBinding] - Parsed the following slave->endpoint configurations: {slave4=EndpointPoolConfiguration@6c57eba1[passivateBorrowMinMillis=60,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=0,connectTimeoutMillis=0], slave3=EndpointPoolConfiguration@538f1dfc[passivateBorrowMinMillis=60,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=0,connectTimeoutMillis=0], slave2=EndpointPoolConfiguration@57512a6e[passivateBorrowMinMillis=60,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=0,connectTimeoutMillis=0], slave1=EndpointPoolConfiguration@47ddfa61[passivateBorrowMinMillis=60,interConnectDelayMillis=0,connectMaxTries=50,reconnectAfterMillis=0,connectTimeoutMillis=100]}. If the endpoint is same, connections are shared between the instances.
- 2017-10-16 22:02:41.007 [DEBUG] [inding.modbus.internal.ModbusBinding] - Parsed the following pool configurations: {ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]=EndpointPoolConfiguration@47ddfa61[passivateBorrowMinMillis=60,interConnectDelayMillis=0,connectMaxTries=50,reconnectAfterMillis=0,connectTimeoutMillis=100]}
- 2017-10-16 22:02:41.008 [DEBUG] [inding.modbus.internal.ModbusBinding] - config looked good
- 2017-10-16 22:02:41.028 [INFO ] [b.core.service.AbstractActiveService] - Modbus Polling Service has been started
- 2017-10-16 22:02:41.036 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Created connection TCPMasterConnection@59e4f821[socket=<null>] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.039 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:41.046 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49686]] -> true
- 2017-10-16 22:02:41.046 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49686]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 16 ms
- 2017-10-16 22:02:41.046 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@36e39963 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 0) to read data
- 2017-10-16 22:02:41.046 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 1: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@36e39963
- 2017-10-16 22:02:41.065 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 1
- 2017-10-16 22:02:41.066 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 01 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:41.066 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49686]] -> true
- 2017-10-16 22:02:41.066 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49686]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:41.067 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49686]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 22ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:41.067 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49686]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.068 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.069 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:41.105 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 36ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49686]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:41.105 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:41.109 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49687]] -> true
- 2017-10-16 22:02:41.109 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49687]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 40 ms
- 2017-10-16 22:02:41.110 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@d1ef56 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 1) to read data
- 2017-10-16 22:02:41.110 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 2: net.wimpi.modbus.msg.ReadInputRegistersRequest@d1ef56
- 2017-10-16 22:02:41.125 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 2
- 2017-10-16 22:02:41.125 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 02 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:41.126 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49687]] -> true
- 2017-10-16 22:02:41.126 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49687]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:41.126 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49687]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 18ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:41.127 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49687]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.127 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.127 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:41.128 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=true) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:41.168 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 37ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49687]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:41.168 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:41.172 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49688]] -> true
- 2017-10-16 22:02:41.172 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49688]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 41 ms
- 2017-10-16 22:02:41.173 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@851e1a0 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 2) to read data
- 2017-10-16 22:02:41.173 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 3: net.wimpi.modbus.msg.ReadCoilsRequest@851e1a0
- 2017-10-16 22:02:41.186 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 3
- 2017-10-16 22:02:41.187 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 03 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:41.187 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49688]] -> true
- 2017-10-16 22:02:41.187 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49688]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:41.188 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49688]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:41.188 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49688]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.188 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.189 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:41.233 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49688]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:41.234 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:41.237 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49689]] -> true
- 2017-10-16 22:02:41.237 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49689]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:41.237 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@36d25785 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 3) to read data
- 2017-10-16 22:02:41.237 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 4: net.wimpi.modbus.msg.ReadInputDiscretesRequest@36d25785
- 2017-10-16 22:02:41.252 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 4
- 2017-10-16 22:02:41.252 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 04 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:41.252 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49689]] -> true
- 2017-10-16 22:02:41.253 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49689]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:41.253 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49689]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:41.254 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49689]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.254 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:41.254 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:42.255 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:42.257 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49690]] -> true
- 2017-10-16 22:02:42.258 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49690]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 3 ms
- 2017-10-16 22:02:42.258 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@ad6fb61 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 4) to read data
- 2017-10-16 22:02:42.258 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 5: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@ad6fb61
- 2017-10-16 22:02:42.272 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 5
- 2017-10-16 22:02:42.272 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 05 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:42.272 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49690]] -> true
- 2017-10-16 22:02:42.273 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49690]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:42.273 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49690]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:42.274 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49690]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.274 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.274 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:42.317 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49690]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:42.317 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:42.320 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49691]] -> true
- 2017-10-16 22:02:42.320 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49691]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:42.320 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@3831c0d5 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 5) to read data
- 2017-10-16 22:02:42.320 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 6: net.wimpi.modbus.msg.ReadInputRegistersRequest@3831c0d5
- 2017-10-16 22:02:42.334 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 6
- 2017-10-16 22:02:42.334 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 06 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:42.335 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49691]] -> true
- 2017-10-16 22:02:42.335 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49691]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:42.335 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49691]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:42.336 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49691]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.336 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.336 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:42.336 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:42.380 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49691]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:42.380 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:42.385 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49692]] -> true
- 2017-10-16 22:02:42.385 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49692]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:42.386 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@43ff91cf using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 6) to read data
- 2017-10-16 22:02:42.386 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 7: net.wimpi.modbus.msg.ReadCoilsRequest@43ff91cf
- 2017-10-16 22:02:42.400 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 7
- 2017-10-16 22:02:42.400 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 07 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:42.401 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49692]] -> true
- 2017-10-16 22:02:42.401 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49692]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:42.401 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49692]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:42.402 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49692]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.402 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.402 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:42.445 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49692]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:42.446 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:42.450 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49694]] -> true
- 2017-10-16 22:02:42.450 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49694]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:42.450 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@3c75f671 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 7) to read data
- 2017-10-16 22:02:42.450 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 8: net.wimpi.modbus.msg.ReadInputDiscretesRequest@3c75f671
- 2017-10-16 22:02:42.464 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 8
- 2017-10-16 22:02:42.465 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 08 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:42.465 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49694]] -> true
- 2017-10-16 22:02:42.465 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49694]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:42.465 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49694]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:42.466 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49694]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.466 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:42.466 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:43.470 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:43.475 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49698]] -> true
- 2017-10-16 22:02:43.475 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49698]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 9 ms
- 2017-10-16 22:02:43.475 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@675e5aa using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 8) to read data
- 2017-10-16 22:02:43.475 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 9: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@675e5aa
- 2017-10-16 22:02:43.490 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 9
- 2017-10-16 22:02:43.490 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 09 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:43.490 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49698]] -> true
- 2017-10-16 22:02:43.491 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49698]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:43.491 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49698]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:43.491 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49698]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.492 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.492 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:43.534 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 42ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49698]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:43.534 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:43.537 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49699]] -> true
