- smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.8.0-54-generic] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Device Model: SanDisk SDSSDA120G
- Serial Number: 151437401769
- LU WWN Device Id: 5 001b44 e4df45aa9
- Firmware Version: Z22000RL
- User Capacity: 120,034,123,776 bytes [120 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: Solid State Device
- Form Factor: 1.8 inches
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: ACS-2 T13/2015-D revision 3
- SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Fri Jun 9 02:41:25 2017 BST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x02) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 0) seconds.
- Offline data collection
- capabilities: (0x71) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0002) Does not save SMART data before
- entering power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 10) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SMART Attributes Data Structure revision number: 1
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 053 100 000 Old_age Always - 821
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 2288
- 166 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 2681
- 167 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 168 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 2732
- 169 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 32
- 170 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
- 173 Unknown_Attribute 0x0032 100 100 --- Old_age Always - 2704
- 174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 116
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 194 Temperature_Celsius 0x0022 067 100 000 Old_age Always - 33 (Min/Max 0/52)
- 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 4168
- 230 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 90
- 232 Available_Reservd_Space 0x0033 100 100 004 Pre-fail Always - 100
- 233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 239691
- 241 Total_LBAs_Written 0x0030 253 253 000 Old_age Offline - 8587
- 242 Total_LBAs_Read 0x0030 253 253 000 Old_age Offline - 8974
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Offline Completed without error 00% 23 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.