- 2018 Nov 11 06:14:38 Cisco %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN: System shutdown in
- 115 seconds due to major temperature alarm
- 2018 Nov 11 06:14:43 Cisco %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN: System shutdown in
- 110 seconds due to major temperature alarm
- 2018 Nov 11 06:14:48 Cisco %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN: System shutdown in
- 105 seconds due to major temperature alarm
- 2018 Nov 11 06:14:53 Cisco %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN: System shutdown in
- 100 seconds due to major temperature alarm
- 2018 Nov 11 06:14:58 Cisco %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN: System shutdown in
- 95 seconds due to major temperature alarm
- 2018 Nov 11 06:15:03 Cisco %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN: System shutdown in
- 90 seconds due to major temperature alarm
- Show system reset-reason
- At 365419 usecs after Sun Nov 11 06:16:33 2018
- Reason: Power down due to temperature sensor policy trigger
- Service:
- Version: 6.0(2)U3(8)
- 2) At 464846 usecs after Sat Nov 10 05:38:59 2018
- Reason: Power down due to temperature sensor policy trigger
- Service:
- Version: 6.0(2)U3(8)
- 3) No time
- Reason: Unknown
- Service:
- Version: 6.0(2)U3(8)
- 4) No time
- Reason: Unknown
- Service:
- Version: 6.0(2)U3(8)
- Cisco# show environment
- Fan:
- ------------------------------------------------------
- Fan Model Hw Status
- ------------------------------------------------------
- Fan-1 N3K-C3048-FAN -- ok
- PS-1 N2200-PAC-400W -- ok
- PS-2 -- -- absent
- Temperature
- -------------------------------------------------------------------------
- Module Sensor MajorThresh MinorThres CurTemp Status
- (Celsius) (Celsius) (Celsius)
- -------------------------------------------------------------------------
- 1 Back (D0) 55 45 47 minor alarm
- 1 Front Middle(D1) 65 57 64 minor alarm
- 1 Front Right (D2) 60 52 50 ok
- 1 Front Left (D3) 60 51 53 minor alarm
- Power Supply:
- ...skipping one line
- -----------------------------------------------------------
- PS Model Input Power Current Status
- Type (Watts) (Amps)
- -----------------------------------------------------------
- 1 N2200-PAC-400W AC 396.00 33.00 ok
- 2 -- -- -- -- absent
- Mod Model Power Current Power Current Status
- Requested Requested Allocated Allocated
- (Watts) (Amps) (Watts) (Amps)
- --- ---------------------- ------- ---------- --------- ---------- --------
- --
- 1 N3K-C3048TP-1GE-SUP 349.20 29.10 349.20 29.10 powered-
- up
- Power Usage Summary:
- --------------------
- Power Supply redundancy mode: Redundant
- Power Supply redundancy operational mode: Non-redundant
- Total Power Capacity 396.00 W
- Power reserved for Supervisor(s) 349.20 W
- Power currently used by Modules 0.00 W
- -------------
- Total Power Available 46.80 W
- -------------
- Cisco# show environment temperature
- Temperature
- -------------------------------------------------------------------------
- Module Sensor MajorThresh MinorThres CurTemp Status
- (Celsius) (Celsius) (Celsius)
- -------------------------------------------------------------------------
- 1 Back (D0) 55 45 47 minor alarm
- 1 Front Middle(D1) 65 57 64 minor alarm
- 1 Front Right (D2) 60 52 50 ok
- 1 Front Left (D3) 60 51 52 minor alarm
- Cisco# show module
- Mod Ports Module-Type Model Status
- --- ----- ----------------------------------- ---------------------- -----------
- -
- 1 52 48x1GE + 4x10G Supervisor N3K-C3048TP-1GE-SUP active *
- Mod Sw Hw World-Wide-Name(s) (WWN)
- --- -------------- ------ ---------------------------------------------------
- -
- 1 6.0(2)U3(8) 1.6 --
- Mod MAC-Address(es) Serial-Num