- 2017-10-16 22:02:43.537 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49699]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 45 ms
- 2017-10-16 22:02:43.537 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@3abfc0ec using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 9) to read data
- 2017-10-16 22:02:43.538 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 10: net.wimpi.modbus.msg.ReadInputRegistersRequest@3abfc0ec
- 2017-10-16 22:02:43.552 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 10
- 2017-10-16 22:02:43.552 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 0a 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:43.552 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49699]] -> true
- 2017-10-16 22:02:43.553 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49699]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:43.553 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49699]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:43.553 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49699]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.554 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.554 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:43.554 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:43.598 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49699]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:43.598 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:43.601 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49701]] -> true
- 2017-10-16 22:02:43.601 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49701]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:43.601 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@71c27d2b using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 10) to read data
- 2017-10-16 22:02:43.601 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 11: net.wimpi.modbus.msg.ReadCoilsRequest@71c27d2b
- 2017-10-16 22:02:43.615 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 11
- 2017-10-16 22:02:43.615 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 0b 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:43.616 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49701]] -> true
- 2017-10-16 22:02:43.616 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49701]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:43.616 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49701]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:43.617 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49701]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.617 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.617 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:43.660 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49701]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:43.661 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:43.665 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49702]] -> true
- 2017-10-16 22:02:43.665 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49702]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:43.666 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@4f40e3fb using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 11) to read data
- 2017-10-16 22:02:43.666 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 12: net.wimpi.modbus.msg.ReadInputDiscretesRequest@4f40e3fb
- 2017-10-16 22:02:43.680 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 12
- 2017-10-16 22:02:43.680 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 0c 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:43.680 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49702]] -> true
- 2017-10-16 22:02:43.681 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49702]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:43.681 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49702]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:43.681 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49702]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.681 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:43.681 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:44.682 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:44.685 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49705]] -> true
- 2017-10-16 22:02:44.685 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49705]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 3 ms
- 2017-10-16 22:02:44.685 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@69a714c9 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 12) to read data
- 2017-10-16 22:02:44.686 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 13: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@69a714c9
- 2017-10-16 22:02:44.700 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 13
- 2017-10-16 22:02:44.700 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 0d 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:44.701 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49705]] -> true
- 2017-10-16 22:02:44.701 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49705]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:44.701 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49705]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:44.701 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49705]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.702 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.702 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:44.745 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49705]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:44.745 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:44.748 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49706]] -> true
- 2017-10-16 22:02:44.748 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49706]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:44.749 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@4d36fd23 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 13) to read data
- 2017-10-16 22:02:44.749 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 14: net.wimpi.modbus.msg.ReadInputRegistersRequest@4d36fd23
- 2017-10-16 22:02:44.764 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 14
- 2017-10-16 22:02:44.765 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 0e 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:44.765 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49706]] -> true
- 2017-10-16 22:02:44.765 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49706]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:44.766 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49706]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:44.766 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49706]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.766 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.767 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:44.767 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:44.808 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 41ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49706]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:44.808 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:44.812 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49707]] -> true
- 2017-10-16 22:02:44.812 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49707]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 45 ms
- 2017-10-16 22:02:44.812 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@672e57ae using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 14) to read data
- 2017-10-16 22:02:44.812 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 15: net.wimpi.modbus.msg.ReadCoilsRequest@672e57ae
- 2017-10-16 22:02:44.826 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 15
- 2017-10-16 22:02:44.826 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 0f 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:44.826 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49707]] -> true
- 2017-10-16 22:02:44.827 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49707]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:44.827 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49707]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:44.827 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49707]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.828 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.828 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:44.872 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49707]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:44.872 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:44.875 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49708]] -> true
- 2017-10-16 22:02:44.875 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49708]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:44.875 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@1469a622 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 15) to read data
- 2017-10-16 22:02:44.876 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 16: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1469a622
- 2017-10-16 22:02:44.890 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 16
- 2017-10-16 22:02:44.890 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 10 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:44.890 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49708]] -> true
- 2017-10-16 22:02:44.891 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49708]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:44.891 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49708]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:44.891 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49708]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.891 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:44.892 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:45.527 [TRACE] [inding.modbus.internal.ModbusBinding] - Received command '62' for item 'Dimmer1'
- 2017-10-16 22:02:45.527 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' write connections for command 62: [ItemIOConnection@111f44bd[slaveName=slave2,index=1,type=COMMAND,trigger=default,transformation=Transformation@7420f970[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:45.532 [TRACE] [inding.modbus.internal.ModbusBinding] - Executing command '62' (transformed from '62' using transformation Transformation@7420f970[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>]) using item 'Dimmer1' IO connection ItemIOConnection@111f44bd[slaveName=slave2,index=1,type=COMMAND,trigger=default,transformation=Transformation@7420f970[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default] (writeIndex=Optional[22], previouslyPolledState={})
- 2017-10-16 22:02:45.532 [DEBUG] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): FC6 ref=32769 value=62
- 2017-10-16 22:02:45.533 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:45.537 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49709]] -> true
- 2017-10-16 22:02:45.537 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49709]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 5 ms
- 2017-10-16 22:02:45.538 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.WriteSingleRegisterRequest@3713d681 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 16) to write data
- 2017-10-16 22:02:45.538 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 17: net.wimpi.modbus.msg.WriteSingleRegisterRequest@3713d681
- 2017-10-16 22:02:45.551 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 17
- 2017-10-16 22:02:45.551 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for write (FC=6) 00 11 00 00 00 06 01 06 80 01 00 3e
- 2017-10-16 22:02:45.551 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49709]] -> true
- 2017-10-16 22:02:45.552 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49709]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:45.552 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49709]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:45.552 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49709]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:45.553 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:45.893 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:45.895 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49710]] -> true
- 2017-10-16 22:02:45.896 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49710]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 3 ms
- 2017-10-16 22:02:45.896 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@4730bf28 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 17) to read data
- 2017-10-16 22:02:45.896 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 18: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@4730bf28
- 2017-10-16 22:02:45.910 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 18
- 2017-10-16 22:02:45.910 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 12 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:45.910 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49710]] -> true
- 2017-10-16 22:02:45.910 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49710]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:45.911 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49710]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:45.911 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49710]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:45.911 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:45.911 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:45.955 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49710]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:45.955 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:45.958 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49711]] -> true
- 2017-10-16 22:02:45.958 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49711]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:45.958 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@14feec21 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 18) to read data
- 2017-10-16 22:02:45.959 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 19: net.wimpi.modbus.msg.ReadInputRegistersRequest@14feec21
- 2017-10-16 22:02:45.974 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 19
- 2017-10-16 22:02:45.975 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 13 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:45.975 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49711]] -> true
