  1. smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.14.49-unRAID] (local build)
  2. Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Red
  6. Device Model: WDC WD30EFRX-68EUZN0
  7. Serial Number: WD-WMC4N1883501
  8. LU WWN Device Id: 5 0014ee 6aedd1253
  9. Firmware Version: 80.00A80
  10. User Capacity: 3,000,592,982,016 bytes [3.00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Rotation Rate: 5400 rpm
  13. Device is: In smartctl database [for details use: -P show]
  14. ATA Version is: ACS-2 (minor revision not indicated)
  15. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  16. Local Time is: Sat Aug 4 21:19:03 2018 CST
  17. SMART support is: Available - device has SMART capability.
  18. SMART support is: Enabled
  19. AAM feature is: Unavailable
  20. APM feature is: Unavailable
  21. Rd look-ahead is: Enabled
  22. Write cache is: Enabled
  23. DSN feature is: Unavailable
  24. ATA Security is: Disabled, frozen [SEC2]
  25. Wt Cache Reorder: Enabled
  26.  
  27. === START OF READ SMART DATA SECTION ===
  28. SMART overall-health self-assessment test result: PASSED
  29.  
  30. General SMART Values:
  31. Offline data collection status: (0x00) Offline data collection activity
  32. was never started.
  33. Auto Offline Data Collection: Disabled.
  34. Self-test execution status: ( 0) The previous self-test routine completed
  35. without error or no self-test has ever
  36. been run.
  37. Total time to complete Offline
  38. data collection: (39900) seconds.
  39. Offline data collection
  40. capabilities: (0x7b) SMART execute Offline immediate.
  41. Auto Offline data collection on/off support.
  42. Suspend Offline collection upon new
  43. command.
  44. Offline surface scan supported.
  45. Self-test supported.
  46. Conveyance Self-test supported.
  47. Selective Self-test supported.
  48. SMART capabilities: (0x0003) Saves SMART data before entering
  49. power-saving mode.
  50. Supports SMART auto save timer.
  51. Error logging capability: (0x01) Error logging supported.
  52. General Purpose Logging supported.
  53. Short self-test routine
  54. recommended polling time: ( 2) minutes.
  55. Extended self-test routine
  56. recommended polling time: ( 400) minutes.
  57. Conveyance self-test routine
  58. recommended polling time: ( 5) minutes.
  59. SCT capabilities: (0x703d) SCT Status supported.
  60. SCT Error Recovery Control supported.
  61. SCT Feature Control supported.
  62. SCT Data Table supported.
  63.  
  64. SMART Attributes Data Structure revision number: 16
  65. Vendor Specific SMART Attributes with Thresholds:
  66. ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
  67. 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 3
  68. 3 Spin_Up_Time POS--K 178 177 021 - 6058
  69. 4 Start_Stop_Count -O--CK 100 100 000 - 96
  70. 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
  71. 7 Seek_Error_Rate -OSR-K 200 200 000 - 0
  72. 9 Power_On_Hours -O--CK 058 058 000 - 31074
  73. 10 Spin_Retry_Count -O--CK 100 253 000 - 0
  74. 11 Calibration_Retry_Count -O--CK 100 253 000 - 0
  75. 12 Power_Cycle_Count -O--CK 100 100 000 - 96
  76. 192 Power-Off_Retract_Count -O--CK 200 200 000 - 44
  77. 193 Load_Cycle_Count -O--CK 184 184 000 - 48728
  78. 194 Temperature_Celsius -O---K 114 110 000 - 36
  79. 196 Reallocated_Event_Count -O--CK 200 200 000 - 0
  80. 197 Current_Pending_Sector -O--CK 200 200 000 - 0
  81. 198 Offline_Uncorrectable ----CK 100 253 000 - 0
  82. 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
  83. 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
  84. ||||||_ K auto-keep
  85. |||||__ C event count
  86. ||||___ R error rate
  87. |||____ S speed/performance
  88. ||_____ O updated online
  89. |______ P prefailure warning
  90.  
  91. General Purpose Log Directory Version 1
  92. SMART Log Directory Version 1 [multi-sector log support]
  93. Address Access R/W Size Description
  94. 0x00 GPL,SL R/O 1 Log Directory
  95. 0x01 SL R/O 1 Summary SMART error log
  96. 0x02 SL R/O 5 Comprehensive SMART error log
  97. 0x03 GPL R/O 6 Ext. Comprehensive SMART error log
  98. 0x06 SL R/O 1 SMART self-test log
  99. 0x07 GPL R/O 1 Extended self-test log
  100. 0x09 SL R/W 1 Selective self-test log
  101. 0x10 GPL R/O 1 NCQ Command Error log
  102. 0x11 GPL R/O 1 SATA Phy Event Counters log
  103. 0x21 GPL R/O 1 Write stream error log
  104. 0x22 GPL R/O 1 Read stream error log
  105. 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
  106. 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
  107. 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
  108. 0xbd GPL,SL VS 1 Device vendor specific log
  109. 0xc0 GPL,SL VS 1 Device vendor specific log
  110. 0xc1 GPL VS 93 Device vendor specific log
  111. 0xe0 GPL,SL R/W 1 SCT Command/Status
  112. 0xe1 GPL,SL R/W 1 SCT Data Transfer
  113.  
