  1. smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.4.2-arch1-1] (local build)
  2. Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Scorpio Blue Serial ATA
  6. Device Model: WDC WD2500BEVS-22UST0
  7. Serial Number: WD-WXEX07493960
  8. LU WWN Device Id: 5 0014ee 200a916c8
  9. Firmware Version: 01.01A01
  10. User Capacity: 250,059,350,016 bytes [250 GB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database 7.3/5319
  13. ATA Version is: ATA8-ACS (minor revision not indicated)
  14. Local Time is: Fri Jul 21 23:32:09 2023 CET
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x00) Offline data collection activity
  23. was never started.
  24. Auto Offline Data Collection: Disabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26. without error or no self-test has ever
  27. been run.
  28. Total time to complete Offline
  29. data collection: ( 9180) seconds.
  30. Offline data collection
  31. capabilities: (0x7b) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. Offline surface scan supported.
  36. Self-test supported.
  37. Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 2) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 110) minutes.
  48. Conveyance self-test routine
  49. recommended polling time: ( 5) minutes.
  50. SCT capabilities: (0x303f) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 372
  59. 3 Spin_Up_Time 0x0003 188 185 021 Pre-fail Always - 1600
  60. 4 Start_Stop_Count 0x0032 095 095 000 Old_age Always - 5156
  61. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x000f 100 253 051 Pre-fail Always - 0
  63. 9 Power_On_Hours 0x0032 091 091 000 Old_age Always - 6611
  64. 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
  65. 11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0
  66. 12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4677
  67. 192 Power-Off_Retract_Count 0x0032 199 199 000 Old_age Always - 1432
  68. 193 Load_Cycle_Count 0x0032 182 182 000 Old_age Always - 55579
  69. 194 Temperature_Celsius 0x0022 103 088 000 Old_age Always - 44
  70. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  71. 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 6
  72. 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0
  73. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 2
  74. 200 Multi_Zone_Error_Rate 0x0009 100 253 051 Pre-fail Offline - 0
  75.  
  76. SMART Error Log Version: 1
  77. ATA Error Count: 2378 (device log contains only the most recent five errors)
  78. CR = Command Register [HEX]
  79. FR = Features Register [HEX]
  80. SC = Sector Count Register [HEX]
  81. SN = Sector Number Register [HEX]
  82. CL = Cylinder Low Register [HEX]
  83. CH = Cylinder High Register [HEX]
  84. DH = Device/Head Register [HEX]
  85. DC = Device Command Register [HEX]
  86. ER = Error register [HEX]
  87. ST = Status register [HEX]
  88. Powered_Up_Time is measured from power on, and printed as
  89. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  90. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  91.  
  92. Error 2378 occurred at disk power-on lifetime: 6562 hours (273 days + 10 hours)
  93. When the command that caused the error occurred, the device was active or idle.
  94.  
  95. After command completion occurred, registers were:
  96. ER ST SC SN CL CH DH
  97. -- -- -- -- -- -- --
  98. 40 51 00 00 60 60 e0 Error: UNC at LBA = 0x00606000 = 6316032
  99.  
  100. Commands leading to the command that caused the error were:
  101. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  102. -- -- -- -- -- -- -- -- ---------------- --------------------
  103. 25 00 00 00 60 60 1c 00 02:07:42.427 READ DMA EXT
  104. 25 00 00 00 60 60 1c 00 02:07:38.211 READ DMA EXT
  105. 25 00 00 00 60 60 1c 00 02:07:34.261 READ DMA EXT
  106. 25 00 00 00 60 60 1c 00 02:07:30.311 READ DMA EXT
  107. 25 00 00 00 60 60 1c 00 02:07:26.094 READ DMA EXT
  108.  
  109. Error 2377 occurred at disk power-on lifetime: 6562 hours (273 days + 10 hours)
  110. When the command that caused the error occurred, the device was active or idle.
  111.  
  112. After command completion occurred, registers were:
  113. ER ST SC SN CL CH DH
  114. -- -- -- -- -- -- --
  115. 40 51 00 00 60 60 e0 Error: UNC at LBA = 0x00606000 = 6316032
  116.  