- 2017-10-16 22:02:45.975 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49711]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:45.975 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49711]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:45.976 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49711]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:45.976 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:45.976 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:45.976 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=true) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:46.018 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 41ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49711]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:46.018 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:46.020 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49712]] -> true
- 2017-10-16 22:02:46.021 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49712]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 44 ms
- 2017-10-16 22:02:46.021 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@342e46e3 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 19) to read data
- 2017-10-16 22:02:46.021 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 20: net.wimpi.modbus.msg.ReadCoilsRequest@342e46e3
- 2017-10-16 22:02:46.035 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 20
- 2017-10-16 22:02:46.035 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 14 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:46.035 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49712]] -> true
- 2017-10-16 22:02:46.036 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49712]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:46.036 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49712]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:46.036 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49712]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:46.036 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:46.037 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:46.080 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49712]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:46.080 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:46.084 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49713]] -> true
- 2017-10-16 22:02:46.084 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49713]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:46.084 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@6240d7d5 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 20) to read data
- 2017-10-16 22:02:46.084 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 21: net.wimpi.modbus.msg.ReadInputDiscretesRequest@6240d7d5
- 2017-10-16 22:02:46.099 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 21
- 2017-10-16 22:02:46.099 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 15 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:46.099 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49713]] -> true
- 2017-10-16 22:02:46.100 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49713]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:46.100 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49713]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:46.100 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49713]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:46.101 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:46.101 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:47.102 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:47.108 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49715]] -> true
- 2017-10-16 22:02:47.108 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49715]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 6 ms
- 2017-10-16 22:02:47.108 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@7910b757 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 21) to read data
- 2017-10-16 22:02:47.108 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 22: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@7910b757
- 2017-10-16 22:02:47.122 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 22
- 2017-10-16 22:02:47.122 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 16 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:47.122 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49715]] -> true
- 2017-10-16 22:02:47.122 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49715]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:47.122 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49715]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 14ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:47.123 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49715]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.123 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.123 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:47.168 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49715]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:47.168 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:47.170 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49716]] -> true
- 2017-10-16 22:02:47.171 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49716]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:47.171 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@7933e359 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 22) to read data
- 2017-10-16 22:02:47.171 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 23: net.wimpi.modbus.msg.ReadInputRegistersRequest@7933e359
- 2017-10-16 22:02:47.185 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 23
- 2017-10-16 22:02:47.185 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 17 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:47.185 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49716]] -> true
- 2017-10-16 22:02:47.186 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49716]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:47.186 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49716]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:47.186 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49716]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.186 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.187 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:47.187 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:47.230 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49716]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:47.230 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:47.234 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49717]] -> true
- 2017-10-16 22:02:47.234 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49717]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:47.234 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@45d256fb using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 23) to read data
- 2017-10-16 22:02:47.234 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 24: net.wimpi.modbus.msg.ReadCoilsRequest@45d256fb
- 2017-10-16 22:02:47.250 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 24
- 2017-10-16 22:02:47.250 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 18 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:47.250 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49717]] -> true
- 2017-10-16 22:02:47.250 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49717]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:47.251 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49717]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:47.251 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49717]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.251 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.251 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:47.295 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49717]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:47.295 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:47.298 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49718]] -> true
- 2017-10-16 22:02:47.298 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49718]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:47.298 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@75e8ac40 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 24) to read data
- 2017-10-16 22:02:47.298 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 25: net.wimpi.modbus.msg.ReadInputDiscretesRequest@75e8ac40
- 2017-10-16 22:02:47.312 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 25
- 2017-10-16 22:02:47.312 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 19 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:47.312 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49718]] -> true
- 2017-10-16 22:02:47.313 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49718]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:47.313 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49718]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:47.313 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49718]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.313 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:47.314 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:48.314 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:48.316 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49719]] -> true
- 2017-10-16 22:02:48.316 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49719]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 2 ms
- 2017-10-16 22:02:48.316 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@3ce4080d using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 25) to read data
- 2017-10-16 22:02:48.316 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 26: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@3ce4080d
- 2017-10-16 22:02:48.330 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 26
- 2017-10-16 22:02:48.331 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 1a 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:48.331 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49719]] -> true
- 2017-10-16 22:02:48.331 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49719]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:48.331 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49719]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:48.331 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49719]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.332 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.332 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:48.376 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49719]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:48.376 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:48.379 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49720]] -> true
- 2017-10-16 22:02:48.379 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49720]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:48.379 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@2235f276 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 26) to read data
- 2017-10-16 22:02:48.379 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 27: net.wimpi.modbus.msg.ReadInputRegistersRequest@2235f276
- 2017-10-16 22:02:48.395 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 27
- 2017-10-16 22:02:48.395 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 1b 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:48.395 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49720]] -> true
- 2017-10-16 22:02:48.396 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49720]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:48.396 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49720]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:48.396 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49720]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.396 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.396 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:48.397 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:48.439 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 42ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49720]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:48.439 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:48.442 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49721]] -> true
- 2017-10-16 22:02:48.442 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49721]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 45 ms
- 2017-10-16 22:02:48.442 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@62f77568 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 27) to read data
- 2017-10-16 22:02:48.442 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 28: net.wimpi.modbus.msg.ReadCoilsRequest@62f77568
- 2017-10-16 22:02:48.456 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 28
- 2017-10-16 22:02:48.456 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 1c 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:48.456 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49721]] -> true
- 2017-10-16 22:02:48.456 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49721]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:48.457 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49721]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:48.457 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49721]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.457 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.457 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:48.502 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 45ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49721]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:48.502 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:48.505 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49722]] -> true
- 2017-10-16 22:02:48.505 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49722]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:48.505 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@309ab83 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 28) to read data
- 2017-10-16 22:02:48.505 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 29: net.wimpi.modbus.msg.ReadInputDiscretesRequest@309ab83
- 2017-10-16 22:02:48.520 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 29
- 2017-10-16 22:02:48.520 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 1d 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:48.520 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49722]] -> true
- 2017-10-16 22:02:48.520 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49722]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:48.521 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49722]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:48.521 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49722]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.521 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:48.521 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:49.522 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:49.524 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49723]] -> true
- 2017-10-16 22:02:49.524 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49723]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 2 ms
- 2017-10-16 22:02:49.524 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5936a5bb using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 29) to read data
- 2017-10-16 22:02:49.524 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 30: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5936a5bb
- 2017-10-16 22:02:49.539 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 30
- 2017-10-16 22:02:49.539 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 1e 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:49.539 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49723]] -> true
- 2017-10-16 22:02:49.539 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49723]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:49.540 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49723]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:49.540 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49723]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.540 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.540 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:49.585 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49723]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:49.585 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:49.588 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49724]] -> true
- 2017-10-16 22:02:49.588 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49724]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:49.588 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@b604737 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 30) to read data
- 2017-10-16 22:02:49.588 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 31: net.wimpi.modbus.msg.ReadInputRegistersRequest@b604737
- 2017-10-16 22:02:49.604 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 31
- 2017-10-16 22:02:49.604 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 1f 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:49.604 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49724]] -> true
- 2017-10-16 22:02:49.604 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49724]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:49.605 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49724]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:49.605 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49724]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.605 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.605 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:49.605 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:49.648 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49724]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:49.648 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:49.650 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49725]] -> true
- 2017-10-16 22:02:49.650 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49725]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 45 ms
- 2017-10-16 22:02:49.651 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@79dd2a94 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 31) to read data
- 2017-10-16 22:02:49.651 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 32: net.wimpi.modbus.msg.ReadCoilsRequest@79dd2a94
- 2017-10-16 22:02:49.664 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 32
- 2017-10-16 22:02:49.664 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 20 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:49.664 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49725]] -> true
- 2017-10-16 22:02:49.665 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49725]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:49.665 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49725]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:49.665 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49725]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.665 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.665 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:49.710 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 45ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49725]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:49.710 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:49.713 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49726]] -> true
- 2017-10-16 22:02:49.714 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49726]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 49 ms
- 2017-10-16 22:02:49.714 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@68a3c098 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 32) to read data
- 2017-10-16 22:02:49.714 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 33: net.wimpi.modbus.msg.ReadInputDiscretesRequest@68a3c098
- 2017-10-16 22:02:49.726 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 33
- 2017-10-16 22:02:49.726 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 21 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:49.726 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49726]] -> true
- 2017-10-16 22:02:49.726 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49726]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:49.726 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49726]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 13ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:49.726 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49726]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.727 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:49.727 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:50.728 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:50.730 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49727]] -> true
- 2017-10-16 22:02:50.730 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49727]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 2 ms
- 2017-10-16 22:02:50.731 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@3f206064 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 33) to read data
- 2017-10-16 22:02:50.731 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 34: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@3f206064
- 2017-10-16 22:02:50.746 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 34
- 2017-10-16 22:02:50.746 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 22 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:50.746 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49727]] -> true
- 2017-10-16 22:02:50.746 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49727]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:50.747 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49727]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:50.747 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49727]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.747 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.747 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:50.790 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49727]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:50.790 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:50.795 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49728]] -> true
- 2017-10-16 22:02:50.795 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49728]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:50.795 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@332be2d3 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 34) to read data
- 2017-10-16 22:02:50.795 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 35: net.wimpi.modbus.msg.ReadInputRegistersRequest@332be2d3
- 2017-10-16 22:02:50.809 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 35
- 2017-10-16 22:02:50.809 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 23 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:50.810 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49728]] -> true
- 2017-10-16 22:02:50.810 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49728]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:50.810 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49728]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:50.810 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49728]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.810 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.810 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:50.810 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:50.854 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49728]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:50.854 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:50.861 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49729]] -> true
- 2017-10-16 22:02:50.861 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49729]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 50 ms
- 2017-10-16 22:02:50.861 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@6bdd9ee9 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 35) to read data
- 2017-10-16 22:02:50.861 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 36: net.wimpi.modbus.msg.ReadCoilsRequest@6bdd9ee9
- 2017-10-16 22:02:50.876 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 36
- 2017-10-16 22:02:50.876 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 24 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:50.876 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49729]] -> true
- 2017-10-16 22:02:50.876 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49729]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:50.876 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49729]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:50.877 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49729]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.877 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.877 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:50.921 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49729]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:50.921 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:50.924 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49730]] -> true
- 2017-10-16 22:02:50.924 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49730]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:50.924 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@100e3329 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 36) to read data
- 2017-10-16 22:02:50.924 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 37: net.wimpi.modbus.msg.ReadInputDiscretesRequest@100e3329
- 2017-10-16 22:02:50.938 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 37
- 2017-10-16 22:02:50.938 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 25 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:50.938 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49730]] -> true
- 2017-10-16 22:02:50.938 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49730]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:50.938 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49730]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 14ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:50.938 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49730]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.939 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:50.939 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:51.940 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:51.943 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49731]] -> true
- 2017-10-16 22:02:51.944 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49731]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 4 ms
- 2017-10-16 22:02:51.944 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5798e3fb using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 37) to read data
- 2017-10-16 22:02:51.944 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 38: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5798e3fb
- 2017-10-16 22:02:51.958 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 38
- 2017-10-16 22:02:51.958 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 26 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:51.958 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49731]] -> true
- 2017-10-16 22:02:51.958 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49731]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:51.958 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49731]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:51.959 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49731]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:51.959 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:51.959 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:52.003 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49731]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:52.003 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:52.005 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49732]] -> true
- 2017-10-16 22:02:52.006 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49732]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:52.006 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@31ee3b71 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 38) to read data
- 2017-10-16 22:02:52.006 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 39: net.wimpi.modbus.msg.ReadInputRegistersRequest@31ee3b71
- 2017-10-16 22:02:52.021 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 39
- 2017-10-16 22:02:52.021 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 27 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:52.021 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49732]] -> true
