- > zigbee2mqtt@1.7.1 start /opt/zigbee2mqtt
- > node index.js
- winston:create-logger Define prototype method for "error"
- winston:create-logger Define prototype method for "warn"
- winston:create-logger Define prototype method for "info"
- winston:create-logger Define prototype method for "http"
- winston:create-logger Define prototype method for "verbose"
- winston:create-logger Define prototype method for "debug"
- winston:create-logger Define prototype method for "silly"
- winston:create-logger Define prototype method for "error"
- winston:create-logger Define prototype method for "warn"
- winston:create-logger Define prototype method for "info"
- winston:create-logger Define prototype method for "http"
- winston:create-logger Define prototype method for "verbose"
- winston:create-logger Define prototype method for "debug"
- winston:create-logger Define prototype method for "silly"
- zigbee2mqtt:info 2019-12-08T15:38:26: Logging to directory: '/opt/zigbee2mqtt/data/log/2019-12-08.15-38-26'
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-32-04'
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-32-00'
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-28-24'
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-28-01'
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-27-46'
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.14-50-56'
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Loaded state from file /opt/zigbee2mqtt/data/state.json
- winston:file written true false
- winston:file logged 97 info 2019-12-08T15:38:26: Logging to directory: '/opt/zigbee2mqtt/data/log/2019-12-08.15-38-26'
- winston:file logged 199 debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-32-04'
- winston:file logged 301 debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-32-00'
- winston:file logged 403 debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-28-24'
- winston:file logged 505 debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-28-01'
- winston:file logged 607 debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.15-27-46'
- winston:file logged 709 debug 2019-12-08T15:38:26: Removing old log directory '/opt/zigbee2mqtt/data/log/2019-12-08.14-50-56'
- winston:file logged 792 debug 2019-12-08T15:38:26: Loaded state from file /opt/zigbee2mqtt/data/state.json
- winston:file ENOENT ok /opt/zigbee2mqtt/data/log/2019-12-08.15-38-26/log.txt
- winston:file stat done: log.txt { size: 0 }
- winston:file create stream start /opt/zigbee2mqtt/data/log/2019-12-08.15-38-26/log.txt { flags: 'a' }
- winston:file create stream ok /opt/zigbee2mqtt/data/log/2019-12-08.15-38-26/log.txt
- winston:file file open ok /opt/zigbee2mqtt/data/log/2019-12-08.15-38-26/log.txt
- zigbee2mqtt:info 2019-12-08T15:38:26: Starting zigbee2mqtt version 1.7.1 (commit #b459c35)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:26: Starting zigbee-herdsman...
- winston:file written true false
- zigbee2mqtt:debug 2019-12-08T15:38:26: Using zigbee-herdsman with settings: '{"network":{"panID":6754,"extendedPanID":[221,221,221,221,221,221,221,221],"channelList":[11],"networkKey":"HIDDEN"},"databasePath":"/opt/zigbee2mqtt/data/database.db","databaseBackupPath":"/opt/zigbee2mqtt/data/database.db.backup","backupPath":"/opt/zigbee2mqtt/data/coordinator_backup.json","serialPort":{"baudRate":115200,"rtscts":true,"path":"/dev/serial/by-id/usb-Texas_Instruments_TI_CC2531_USB_CDC___0X00124B0018E1A764-if00"}}'
- winston:file written true false
- serialport/bindings loading LinuxBinding +0ms
- serialport/stream .list +0ms
- winston:file logged 80 info 2019-12-08T15:38:26: Starting zigbee2mqtt version 1.7.1 (commit #b459c35)
- winston:file logged 135 info 2019-12-08T15:38:26: Starting zigbee-herdsman...
- winston:file logged 635 debug 2019-12-08T15:38:26: Using zigbee-herdsman with settings: '{"network":{"panID":6754,"extendedPanID":[221,221,221,221,221,221,221,221],"channelList":[11],"networkKey":"HIDDEN"},"databasePath":"/opt/zigbee2mqtt/data/database.db","databaseBackupPath":"/opt/zigbee2mqtt/data/database.db.backup","backupPath":"/opt/zigbee2mqtt/data/coordinator_backup.json","serialPort":{"baudRate":115200,"rtscts":true,"path":"/dev/serial/by-id/usb-Texas_Instruments_TI_CC2531_USB_CDC___0X00124B0018E1A764-if00"}}'
- zigbee-herdsman:adapter Path '/dev/ttyACM0' is valid for 'ZStackAdapter' +0ms
- zigbee-herdsman:controller:log Starting with options '{"network":{"networkKeyDistribute":false,"networkKey":[1,3,5,7,9,11,13,15,0,2,4,6,8,10,12,13],"panID":6754,"extendedPanID":[221,221,221,221,221,221,221,221],"channelList":[11]},"serialPort":{"baudRate":115200,"rtscts":true,"path":"/dev/ttyACM0"},"databasePath":"/opt/zigbee2mqtt/data/database.db","databaseBackupPath":"/opt/zigbee2mqtt/data/database.db.backup","backupPath":"/opt/zigbee2mqtt/data/coordinator_backup.json"}' +0ms
- zigbee-herdsman:adapter:zStack:znp:log Opening with /dev/ttyACM0 and {"baudRate":115200,"rtscts":true,"autoOpen":false} +0ms
- serialport/stream opening path: /dev/ttyACM0 +218ms
- serialport/binding-abstract open +0ms
- serialport/stream _read queueing _read for after open +4ms
- serialport/bindings/poller Creating poller +0ms
- serialport/stream opened path: /dev/ttyACM0 +4ms
- serialport/stream _read reading { start: 0, toRead: 65536 } +0ms
- serialport/binding-abstract read +9ms
- zigbee-herdsman:adapter:zStack:znp:log Serialport opened +16ms
- zigbee-herdsman:adapter:zStack:znp:log Writing skip bootloader payload +1ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> buffer [239] +0ms
- serialport/stream _write 1 bytes of data +6ms
- serialport/binding-abstract write 1 bytes +5ms
- serialport/bindings/unixWrite Starting write 1 bytes offset 0 bytesToWrite 1 +0ms
- serialport/bindings/unixRead Starting read +0ms
- serialport/bindings/unixWrite write returned: wrote 1 bytes +2ms
- serialport/bindings/unixWrite Finished writing 1 bytes +1ms
- serialport/stream binding.write write finished +6ms
- serialport/bindings/unixRead Finished read { bytesRead: 58,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +3ms
- serialport/stream binding.read finished { bytesRead: 58 } +2ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,5,69,196,180,167,1,92,197,15,254,5,69,196,34,147,1,92,197,173,254,5,69,196,34,147,1,92,197,173,254,3,69,196,92,197,0,27,254,5,69,196,200,70,1,92,197,146,254,5,69,196,180,167,1,92,197,15] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,5,69,196,180,167,1,92,197,15,254,5,69,196,34,147,1,92,197,173,254,5,69,196,34,147,1,92,197,173,254,3,69,196,92,197,0,27,254,5,69,196,200,70,1,92,197,146,254,5,69,196,180,167,1,92,197,15] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 5 - 2 - 5 - 196 - [��\�] - 15 +2ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":42932,"relaycount":1,"relaylist":[50524]} +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,5,69,196,34,147,1,92,197,173,254,5,69,196,34,147,1,92,197,173,254,3,69,196,92,197,0,27,254,5,69,196,200,70,1,92,197,146,254,5,69,196,180,167,1,92,197,15] +6ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 5 - 2 - 5 - 196 - ["�\�] - 173 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":37666,"relaycount":1,"relaylist":[50524]} +3ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,5,69,196,34,147,1,92,197,173,254,3,69,196,92,197,0,27,254,5,69,196,200,70,1,92,197,146,254,5,69,196,180,167,1,92,197,15] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 5 - 2 - 5 - 196 - ["�\�] - 173 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":37666,"relaycount":1,"relaylist":[50524]} +2ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,69,196,92,197,0,27,254,5,69,196,200,70,1,92,197,146,254,5,69,196,180,167,1,92,197,15] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 5 - 196 - [\�] - 27 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":50524,"relaycount":0,"relaylist":[]} +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,5,69,196,200,70,1,92,197,146,254,5,69,196,180,167,1,92,197,15] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 5 - 2 - 5 - 196 - [�F\�] - 146 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":18120,"relaycount":1,"relaylist":[50524]} +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,5,69,196,180,167,1,92,197,15] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 5 - 2 - 5 - 196 - [��\�] - 15 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":42932,"relaycount":1,"relaylist":[50524]} +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- serialport/stream _read reading { start: 58, toRead: 65478 } +18ms
- serialport/binding-abstract read +26ms
- serialport/bindings/unixRead Starting read +20ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +0ms
- serialport/bindings/poller Polling for "readable" +35ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SYS - version - {} +0ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,0,33,2,35] +1s
- serialport/stream _write 5 bytes of data +993ms
- serialport/binding-abstract write 5 bytes +992ms
- serialport/bindings/unixWrite Starting write 5 bytes offset 0 bytesToWrite 5 +1s
- serialport/bindings/unixWrite write returned: wrote 5 bytes +1ms
- serialport/bindings/unixWrite Finished writing 5 bytes +1ms
- serialport/stream binding.write write finished +4ms
- serialport/bindings/poller received "readable" +998ms
- serialport/binding-abstract read +8ms
- serialport/bindings/unixRead Starting read +1s
- serialport/bindings/unixRead Finished read { bytesRead: 19,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 19 } +7ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,14,97,2,2,0,2,6,3,144,21,52,1,2,0,0,0,0,218] +1s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,14,97,2,2,0,2,6,3,144,21,52,1,2,0,0,0,0,218] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 14 - 3 - 1 - 2 - [�4] - 218 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SYS - version - {"transportrev":2,"product":0,"majorrel":2,"minorrel":6,"maintrel":3,"revision":20190608} +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +5ms
- zigbee-herdsman:adapter:zStack:adapter Detected znp version 'zStack12' ({"transportrev":2,"product":0,"majorrel":2,"minorrel":6,"maintrel":3,"revision":20190608}) +0ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SYS - osalNvRead - {"id":3840,"offset":0,"len":1,"value":{"type":"Buffer","data":[85]}} +31ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,3,33,8,0,15,0,37] +31ms
- serialport/stream _write 8 bytes of data +20ms
- serialport/binding-abstract write 8 bytes +23ms
- serialport/bindings/unixWrite Starting write 8 bytes offset 0 bytesToWrite 8 +29ms
- serialport/stream _read reading { start: 77, toRead: 65459 } +3ms
- serialport/binding-abstract read +3ms
- serialport/bindings/unixRead Starting read +25ms
- serialport/bindings/unixWrite write returned: wrote 8 bytes +3ms
- serialport/bindings/unixWrite Finished writing 8 bytes +0ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +31ms
- serialport/bindings/poller received "readable" +7ms
- serialport/binding-abstract read +12ms
- serialport/bindings/unixRead Starting read +9ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +11ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,97,8,0,1,85,62] +31ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,97,8,0,1,85,62] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 3 - 1 - 8 - [U] - 62 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SYS - osalNvRead - {"status":0,"len":1,"value":{"type":"Buffer","data":[85]}} +36ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- zigbee-herdsman:adapter:zStack:startZnp Item 'hasConfigured' is valid +0ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SYS - osalNvRead - {"id":3840,"offset":0,"len":1,"value":{"type":"Buffer","data":[85]}} +32ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,3,33,8,0,15,0,37] +28ms
- serialport/stream _write 8 bytes of data +11ms
- serialport/binding-abstract write 8 bytes +13ms
- serialport/bindings/unixWrite Starting write 8 bytes offset 0 bytesToWrite 8 +24ms
- serialport/stream _read reading { start: 85, toRead: 65451 } +2ms
- serialport/binding-abstract read +2ms
- serialport/bindings/unixRead Starting read +15ms
- serialport/bindings/unixWrite write returned: wrote 8 bytes +3ms
- serialport/bindings/unixWrite Finished writing 8 bytes +0ms
- serialport/stream binding.write write finished +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +19ms
- serialport/bindings/poller received "readable" +9ms
- serialport/binding-abstract read +12ms
- serialport/bindings/unixRead Starting read +9ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +11ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,97,8,0,1,85,62] +22ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,97,8,0,1,85,62] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 3 - 1 - 8 - [U] - 62 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SYS - osalNvRead - {"status":0,"len":1,"value":{"type":"Buffer","data":[85]}} +24ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Item 'hasConfigured' is valid +23ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SYS - osalNvRead - {"id":132,"len":4,"offset":0,"value":{"type":"Buffer","data":[0,8,0,0]}} +21ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,3,33,8,132,0,0,174] +21ms
- serialport/stream _write 8 bytes of data +5ms
- serialport/binding-abstract write 8 bytes +6ms
- serialport/bindings/unixWrite Starting write 8 bytes offset 0 bytesToWrite 8 +16ms
- serialport/stream _read reading { start: 93, toRead: 65443 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixWrite write returned: wrote 8 bytes +2ms
- serialport/bindings/unixWrite Finished writing 8 bytes +0ms
- serialport/stream binding.write write finished +1ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +8ms
- serialport/bindings/poller received "readable" +13ms
- serialport/binding-abstract read +15ms
- serialport/bindings/unixRead Starting read +17ms
- serialport/bindings/unixRead Finished read { bytesRead: 11,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 11 } +18ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,6,97,8,0,4,0,8,0,0,99] +24ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,6,97,8,0,4,0,8,0,0,99] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 6 - 3 - 1 - 8 - ] - 99 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SYS - osalNvRead - {"status":0,"len":4,"value":{"type":"Buffer","data":[0,8,0,0]}} +26ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Item 'channelList' is valid +26ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SYS - osalNvRead - {"id":99,"len":1,"offset":0,"value":{"type":"Buffer","data":[0]}} +25ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,3,33,8,99,0,0,73] +25ms
- serialport/stream _write 8 bytes of data +5ms
- serialport/binding-abstract write 8 bytes +9ms
- serialport/bindings/unixWrite Starting write 8 bytes offset 0 bytesToWrite 8 +23ms
- serialport/stream _read reading { start: 104, toRead: 65432 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +7ms
- serialport/bindings/unixWrite write returned: wrote 8 bytes +2ms
- serialport/bindings/unixWrite Finished writing 8 bytes +0ms
- serialport/stream binding.write write finished +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +13ms
- serialport/bindings/poller received "readable" +15ms
- serialport/binding-abstract read +18ms
- serialport/bindings/unixRead Starting read +16ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 8 } +16ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,97,8,0,1,0,107] +23ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,97,8,0,1,0,107] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 3 - 1 - 8 - [] - 107 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SYS - osalNvRead - {"status":0,"len":1,"value":{"type":"Buffer","data":[0]}} +23ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Item 'networkKeyDistribute' is valid +23ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SAPI - readConfiguration - {"id":98,"configid":98,"len":16,"offset":0,"value":{"type":"Buffer","data":[1,3,5,7,9,11,13,15,0,2,4,6,8,10,12,13]}} +23ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,1,38,4,98,65] +22ms
- serialport/stream _write 6 bytes of data +4ms
- serialport/binding-abstract write 6 bytes +4ms
- serialport/bindings/unixWrite Starting write 6 bytes offset 0 bytesToWrite 6 +21ms
- serialport/stream _read reading { start: 112, toRead: 65424 } +0ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixWrite write returned: wrote 6 bytes +1ms
- serialport/bindings/unixWrite Finished writing 6 bytes +0ms
- serialport/stream binding.write write finished +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +7ms
- serialport/bindings/poller received "readable" +28ms
- serialport/binding-abstract read +29ms
- serialport/bindings/unixRead Starting read +28ms
- serialport/bindings/unixRead Finished read { bytesRead: 24,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 24 } +29ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,19,102,4,0,98,16,1,3,5,7,9,11,13,15,0,2,4,6,8,10,12,13,0] +33ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,19,102,4,0,98,16,1,3,5,7,9,11,13,15,0,2,4,6,8,10,12,13,0] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 19 - 3 - 6 - 4 - [b
- zigbee-herdsman:adapter:zStack:unpi:parser
- ] - 0 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SAPI - readConfiguration - {"status":0,"configid":98,"len":16,"value":{"type":"Buffer","data":[1,3,5,7,9,11,13,15,0,2,4,6,8,10,12,13]}} +35ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- zigbee-herdsman:adapter:zStack:startZnp Item 'networkKey' is valid +35ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SYS - osalNvRead - {"id":131,"len":2,"offset":0,"value":{"type":"Buffer","data":[98,26]}} +35ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,3,33,8,131,0,0,169] +35ms
- serialport/stream _write 8 bytes of data +3ms
- serialport/binding-abstract write 8 bytes +4ms
- serialport/bindings/unixWrite Starting write 8 bytes offset 0 bytesToWrite 8 +34ms
- serialport/stream _read reading { start: 136, toRead: 65400 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixWrite write returned: wrote 8 bytes +1ms
- serialport/bindings/unixWrite Finished writing 8 bytes +0ms
- serialport/stream binding.write write finished +1ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +0ms
- serialport/bindings/poller Polling for "readable" +6ms
- serialport/bindings/poller received "readable" +12ms
- serialport/binding-abstract read +13ms
- serialport/bindings/unixRead Starting read +12ms
- serialport/bindings/unixRead Finished read { bytesRead: 9,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 9 } +13ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,4,97,8,0,2,98,26,23] +17ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,4,97,8,0,2,98,26,23] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 4 - 3 - 1 - 8 - [b] - 23 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SYS - osalNvRead - {"status":0,"len":2,"value":{"type":"Buffer","data":[98,26]}} +18ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Item 'panID' is valid +17ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> SYS - osalNvRead - {"id":45,"len":8,"offset":0,"value":{"type":"Buffer","data":[221,221,221,221,221,221,221,221]}} +17ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,3,33,8,45,0,0,7] +17ms
- serialport/stream _write 8 bytes of data +3ms
- serialport/binding-abstract write 8 bytes +4ms
- serialport/bindings/unixWrite Starting write 8 bytes offset 0 bytesToWrite 8 +16ms
- serialport/stream _read reading { start: 145, toRead: 65391 } +0ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixWrite write returned: wrote 8 bytes +1ms
- serialport/bindings/unixWrite Finished writing 8 bytes +0ms
- serialport/stream binding.write write finished +1ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +6ms
- serialport/bindings/poller received "readable" +10ms
- serialport/binding-abstract read +11ms
- serialport/bindings/unixRead Starting read +10ms
- serialport/bindings/unixRead Finished read { bytesRead: 15,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 15 } +12ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,10,97,8,0,8,221,221,221,221,221,221,221,221,107] +15ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,10,97,8,0,8,221,221,221,221,221,221,221,221,107] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 10 - 3 - 1 - 8 - ��������] - 107 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- SYS - osalNvRead - {"status":0,"len":8,"value":{"type":"Buffer","data":[221,221,221,221,221,221,221,221]}} +16ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- zigbee-herdsman:adapter:zStack:startZnp Item 'extendedPanID' is valid +17ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> UTIL - getDeviceInfo - {} +17ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,0,39,0,39] +17ms
- serialport/stream _write 5 bytes of data +3ms
- serialport/binding-abstract write 5 bytes +5ms
- serialport/bindings/unixWrite Starting write 5 bytes offset 0 bytesToWrite 5 +16ms
- serialport/stream _read reading { start: 160, toRead: 65376 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixWrite write returned: wrote 5 bytes +1ms
- serialport/bindings/unixWrite Finished writing 5 bytes +0ms
- serialport/stream binding.write write finished +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +7ms
- serialport/bindings/poller received "readable" +7ms
- serialport/binding-abstract read +8ms
- serialport/bindings/unixRead Starting read +7ms
- serialport/bindings/unixRead Finished read { bytesRead: 25,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 25 } +8ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,20,103,0,0,100,167,225,24,0,75,18,0,0,0,7,0,3,166,201,56,101,229,226,33] +14ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,20,103,0,0,100,167,225,24,0,75,18,0,0,0,7,0,3,166,201,56,101,229,226,33] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 20 - 3 - 7 - 0 - [d��K��8e��] - 33 +0ms
- PuTTY zigbee-herdsman:adapter:zStack:znp:SRSP <-- UTIL - getDeviceInfo - {"status":0,"ieeeaddr":"0x00124b0018e1a764","shortaddr":0,"devicetype":7,"devicestate":0,"numassocdevices":3,"assocdeviceslist":[51622,25912,58085]} +15ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- zigbee-herdsman:adapter:zStack:startZnp Start ZNP as coordinator... +15ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> ZDO - startupFromApp - {"startdelay":100} +15ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,2,37,64,100,0,3] +16ms
- serialport/stream _write 7 bytes of data +5ms
- serialport/binding-abstract write 7 bytes +6ms
- serialport/bindings/unixWrite Starting write 7 bytes offset 0 bytesToWrite 7 +14ms
- serialport/stream _read reading { start: 185, toRead: 65351 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixWrite write returned: wrote 7 bytes +2ms
- serialport/bindings/unixWrite Finished writing 7 bytes +0ms
- serialport/stream binding.write write finished +1ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +8ms
- serialport/bindings/poller received "readable" +1s
- serialport/binding-abstract read +1s
- serialport/bindings/unixRead Starting read +1s
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +1s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,101,64,0,36] +1s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,101,64,0,36] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 5 - 64 - [] - 36 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- ZDO - startupFromApp - {"status":0} +1s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- serialport/stream _read reading { start: 191, toRead: 65345 } +4ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +2ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,69,192,9,141] +4ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,69,192,9,141] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 2 - 5 - 192 - [ ] - 141 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - stateChangeInd - {"state":9} +2s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp ZNP started as coordinator +1s
- zigbee-herdsman:adapter:zStack:znp:SREQ --> ZDO - activeEpReq - {"dstaddr":0,"nwkaddrofinterest":0} +1s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,4,37,5,0,0,0,0,36] +1s
- serialport/stream _write 9 bytes of data +8ms
- serialport/binding-abstract write 9 bytes +10ms
- serialport/bindings/unixWrite Starting write 9 bytes offset 0 bytesToWrite 9 +1s
- serialport/stream _read reading { start: 197, toRead: 65339 } +1ms
- serialport/binding-abstract read +2ms
- serialport/bindings/unixRead Starting read +12ms
- serialport/bindings/unixWrite write returned: wrote 9 bytes +3ms
- serialport/bindings/unixWrite Finished writing 9 bytes +1ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +22ms
- serialport/bindings/poller received "readable" +2ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +3ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +6ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,101,5,0,97] +15ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,101,5,0,97] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 5 - 5 - [] - 97 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- ZDO - activeEpReq - {"status":0} +24ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 203, toRead: 65333 } +4ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead Finished read { bytesRead: 11,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 11 } +2ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,6,69,133,0,0,0,0,0,0,198] +5ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,6,69,133,0,0,0,0,0,0,198] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 6 - 2 - 5 - 133 - [] - 198 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - activeEpRsp - {"srcaddr":0,"status":0,"nwkaddr":0,"activeepcount":0,"activeeplist":[]} +25ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '1' +24ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":1,"appprofid":260} +23ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,1,4,1,5,0,0,0,0,0,44] +24ms
- serialport/stream _write 14 bytes of data +7ms
- serialport/binding-abstract write 14 bytes +10ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +20ms
- serialport/stream _read reading { start: 214, toRead: 65322 } +2ms
- serialport/binding-abstract read +2ms
- serialport/bindings/unixRead Starting read +11ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +3ms
- serialport/bindings/unixWrite Finished writing 14 bytes +0ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +21ms
- serialport/bindings/poller received "readable" +1ms
- serialport/binding-abstract read +3ms
- serialport/bindings/unixRead Starting read +2ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +3ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +12ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +21ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '2' +14ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":2,"appprofid":257} +14ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,2,1,1,5,0,0,0,0,0,42] +13ms
- serialport/stream _write 14 bytes of data +6ms
- serialport/binding-abstract write 14 bytes +8ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +10ms
- serialport/stream _read reading { start: 220, toRead: 65316 } +1ms
- serialport/binding-abstract read +2ms
- serialport/bindings/unixRead Starting read +9ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +3ms
- serialport/bindings/unixWrite Finished writing 14 bytes +0ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +13ms
- serialport/bindings/poller received "readable" +0ms
- serialport/binding-abstract read +4ms
- serialport/bindings/unixRead Starting read +2ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +3ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +11ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +13ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '3' +14ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":3,"appprofid":261} +13ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,3,5,1,5,0,0,0,0,0,47] +13ms
- serialport/stream _write 14 bytes of data +6ms
- serialport/binding-abstract write 14 bytes +7ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +10ms
- serialport/stream _read reading { start: 226, toRead: 65310 } +1ms
- serialport/binding-abstract read +2ms
- serialport/bindings/unixRead Starting read +9ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +3ms
- serialport/bindings/unixWrite Finished writing 14 bytes +1ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +13ms
- serialport/bindings/poller received "readable" +0ms
- serialport/binding-abstract read +4ms
- serialport/bindings/unixRead Starting read +2ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +3ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +11ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +13ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '4' +12ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":4,"appprofid":263} +13ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,4,7,1,5,0,0,0,0,0,42] +13ms
- serialport/stream _write 14 bytes of data +6ms
- serialport/binding-abstract write 14 bytes +7ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +9ms
- serialport/stream _read reading { start: 232, toRead: 65304 } +1ms
- serialport/binding-abstract read +2ms
- serialport/bindings/unixRead Starting read +8ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +3ms
- serialport/bindings/unixWrite Finished writing 14 bytes +0ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +12ms
- serialport/bindings/poller received "readable" +1ms
- serialport/binding-abstract read +3ms
- serialport/bindings/unixRead Starting read +2ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +3ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +10ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +13ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '5' +13ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":5,"appprofid":264} +13ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,5,8,1,5,0,0,0,0,0,36] +13ms
- serialport/stream _write 14 bytes of data +5ms
- serialport/binding-abstract write 14 bytes +8ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +10ms
- serialport/stream _read reading { start: 238, toRead: 65298 } +2ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +9ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +3ms
- serialport/bindings/unixWrite Finished writing 14 bytes +0ms
- serialport/stream binding.write write finished +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +12ms
- serialport/bindings/poller received "readable" +1ms
- serialport/binding-abstract read +17ms
- serialport/bindings/unixRead Starting read +15ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +17ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +24ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +25ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '6' +24ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":6,"appprofid":265} +24ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,6,9,1,5,0,0,0,0,0,38] +23ms