  114. SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
  115. Device Error Count: 3
  116. CR = Command Register
  117. FEATR = Features Register
  118. COUNT = Count (was: Sector Count) Register
  119. LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
  120. LH = LBA High (was: Cylinder High) Register ] LBA
  121. LM = LBA Mid (was: Cylinder Low) Register ] Register
  122. LL = LBA Low (was: Sector Number) Register ]
  123. DV = Device (was: Device/Head) Register
  124. DC = Device Control Register
  125. ER = Error register
  126. ST = Status register
  127. Powered_Up_Time is measured from power on, and printed as
  128. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  129. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  130.  
  131. Error 3 [2] occurred at disk power-on lifetime: 31049 hours (1293 days + 17 hours)
  132. When the command that caused the error occurred, the device was active or idle.
  133.  
  134. After command completion occurred, registers were:
  135. ER -- ST COUNT LBA_48 LH LM LL DV DC
  136. -- -- -- == -- == == == -- -- -- -- --
  137. 40 -- 51 05 40 00 01 44 19 e6 d8 e0 00 Error: UNC 1344 sectors at LBA = 0x14419e6d8 = 5437515480
  138.  
  139. Commands leading to the command that caused the error were:
  140. CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
  141. -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
  142. 25 00 00 05 40 00 01 44 19 e3 28 e0 08 1d+20:57:47.432 READ DMA EXT
  143. 25 00 00 01 80 00 01 44 19 e1 a8 e0 08 1d+20:57:47.417 READ DMA EXT
  144. 25 00 00 05 40 00 01 44 19 dc 68 e0 08 1d+20:57:47.416 READ DMA EXT
  145. 25 00 00 05 40 00 01 44 19 d7 28 e0 08 1d+20:57:47.405 READ DMA EXT
  146. 25 00 00 05 40 00 01 44 19 d1 e8 e0 08 1d+20:57:47.404 READ DMA EXT
  147.  
  148. Error 2 [1] occurred at disk power-on lifetime: 31003 hours (1291 days + 19 hours)
  149. When the command that caused the error occurred, the device was active or idle.
  150.  
  151. After command completion occurred, registers were:
  152. ER -- ST COUNT LBA_48 LH LM LL DV DC
  153. -- -- -- == -- == == == -- -- -- -- --
  154. 40 -- 51 05 40 00 01 44 19 e6 d8 e0 00 Error: UNC 1344 sectors at LBA = 0x14419e6d8 = 5437515480
  155.  
  156. Commands leading to the command that caused the error were:
  157. CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
  158. -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
  159. 25 00 00 05 40 00 01 44 19 e4 48 e0 08 3d+17:58:45.594 READ DMA EXT
  160. 25 00 00 05 40 00 01 44 19 df 08 e0 08 3d+17:58:45.593 READ DMA EXT
  161. 25 00 00 01 80 00 01 44 19 dd 88 e0 08 3d+17:58:45.576 READ DMA EXT
  162. 25 00 00 05 40 00 01 44 19 d8 48 e0 08 3d+17:58:45.575 READ DMA EXT
  163. 25 00 00 05 40 00 01 44 19 d3 08 e0 08 3d+17:58:45.564 READ DMA EXT
  164.  
  165. Error 1 [0] occurred at disk power-on lifetime: 30967 hours (1290 days + 7 hours)
  166. When the command that caused the error occurred, the device was active or idle.
  167.  
  168. After command completion occurred, registers were:
  169. ER -- ST COUNT LBA_48 LH LM LL DV DC
  170. -- -- -- == -- == == == -- -- -- -- --
  171. 40 -- 51 02 40 00 01 44 19 e6 d8 e0 00 Error: UNC 576 sectors at LBA = 0x14419e6d8 = 5437515480
  172.  
  173. Commands leading to the command that caused the error were:
  174. CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
  175. -- == -- == -- == == == -- -- -- -- -- --------------- --------------------
  176. 25 00 00 02 40 00 01 44 19 e5 f8 e0 08 2d+05:55:47.617 READ DMA EXT
  177. 25 00 00 03 d0 00 00 d4 a9 d1 98 e0 08 2d+05:55:47.599 READ DMA EXT
  178. 25 00 00 05 40 00 00 d4 a9 cc 58 e0 08 2d+05:55:47.594 READ DMA EXT
  179. 25 00 00 04 d0 00 01 44 19 e1 28 e0 08 2d+05:55:47.593 READ DMA EXT
  180. 25 00 00 02 08 00 01 44 19 df 20 e0 08 2d+05:55:47.592 READ DMA EXT
  181.  
  182. SMART Extended Self-test Log Version: 1 (1 sectors)
  183. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  184. # 1 Extended offline Completed without error 00% 31066 -
  185. # 2 Short offline Completed without error 00% 1365 -
  186. # 3 Short offline Completed without error 00% 1364 -
  187. # 4 Short offline Completed without error 00% 1364 -
  188.  
  189. SMART Selective self-test log data structure revision number 1
  190. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  191. 1 0 0 Not_testing
  192. 2 0 0 Not_testing
  193. 3 0 0 Not_testing
  194. 4 0 0 Not_testing
  195. 5 0 0 Not_testing
  196. Selective self-test flags (0x0):
  197. After scanning selected spans, do NOT read-scan remainder of disk.
  198. If Selective self-test is pending on power-up, resume after 0 minute delay.
  199.  
  200. SCT Status Version: 3
  201. SCT Version (vendor specific): 258 (0x0102)
  202. SCT Support Level: 1
  203. Device State: Active (0)
  204. Current Temperature: 36 Celsius
  205. Power Cycle Min/Max Temperature: 32/40 Celsius
  206. Lifetime Min/Max Temperature: 16/40 Celsius
  207. Under/Over Temperature Limit Count: 0/0
  208. Vendor specific:
  209. 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
  210. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
  211.  
  212. SCT Temperature History Version: 2
  213. Temperature Sampling Period: 1 minute
  214. Temperature Logging Interval: 1 minute
  215. Min/Max recommended Temperature: 0/60 Celsius
  216. Min/Max Temperature Limit: -41/85 Celsius
  217. Temperature History Size (Index): 478 (370)
  218.  
  219. Index Estimated Time Temperature Celsius
  220. 371 2018-08-04 13:22 35 ****************
  221. ... ..( 22 skipped). .. ****************
  222. 394 2018-08-04 13:45 35 ****************
  223. 395 2018-08-04 13:46 36 *****************
  224. ... ..( 17 skipped). .. *****************
  225. 413 2018-08-04 14:04 36 *****************
  226. 414 2018-08-04 14:05 37 ******************
  227. ... ..( 12 skipped). .. ******************
  228. 427 2018-08-04 14:18 37 ******************
  229. 428 2018-08-04 14:19 36 *****************
  230. ... ..( 22 skipped). .. *****************
  231. 451 2018-08-04 14:42 36 *****************
  232. 452 2018-08-04 14:43 37 ******************
  233. ... ..( 10 skipped). .. ******************
  234. 463 2018-08-04 14:54 37 ******************
  235. 464 2018-08-04 14:55 36 *****************
  236. ... ..( 9 skipped). .. *****************
  237. 474 2018-08-04 15:05 36 *****************
  238. 475 2018-08-04 15:06 35 ****************
  239. ... ..(232 skipped). .. ****************
  240. 230 2018-08-04 18:59 35 ****************
  241. 231 2018-08-04 19:00 36 *****************
  242. ... ..( 25 skipped). .. *****************
  243. 257 2018-08-04 19:26 36 *****************
  244. 258 2018-08-04 19:27 35 ****************
  245. ... ..( 63 skipped). .. ****************
  246. 322 2018-08-04 20:31 35 ****************
  247. 323 2018-08-04 20:32 36 *****************
  248. ... ..( 16 skipped). .. *****************
  249. 340 2018-08-04 20:49 36 *****************
  250. 341 2018-08-04 20:50 35 ****************
  251. ... ..( 28 skipped). .. ****************
  252. 370 2018-08-04 21:19 35 ****************
  253.  
  254. SCT Error Recovery Control:
  255. Read: 70 (7.0 seconds)
  256. Write: 70 (7.0 seconds)
  257.  
  258. Device Statistics (GP/SMART Log 0x04) not supported
  259.  
  260. Pending Defects log (GP Log 0x0c) not supported
  261.  
  262. SATA Phy Event Counters (GP Log 0x11)
  263. ID Size Value Description
  264. 0x0001 2 0 Command failed due to ICRC error
  265. 0x0002 2 0 R_ERR response for data FIS
  266. 0x0003 2 0 R_ERR response for device-to-host data FIS
  267. 0x0004 2 0 R_ERR response for host-to-device data FIS
  268. 0x0005 2 0 R_ERR response for non-data FIS
  269. 0x0006 2 0 R_ERR response for device-to-host non-data FIS
  270. 0x0007 2 0 R_ERR response for host-to-device non-data FIS
  271. 0x0008 2 0 Device-to-host non-data FIS retries
  272. 0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
  273. 0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
  274. 0x000b 2 0 CRC errors within host-to-device FIS
  275. 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
  276. 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
  277. 0x8000 4 250750 Vendor specific