- 2017-10-16 22:02:52.021 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49732]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:52.021 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49732]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:52.022 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49732]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:52.022 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:52.022 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:52.022 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:52.065 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49732]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:52.065 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:52.068 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49733]] -> true
- 2017-10-16 22:02:52.068 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49733]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:52.068 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@599a86ea using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 39) to read data
- 2017-10-16 22:02:52.068 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 40: net.wimpi.modbus.msg.ReadCoilsRequest@599a86ea
- 2017-10-16 22:02:52.084 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 40
- 2017-10-16 22:02:52.084 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 28 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:52.084 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49733]] -> true
- 2017-10-16 22:02:52.084 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49733]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:52.084 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49733]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:52.084 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49733]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:52.085 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:52.085 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:52.129 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49733]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:52.129 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:52.132 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49734]] -> true
- 2017-10-16 22:02:52.132 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49734]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:52.132 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@f08be89 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 40) to read data
- 2017-10-16 22:02:52.132 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 41: net.wimpi.modbus.msg.ReadInputDiscretesRequest@f08be89
- 2017-10-16 22:02:52.145 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 41
- 2017-10-16 22:02:52.145 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 29 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:52.146 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49734]] -> true
- 2017-10-16 22:02:52.146 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49734]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:52.146 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49734]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 14ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:52.146 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49734]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:52.146 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:52.146 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:53.147 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:53.149 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49735]] -> true
- 2017-10-16 22:02:53.149 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49735]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 2 ms
- 2017-10-16 22:02:53.149 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@229d3fc3 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 41) to read data
- 2017-10-16 22:02:53.149 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 42: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@229d3fc3
- 2017-10-16 22:02:53.164 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 42
- 2017-10-16 22:02:53.164 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 2a 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:53.164 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49735]] -> true
- 2017-10-16 22:02:53.164 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49735]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:53.164 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49735]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:53.164 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49735]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.165 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.165 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:53.210 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49735]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:53.210 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:53.214 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49736]] -> true
- 2017-10-16 22:02:53.214 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49736]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 49 ms
- 2017-10-16 22:02:53.214 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@4e7dc0c3 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 42) to read data
- 2017-10-16 22:02:53.214 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 43: net.wimpi.modbus.msg.ReadInputRegistersRequest@4e7dc0c3
- 2017-10-16 22:02:53.229 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 43
- 2017-10-16 22:02:53.230 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 2b 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:53.230 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49736]] -> true
- 2017-10-16 22:02:53.230 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49736]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:53.230 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49736]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:53.230 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49736]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.230 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.230 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:53.230 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:53.274 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49736]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:53.274 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:53.276 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49737]] -> true
- 2017-10-16 22:02:53.277 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49737]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:53.277 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@40252880 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 43) to read data
- 2017-10-16 22:02:53.277 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 44: net.wimpi.modbus.msg.ReadCoilsRequest@40252880
- 2017-10-16 22:02:53.291 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 44
- 2017-10-16 22:02:53.291 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 2c 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:53.291 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49737]] -> true
- 2017-10-16 22:02:53.291 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49737]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:53.291 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49737]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:53.292 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49737]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.292 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.292 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:53.336 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49737]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:53.336 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:53.338 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49738]] -> true
- 2017-10-16 22:02:53.338 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49738]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:53.338 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@3a3ef804 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 44) to read data
- 2017-10-16 22:02:53.339 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 45: net.wimpi.modbus.msg.ReadInputDiscretesRequest@3a3ef804
- 2017-10-16 22:02:53.353 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 45
- 2017-10-16 22:02:53.353 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 2d 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:53.353 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49738]] -> true
- 2017-10-16 22:02:53.353 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49738]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:53.354 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49738]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:53.354 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49738]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.354 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:53.354 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:54.354 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:54.356 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49739]] -> true
- 2017-10-16 22:02:54.357 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49739]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 2 ms
- 2017-10-16 22:02:54.357 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@33b31dfc using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 45) to read data
- 2017-10-16 22:02:54.357 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 46: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@33b31dfc
- 2017-10-16 22:02:54.371 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 46
- 2017-10-16 22:02:54.371 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 2e 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:54.371 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49739]] -> true
- 2017-10-16 22:02:54.371 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49739]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:54.371 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49739]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:54.372 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49739]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.372 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.372 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:54.416 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49739]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:54.416 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:54.418 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49740]] -> true
- 2017-10-16 22:02:54.418 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49740]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:54.418 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@4e97da31 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 46) to read data
- 2017-10-16 22:02:54.418 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 47: net.wimpi.modbus.msg.ReadInputRegistersRequest@4e97da31
- 2017-10-16 22:02:54.433 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 47
- 2017-10-16 22:02:54.433 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 2f 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:54.433 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49740]] -> true
- 2017-10-16 22:02:54.433 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49740]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:54.433 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49740]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:54.433 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49740]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.434 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.434 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:54.434 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:54.478 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49740]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:54.478 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:54.480 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49741]] -> true
- 2017-10-16 22:02:54.481 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49741]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:02:54.481 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@6523effc using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 47) to read data
- 2017-10-16 22:02:54.481 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 48: net.wimpi.modbus.msg.ReadCoilsRequest@6523effc
- 2017-10-16 22:02:54.494 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 48
- 2017-10-16 22:02:54.495 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 30 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:54.495 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49741]] -> true
- 2017-10-16 22:02:54.495 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49741]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:54.495 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49741]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:54.495 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49741]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.495 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.495 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:54.540 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 45ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49741]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:54.540 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:54.544 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49742]] -> true
- 2017-10-16 22:02:54.545 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49742]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 50 ms
- 2017-10-16 22:02:54.545 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@31f10bae using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 48) to read data
- 2017-10-16 22:02:54.545 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 49: net.wimpi.modbus.msg.ReadInputDiscretesRequest@31f10bae
- 2017-10-16 22:02:54.561 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 49
- 2017-10-16 22:02:54.561 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 31 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:54.561 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49742]] -> true
- 2017-10-16 22:02:54.561 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49742]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:54.561 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49742]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:54.562 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49742]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.562 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:54.562 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:55.563 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:55.566 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49743]] -> true
