  1. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Seagate NAS HDD
  6. Device Model: ST3000VN000-1H4167
  7. Serial Number: S300AXKM
  8. LU WWN Device Id: 5 000c50 06d630238
  9. Firmware Version: SC43
  10. User Capacity: 3,000,592,982,016 bytes [3.00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: 9
  14. ATA Standard is: Not recognized. Minor revision code: 0x001f
  15. Local Time is: Fri May 8 12:05:25 2015 EDT
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART STATUS RETURN: incomplete response, ATA output registers missing
  21. SMART overall-health self-assessment test result: PASSED
  22. Warning: This result is based on an Attribute check.
  23.  
  24. General SMART Values:
  25. Offline data collection status: (0x00) Offline data collection activity
  26. was never started.
  27. Auto Offline Data Collection: Disabled.
  28. Self-test execution status: ( 0) The previous self-test routine completed
  29. without error or no self-test has ever
  30. been run.
  31. Total time to complete Offline
  32. data collection: ( 148) seconds.
  33. Offline data collection
  34. capabilities: (0x73) SMART execute Offline immediate.
  35. Auto Offline data collection on/off support.
  36. Suspend Offline collection upon new
  37. command.
  38. No Offline surface scan supported.
  39. Self-test supported.
  40. Conveyance Self-test supported.
  41. Selective Self-test supported.
  42. SMART capabilities: (0x0003) Saves SMART data before entering
  43. power-saving mode.
  44. Supports SMART auto save timer.
  45. Error logging capability: (0x01) Error logging supported.
  46. General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time: ( 1) minutes.
  49. Extended self-test routine
  50. recommended polling time: ( 255) minutes.
  51. Conveyance self-test routine
  52. recommended polling time: ( 2) minutes.
  53. SCT capabilities: (0x10bd) SCT Status supported.
  54. SCT Error Recovery Control supported.
  55. SCT Feature Control supported.
  56. SCT Data Table supported.
  57.  
  58. SMART Attributes Data Structure revision number: 10
  59. Vendor Specific SMART Attributes with Thresholds:
  60. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  61. 1 Raw_Read_Error_Rate 0x000f 119 099 006 Pre-fail Always - 213802064
  62. 3 Spin_Up_Time 0x0003 092 091 000 Pre-fail Always - 0
  63. 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 50
  64. 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
  65. 7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 17922327
  66. 9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 3043
  67. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  68. 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 50
  69. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  70. 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
  71. 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
  72. 189 High_Fly_Writes 0x003a 031 031 000 Old_age Always - 69
  73. 190 Airflow_Temperature_Cel 0x0022 068 065 045 Old_age Always - 32 (Min/Max 23/35)
  74. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
  75. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 49
  76. 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 50
  77. 194 Temperature_Celsius 0x0022 032 040 000 Old_age Always - 32 (0 19 0 0)
  78. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
  79. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
  80. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  81.  
  82. SMART Error Log Version: 1
  83. No Errors Logged
  84.  
  85. SMART Self-test log structure revision number 1
  86. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  87. # 1 Extended offline Completed without error 00% 2875 -
  88. # 2 Extended offline Completed without error 00% 2861 -
  89. # 3 Short offline Completed without error 00% 2849 -
  90.  
  91. SMART Selective self-test log data structure revision number 1
  92. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  93. 1 0 0 Not_testing
  94. 2 0 0 Not_testing
  95. 3 0 0 Not_testing
  96. 4 0 0 Not_testing
  97. 5 0 0 Not_testing
  98. Selective self-test flags (0x0):
  99. After scanning selected spans, do NOT read-scan remainder of disk.
  100. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment