- DRAM diagnostic process has begun...
- -----------------------------------------------------------
- 14:54:57 STEP #0
- Setting timings, termination settings and voltages...
- Saving intermediate values...
- ***HYDRA 2.2A PRO (2201) by 1usmus***
- Super Admin mode: Off
- W10 Pro (22H2) 4/2/2026 14:57:15
- AMD Ryzen 9 9950X Stepping 0 SVM: On Unknown CMK64GX5M2B6000C40 62GB
- MSI MPG X870E CARBON WIFI (MS-7E49) BIOS 1.A95 ComboAm5PI 1.3.0.0 (98.83.00) TABLE 6423045
- 0 - NVIDIA GeForce RTX 3060 (Active) GeForce 595.97
- Restoring the diagnostic process. Please do not take any actions.
- ExecutePowercfgCommand failed (ExitCode=1): The power scheme, subgroup or setting specified does not exist.
- Attempting to recover DRAM diagnostic data...
- Phoenix enabled...
- DRAM diagnostic process has begun...
- -----------------------------------------------------------
- 14:57:22 STEP #1
- 14:57:24 DRAM unstable!
- Selecting the next group of ODT values...
- Saving intermediate values...
- ***HYDRA 2.2A PRO (2201) by 1usmus***
- Super Admin mode: Off
- W10 Pro (22H2) 4/2/2026 15:54:00
- AMD Ryzen 9 9950X Stepping 0 SVM: On Unknown CMK64GX5M2B6000C40 64GB
- MSI MPG X870E CARBON WIFI (MS-7E49) BIOS 1.A95 ComboAm5PI 1.3.0.0 (98.83.00) TABLE 6423045
- 0 - NVIDIA GeForce RTX 3060 (Active) GeForce 595.97
- Restoring the diagnostic process. Please do not take any actions.
- ExecutePowercfgCommand failed (ExitCode=1): The power scheme, subgroup or setting specified does not exist.
- Attempting to recover DRAM diagnostic data...
- Phoenix enabled...
- DRAM diagnostic process has begun...
- -----------------------------------------------------------
- 15:54:07 STEP #2
- 15:54:09 DRAM unstable!
- Selecting the next group of ODT values...
- Saving intermediate values...
- ***HYDRA 2.2A PRO (2201) by 1usmus***
- Super Admin mode: Off
- W10 Pro (22H2) 4/2/2026 15:56:39
- AMD Ryzen 9 9950X Stepping 0 SVM: On Unknown CMK64GX5M2B6000C40 64GB
- MSI MPG X870E CARBON WIFI (MS-7E49) BIOS 1.A95 ComboAm5PI 1.3.0.0 (98.83.00) TABLE 6423045
- 0 - NVIDIA GeForce RTX 3060 (Active) GeForce 595.97
- Restoring the diagnostic process. Please do not take any actions.
- ExecutePowercfgCommand failed (ExitCode=1): The power scheme, subgroup or setting specified does not exist.
- Attempting to recover DRAM diagnostic data...
- Phoenix enabled...
- DRAM diagnostic process has begun...
- -----------------------------------------------------------
- 15:56:45 STEP #3
- 15:56:47 DRAM unstable!
- Selecting the next group of ODT values...
- Saving intermediate values...
- ***HYDRA 2.2A PRO (2201) by 1usmus***
- Super Admin mode: Off
- W10 Pro (22H2) 4/2/2026 16:03:00
- AMD Ryzen 9 9950X Stepping 0 SVM: On Unknown CMK64GX5M2B6000C40 62GB
- MSI MPG X870E CARBON WIFI (MS-7E49) BIOS 1.A95 ComboAm5PI 1.3.0.0 (98.83.00) TABLE 6423045
- 0 - NVIDIA GeForce RTX 3060 (Active) GeForce 595.97
- Restoring the diagnostic process. Please do not take any actions.
- ExecutePowercfgCommand failed (ExitCode=1): The power scheme, subgroup or setting specified does not exist.
- Attempting to recover DRAM diagnostic data...
- Phoenix enabled...
- DRAM diagnostic process has begun...
- -----------------------------------------------------------
- 16:03:07 STEP #4
- 16:03:09 DRAM unstable!
- Selecting the next group of ODT values...
- Saving intermediate values...
- ***HYDRA 2.2A PRO (2201) by 1usmus***
- Super Admin mode: Off
- W10 Pro (22H2) 4/2/2026 16:05:20
- AMD Ryzen 9 9950X Stepping 0 SVM: On Unknown CMK64GX5M2B6000C40 62GB
- MSI MPG X870E CARBON WIFI (MS-7E49) BIOS 1.A95 ComboAm5PI 1.3.0.0 (98.83.00) TABLE 6423045
- 0 - NVIDIA GeForce RTX 3060 (Active) GeForce 595.97
- Restoring the diagnostic process. Please do not take any actions.
- ExecutePowercfgCommand failed (ExitCode=1): The power scheme, subgroup or setting specified does not exist.
- Attempting to recover DRAM diagnostic data...
- Phoenix enabled...
- DRAM diagnostic process has begun...
- -----------------------------------------------------------
- 16:05:27 STEP #5
- 16:05:29 DRAM unstable!
- HYDRA has no idea which setting is causing the instability...
- You might want to reconsider all of your diagnostics settings!
- Phoenix disabled...
- ExecutePowercfgCommand failed (ExitCode=1): The power scheme, subgroup or setting specified does not exist.