- 2017-10-16 22:02:55.566 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49743]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 3 ms
- 2017-10-16 22:02:55.566 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2756d785 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 49) to read data
- 2017-10-16 22:02:55.566 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 50: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@2756d785
- 2017-10-16 22:02:55.579 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 50
- 2017-10-16 22:02:55.580 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 32 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:55.580 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49743]] -> true
- 2017-10-16 22:02:55.580 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49743]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:55.580 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49743]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:55.580 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49743]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.580 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.580 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:55.625 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 45ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49743]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:55.625 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:55.628 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49744]] -> true
- 2017-10-16 22:02:55.628 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49744]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:55.628 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@6742c8ba using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 50) to read data
- 2017-10-16 22:02:55.628 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 51: net.wimpi.modbus.msg.ReadInputRegistersRequest@6742c8ba
- 2017-10-16 22:02:55.643 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 51
- 2017-10-16 22:02:55.643 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 33 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:55.643 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49744]] -> true
- 2017-10-16 22:02:55.644 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49744]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:55.644 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49744]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:55.644 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49744]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.644 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.644 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:55.644 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:55.689 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49744]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:55.689 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:55.693 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49745]] -> true
- 2017-10-16 22:02:55.693 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49745]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:02:55.693 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@2fee87ed using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 51) to read data
- 2017-10-16 22:02:55.693 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 52: net.wimpi.modbus.msg.ReadCoilsRequest@2fee87ed
- 2017-10-16 22:02:55.706 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 52
- 2017-10-16 22:02:55.706 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 34 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:55.706 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49745]] -> true
- 2017-10-16 22:02:55.706 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49745]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:55.706 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49745]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 13ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:55.706 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49745]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.706 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.707 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:55.753 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 46ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49745]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:55.753 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:55.756 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49746]] -> true
- 2017-10-16 22:02:55.756 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49746]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 49 ms
- 2017-10-16 22:02:55.756 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@388cca84 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 52) to read data
- 2017-10-16 22:02:55.756 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 53: net.wimpi.modbus.msg.ReadInputDiscretesRequest@388cca84
- 2017-10-16 22:02:55.769 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 53
- 2017-10-16 22:02:55.770 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 35 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:55.770 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49746]] -> true
- 2017-10-16 22:02:55.770 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49746]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:55.770 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49746]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 14ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:55.771 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49746]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.771 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:55.771 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:56.771 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:56.774 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49747]] -> true
- 2017-10-16 22:02:56.775 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49747]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 4 ms
- 2017-10-16 22:02:56.775 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@712b64ab using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 53) to read data
- 2017-10-16 22:02:56.775 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 54: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@712b64ab
- 2017-10-16 22:02:56.790 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 54
- 2017-10-16 22:02:56.790 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 36 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:56.790 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49747]] -> true
- 2017-10-16 22:02:56.790 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49747]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:56.791 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49747]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:56.791 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49747]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.791 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.791 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:56.835 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49747]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:56.835 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:56.837 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49748]] -> true
- 2017-10-16 22:02:56.837 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49748]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:56.837 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@30284bb8 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 54) to read data
- 2017-10-16 22:02:56.837 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 55: net.wimpi.modbus.msg.ReadInputRegistersRequest@30284bb8
- 2017-10-16 22:02:56.853 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 55
- 2017-10-16 22:02:56.854 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 37 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:56.854 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49748]] -> true
- 2017-10-16 22:02:56.854 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49748]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:56.854 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49748]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:56.854 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49748]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.854 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.854 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:56.854 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:56.897 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49748]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:56.897 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:56.900 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49749]] -> true
- 2017-10-16 22:02:56.900 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49749]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:56.900 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@3a72946a using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 55) to read data
- 2017-10-16 22:02:56.900 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 56: net.wimpi.modbus.msg.ReadCoilsRequest@3a72946a
- 2017-10-16 22:02:56.915 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 56
- 2017-10-16 22:02:56.915 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 38 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:56.915 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49749]] -> true
- 2017-10-16 22:02:56.915 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49749]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:56.915 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49749]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:56.915 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49749]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.915 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.915 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:56.960 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49749]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:56.960 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:56.964 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49750]] -> true
- 2017-10-16 22:02:56.964 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49750]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 49 ms
- 2017-10-16 22:02:56.964 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@55e68b04 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 56) to read data
- 2017-10-16 22:02:56.964 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 57: net.wimpi.modbus.msg.ReadInputDiscretesRequest@55e68b04
- 2017-10-16 22:02:56.976 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 57
- 2017-10-16 22:02:56.976 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 39 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:56.976 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49750]] -> true
- 2017-10-16 22:02:56.977 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49750]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:56.977 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49750]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 13ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:56.977 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49750]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.977 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:56.977 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:57.978 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:57.981 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49751]] -> true
- 2017-10-16 22:02:57.982 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49751]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 4 ms
- 2017-10-16 22:02:57.982 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5e4de7fb using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 57) to read data
- 2017-10-16 22:02:57.982 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 58: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5e4de7fb
- 2017-10-16 22:02:57.993 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 58
- 2017-10-16 22:02:57.993 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 3a 00 00 00 49 01 03 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:57.993 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49751]] -> true
- 2017-10-16 22:02:57.994 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49751]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:57.994 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49751]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 13ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:57.994 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49751]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:57.994 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:57.994 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:58.041 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 47ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49751]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:58.041 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:58.044 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49752]] -> true
- 2017-10-16 22:02:58.044 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49752]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 50 ms
- 2017-10-16 22:02:58.044 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@1351312e using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 58) to read data
- 2017-10-16 22:02:58.044 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 59: net.wimpi.modbus.msg.ReadInputRegistersRequest@1351312e
- 2017-10-16 22:02:58.059 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 59
- 2017-10-16 22:02:58.059 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 3b 00 00 00 49 01 04 46 00 00 00 3e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:58.059 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49752]] -> true
- 2017-10-16 22:02:58.059 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49752]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:58.059 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49752]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:58.059 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49752]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:58.059 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:58.060 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:58.060 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 62 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:58.104 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49752]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:58.104 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:58.106 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49753]] -> true
- 2017-10-16 22:02:58.106 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49753]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:58.106 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@45a5d43b using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 59) to read data
- 2017-10-16 22:02:58.106 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 60: net.wimpi.modbus.msg.ReadCoilsRequest@45a5d43b
- 2017-10-16 22:02:58.120 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 60
- 2017-10-16 22:02:58.121 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 3c 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:58.121 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49753]] -> true
- 2017-10-16 22:02:58.121 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49753]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:58.121 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49753]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:58.121 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49753]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:58.121 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:58.122 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:58.166 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49753]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:58.166 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:58.168 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49754]] -> true
- 2017-10-16 22:02:58.168 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49754]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:58.168 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@5c3c3fd5 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 60) to read data
- 2017-10-16 22:02:58.168 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 61: net.wimpi.modbus.msg.ReadInputDiscretesRequest@5c3c3fd5
- 2017-10-16 22:02:58.183 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 61
- 2017-10-16 22:02:58.183 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 3d 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:58.184 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49754]] -> true
- 2017-10-16 22:02:58.184 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49754]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:58.184 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49754]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:58.184 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49754]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:58.184 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:58.184 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:02:59.185 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:59.189 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49755]] -> true
- 2017-10-16 22:02:59.189 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49755]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 4 ms
- 2017-10-16 22:02:59.189 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@774eed8d using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 61) to read data
- 2017-10-16 22:02:59.189 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 62: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@774eed8d
- 2017-10-16 22:02:59.203 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 62
- 2017-10-16 22:02:59.204 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 3e 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:59.204 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49755]] -> true
- 2017-10-16 22:02:59.204 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49755]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:59.204 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49755]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:59.204 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49755]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.204 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.204 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:02:59.251 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 45ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49755]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:59.251 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:59.255 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49756]] -> true
- 2017-10-16 22:02:59.255 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49756]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 51 ms
- 2017-10-16 22:02:59.255 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@798f255b using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 62) to read data
- 2017-10-16 22:02:59.255 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 63: net.wimpi.modbus.msg.ReadInputRegistersRequest@798f255b
- 2017-10-16 22:02:59.271 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 63
- 2017-10-16 22:02:59.271 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 3f 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:02:59.271 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49756]] -> true
- 2017-10-16 22:02:59.271 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49756]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:59.271 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49756]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:59.272 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49756]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.272 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.272 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:02:59.272 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=true) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:02:59.315 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49756]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:59.315 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:59.318 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49757]] -> true
- 2017-10-16 22:02:59.318 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49757]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:59.318 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@6a2e068b using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 63) to read data
- 2017-10-16 22:02:59.318 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 64: net.wimpi.modbus.msg.ReadCoilsRequest@6a2e068b
- 2017-10-16 22:02:59.334 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 64
- 2017-10-16 22:02:59.334 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 40 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:02:59.334 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49757]] -> true
- 2017-10-16 22:02:59.334 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49757]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:59.334 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49757]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:59.335 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49757]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.335 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.335 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:02:59.378 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49757]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:02:59.378 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:02:59.380 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49758]] -> true
- 2017-10-16 22:02:59.381 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49758]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:02:59.381 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@2df83294 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 64) to read data
- 2017-10-16 22:02:59.381 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 65: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2df83294
- 2017-10-16 22:02:59.395 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 65
- 2017-10-16 22:02:59.395 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 41 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:02:59.395 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49758]] -> true
- 2017-10-16 22:02:59.395 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49758]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:02:59.395 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49758]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:02:59.396 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49758]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.396 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:02:59.396 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:03:00.397 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:00.400 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49759]] -> true
- 2017-10-16 22:03:00.400 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49759]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 3 ms
- 2017-10-16 22:03:00.401 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@381d21c3 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 65) to read data
- 2017-10-16 22:03:00.401 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 66: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@381d21c3
- 2017-10-16 22:03:00.414 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 66
- 2017-10-16 22:03:00.414 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 42 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:03:00.414 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49759]] -> true
- 2017-10-16 22:03:00.415 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49759]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:00.415 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49759]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:00.415 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49759]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.415 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.415 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:03:00.460 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 45ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49759]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:00.460 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:00.464 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49760]] -> true
- 2017-10-16 22:03:00.464 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49760]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 49 ms
- 2017-10-16 22:03:00.464 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@127a4127 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 66) to read data
- 2017-10-16 22:03:00.464 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 67: net.wimpi.modbus.msg.ReadInputRegistersRequest@127a4127
- 2017-10-16 22:03:00.480 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 67
- 2017-10-16 22:03:00.480 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 43 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:03:00.480 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49760]] -> true
- 2017-10-16 22:03:00.481 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49760]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:00.481 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49760]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 17ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:00.481 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49760]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.481 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.481 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:03:00.481 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:03:00.525 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 42ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49760]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:00.525 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:00.528 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49761]] -> true
- 2017-10-16 22:03:00.528 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49761]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:03:00.528 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@ae62cea using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 67) to read data
- 2017-10-16 22:03:00.528 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 68: net.wimpi.modbus.msg.ReadCoilsRequest@ae62cea
- 2017-10-16 22:03:00.542 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 68
- 2017-10-16 22:03:00.542 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 44 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:03:00.542 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49761]] -> true
- 2017-10-16 22:03:00.542 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49761]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:00.542 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49761]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 14ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:00.543 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49761]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.543 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.543 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:03:00.588 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 45ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49761]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:00.588 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:00.590 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49762]] -> true
- 2017-10-16 22:03:00.591 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49762]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 48 ms
- 2017-10-16 22:03:00.591 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@61838e60 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 68) to read data
- 2017-10-16 22:03:00.591 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 69: net.wimpi.modbus.msg.ReadInputDiscretesRequest@61838e60
- 2017-10-16 22:03:00.605 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 69
- 2017-10-16 22:03:00.605 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 45 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:03:00.605 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49762]] -> true