- serialport/stream _write 14 bytes of data +3ms
- serialport/binding-abstract write 14 bytes +5ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +20ms
- serialport/stream _read reading { start: 244, toRead: 65292 } +0ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +3ms
- serialport/bindings/unixWrite Finished writing 14 bytes +1ms
- serialport/stream binding.write write finished +4ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +3ms
- serialport/bindings/poller Polling for "readable" +23ms
- serialport/bindings/poller received "readable" +9ms
- serialport/binding-abstract read +14ms
- serialport/bindings/unixRead Starting read +11ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +7ms
- serialport/stream binding.read finished { bytesRead: 6 } +18ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +25ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +26ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '8' +26ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":8,"appprofid":260} +26ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,8,4,1,5,0,0,0,0,0,37] +26ms
- serialport/stream _write 14 bytes of data +4ms
- serialport/binding-abstract write 14 bytes +11ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +22ms
- serialport/stream _read reading { start: 250, toRead: 65286 } +0ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +2ms
- serialport/bindings/unixWrite Finished writing 14 bytes +1ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +15ms
- serialport/bindings/poller received "readable" +13ms
- serialport/binding-abstract read +16ms
- serialport/bindings/unixRead Starting read +14ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +16ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +22ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +24ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '11' +25ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":1024,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":1,"appoutclusterlist":[1280],"latencyreq":0,"endpoint":11,"appprofid":260} +24ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,11,36,0,11,4,1,0,4,0,0,0,1,0,5,33] +25ms
- serialport/stream _write 16 bytes of data +5ms
- serialport/binding-abstract write 16 bytes +7ms
- serialport/bindings/unixWrite Starting write 16 bytes offset 0 bytesToWrite 16 +22ms
- serialport/stream _read reading { start: 256, toRead: 65280 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +8ms
- serialport/bindings/unixWrite write returned: wrote 16 bytes +1ms
- serialport/bindings/unixWrite Finished writing 16 bytes +0ms
- serialport/stream binding.write write finished +1ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +11ms
- serialport/bindings/poller received "readable" +1ms
- serialport/binding-abstract read +4ms
- serialport/bindings/unixRead Starting read +2ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +3ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +8ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +9ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:startZnp Registering endpoint '110' +8ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - register - {"appdeviceid":5,"appdevver":0,"appnuminclusters":0,"appinclusterlist":[],"appnumoutclusters":0,"appoutclusterlist":[],"latencyreq":0,"endpoint":110,"appprofid":260} +8ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,9,36,0,110,4,1,5,0,0,0,0,0,67] +8ms
- serialport/stream _write 14 bytes of data +3ms
- serialport/binding-abstract write 14 bytes +3ms
- serialport/bindings/unixWrite Starting write 14 bytes offset 0 bytesToWrite 14 +7ms
- serialport/stream _read reading { start: 262, toRead: 65274 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixWrite write returned: wrote 14 bytes +1ms
- serialport/bindings/unixWrite Finished writing 14 bytes +0ms
- serialport/stream binding.write write finished +1ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +7ms
- serialport/bindings/poller received "readable" +2ms
- serialport/binding-abstract read +4ms
- serialport/bindings/unixRead Starting read +3ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +4ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,0,0,101] +8ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,0,0,101] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 0 - [] - 101 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - register - {"status":0} +8ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:controller:log Started with result 'resumed' +3s
- zigbee-herdsman:controller:log Injected database: true, adapter: true +0ms
- zigbee2mqtt:info 2019-12-08T15:38:29: zigbee-herdsman started
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Coordinator firmware version: '{"type":"zStack12","meta":{"transportrev":2,"product":0,"majorrel":2,"minorrel":6,"maintrel":3,"revision":20190608}}'
- winston:file written true false
- zigbee-herdsman:adapter:zStack:znp:SREQ --> ZDO - extNwkInfo - {} +20ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,0,37,80,117] +20ms
- serialport/stream _write 5 bytes of data +14ms
- serialport/binding-abstract write 5 bytes +15ms
- serialport/bindings/unixWrite Starting write 5 bytes offset 0 bytesToWrite 5 +18ms
- serialport/stream _read reading { start: 268, toRead: 65268 } +1ms
- serialport/binding-abstract read +1ms
- winston:file logged 686 info 2019-12-08T15:38:29: zigbee-herdsman started
- winston:file logged 862 info 2019-12-08T15:38:29: Coordinator firmware version: '{"type":"zStack12","meta":{"transportrev":2,"product":0,"majorrel":2,"minorrel":6,"maintrel":3,"revision":20190608}}'
- serialport/bindings/unixRead Starting read +16ms
- serialport/bindings/unixWrite write returned: wrote 5 bytes +3ms
- serialport/bindings/unixWrite Finished writing 5 bytes +0ms
- serialport/stream binding.write write finished +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +18ms
- serialport/bindings/poller received "readable" +1ms
- serialport/binding-abstract read +4ms
- serialport/bindings/unixRead Starting read +2ms
- serialport/bindings/unixRead Finished read { bytesRead: 29,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 29 } +3ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,24,101,80,0,0,9,98,26,0,0,221,221,221,221,221,221,221,221,0,0,0,0,0,0,0,0,11,87] +18ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,24,101,80,0,0,9,98,26,0,0,221,221,221,221,221,221,221,221,0,0,0,0,0,0,0,0,11,87] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 24 - 3 - 5 - 80 - [ b��������
- ] - 87 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- ZDO - extNwkInfo - {"shortaddr":0,"devstate":9,"panid":6754,"parentaddr":0,"extendedpanid":"0xdddddddddddddddd","parentextaddr":"0x0000000000000000","channel":11} +20ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- zigbee2mqtt:debug 2019-12-08T15:38:29: Zigbee network parameters: {"panID":6754,"extendedPanID":"0xdddddddddddddddd","channel":11}
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Currently 25 devices are joined:
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: PIR1 (0x00158d000152fbe0): RTCGQ01LM - Xiaomi MiJia human body movement sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: IKEA Remote (0xd0cf5efffe22c536): E1524/E1810 - IKEA TRADFRI remote control (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Switch1 (0x00158d0001b8f8f9): WXKG11LM - Xiaomi Aqara wireless switch (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: MCS1 (0x00158d0001835449): MCCGQ01LM - Xiaomi MiJia door & window contact sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Lamp_FF_Hall (0x000d6ffffea6e1de): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Flood_GF_Garden (0x000d6ffffec7c0a8): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Temp_GF_TechCupboard (0x00158d00018256f2): WSDCGQ01LM - Xiaomi MiJia temperature & humidity sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: 0x14b457fffe74b366 (0x14b457fffe74b366): LED1836G9 - IKEA TRADFRI LED bulb E27 806 lumen, dimmable, warm white (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: PIR_SF_Hall (0x00158d0001a33ac8): RTCGQ11LM - Xiaomi Aqara human body movement and illuminance sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: PIR_FF_LivingRoom (0x00158d000155b510): RTCGQ01LM - Xiaomi MiJia human body movement sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Temp_FF_LivingRoom (0x00158d000182481a): WSDCGQ01LM - Xiaomi MiJia temperature & humidity sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: MCS_FF_BedroomLeft (0x00158d0001ab23c1): MCCGQ11LM - Xiaomi Aqara door & window contact sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: MCS_FF_BedroomRight (0x00158d0001ab743a): MCCGQ11LM - Xiaomi Aqara door & window contact sensor (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Bulb_FF_LivingRoom1 (0xd0cf5efffeda2156): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Bulb_FF_LivingRoom2 (0xd0cf5efffed833d7): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Bulb_FF_LivingRoom3 (0x90fd9ffffe2a1e72): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Bulb_FF_LivingRoom4 (0x90fd9ffffe152a4e): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: WallSwitch_FF_Bedroom (0x00158d0001576601): WXKG03LM - Xiaomi Aqara single key wireless wall switch (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: CupboardSwitch_FF_Bedroom (0x00158d00015cc89e): WXKG01LM - Xiaomi MiJia wireless switch (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Switch_GF_Kitchen_LampsFlood (0x00158d00027c27f8): WXKG02LM - Xiaomi Aqara double key wireless wall switch (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Switch_SF_SpareRoom_Pinball (0x00158d000186df2e): WXKG01LM - Xiaomi MiJia wireless switch (EndDevice)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Fan_GF_Hall (0x000d6ffffef31702): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Lamp_SF_Hall (0x000d6ffffee3d8db): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: IKEA_Test_Skt (0x000d6ffffebccc86): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: IKEA_LR_Remote (0x14b457fffe5d51f3): E1743 - IKEA TRADFRI ON/OFF switch (EndDevice)
- winston:file written true false
- zigbee2mqtt:warn 2019-12-08T15:38:29: `permit_join` set to `true` in configuration.yaml.
- winston:file written true false
- zigbee2mqtt:warn 2019-12-08T15:38:29: Allowing new devices to join.
- winston:file written true false
- zigbee2mqtt:warn 2019-12-08T15:38:29: Set `permit_join` to `false` once you joined all devices.
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:29: Zigbee: allowing new devices to join.
- winston:file written true false
- zigbee-herdsman:controller:log Permit joining +53ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> ZDO - mgmtPermitJoinReq - {"addrmode":15,"dstaddr":65532,"duration":254,"tcsignificance":0} +43ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,5,37,54,15,252,255,254,0,228] +43ms
- serialport/stream _write 10 bytes of data +37ms
- serialport/binding-abstract write 10 bytes +38ms
- zigbee2mqtt:info 2019-12-08T15:38:29: Connecting to MQTT server at mqtt://127.0.0.1
- winston:file written true false
- serialport/bindings/unixWrite Starting write 10 bytes offset 0 bytesToWrite 10 +152ms
- serialport/stream _read reading { start: 297, toRead: 65239 } +121ms
- serialport/binding-abstract read +122ms
- winston:file logged 981 debug 2019-12-08T15:38:29: Zigbee network parameters: {"panID":6754,"extendedPanID":"0xdddddddddddddddd","channel":11}
- winston:file logged 1041 info 2019-12-08T15:38:29: Currently 25 devices are joined:
- winston:file logged 1159 info 2019-12-08T15:38:29: PIR1 (0x00158d000152fbe0): RTCGQ01LM - Xiaomi MiJia human body movement sensor (EndDevice)
- winston:file logged 1274 info 2019-12-08T15:38:29: IKEA Remote (0xd0cf5efffe22c536): E1524/E1810 - IKEA TRADFRI remote control (EndDevice)
- winston:file logged 1383 info 2019-12-08T15:38:29: Switch1 (0x00158d0001b8f8f9): WXKG11LM - Xiaomi Aqara wireless switch (EndDevice)
- winston:file logged 1503 info 2019-12-08T15:38:29: MCS1 (0x00158d0001835449): MCCGQ01LM - Xiaomi MiJia door & window contact sensor (EndDevice)
- winston:file logged 1616 info 2019-12-08T15:38:29: Lamp_FF_Hall (0x000d6ffffea6e1de): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file logged 1732 info 2019-12-08T15:38:29: Flood_GF_Garden (0x000d6ffffec7c0a8): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file logged 1870 info 2019-12-08T15:38:29: Temp_GF_TechCupboard (0x00158d00018256f2): WSDCGQ01LM - Xiaomi MiJia temperature & humidity sensor (EndDevice)
- winston:file logged 2017 info 2019-12-08T15:38:29: 0x14b457fffe74b366 (0x14b457fffe74b366): LED1836G9 - IKEA TRADFRI LED bulb E27 806 lumen, dimmable, warm white (Router)
- winston:file logged 2158 info 2019-12-08T15:38:29: PIR_SF_Hall (0x00158d0001a33ac8): RTCGQ11LM - Xiaomi Aqara human body movement and illuminance sensor (EndDevice)
- winston:file logged 2289 info 2019-12-08T15:38:29: PIR_FF_LivingRoom (0x00158d000155b510): RTCGQ01LM - Xiaomi MiJia human body movement sensor (EndDevice)
- winston:file logged 2425 info 2019-12-08T15:38:29: Temp_FF_LivingRoom (0x00158d000182481a): WSDCGQ01LM - Xiaomi MiJia temperature & humidity sensor (EndDevice)
- winston:file logged 2559 info 2019-12-08T15:38:29: MCS_FF_BedroomLeft (0x00158d0001ab23c1): MCCGQ11LM - Xiaomi Aqara door & window contact sensor (EndDevice)
- winston:file logged 2694 info 2019-12-08T15:38:29: MCS_FF_BedroomRight (0x00158d0001ab743a): MCCGQ11LM - Xiaomi Aqara door & window contact sensor (EndDevice)
- winston:file logged 2831 info 2019-12-08T15:38:29: Bulb_FF_LivingRoom1 (0xd0cf5efffeda2156): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file logged 2968 info 2019-12-08T15:38:29: Bulb_FF_LivingRoom2 (0xd0cf5efffed833d7): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file logged 3105 info 2019-12-08T15:38:29: Bulb_FF_LivingRoom3 (0x90fd9ffffe2a1e72): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file logged 3242 info 2019-12-08T15:38:29: Bulb_FF_LivingRoom4 (0x90fd9ffffe152a4e): LED1650R5 - IKEA TRADFRI LED bulb GU10 400 lumen, dimmable (Router)
- winston:file logged 3381 info 2019-12-08T15:38:29: WallSwitch_FF_Bedroom (0x00158d0001576601): WXKG03LM - Xiaomi Aqara single key wireless wall switch (EndDevice)
- winston:file logged 3508 info 2019-12-08T15:38:29: CupboardSwitch_FF_Bedroom (0x00158d00015cc89e): WXKG01LM - Xiaomi MiJia wireless switch (EndDevice)
- winston:file logged 3654 info 2019-12-08T15:38:29: Switch_GF_Kitchen_LampsFlood (0x00158d00027c27f8): WXKG02LM - Xiaomi Aqara double key wireless wall switch (EndDevice)
- winston:file logged 3783 info 2019-12-08T15:38:29: Switch_SF_SpareRoom_Pinball (0x00158d000186df2e): WXKG01LM - Xiaomi MiJia wireless switch (EndDevice)
- winston:file logged 3895 info 2019-12-08T15:38:29: Fan_GF_Hall (0x000d6ffffef31702): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file logged 4008 info 2019-12-08T15:38:29: Lamp_SF_Hall (0x000d6ffffee3d8db): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file logged 4122 info 2019-12-08T15:38:29: IKEA_Test_Skt (0x000d6ffffebccc86): E1603/E1702 - IKEA TRADFRI control outlet (Router)
- winston:file logged 4233 info 2019-12-08T15:38:29: IKEA_LR_Remote (0x14b457fffe5d51f3): E1743 - IKEA TRADFRI ON/OFF switch (EndDevice)
- winston:file logged 4312 warn 2019-12-08T15:38:29: `permit_join` set to `true` in configuration.yaml.