  117. Commands leading to the command that caused the error were:
  118. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  119. -- -- -- -- -- -- -- -- ---------------- --------------------
  120. 25 00 00 00 60 60 1c 00 02:07:38.211 READ DMA EXT
  121. 25 00 00 00 60 60 1c 00 02:07:34.261 READ DMA EXT
  122. 25 00 00 00 60 60 1c 00 02:07:30.311 READ DMA EXT
  123. 25 00 00 00 60 60 1c 00 02:07:26.094 READ DMA EXT
  124. 25 00 00 00 60 60 1c 00 02:07:22.011 READ DMA EXT
  125.  
  126. Error 2376 occurred at disk power-on lifetime: 6562 hours (273 days + 10 hours)
  127. When the command that caused the error occurred, the device was active or idle.
  128.  
  129. After command completion occurred, registers were:
  130. ER ST SC SN CL CH DH
  131. -- -- -- -- -- -- --
  132. 40 51 00 00 60 60 e0 Error: UNC at LBA = 0x00606000 = 6316032
  133.  
  134. Commands leading to the command that caused the error were:
  135. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  136. -- -- -- -- -- -- -- -- ---------------- --------------------
  137. 25 00 00 00 60 60 1c 00 02:07:34.261 READ DMA EXT
  138. 25 00 00 00 60 60 1c 00 02:07:30.311 READ DMA EXT
  139. 25 00 00 00 60 60 1c 00 02:07:26.094 READ DMA EXT
  140. 25 00 00 00 60 60 1c 00 02:07:22.011 READ DMA EXT
  141. 25 00 00 00 60 60 1c 00 02:07:17.928 READ DMA EXT
  142.  
  143. Error 2375 occurred at disk power-on lifetime: 6562 hours (273 days + 10 hours)
  144. When the command that caused the error occurred, the device was active or idle.
  145.  
  146. After command completion occurred, registers were:
  147. ER ST SC SN CL CH DH
  148. -- -- -- -- -- -- --
  149. 40 51 00 00 60 60 e0 Error: UNC at LBA = 0x00606000 = 6316032
  150.  
  151. Commands leading to the command that caused the error were:
  152. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  153. -- -- -- -- -- -- -- -- ---------------- --------------------
  154. 25 00 00 00 60 60 1c 00 02:07:30.311 READ DMA EXT
  155. 25 00 00 00 60 60 1c 00 02:07:26.094 READ DMA EXT
  156. 25 00 00 00 60 60 1c 00 02:07:22.011 READ DMA EXT
  157. 25 00 00 00 60 60 1c 00 02:07:17.928 READ DMA EXT
  158. 25 00 00 00 60 60 1c 00 02:07:13.978 READ DMA EXT
  159.  
  160. Error 2374 occurred at disk power-on lifetime: 6562 hours (273 days + 10 hours)
  161. When the command that caused the error occurred, the device was active or idle.
  162.  
  163. After command completion occurred, registers were:
  164. ER ST SC SN CL CH DH
  165. -- -- -- -- -- -- --
  166. 40 51 00 00 60 60 e0 Error: UNC at LBA = 0x00606000 = 6316032
  167.  
  168. Commands leading to the command that caused the error were:
  169. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  170. -- -- -- -- -- -- -- -- ---------------- --------------------
  171. 25 00 00 00 60 60 1c 00 02:07:26.094 READ DMA EXT
  172. 25 00 00 00 60 60 1c 00 02:07:22.011 READ DMA EXT
  173. 25 00 00 00 60 60 1c 00 02:07:17.928 READ DMA EXT
  174. 25 00 00 00 60 60 1c 00 02:07:13.978 READ DMA EXT
  175. 25 00 00 00 60 60 1c 00 02:07:09.895 READ DMA EXT
  176.  
  177. SMART Self-test log structure revision number 1
  178. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  179.  
  180. SMART Selective self-test log data structure revision number 1
  181. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  182. 1 0 0 Not_testing
  183. 2 0 0 Not_testing
  184. 3 0 0 Not_testing
  185. 4 0 0 Not_testing
  186. 5 0 0 Not_testing
  187. Selective self-test flags (0x0):
  188. After scanning selected spans, do NOT read-scan remainder of disk.
  189. If Selective self-test is pending on power-up, resume after 0 minute delay.