- 2017-10-16 22:03:00.605 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49762]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:00.605 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49762]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:00.605 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49762]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.606 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:03:00.606 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:03:01.606 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:01.609 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49763]] -> true
- 2017-10-16 22:03:01.609 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49763]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 3 ms
- 2017-10-16 22:03:01.609 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@218d9e49 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 69) to read data
- 2017-10-16 22:03:01.609 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 70: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@218d9e49
- 2017-10-16 22:03:01.624 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 70
- 2017-10-16 22:03:01.624 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 46 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:03:01.624 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49763]] -> true
- 2017-10-16 22:03:01.624 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49763]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:01.624 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49763]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:01.624 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49763]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.625 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.625 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:03:01.668 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 43ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49763]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:01.668 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:01.670 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49764]] -> true
- 2017-10-16 22:03:01.670 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49764]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 45 ms
- 2017-10-16 22:03:01.670 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@7995045d using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 70) to read data
- 2017-10-16 22:03:01.670 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 71: net.wimpi.modbus.msg.ReadInputRegistersRequest@7995045d
- 2017-10-16 22:03:01.685 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 71
- 2017-10-16 22:03:01.685 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 47 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:03:01.685 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49764]] -> true
- 2017-10-16 22:03:01.685 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49764]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:01.685 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49764]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:01.685 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49764]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.686 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.686 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:03:01.686 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:03:01.730 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49764]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:01.730 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:01.733 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49765]] -> true
- 2017-10-16 22:03:01.734 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49765]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:03:01.734 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@15352241 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 71) to read data
- 2017-10-16 22:03:01.734 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 72: net.wimpi.modbus.msg.ReadCoilsRequest@15352241
- 2017-10-16 22:03:01.748 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 72
- 2017-10-16 22:03:01.748 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 48 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:03:01.748 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49765]] -> true
- 2017-10-16 22:03:01.748 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49765]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:01.748 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49765]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:01.749 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49765]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.749 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.749 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:03:01.793 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49765]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:01.793 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:01.795 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49766]] -> true
- 2017-10-16 22:03:01.795 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49766]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 46 ms
- 2017-10-16 22:03:01.796 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@3ddd2cb using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 72) to read data
- 2017-10-16 22:03:01.796 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 73: net.wimpi.modbus.msg.ReadInputDiscretesRequest@3ddd2cb
- 2017-10-16 22:03:01.810 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 73
- 2017-10-16 22:03:01.810 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 49 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:03:01.810 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49766]] -> true
- 2017-10-16 22:03:01.811 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49766]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:01.811 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49766]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 16ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:01.811 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49766]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.811 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:03:01.811 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []
- 2017-10-16 22:03:02.812 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:02.815 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49767]] -> true
- 2017-10-16 22:03:02.815 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49767]]) for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] took 3 ms
- 2017-10-16 22:03:02.815 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5b23a202 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@6cf37a33 (global transaction id before increment 73) to read data
- 2017-10-16 22:03:02.815 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 74: net.wimpi.modbus.msg.ReadMultipleRegistersRequest@5b23a202
- 2017-10-16 22:03:02.830 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 74
- 2017-10-16 22:03:02.830 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): response for read (FC=3) 00 4a 00 00 00 49 01 03 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:03:02.830 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49767]] -> true
- 2017-10-16 22:03:02.830 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49767]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:02.830 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49767]] (endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:02.831 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49767]] for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:03:02.831 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave2): returned connection for endpoint ModbusTCPSlaveEndpoint@7087eefe[address=192.168.0.112,port=502]
- 2017-10-16 22:03:02.831 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave2: []
- 2017-10-16 22:03:02.875 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49767]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:02.875 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:02.878 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49768]] -> true
- 2017-10-16 22:03:02.878 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49768]]) for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:03:02.878 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputRegistersRequest@38a9bbd0 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@7777f9f3 (global transaction id before increment 74) to read data
- 2017-10-16 22:03:02.878 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 75: net.wimpi.modbus.msg.ReadInputRegistersRequest@38a9bbd0
- 2017-10-16 22:03:02.894 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 75
- 2017-10-16 22:03:02.895 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): response for read (FC=4) 00 4b 00 00 00 49 01 04 46 00 00 00 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
- 2017-10-16 22:03:02.895 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49768]] -> true
- 2017-10-16 22:03:02.896 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49768]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:02.896 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49768]] (endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]) age 18ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:02.896 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49768]] for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:03:02.897 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave4): returned connection for endpoint ModbusTCPSlaveEndpoint@d535fb9[address=192.168.0.112,port=502]
- 2017-10-16 22:03:02.897 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave4: [ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default]]
- 2017-10-16 22:03:02.898 [TRACE] [inding.modbus.internal.ModbusBinding] - internalUpdateItem(Register): Updating slave slave4 item Dimmer1, state 22 (changed=false) matched ItemIOConnection ItemIOConnection@16ed0bde[slaveName=slave4,index=1,type=STATE,trigger=default,transformation=Transformation@d665611[tranformation=default,transformationServiceName=<null>,transformationServiceParam=<null>],valueType=default].
- 2017-10-16 22:03:02.939 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 40ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49768]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:02.939 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:02.942 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49769]] -> true
- 2017-10-16 22:03:02.942 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49769]]) for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] took 44 ms
- 2017-10-16 22:03:02.942 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadCoilsRequest@5cda597d using transaction net.wimpi.modbus.io.ModbusTCPTransaction@39923f22 (global transaction id before increment 75) to read data
- 2017-10-16 22:03:02.942 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 76: net.wimpi.modbus.msg.ReadCoilsRequest@5cda597d
- 2017-10-16 22:03:02.955 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 76
- 2017-10-16 22:03:02.956 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): response for read (FC=1) 00 4c 00 00 00 08 01 01 05 00 00 00 00 00
- 2017-10-16 22:03:02.956 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49769]] -> true
- 2017-10-16 22:03:02.956 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49769]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:02.956 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49769]] (endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]) age 15ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:02.956 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49769]] for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:03:02.956 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave1): returned connection for endpoint ModbusTCPSlaveEndpoint@1145c44b[address=192.168.0.112,port=502]
- 2017-10-16 22:03:02.956 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave1: []
- 2017-10-16 22:03:03.001 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Waited 44ms (interConnectDelayMillis 0ms, passivateBorrowMinMillis 60ms) before connecting disconnected connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49769]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502], to allow delay between connections re-connects
- 2017-10-16 22:03:03.001 [DEBUG] [wimpi.modbus.net.TCPMasterConnection] - connect()
- 2017-10-16 22:03:03.004 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49770]] -> true
- 2017-10-16 22:03:03.004 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): borrowing connection (got TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49770]]) for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] took 47 ms
- 2017-10-16 22:03:03.004 [TRACE] [.binding.modbus.internal.ModbusSlave] - Executing modbus request net.wimpi.modbus.msg.ReadInputDiscretesRequest@778ee12 using transaction net.wimpi.modbus.io.ModbusTCPTransaction@1e910552 (global transaction id before increment 76) to read data
- 2017-10-16 22:03:03.004 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Sending request with transaction ID 77: net.wimpi.modbus.msg.ReadInputDiscretesRequest@778ee12
- 2017-10-16 22:03:03.018 [TRACE] [wimpi.modbus.io.ModbusTCPTransaction] - Received response with transaction ID 77
- 2017-10-16 22:03:03.018 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): response for read (FC=2) 00 4d 00 00 00 08 01 02 05 00 08 00 00 00
- 2017-10-16 22:03:03.018 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502] connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49770]] -> true
- 2017-10-16 22:03:03.018 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - Passivating connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49770]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]...
- 2017-10-16 22:03:03.018 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - (passivate) Connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49770]] (endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]) age 14ms is over the reconnectAfterMillis=0ms limit -> disconnecting.
- 2017-10-16 22:03:03.018 [TRACE] [ing.ModbusSlaveConnectionFactoryImpl] - ...Passivated connection TCPMasterConnection@59e4f821[socket=Socket[addr=/192.168.0.112,port=502,localport=49770]] for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:03:03.019 [TRACE] [.binding.modbus.internal.ModbusSlave] - ModbusSlave (slave3): returned connection for endpoint ModbusTCPSlaveEndpoint@2e1894ac[address=192.168.0.112,port=502]
- 2017-10-16 22:03:03.019 [TRACE] [.modbus.internal.ModbusBindingConfig] - Item 'Dimmer1' has the following read connections configured for slave slave3: []