- winston:file logged 4369 warn 2019-12-08T15:38:29: Allowing new devices to join.
- winston:file logged 4454 warn 2019-12-08T15:38:29: Set `permit_join` to `false` once you joined all devices.
- winston:file logged 4519 info 2019-12-08T15:38:29: Zigbee: allowing new devices to join.
- winston:file logged 4592 info 2019-12-08T15:38:29: Connecting to MQTT server at mqtt://127.0.0.1
- serialport/bindings/unixRead Starting read +171ms
- serialport/bindings/unixWrite write returned: wrote 10 bytes +22ms
- serialport/bindings/unixWrite Finished writing 10 bytes +1ms
- serialport/stream binding.write write finished +14ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +2ms
- serialport/stream binding.read finished { bytesRead: 6 } +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,101,54,0,82] +172ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,101,54,0,82] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 5 - 54 - [] - 82 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- ZDO - mgmtPermitJoinReq - {"status":0} +172ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> UTIL - ledControl - {"ledid":3,"mode":0} +138ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,2,39,10,3,0,44] +138ms
- serialport/stream _write 7 bytes of data +3ms
- serialport/binding-abstract write 7 bytes +16ms
- serialport/bindings/unixWrite Starting write 7 bytes offset 0 bytesToWrite 7 +3ms
- serialport/stream _read reading { start: 303, toRead: 65233 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +4ms
- serialport/bindings/unixWrite write returned: wrote 7 bytes +4ms
- serialport/bindings/unixWrite Finished writing 7 bytes +0ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +3ms
- serialport/stream binding.read finished { bytesRead: 8 } +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,69,182,0,0,0,240] +6ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,69,182,0,0,0,240] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 5 - 182 - [] - 240 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - mgmtPermitJoinRsp - {"srcaddr":0,"status":0} +345ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- serialport/stream _read reading { start: 311, toRead: 65225 } +2ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +3ms
- zigbee2mqtt:info 2019-12-08T15:38:30: Connected to MQTT server
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/bridge/state', payload 'online'
- winston:file written true false
- winston:file logged 4644 info 2019-12-08T15:38:30: Connected to MQTT server
- winston:file logged 4736 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/bridge/state', payload 'online'
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/PIR1', payload '{"occupancy":false,"linkquality":99,"battery":100,"voltage":3015,"device":{"friendlyName":"PIR1","ieeeAddr":"0x00158d000152fbe0","networkAddress":18466,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/IKEA Remote', payload '{"battery":34,"linkquality":39,"device":{"friendlyName":"IKEA Remote","ieeeAddr":"0xd0cf5efffe22c536","networkAddress":17502,"type":"EndDevice","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Battery","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Switch1', payload '{"battery":100,"voltage":3055,"linkquality":141,"device":{"friendlyName":"Switch1","ieeeAddr":"0x00158d0001b8f8f9","networkAddress":20341,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/MCS1', payload '{"contact":false,"linkquality":84,"battery":100,"voltage":3035,"device":{"friendlyName":"MCS1","ieeeAddr":"0x00158d0001835449","networkAddress":14841,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Lamp_FF_Hall', payload '{"state":"OFF","linkquality":34,"device":{"friendlyName":"Lamp_FF_Hall","ieeeAddr":"0x000d6ffffea6e1de","networkAddress":42932,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Flood_GF_Garden', payload '{"state":"OFF","linkquality":141,"device":{"friendlyName":"Flood_GF_Garden","ieeeAddr":"0x000d6ffffec7c0a8","networkAddress":18120,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Temp_GF_TechCupboard', payload '{"temperature":25.37,"linkquality":126,"humidity":33.13,"battery":100,"voltage":3015,"device":{"friendlyName":"Temp_GF_TechCupboard","ieeeAddr":"0x00158d00018256f2","networkAddress":20582,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:error 2019-12-08T15:38:30: '0x14b457fffe74b366' does not exist, skipping publish
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/PIR_SF_Hall', payload '{"illuminance":2,"linkquality":141,"occupancy":false,"battery":100,"voltage":3035,"device":{"friendlyName":"PIR_SF_Hall","ieeeAddr":"0x00158d0001a33ac8","networkAddress":52882,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/PIR_FF_LivingRoom', payload '{"occupancy":false,"linkquality":89,"battery":100,"voltage":3015,"device":{"friendlyName":"PIR_FF_LivingRoom","ieeeAddr":"0x00158d000155b510","networkAddress":7973,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Temp_FF_LivingRoom', payload '{"temperature":21.93,"linkquality":78,"humidity":43.94,"battery":100,"voltage":3005,"device":{"friendlyName":"Temp_FF_LivingRoom","ieeeAddr":"0x00158d000182481a","networkAddress":53073,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/MCS_FF_BedroomLeft', payload '{"battery":100,"voltage":3035,"contact":true,"linkquality":39,"device":{"friendlyName":"MCS_FF_BedroomLeft","ieeeAddr":"0x00158d0001ab23c1","networkAddress":46892,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/MCS_FF_BedroomRight', payload '{"battery":100,"voltage":3025,"contact":true,"linkquality":141,"device":{"friendlyName":"MCS_FF_BedroomRight","ieeeAddr":"0x00158d0001ab743a","networkAddress":41270,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom1', payload '{"state":"OFF","linkquality":34,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom1","ieeeAddr":"0xd0cf5efffeda2156","networkAddress":31471,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom2', payload '{"state":"OFF","linkquality":42,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom2","ieeeAddr":"0xd0cf5efffed833d7","networkAddress":63138,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom3', payload '{"state":"OFF","linkquality":47,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom3","ieeeAddr":"0x90fd9ffffe2a1e72","networkAddress":4415,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom4', payload '{"state":"OFF","linkquality":36,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom4","ieeeAddr":"0x90fd9ffffe152a4e","networkAddress":36881,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/WallSwitch_FF_Bedroom', payload '{"linkquality":73,"battery":100,"voltage":3015,"device":{"friendlyName":"WallSwitch_FF_Bedroom","ieeeAddr":"0x00158d0001576601","networkAddress":58085,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/CupboardSwitch_FF_Bedroom', payload '{"linkquality":141,"battery":100,"voltage":3052,"device":{"friendlyName":"CupboardSwitch_FF_Bedroom","ieeeAddr":"0x00158d00015cc89e","networkAddress":60009,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Switch_GF_Kitchen_LampsFlood', payload '{"linkquality":47,"battery":100,"voltage":3025,"device":{"friendlyName":"Switch_GF_Kitchen_LampsFlood","ieeeAddr":"0x00158d00027c27f8","networkAddress":25912,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Switch_SF_SpareRoom_Pinball', payload '{"linkquality":31,"battery":100,"voltage":3032,"device":{"friendlyName":"Switch_SF_SpareRoom_Pinball","ieeeAddr":"0x00158d000186df2e","networkAddress":11746,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Fan_GF_Hall', payload '{"state":"ON","linkquality":141,"device":{"friendlyName":"Fan_GF_Hall","ieeeAddr":"0x000d6ffffef31702","networkAddress":50524,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Lamp_SF_Hall', payload '{"state":"OFF","linkquality":141,"device":{"friendlyName":"Lamp_SF_Hall","ieeeAddr":"0x000d6ffffee3d8db","networkAddress":37666,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/IKEA_Test_Skt', payload '{"state":"ON","linkquality":39,"device":{"friendlyName":"IKEA_Test_Skt","ieeeAddr":"0x000d6ffffebccc86","networkAddress":11686,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/IKEA_LR_Remote', payload '{"battery":87,"linkquality":47,"device":{"friendlyName":"IKEA_LR_Remote","ieeeAddr":"0x14b457fffe5d51f3","networkAddress":44110,"type":"EndDevice","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Battery","applicationVersion":34,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20190410","softwareBuildID":"2.2.008"}}'
- winston:file written true false
- winston:file logged 5058 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/PIR1', payload '{"occupancy":false,"linkquality":99,"battery":100,"voltage":3015,"device":{"friendlyName":"PIR1","ieeeAddr":"0x00158d000152fbe0","networkAddress":18466,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 5497 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/IKEA Remote', payload '{"battery":34,"linkquality":39,"device":{"friendlyName":"IKEA Remote","ieeeAddr":"0xd0cf5efffe22c536","networkAddress":17502,"type":"EndDevice","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Battery","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file logged 5808 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Switch1', payload '{"battery":100,"voltage":3055,"linkquality":141,"device":{"friendlyName":"Switch1","ieeeAddr":"0x00158d0001b8f8f9","networkAddress":20341,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 6128 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/MCS1', payload '{"contact":false,"linkquality":84,"battery":100,"voltage":3035,"device":{"friendlyName":"MCS1","ieeeAddr":"0x00158d0001835449","networkAddress":14841,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 6580 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Lamp_FF_Hall', payload '{"state":"OFF","linkquality":34,"device":{"friendlyName":"Lamp_FF_Hall","ieeeAddr":"0x000d6ffffea6e1de","networkAddress":42932,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file logged 7039 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Flood_GF_Garden', payload '{"state":"OFF","linkquality":141,"device":{"friendlyName":"Flood_GF_Garden","ieeeAddr":"0x000d6ffffec7c0a8","networkAddress":18120,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file logged 7413 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Temp_GF_TechCupboard', payload '{"temperature":25.37,"linkquality":126,"humidity":33.13,"battery":100,"voltage":3015,"device":{"friendlyName":"Temp_GF_TechCupboard","ieeeAddr":"0x00158d00018256f2","networkAddress":20582,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 7494 error 2019-12-08T15:38:30: '0x14b457fffe74b366' does not exist, skipping publish
- winston:file logged 7847 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/PIR_SF_Hall', payload '{"illuminance":2,"linkquality":141,"occupancy":false,"battery":100,"voltage":3035,"device":{"friendlyName":"PIR_SF_Hall","ieeeAddr":"0x00158d0001a33ac8","networkAddress":52882,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 8194 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/PIR_FF_LivingRoom', payload '{"occupancy":false,"linkquality":89,"battery":100,"voltage":3015,"device":{"friendlyName":"PIR_FF_LivingRoom","ieeeAddr":"0x00158d000155b510","networkAddress":7973,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 8563 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Temp_FF_LivingRoom', payload '{"temperature":21.93,"linkquality":78,"humidity":43.94,"battery":100,"voltage":3005,"device":{"friendlyName":"Temp_FF_LivingRoom","ieeeAddr":"0x00158d000182481a","networkAddress":53073,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 8910 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/MCS_FF_BedroomLeft', payload '{"battery":100,"voltage":3035,"contact":true,"linkquality":39,"device":{"friendlyName":"MCS_FF_BedroomLeft","ieeeAddr":"0x00158d0001ab23c1","networkAddress":46892,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 9260 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/MCS_FF_BedroomRight', payload '{"battery":100,"voltage":3025,"contact":true,"linkquality":141,"device":{"friendlyName":"MCS_FF_BedroomRight","ieeeAddr":"0x00158d0001ab743a","networkAddress":41270,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 9383 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 9866 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom1', payload '{"state":"OFF","linkquality":34,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom1","ieeeAddr":"0xd0cf5efffeda2156","networkAddress":31471,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file logged 9989 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 10472 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom2', payload '{"state":"OFF","linkquality":42,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom2","ieeeAddr":"0xd0cf5efffed833d7","networkAddress":63138,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file logged 10595 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 11077 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom3', payload '{"state":"OFF","linkquality":47,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom3","ieeeAddr":"0x90fd9ffffe2a1e72","networkAddress":4415,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file logged 11200 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 11683 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom4', payload '{"state":"OFF","linkquality":36,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom4","ieeeAddr":"0x90fd9ffffe152a4e","networkAddress":36881,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file logged 12021 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/WallSwitch_FF_Bedroom', payload '{"linkquality":73,"battery":100,"voltage":3015,"device":{"friendlyName":"WallSwitch_FF_Bedroom","ieeeAddr":"0x00158d0001576601","networkAddress":58085,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 12368 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/CupboardSwitch_FF_Bedroom', payload '{"linkquality":141,"battery":100,"voltage":3052,"device":{"friendlyName":"CupboardSwitch_FF_Bedroom","ieeeAddr":"0x00158d00015cc89e","networkAddress":60009,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 12720 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Switch_GF_Kitchen_LampsFlood', payload '{"linkquality":47,"battery":100,"voltage":3025,"device":{"friendlyName":"Switch_GF_Kitchen_LampsFlood","ieeeAddr":"0x00158d00027c27f8","networkAddress":25912,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 13070 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Switch_SF_SpareRoom_Pinball', payload '{"linkquality":31,"battery":100,"voltage":3032,"device":{"friendlyName":"Switch_SF_SpareRoom_Pinball","ieeeAddr":"0x00158d000186df2e","networkAddress":11746,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file logged 13520 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Fan_GF_Hall', payload '{"state":"ON","linkquality":141,"device":{"friendlyName":"Fan_GF_Hall","ieeeAddr":"0x000d6ffffef31702","networkAddress":50524,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file logged 13973 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/Lamp_SF_Hall', payload '{"state":"OFF","linkquality":141,"device":{"friendlyName":"Lamp_SF_Hall","ieeeAddr":"0x000d6ffffee3d8db","networkAddress":37666,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file logged 14426 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/IKEA_Test_Skt', payload '{"state":"ON","linkquality":39,"device":{"friendlyName":"IKEA_Test_Skt","ieeeAddr":"0x000d6ffffebccc86","networkAddress":11686,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":32,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20180828","softwareBuildID":"2.0.019"}}'
- winston:file logged 14871 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/IKEA_LR_Remote', payload '{"battery":87,"linkquality":47,"device":{"friendlyName":"IKEA_LR_Remote","ieeeAddr":"0x14b457fffe5d51f3","networkAddress":44110,"type":"EndDevice","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Battery","applicationVersion":34,"stackVersion":98,"zclVersion":3,"hardwareVersion":1,"dateCode":"20190410","softwareBuildID":"2.2.008"}}'
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +163ms
- serialport/stream binding.read finished { bytesRead: 6 } +164ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,103,10,0,108] +165ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,103,10,0,108] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 7 - 10 - [] - 108 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- UTIL - ledControl - {"status":0} +174ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 317, toRead: 65219 } +3ms
- serialport/binding-abstract read +167ms
- serialport/bindings/unixRead Starting read +4ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +4ms
- serialport/bindings/poller Polling for "readable" +355ms
- zigbee2mqtt:info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/bridge/config', payload '{"version":"1.7.1","commit":"b459c35","coordinator":{"type":"zStack12","meta":{"transportrev":2,"product":0,"majorrel":2,"minorrel":6,"maintrel":3,"revision":20190608}},"log_level":"debug","permit_join":true}'
- winston:file written true false
- winston:file logged 15166 info 2019-12-08T15:38:30: MQTT publish: topic 'zigbee2mqtt/bridge/config', payload '{"version":"1.7.1","commit":"b459c35","coordinator":{"type":"zStack12","meta":{"transportrev":2,"product":0,"majorrel":2,"minorrel":6,"maintrel":3,"revision":20190608}},"log_level":"debug","permit_join":true}'
- serialport/bindings/poller received "readable" +3s
- serialport/binding-abstract read +3s
- serialport/bindings/unixRead Starting read +3s
- serialport/bindings/unixRead Finished read { bytesRead: 10,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 10 } +3s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,5,69,196,200,70,1,92,197,146] +3s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,5,69,196,200,70,1,92,197,146] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 5 - 2 - 5 - 196 - [�F\�] - 146 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":18120,"relaycount":1,"relaylist":[50524]} +3s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +10ms
- serialport/stream _read reading { start: 327, toRead: 65209 } +12ms
- serialport/binding-abstract read +15ms
- serialport/bindings/unixRead Starting read +14ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +18ms
- serialport/bindings/poller received "readable" +30ms
- serialport/binding-abstract read +32ms
- serialport/bindings/unixRead Starting read +32ms
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 32 } +35ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,8,0,200,70,1,1,0,144,0,153,228,12,0,0,7,8,53,10,0,0,32,254,92,197,28,210] +37ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,8,0,200,70,1,1,0,144,0,153,228,12,0,0,7,8,53,10,0,0,32,254,92,197,28,210] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 27 - 2 - 4 - 129 - �F���
- 5
- zigbee-herdsman:adapter:zStack:unpi:parser �\�] - 210 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":8,"srcaddr":18120,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":144,"securityuse":0,"timestamp":844953,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[8,53,10,0,0,32,254]}} +48ms
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false},"transactionSequenceNumber":53,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":32,"attrData":254}],"Cluster":{"ID":8,"attributes":{"currentLevel":{"ID":0,"type":32,"name":"currentLevel"},"remainingTime":{"ID":1,"type":33,"name":"remainingTime"},"onOffTransitionTime":{"ID":16,"type":33,"name":"onOffTransitionTime"},"onLevel":{"ID":17,"type":32,"name":"onLevel"},"onTransitionTime":{"ID":18,"type":33,"name":"onTransitionTime"},"offTransitionTime":{"ID":19,"type":33,"name":"offTransitionTime"},"defaultMoveRate":{"ID":20,"type":33,"name":"defaultMoveRate"}},"name":"genLevelCtrl","commands":{"moveToLevel":{"ID":0,"parameters":[{"name":"level","type":32},{"name":"transtime","type":33}],"name":"moveToLevel"},"move":{"ID":1,"parameters":[{"name":"movemode","type":32},{"name":"rate","type":32}],"name":"move"},"step":{"ID":2,"parameters":[{"name":"stepmode","type":32},{"name":"stepsize","type":32},{"name":"transtime","type":33}],"name":"step"},"stop":{"ID":3,"parameters":[],"name":"stop"},"moveToLevelWithOnOff":{"ID":4,"parameters":[{"name":"level","type":32},{"name":"transtime","type":33}],"name":"moveToLevelWithOnOff"},"moveWithOnOff":{"ID":5,"parameters":[{"name":"movemode","type":32},{"name":"rate","type":32}],"name":"moveWithOnOff"},"stepWithOnOff":{"ID":6,"parameters":[{"name":"stepmode","type":32},{"name":"stepsize","type":32},{"name":"transtime","type":33}],"name":"stepWithOnOff"},"stopWithOnOff":{"ID":7,"parameters":[],"name":"stopWithOnOff"}},"commandsResponse":{}}},"networkAddress":18120,"endpoint":1,"linkquality":144,"groupID":0}' +3s
- zigbee2mqtt:debug 2019-12-08T15:38:33: Received Zigbee message from 'Flood_GF_Garden', type 'attributeReport', cluster 'genLevelCtrl', data '{"currentLevel":254}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - dataRequest - {"dstaddr":18120,"destendpoint":1,"srcendpoint":1,"clusterid":8,"transid":1,"options":0,"radius":30,"len":5,"data":{"type":"Buffer","data":[24,53,11,10,0]}} +3s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,15,36,1,200,70,1,1,8,0,1,0,30,5,24,53,11,10,0,154] +3s
- serialport/stream _write 20 bytes of data +47ms
- serialport/binding-abstract write 20 bytes +50ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +47ms
- serialport/bindings/unixWrite Starting write 20 bytes offset 0 bytesToWrite 20 +3s
- winston:file logged 15348 debug 2019-12-08T15:38:33: Received Zigbee message from 'Flood_GF_Garden', type 'attributeReport', cluster 'genLevelCtrl', data '{"currentLevel":254}' from endpoint 1 with groupID 0
- serialport/stream _read reading { start: 359, toRead: 65177 } +7ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +55ms
- serialport/bindings/unixWrite write returned: wrote 20 bytes +5ms
- serialport/bindings/unixWrite Finished writing 20 bytes +0ms
- serialport/stream binding.write write finished +1ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +57ms
- serialport/bindings/poller received "readable" +6ms
- serialport/binding-abstract read +7ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +7ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,1,0,100] +13ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,1,0,100] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 1 - [] - 100 +0ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - dataRequest - {"status":0} +3s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- serialport/stream _read reading { start: 365, toRead: 65171 } +2ms
- serialport/binding-abstract read +3ms
- serialport/bindings/unixRead Starting read +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +0ms
- serialport/bindings/poller Polling for "readable" +4ms
- serialport/bindings/poller received "readable" +4ms
- serialport/binding-abstract read +5ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 8 } +6ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,68,128,0,1,1,199] +7ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,68,128,0,1,1,199] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 4 - 128 - [] - 199 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - dataConfirm - {"status":0,"endpoint":1,"transid":1} +68ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 373, toRead: 65163 } +2ms
- serialport/binding-abstract read +3ms
- serialport/bindings/unixRead Starting read +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +4ms
- serialport/bindings/poller received "readable" +4s
- serialport/binding-abstract read +4s
- serialport/bindings/unixRead Starting read +4s
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +4s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,69,196,92,197,0,27] +4s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,69,196,92,197,0,27] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 5 - 196 - [\�] - 27 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - srcRtgInd - {"dstaddr":50524,"relaycount":0,"relaylist":[]} +4s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 381, toRead: 65155 } +3ms
- serialport/binding-abstract read +5ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +0ms
- serialport/bindings/poller Polling for "readable" +8ms
- serialport/bindings/poller received "readable" +36ms
- serialport/binding-abstract read +39ms
- serialport/bindings/unixRead Starting read +38ms
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 32 } +40ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,8,0,92,197,1,1,0,144,0,217,17,13,0,0,7,8,25,10,0,0,32,254,92,197,29,92] +42ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,8,0,92,197,1,1,0,144,0,217,17,13,0,0,7,8,25,10,0,0,32,254,92,197,29,92] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser �\�] - 92 +1ms 2 - 4 - 129 - \���
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":8,"srcaddr":50524,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":144,"securityuse":0,"timestamp":856537,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[8,25,10,0,0,32,254]}} +43ms
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false},"transactionSequenceNumber":25,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":32,"attrData":254}],"Cluster":{"ID":8,"attributes":{"currentLevel":{"ID":0,"type":32,"name":"currentLevel"},"remainingTime":{"ID":1,"type":33,"name":"remainingTime"},"onOffTransitionTime":{"ID":16,"type":33,"name":"onOffTransitionTime"},"onLevel":{"ID":17,"type":32,"name":"onLevel"},"onTransitionTime":{"ID":18,"type":33,"name":"onTransitionTime"},"offTransitionTime":{"ID":19,"type":33,"name":"offTransitionTime"},"defaultMoveRate":{"ID":20,"type":33,"name":"defaultMoveRate"}},"name":"genLevelCtrl","commands":{"moveToLevel":{"ID":0,"parameters":[{"name":"level","type":32},{"name":"transtime","type":33}],"name":"moveToLevel"},"move":{"ID":1,"parameters":[{"name":"movemode","type":32},{"name":"rate","type":32}],"name":"move"},"step":{"ID":2,"parameters":[{"name":"stepmode","type":32},{"name":"stepsize","type":32},{"name":"transtime","type":33}],"name":"step"},"stop":{"ID":3,"parameters":[],"name":"stop"},"moveToLevelWithOnOff":{"ID":4,"parameters":[{"name":"level","type":32},{"name":"transtime","type":33}],"name":"moveToLevelWithOnOff"},"moveWithOnOff":{"ID":5,"parameters":[{"name":"movemode","type":32},{"name":"rate","type":32}],"name":"moveWithOnOff"},"stepWithOnOff":{"ID":6,"parameters":[{"name":"stepmode","type":32},{"name":"stepsize","type":32},{"name":"transtime","type":33}],"name":"stepWithOnOff"},"stopWithOnOff":{"ID":7,"parameters":[],"name":"stopWithOnOff"}},"commandsResponse":{}}},"networkAddress":50524,"endpoint":1,"linkquality":144,"groupID":0}' +4s
- zigbee2mqtt:debug 2019-12-08T15:38:36: Received Zigbee message from 'Fan_GF_Hall', type 'attributeReport', cluster 'genLevelCtrl', data '{"currentLevel":254}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - dataRequest - {"dstaddr":50524,"destendpoint":1,"srcendpoint":1,"clusterid":8,"transid":2,"options":0,"radius":30,"len":5,"data":{"type":"Buffer","data":[24,25,11,10,0]}} +4s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,15,36,1,92,197,1,1,8,0,2,0,30,5,24,25,11,10,0,162] +4s
- serialport/stream _write 20 bytes of data +14ms
- serialport/binding-abstract write 20 bytes +15ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +13ms
- serialport/bindings/unixWrite Starting write 20 bytes offset 0 bytesToWrite 20 +4s
- winston:file logged 15526 debug 2019-12-08T15:38:36: Received Zigbee message from 'Fan_GF_Hall', type 'attributeReport', cluster 'genLevelCtrl', data '{"currentLevel":254}' from endpoint 1 with groupID 0
- serialport/stream _read reading { start: 413, toRead: 65123 } +3ms
- serialport/binding-abstract read +4ms
- serialport/bindings/unixRead Starting read +19ms
- serialport/bindings/unixWrite write returned: wrote 20 bytes +4ms
- serialport/bindings/unixWrite Finished writing 20 bytes +0ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +3ms
- serialport/bindings/poller Polling for "readable" +23ms
- serialport/bindings/poller received "readable" +9ms
- serialport/binding-abstract read +12ms
- serialport/bindings/unixRead Starting read +10ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +13ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,1,0,100] +19ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,1,0,100] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 1 - [] - 100 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - dataRequest - {"status":0} +4s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 419, toRead: 65117 } +4ms
- serialport/binding-abstract read +8ms
- serialport/bindings/unixRead Starting read +7ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +10ms
- serialport/bindings/poller received "readable" +595ms
- serialport/binding-abstract read +598ms
- serialport/bindings/unixRead Starting read +597ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 8 } +601ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,68,128,205,1,2,9] +603ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,68,128,205,1,2,9] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 4 - 128 - [�] - 9 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - dataConfirm - {"status":205,"endpoint":1,"transid":2} +640ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- zigbee-herdsman:controller:error Default response to 0x000d6ffffef31702 failed +0ms
- serialport/stream _read reading { start: 427, toRead: 65109 } +8ms
- serialport/binding-abstract read +11ms
- serialport/bindings/unixRead Starting read +11ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +14ms
- serialport/bindings/poller received "readable" +15s
- serialport/binding-abstract read +15s
- serialport/bindings/unixRead Starting read +15s
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 32 } +15s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,8,0,239,122,1,1,0,0,0,35,209,13,0,0,7,8,13,10,0,0,32,254,239,122,29,226] +15s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,8,0,239,122,1,1,0,0,0,35,209,13,0,0,7,8,13,10,0,0,32,254,239,122,29,226] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser ��z] - 226 +1ms2 - 4 - 129 - �z#�
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":8,"srcaddr":31471,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":0,"securityuse":0,"timestamp":905507,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[8,13,10,0,0,32,254]}} +15s
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false},"transactionSequenceNumber":13,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":32,"attrData":254}],"Cluster":{"ID":8,"attributes":{"currentLevel":{"ID":0,"type":32,"name":"currentLevel"},"remainingTime":{"ID":1,"type":33,"name":"remainingTime"},"onOffTransitionTime":{"ID":16,"type":33,"name":"onOffTransitionTime"},"onLevel":{"ID":17,"type":32,"name":"onLevel"},"onTransitionTime":{"ID":18,"type":33,"name":"onTransitionTime"},"offTransitionTime":{"ID":19,"type":33,"name":"offTransitionTime"},"defaultMoveRate":{"ID":20,"type":33,"name":"defaultMoveRate"}},"name":"genLevelCtrl","commands":{"moveToLevel":{"ID":0,"parameters":[{"name":"level","type":32},{"name":"transtime","type":33}],"name":"moveToLevel"},"move":{"ID":1,"parameters":[{"name":"movemode","type":32},{"name":"rate","type":32}],"name":"move"},"step":{"ID":2,"parameters":[{"name":"stepmode","type":32},{"name":"stepsize","type":32},{"name":"transtime","type":33}],"name":"step"},"stop":{"ID":3,"parameters":[],"name":"stop"},"moveToLevelWithOnOff":{"ID":4,"parameters":[{"name":"level","type":32},{"name":"transtime","type":33}],"name":"moveToLevelWithOnOff"},"moveWithOnOff":{"ID":5,"parameters":[{"name":"movemode","type":32},{"name":"rate","type":32}],"name":"moveWithOnOff"},"stepWithOnOff":{"ID":6,"parameters":[{"name":"stepmode","type":32},{"name":"stepsize","type":32},{"name":"transtime","type":33}],"name":"stepWithOnOff"},"stopWithOnOff":{"ID":7,"parameters":[],"name":"stopWithOnOff"}},"commandsResponse":{}}},"networkAddress":31471,"endpoint":1,"linkquality":0,"groupID":0}' +16s
- zigbee2mqtt:debug 2019-12-08T15:38:52: Received Zigbee message from 'Bulb_FF_LivingRoom1', type 'attributeReport', cluster 'genLevelCtrl', data '{"currentLevel":254}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:52: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:52: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom1', payload '{"state":"OFF","linkquality":0,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom1","ieeeAddr":"0xd0cf5efffeda2156","networkAddress":31471,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - dataRequest - {"dstaddr":31471,"destendpoint":1,"srcendpoint":1,"clusterid":8,"transid":3,"options":0,"radius":30,"len":5,"data":{"type":"Buffer","data":[24,13,11,10,0]}} +16s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,15,36,1,239,122,1,1,8,0,3,0,30,5,24,13,11,10,0,187] +16s
- serialport/stream _write 20 bytes of data +26ms
- serialport/binding-abstract write 20 bytes +28ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +23ms
- serialport/bindings/unixWrite Starting write 20 bytes offset 0 bytesToWrite 20 +16s
- winston:file logged 15712 debug 2019-12-08T15:38:52: Received Zigbee message from 'Bulb_FF_LivingRoom1', type 'attributeReport', cluster 'genLevelCtrl', data '{"currentLevel":254}' from endpoint 1 with groupID 0
- winston:file logged 15835 info 2019-12-08T15:38:52: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 16317 info 2019-12-08T15:38:52: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom1', payload '{"state":"OFF","linkquality":0,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom1","ieeeAddr":"0xd0cf5efffeda2156","networkAddress":31471,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- serialport/stream _read reading { start: 459, toRead: 65077 } +5ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +34ms
- serialport/bindings/unixWrite write returned: wrote 20 bytes +7ms
- serialport/bindings/unixWrite Finished writing 20 bytes +0ms
- serialport/stream binding.write write finished +4ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +39ms
- serialport/bindings/poller received "readable" +5ms
- serialport/binding-abstract read +9ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +8ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,1,0,100] +17ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,1,0,100] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 1 - [] - 100 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - dataRequest - {"status":0} +16s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 465, toRead: 65071 } +4ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +8ms
- serialport/bindings/poller received "readable" +343ms
- serialport/binding-abstract read +346ms
- serialport/bindings/unixRead Starting read +344ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +348ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,68,128,0,1,3,197] +349ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,68,128,0,1,3,197] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 4 - 128 - [] - 197 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - dataConfirm - {"status":0,"endpoint":1,"transid":3} +393ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 473, toRead: 65063 } +4ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +0ms
- serialport/bindings/poller Polling for "readable" +9ms
- serialport/bindings/poller received "readable" +4s
- serialport/binding-abstract read +4s
- serialport/bindings/unixRead Starting read +4s
- serialport/bindings/unixRead Finished read { bytesRead: 17,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 17 } +4s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +4s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +1ms
- �] - 28 +0msdsman:adapter:zStack:unpi:parser --> parsed 12 - 2 - 5 - 202 - [�-�̼��o
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - tcDeviceInd - {"nwkaddr":11686,"extaddr":"0x000d6ffffebccc86","parentaddr":36881} +4s
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' joined +4s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +5ms
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' accepted by handler +2ms
- zigbee-herdsman:controller:log Interview '0x000d6ffffebccc86' start +1ms
- zigbee2mqtt:info 2019-12-08T15:38:56: Starting interview of 'IKEA_Test_Skt'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:38:56: MQTT publish: topic 'zigbee2mqtt/bridge/log', payload '{"type":"pairing","message":"interview_started","meta":{"friendly_name":"IKEA_Test_Skt"}}'
- winston:file written true false
- zigbee-herdsman:controller:device Interview - start device '0x000d6ffffebccc86' +0ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> ZDO - nodeDescReq - {"dstaddr":11686,"nwkaddrofinterest":11686} +4s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,4,37,2,166,45,166,45,35] +4s
- serialport/stream _write 9 bytes of data +27ms
- serialport/binding-abstract write 9 bytes +28ms
- serialport/bindings/unixWrite Starting write 9 bytes offset 0 bytesToWrite 9 +4s
- serialport/stream _read reading { start: 490, toRead: 65046 } +2ms
- serialport/binding-abstract read +3ms
- winston:file logged 16382 info 2019-12-08T15:38:56: Starting interview of 'IKEA_Test_Skt'
- winston:file logged 16555 info 2019-12-08T15:38:56: MQTT publish: topic 'zigbee2mqtt/bridge/log', payload '{"type":"pairing","message":"interview_started","meta":{"friendly_name":"IKEA_Test_Skt"}}'
- serialport/bindings/unixRead Starting read +33ms
- serialport/bindings/unixWrite write returned: wrote 9 bytes +6ms
- serialport/bindings/unixWrite Finished writing 9 bytes +0ms
- serialport/stream binding.write write finished +5ms
- serialport/bindings/unixRead Finished read { bytesRead: 17,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +2ms
- serialport/stream binding.read finished { bytesRead: 17 } +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +29ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +1ms
- �] - 28 +0msdsman:adapter:zStack:unpi:parser --> parsed 12 - 2 - 5 - 202 - [�-�̼��o
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - tcDeviceInd - {"nwkaddr":11686,"extaddr":"0x000d6ffffebccc86","parentaddr":36881} +35ms
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' joined +29ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' accepted by handler +1ms
- zigbee-herdsman:controller:log Not interviewing '0x000d6ffffebccc86', completed 'undefined', in progress 'true' +0ms
- serialport/stream _read reading { start: 507, toRead: 65029 } +5ms
- serialport/binding-abstract read +11ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +2ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,101,2,0,102] +4ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,101,2,0,102] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 5 - 2 - [] - 102 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- ZDO - nodeDescReq - {"status":0} +4s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 513, toRead: 65023 } +4ms
- serialport/binding-abstract read +5ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +0ms
- serialport/bindings/poller Polling for "readable" +49ms
- serialport/bindings/poller received "readable" +3s
- serialport/binding-abstract read +3s
- serialport/bindings/unixRead Starting read +3s
- serialport/bindings/unixRead Finished read { bytesRead: 17,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 17 } +3s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +3s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +1ms
- �] - 28 +0msdsman:adapter:zStack:unpi:parser --> parsed 12 - 2 - 5 - 202 - [�-�̼��o
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - tcDeviceInd - {"nwkaddr":11686,"extaddr":"0x000d6ffffebccc86","parentaddr":36881} +3s
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' joined +3s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' accepted by handler +0ms
- zigbee-herdsman:controller:log Not interviewing '0x000d6ffffebccc86', completed 'undefined', in progress 'true' +1ms
- serialport/stream _read reading { start: 530, toRead: 65006 } +5ms
- serialport/binding-abstract read +7ms
- serialport/bindings/unixRead Starting read +7ms
- serialport/bindings/unixRead Finished read { bytesRead: 17,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 17 } +2ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +5ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,12,69,202,166,45,134,204,188,254,255,111,13,0,17,144,28] +0ms
- �] - 28 +0msdsman:adapter:zStack:unpi:parser --> parsed 12 - 2 - 5 - 202 - [�-�̼��o
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- ZDO - tcDeviceInd - {"nwkaddr":11686,"extaddr":"0x000d6ffffebccc86","parentaddr":36881} +7ms
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' joined +6ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- zigbee-herdsman:controller:log Device '0x000d6ffffebccc86' accepted by handler +0ms
- zigbee-herdsman:controller:log Not interviewing '0x000d6ffffebccc86', completed 'undefined', in progress 'true' +1ms
- serialport/stream _read reading { start: 547, toRead: 64989 } +4ms
- serialport/binding-abstract read +7ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +16ms
- serialport/bindings/poller received "readable" +1s
- serialport/binding-abstract read +1s
- serialport/bindings/unixRead Starting read +1s
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 32 } +1s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,6,0,162,246,1,1,0,28,0,2,58,14,0,0,7,8,110,10,0,0,16,0,162,246,29,148] +1s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,6,0,162,246,1,1,0,28,0,2,58,14,0,0,7,8,110,10,0,0,16,0,162,246,29,148] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 27 - 2 - 4 - 129 - [��n
- zigbee-herdsman:adapter:zStack:unpi:parser ��] - 148 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":6,"srcaddr":63138,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":28,"securityuse":0,"timestamp":932354,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[8,110,10,0,0,16,0]}} +1s
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false},"transactionSequenceNumber":110,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":16,"attrData":0}],"Cluster":{"ID":6,"attributes":{"onOff":{"ID":0,"type":16,"name":"onOff"},"globalSceneCtrl":{"ID":16384,"type":16,"name":"globalSceneCtrl"},"onTime":{"ID":16385,"type":33,"name":"onTime"},"offWaitTime":{"ID":16386,"type":33,"name":"offWaitTime"}},"name":"genOnOff","commands":{"off":{"ID":0,"parameters":[],"name":"off"},"on":{"ID":1,"parameters":[],"name":"on"},"toggle":{"ID":2,"parameters":[],"name":"toggle"},"offWithEffect":{"ID":64,"parameters":[{"name":"effectid","type":32},{"name":"effectvariant","type":32}],"name":"offWithEffect"},"onWithRecallGlobalScene":{"ID":65,"parameters":[],"name":"onWithRecallGlobalScene"},"onWithTimedOff":{"ID":66,"parameters":[{"name":"ctrlbits","type":32},{"name":"ontime","type":33},{"name":"offwaittime","type":33}],"name":"onWithTimedOff"}},"commandsResponse":{}}},"networkAddress":63138,"endpoint":1,"linkquality":28,"groupID":0}' +1s
- zigbee2mqtt:debug 2019-12-08T15:39:01: Received Zigbee message from 'Bulb_FF_LivingRoom2', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom2', payload '{"state":"OFF","linkquality":28,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom2","ieeeAddr":"0xd0cf5efffed833d7","networkAddress":63138,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - dataRequest - {"dstaddr":63138,"destendpoint":1,"srcendpoint":1,"clusterid":6,"transid":4,"options":0,"radius":30,"len":5,"data":{"type":"Buffer","data":[24,110,11,10,0]}} +4s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,15,36,1,162,246,1,1,6,0,4,0,30,5,24,110,11,10,0,16] +4s
- serialport/stream _write 20 bytes of data +18ms
- serialport/binding-abstract write 20 bytes +20ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +17ms
- serialport/bindings/unixWrite Starting write 20 bytes offset 0 bytesToWrite 20 +4s
- winston:file logged 16728 debug 2019-12-08T15:39:01: Received Zigbee message from 'Bulb_FF_LivingRoom2', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file logged 16851 info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 17334 info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom2', payload '{"state":"OFF","linkquality":28,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom2","ieeeAddr":"0xd0cf5efffed833d7","networkAddress":63138,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- serialport/stream _read reading { start: 579, toRead: 64957 } +5ms
- serialport/binding-abstract read +5ms
- serialport/bindings/unixRead Starting read +25ms
- serialport/bindings/unixWrite write returned: wrote 20 bytes +6ms
- serialport/bindings/unixWrite Finished writing 20 bytes +0ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +29ms
- serialport/bindings/poller received "readable" +12ms
- serialport/binding-abstract read +16ms
- serialport/bindings/unixRead Starting read +13ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +15ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,1,0,100] +23ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,1,0,100] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 1 - [] - 100 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - dataRequest - {"status":0} +4s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 585, toRead: 64951 } +4ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +8ms
- serialport/bindings/poller received "readable" +140ms
- serialport/binding-abstract read +141ms
- serialport/bindings/unixRead Starting read +141ms
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 32 } +144ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,6,0,63,17,1,1,0,39,0,156,59,14,0,0,7,8,110,10,0,0,16,0,63,17,29,48] +146ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,6,0,63,17,1,1,0,39,0,156,59,14,0,0,7,8,110,10,0,0,16,0,63,17,29,48] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 27 - 2 - 4 - 129 - [?'�n
- zigbee-herdsman:adapter:zStack:unpi:parser ?] - 48 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":6,"srcaddr":4415,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":39,"securityuse":0,"timestamp":932764,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[8,110,10,0,0,16,0]}} +189ms
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false},"transactionSequenceNumber":110,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":16,"attrData":0}],"Cluster":{"ID":6,"attributes":{"onOff":{"ID":0,"type":16,"name":"onOff"},"globalSceneCtrl":{"ID":16384,"type":16,"name":"globalSceneCtrl"},"onTime":{"ID":16385,"type":33,"name":"onTime"},"offWaitTime":{"ID":16386,"type":33,"name":"offWaitTime"}},"name":"genOnOff","commands":{"off":{"ID":0,"parameters":[],"name":"off"},"on":{"ID":1,"parameters":[],"name":"on"},"toggle":{"ID":2,"parameters":[],"name":"toggle"},"offWithEffect":{"ID":64,"parameters":[{"name":"effectid","type":32},{"name":"effectvariant","type":32}],"name":"offWithEffect"},"onWithRecallGlobalScene":{"ID":65,"parameters":[],"name":"onWithRecallGlobalScene"},"onWithTimedOff":{"ID":66,"parameters":[{"name":"ctrlbits","type":32},{"name":"ontime","type":33},{"name":"offwaittime","type":33}],"name":"onWithTimedOff"}},"commandsResponse":{}}},"networkAddress":4415,"endpoint":1,"linkquality":39,"groupID":0}' +189ms
- zigbee2mqtt:debug 2019-12-08T15:39:01: Received Zigbee message from 'Bulb_FF_LivingRoom3', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom3', payload '{"state":"OFF","linkquality":39,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom3","ieeeAddr":"0x90fd9ffffe2a1e72","networkAddress":4415,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +13ms
- winston:file logged 17507 debug 2019-12-08T15:39:01: Received Zigbee message from 'Bulb_FF_LivingRoom3', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file logged 17630 info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 18112 info 2019-12-08T15:39:01: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom3', payload '{"state":"OFF","linkquality":39,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom3","ieeeAddr":"0x90fd9ffffe2a1e72","networkAddress":4415,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- serialport/stream _read reading { start: 617, toRead: 64919 } +19ms
- serialport/binding-abstract read +22ms
- serialport/bindings/unixRead Starting read +20ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +24ms
- serialport/bindings/poller received "readable" +168ms
- serialport/binding-abstract read +171ms
- serialport/bindings/unixRead Starting read +170ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +174ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,68,128,0,1,4,194] +179ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,68,128,0,1,4,194] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 4 - 128 - [] - 194 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - dataConfirm - {"status":0,"endpoint":1,"transid":4} +192ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +2ms
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - dataRequest - {"dstaddr":4415,"destendpoint":1,"srcendpoint":1,"clusterid":6,"transid":5,"options":0,"radius":30,"len":5,"data":{"type":"Buffer","data":[24,110,11,10,0]}} +369ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,15,36,1,63,17,1,1,6,0,5,0,30,5,24,110,11,10,0,107] +369ms
- serialport/stream _write 20 bytes of data +6ms
- serialport/binding-abstract write 20 bytes +8ms
- serialport/bindings/unixWrite Starting write 20 bytes offset 0 bytesToWrite 20 +362ms
- serialport/stream _read reading { start: 625, toRead: 64911 } +1ms
- serialport/binding-abstract read +2ms
- serialport/bindings/unixRead Starting read +10ms
- serialport/bindings/unixWrite write returned: wrote 20 bytes +3ms
- serialport/bindings/unixWrite Finished writing 20 bytes +1ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +14ms
- serialport/bindings/poller received "readable" +4ms
- serialport/binding-abstract read +8ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +7ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,1,0,100] +15ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,1,0,100] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 1 - [] - 100 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - dataRequest - {"status":0} +359ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 631, toRead: 64905 } +5ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +9ms
- serialport/bindings/poller received "readable" +6ms
- serialport/binding-abstract read +9ms
- serialport/bindings/unixRead Starting read +7ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +10ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,68,128,0,1,5,195] +12ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,68,128,0,1,5,195] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 4 - 128 - [] - 195 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - dataConfirm - {"status":0,"endpoint":1,"transid":5} +32ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 639, toRead: 64897 } +4ms
- PuTTY serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +8ms
- serialport/bindings/poller received "readable" +1s
- serialport/binding-abstract read +1s
- serialport/bindings/unixRead Starting read +1s
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 32 } +1s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,6,0,17,144,1,1,0,31,0,168,78,14,0,0,7,8,71,10,0,0,16,0,180,167,28,243] +1s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,6,0,17,144,1,1,0,31,0,168,78,14,0,0,7,8,71,10,0,0,16,0,180,167,28,243] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 27 - 2 - 4 - 129 - [��G
- zigbee-herdsman:adapter:zStack:unpi:parser ��] - 243 +1ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":6,"srcaddr":36881,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":31,"securityuse":0,"timestamp":937640,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[8,71,10,0,0,16,0]}} +1s
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false},"transactionSequenceNumber":71,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":16,"attrData":0}],"Cluster":{"ID":6,"attributes":{"onOff":{"ID":0,"type":16,"name":"onOff"},"globalSceneCtrl":{"ID":16384,"type":16,"name":"globalSceneCtrl"},"onTime":{"ID":16385,"type":33,"name":"onTime"},"offWaitTime":{"ID":16386,"type":33,"name":"offWaitTime"}},"name":"genOnOff","commands":{"off":{"ID":0,"parameters":[],"name":"off"},"on":{"ID":1,"parameters":[],"name":"on"},"toggle":{"ID":2,"parameters":[],"name":"toggle"},"offWithEffect":{"ID":64,"parameters":[{"name":"effectid","type":32},{"name":"effectvariant","type":32}],"name":"offWithEffect"},"onWithRecallGlobalScene":{"ID":65,"parameters":[],"name":"onWithRecallGlobalScene"},"onWithTimedOff":{"ID":66,"parameters":[{"name":"ctrlbits","type":32},{"name":"ontime","type":33},{"name":"offwaittime","type":33}],"name":"onWithTimedOff"}},"commandsResponse":{}}},"networkAddress":36881,"endpoint":1,"linkquality":31,"groupID":0}' +1s
- zigbee2mqtt:debug 2019-12-08T15:39:02: Received Zigbee message from 'Bulb_FF_LivingRoom4', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:02: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:02: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom4', payload '{"state":"OFF","linkquality":31,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom4","ieeeAddr":"0x90fd9ffffe152a4e","networkAddress":36881,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - dataRequest - {"dstaddr":36881,"destendpoint":1,"srcendpoint":1,"clusterid":6,"transid":6,"options":0,"radius":30,"len":5,"data":{"type":"Buffer","data":[24,71,11,10,0]}} +1s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,15,36,1,17,144,1,1,6,0,6,0,30,5,24,71,11,10,0,238] +1s
- serialport/stream _write 20 bytes of data +17ms
- serialport/binding-abstract write 20 bytes +19ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +16ms
- serialport/bindings/unixWrite Starting write 20 bytes offset 0 bytesToWrite 20 +1s
- winston:file logged 18285 debug 2019-12-08T15:39:02: Received Zigbee message from 'Bulb_FF_LivingRoom4', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file logged 18408 info 2019-12-08T15:39:02: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 18891 info 2019-12-08T15:39:02: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom4', payload '{"state":"OFF","linkquality":31,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom4","ieeeAddr":"0x90fd9ffffe152a4e","networkAddress":36881,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- serialport/stream _read reading { start: 671, toRead: 64865 } +8ms
- serialport/binding-abstract read +8ms
- serialport/bindings/unixRead Starting read +28ms
- serialport/bindings/unixWrite write returned: wrote 20 bytes +9ms
- serialport/bindings/unixWrite Finished writing 20 bytes +0ms
- serialport/stream binding.write write finished +4ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +32ms
- serialport/bindings/poller received "readable" +1ms
- serialport/binding-abstract read +5ms
- serialport/bindings/unixRead Starting read +3ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +4ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,1,0,100] +16ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,1,0,100] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 1 - [] - 100 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - dataRequest - {"status":0} +1s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 677, toRead: 64859 } +4ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +2ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,68,128,0,1,6,192] +4ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,68,128,0,1,6,192] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 4 - 128 - [] - 192 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - dataConfirm - {"status":0,"endpoint":1,"transid":6} +38ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 685, toRead: 64851 } +3ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +5ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +13ms
- serialport/bindings/poller received "readable" +443ms
- serialport/binding-abstract read +445ms
- serialport/bindings/unixRead Starting read +444ms
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 32 } +447ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,6,0,239,122,1,1,0,31,0,159,84,14,0,0,7,8,14,10,0,0,16,0,180,167,28,131] +449ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,6,0,239,122,1,1,0,31,0,159,84,14,0,0,7,8,14,10,0,0,16,0,180,167,28,131] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 27 - 2 - 4 - 129 - [�z�T
- zigbee-herdsman:adapter:zStack:unpi:parser ��] - 131 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":6,"srcaddr":31471,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":31,"securityuse":0,"timestamp":939167,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[8,14,10,0,0,16,0]}} +454ms
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false},"transactionSequenceNumber":14,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":16,"attrData":0}],"Cluster":{"ID":6,"attributes":{"onOff":{"ID":0,"type":16,"name":"onOff"},"globalSceneCtrl":{"ID":16384,"type":16,"name":"globalSceneCtrl"},"onTime":{"ID":16385,"type":33,"name":"onTime"},"offWaitTime":{"ID":16386,"type":33,"name":"offWaitTime"}},"name":"genOnOff","commands":{"off":{"ID":0,"parameters":[],"name":"off"},"on":{"ID":1,"parameters":[],"name":"on"},"toggle":{"ID":2,"parameters":[],"name":"toggle"},"offWithEffect":{"ID":64,"parameters":[{"name":"effectid","type":32},{"name":"effectvariant","type":32}],"name":"offWithEffect"},"onWithRecallGlobalScene":{"ID":65,"parameters":[],"name":"onWithRecallGlobalScene"},"onWithTimedOff":{"ID":66,"parameters":[{"name":"ctrlbits","type":32},{"name":"ontime","type":33},{"name":"offwaittime","type":33}],"name":"onWithTimedOff"}},"commandsResponse":{}}},"networkAddress":31471,"endpoint":1,"linkquality":31,"groupID":0}' +493ms
- zigbee2mqtt:debug 2019-12-08T15:39:03: Received Zigbee message from 'Bulb_FF_LivingRoom1', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:03: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:03: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom1', payload '{"state":"OFF","linkquality":31,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom1","ieeeAddr":"0xd0cf5efffeda2156","networkAddress":31471,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- winston:file written true false
- zigbee-herdsman:adapter:zStack:znp:SREQ --> AF - dataRequest - {"dstaddr":31471,"destendpoint":1,"srcendpoint":1,"clusterid":6,"transid":7,"options":0,"radius":30,"len":5,"data":{"type":"Buffer","data":[24,14,11,10,0]}} +492ms
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,15,36,1,239,122,1,1,6,0,7,0,30,5,24,14,11,10,0,178] +493ms
- serialport/stream _write 20 bytes of data +21ms
- serialport/binding-abstract write 20 bytes +22ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +20ms
- serialport/bindings/unixWrite Starting write 20 bytes offset 0 bytesToWrite 20 +483ms
- winston:file logged 19064 debug 2019-12-08T15:39:03: Received Zigbee message from 'Bulb_FF_LivingRoom1', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0
- winston:file logged 19187 info 2019-12-08T15:39:03: MQTT publish: topic 'zigbee2mqtt/living_room_light', payload '{"state":"OFF","brightness":254}'
- winston:file logged 19670 info 2019-12-08T15:39:03: MQTT publish: topic 'zigbee2mqtt/Bulb_FF_LivingRoom1', payload '{"state":"OFF","linkquality":31,"brightness":254,"device":{"friendlyName":"Bulb_FF_LivingRoom1","ieeeAddr":"0xd0cf5efffeda2156","networkAddress":31471,"type":"Router","manufacturerID":4476,"manufacturerName":"IKEA of Sweden","powerSource":"Mains (single phase)","applicationVersion":17,"stackVersion":87,"zclVersion":1,"hardwareVersion":1,"dateCode":"20170302","softwareBuildID":"1.2.214"}}'
- serialport/stream _read reading { start: 717, toRead: 64819 } +5ms
- serialport/binding-abstract read +5ms
- serialport/bindings/unixRead Starting read +27ms
- serialport/bindings/unixWrite write returned: wrote 20 bytes +6ms
- serialport/bindings/unixWrite Finished writing 20 bytes +0ms
- serialport/stream binding.write write finished +2ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +2ms
- serialport/bindings/poller Polling for "readable" +31ms
- serialport/bindings/poller received "readable" +6ms
- serialport/binding-abstract read +9ms
- serialport/bindings/unixRead Starting read +7ms
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +9ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,100,1,0,100] +16ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,100,1,0,100] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 4 - 1 - [] - 100 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- AF - dataRequest - {"status":0} +493ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 723, toRead: 64813 } +4ms
- serialport/binding-abstract read +6ms
- serialport/bindings/unixRead Starting read +11ms
- serialport/bindings/unixRead Finished read { bytesRead: 8,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 8 } +8ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,3,68,128,0,1,7,193] +10ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,3,68,128,0,1,7,193] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 3 - 2 - 4 - 128 - [] - 193 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - dataConfirm - {"status":0,"endpoint":1,"transid":7} +46ms
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 731, toRead: 64805 } +4ms
- serialport/binding-abstract read +13ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +20ms
- zigbee-herdsman:controller:device Interview - first node descriptor request failed for '0x000d6ffffebccc86', retrying... +10s
- zigbee-herdsman:adapter:zStack:znp:SREQ --> ZDO - nodeDescReq - {"dstaddr":11686,"nwkaddrofinterest":11686} +3s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,4,37,2,166,45,166,45,35] +3s
- serialport/stream _write 9 bytes of data +3s
- serialport/binding-abstract write 9 bytes +3s
- serialport/bindings/unixWrite Starting write 9 bytes offset 0 bytesToWrite 9 +3s
- serialport/bindings/unixWrite write returned: wrote 9 bytes +1ms
- serialport/bindings/unixWrite Finished writing 9 bytes +1ms
- serialport/stream binding.write write finished +3ms
- serialport/bindings/poller received "readable" +3s
- serialport/binding-abstract read +15ms
- serialport/bindings/unixRead Starting read +3s
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 6 } +14ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,101,2,0,102] +3s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,101,2,0,102] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 5 - 2 - [] - 102 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- ZDO - nodeDescReq - {"status":0} +3s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +1ms
- serialport/stream _read reading { start: 737, toRead: 64799 } +3ms
- serialport/binding-abstract read +5ms
- serialport/bindings/unixRead Starting read +4ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +7ms
- serialport/bindings/poller received "readable" +7s
- serialport/binding-abstract read +7s
- serialport/bindings/unixRead Starting read +7s
- serialport/bindings/unixRead Finished read { bytesRead: 32,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +1ms
- serialport/stream binding.read finished { bytesRead: 32 } +7s
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,27,68,129,0,0,6,4,37,31,1,1,0,81,0,129,207,14,0,0,7,24,17,10,0,0,24,1,37,31,29,205] +7s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,27,68,129,0,0,6,4,37,31,1,1,0,81,0,129,207,14,0,0,7,24,17,10,0,0,24,1,37,31,29,205] +1ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 27 - 2 - 4 - 129 - [%Q��
- zigbee-herdsman:adapter:zStack:unpi:parser %] - 205 +0ms
- zigbee-herdsman:adapter:zStack:znp:AREQ <-- AF - incomingMsg - {"groupid":0,"clusterid":1030,"srcaddr":7973,"srcendpoint":1,"dstendpoint":1,"wasbroadcast":0,"linkquality":81,"securityuse":0,"timestamp":970625,"transseqnumber":0,"len":7,"data":{"type":"Buffer","data":[24,17,10,0,0,24,1]}} +10s
- zigbee-herdsman:controller:log Received 'zcl' data '{"frame":{"Header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true},"transactionSequenceNumber":17,"manufacturerCode":null,"commandIdentifier":10},"Payload":[{"attrId":0,"dataType":24,"attrData":1}],"Cluster":{"ID":1030,"attributes":{"occupancy":{"ID":0,"type":24,"name":"occupancy"},"occupancySensorType":{"ID":1,"type":48,"name":"occupancySensorType"},"pirOToUDelay":{"ID":16,"type":33,"name":"pirOToUDelay"},"pirUToODelay":{"ID":17,"type":33,"name":"pirUToODelay"},"pirUToOThreshold":{"ID":18,"type":32,"name":"pirUToOThreshold"},"ultrasonicOToUDelay":{"ID":32,"type":33,"name":"ultrasonicOToUDelay"},"ultrasonicUToODelay":{"ID":33,"type":33,"name":"ultrasonicUToODelay"},"ultrasonicUToOThreshold":{"ID":34,"type":32,"name":"ultrasonicUToOThreshold"}},"name":"msOccupancySensing","commands":{},"commandsResponse":{}}},"networkAddress":7973,"endpoint":1,"linkquality":81,"groupID":0}' +10s
- zigbee2mqtt:debug 2019-12-08T15:39:13: Received Zigbee message from 'PIR_FF_LivingRoom', type 'attributeReport', cluster 'msOccupancySensing', data '{"occupancy":1}' from endpoint 1 with groupID 0
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:13: MQTT publish: topic 'zigbee2mqtt/PIR_FF_LivingRoom', payload '{"occupancy":true,"linkquality":81,"battery":100,"voltage":3015,"device":{"friendlyName":"PIR_FF_LivingRoom","ieeeAddr":"0x00158d000155b510","networkAddress":7973,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- winston:file written true false
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +14ms
- winston:file logged 19855 debug 2019-12-08T15:39:13: Received Zigbee message from 'PIR_FF_LivingRoom', type 'attributeReport', cluster 'msOccupancySensing', data '{"occupancy":1}' from endpoint 1 with groupID 0
- winston:file logged 20201 info 2019-12-08T15:39:13: MQTT publish: topic 'zigbee2mqtt/PIR_FF_LivingRoom', payload '{"occupancy":true,"linkquality":81,"battery":100,"voltage":3015,"device":{"friendlyName":"PIR_FF_LivingRoom","ieeeAddr":"0x00158d000155b510","networkAddress":7973,"type":"EndDevice","manufacturerID":4151,"manufacturerName":"LUMI","powerSource":"Battery"}}'
- serialport/stream _read reading { start: 769, toRead: 64767 } +19ms
- serialport/binding-abstract read +22ms
- serialport/bindings/unixRead Starting read +21ms
- serialport/bindings/unixRead waiting for readable because of code: EAGAIN +1ms
- serialport/bindings/poller Polling for "readable" +25ms
- zigbee-herdsman:controller:device Interview - failed for device '0x000d6ffffebccc86' with error 'Error: AREQ - ZDO - nodeDescRsp after 10000ms
- zigbee-herdsman:controller:device at Timeout.object.timer.setTimeout [as _onTimeout] (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/dist/utils/waitress.js:44:24)
- zigbee-herdsman:controller:device at ontimeout (timers.js:436:11)
- zigbee-herdsman:controller:device at tryOnTimeout (timers.js:300:5)
- zigbee-herdsman:controller:device at listOnTimeout (timers.js:263:5)
- zigbee-herdsman:controller:device at Timer.processTimers (timers.js:223:10)' +10s
- zigbee-herdsman:controller:error Interview failed for '0x000d6ffffebccc86 with error 'Error: AREQ - ZDO - nodeDescRsp after 10000ms' +39s
- zigbee2mqtt:error 2019-12-08T15:39:16: Failed to interview 'IKEA_Test_Skt', device has not successfully been paired
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:16: MQTT publish: topic 'zigbee2mqtt/bridge/log', payload '{"type":"pairing","message":"interview_failed","meta":{"friendly_name":"IKEA_Test_Skt"}}'
- winston:file written true false
- winston:file logged 20305 error 2019-12-08T15:39:16: Failed to interview 'IKEA_Test_Skt', device has not successfully been paired
- winston:file logged 20477 info 2019-12-08T15:39:16: MQTT publish: topic 'zigbee2mqtt/bridge/log', payload '{"type":"pairing","message":"interview_failed","meta":{"friendly_name":"IKEA_Test_Skt"}}'
- ^Czigbee2mqtt:debug 2019-12-08T15:39:26: Saving state to file /opt/zigbee2mqtt/data/state.json
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:26: MQTT publish: topic 'zigbee2mqtt/bridge/state', payload 'offline'
- winston:file written true false
- zigbee2mqtt:info 2019-12-08T15:39:26: Disconnecting from MQTT server
- winston:file written true false
- zigbee-herdsman:controller:log Disable joining +13s
- zigbee-herdsman:adapter:zStack:znp:SREQ --> ZDO - mgmtPermitJoinReq - {"addrmode":15,"dstaddr":65532,"duration":0,"tcsignificance":0} +20s
- zigbee-herdsman:adapter:zStack:unpi:writer --> frame [254,5,37,54,15,252,255,0,0,26] +20s
- serialport/stream _write 10 bytes of data +13s
- serialport/binding-abstract write 10 bytes +13s
- serialport/bindings/unixWrite Starting write 10 bytes offset 0 bytesToWrite 10 +20s
- winston:file logged 20558 debug 2019-12-08T15:39:26: Saving state to file /opt/zigbee2mqtt/data/state.json
- winston:file logged 20651 info 2019-12-08T15:39:26: MQTT publish: topic 'zigbee2mqtt/bridge/state', payload 'offline'
- winston:file logged 20709 info 2019-12-08T15:39:26: Disconnecting from MQTT server
- serialport/bindings/unixWrite write returned: wrote 10 bytes +4ms
- serialport/bindings/unixWrite Finished writing 10 bytes +0ms
- serialport/stream binding.write write finished +5ms
- serialport/bindings/poller received "readable" +13s
- serialport/binding-abstract read +13ms
- serialport/bindings/unixRead Starting read +13s
- serialport/bindings/unixRead Finished read { bytesRead: 6,
- buffer:
- <Buffer fe 05 45 c4 b4 a7 01 5c c5 0f fe 05 45 c4 22 93 01 5c c5 ad fe 05 45 c4 22 93 01 5c c5 ad fe 03 45 c4 5c c5 00 1b fe 05 45 c4 c8 46 01 5c c5 92 fe 05 ... > } bytes +0ms
- serialport/stream binding.read finished { bytesRead: 6 } +10ms
- zigbee-herdsman:adapter:zStack:unpi:parser <-- [254,1,101,54,0,82] +13s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [254,1,101,54,0,82] +0ms
- zigbee-herdsman:adapter:zStack:unpi:parser --> parsed 1 - 3 - 5 - 54 - [] - 82 +1ms
- zigbee-herdsman:adapter:zStack:znp:SRSP <-- ZDO - mgmtPermitJoinReq - {"status":0} +20s
- zigbee-herdsman:adapter:zStack:unpi:parser --- parseNext [] +0ms
- serialport/stream #flush +3ms
- serialport/binding-abstract flush +5ms
- serialport/stream _read reading { start: 775, toRead: 64761 } +1ms
- serialport/binding-abstract read +1ms
- serialport/bindings/unixRead Starting read +6ms
- serialport/stream binding.flush finished +2ms
- serialport/stream #close +0ms
- serialport/binding-abstract close +2ms
- serialport/bindings/poller Stopping poller +10ms
- serialport/bindings/poller Destroying poller +0ms
- serialport/stream binding.read error Error: Port is not open
- at LinuxBinding.unixRead (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/node_modules/@serialport/bindings/lib/unix-read.js:31:15) +3ms
- serialport/stream disconnected aborted because already closed Error: Port is not open
- at LinuxBinding.unixRead (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/node_modules/@serialport/bindings/lib/unix-read.js:31:15) +1ms
- serialport/stream _read queueing _read for after open +1ms
- serialport/stream binding.close finished +2ms
- zigbee-herdsman:adapter:zStack:znp:log Serialport closed +59s
- zigbee2mqtt:info 2019-12-08T15:39:26: zigbee-herdsman stopped
- winston:file written true false