  1. VERTIV-V5-MIB DEFINITIONS ::= BEGIN
  2.  
  3. IMPORTS
  4.  
  5. DisplayString, TruthValue, MacAddress FROM SNMPv2-TC
  6. SnmpAdminString FROM SNMP-FRAMEWORK-MIB
  7. MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32,
  8. Gauge32, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI
  9. sysName FROM SNMPv2-MIB;
  10.  
  11. vertiv MODULE-IDENTITY
  12. LAST-UPDATED "202001070000Z"
  13. ORGANIZATION "Vertiv"
  14. CONTACT-INFO "support@geistglobal.com"
  15. DESCRIPTION
  16. "The MIB for Vertiv products"
  17.  
  18. REVISION "202001070000Z"
  19. DESCRIPTION
  20. "Updates for VRC spec change"
  21.  
  22. REVISION "201909300000Z"
  23. DESCRIPTION
  24. "Added hostname, alarm/warning count, and manufacturer to deviceInfo"
  25.  
  26. REVISION "201909120000Z"
  27. DESCRIPTION
  28. "Added SN-2D door switch sensor"
  29.  
  30. REVISION "201908300000Z"
  31. DESCRIPTION
  32. "Removed current min, max, and peak fields from pdu phase, line,
  33. breaker, and outlet tables
  34. Removed voltage min, max, and peak fields from pdu phase, line,
  35. breaker, and outlet tables
  36. Removed minmax reset value from pduOutletMeterReset
  37. Added balance field to pdu phase table"
  38.  
  39. REVISION "201906060000Z"
  40. DESCRIPTION
  41. "Updated pduOutletSwitchControl description"
  42.  
  43. REVISION "201905070000Z"
  44. DESCRIPTION
  45. "Changed productMacAddress type to MacAddress"
  46.  
  47. REVISION "201904300000Z"
  48. DESCRIPTION
  49. "Added remote humidity-only sensor"
  50.  
  51. REVISION "201903070000Z"
  52. DESCRIPTION
  53. "Added VRC support"
  54.  
  55. REVISION "201801190000Z"
  56. DESCRIPTION
  57. "Modified pduOutletSwitchTable to support outlet actions with delays"
  58.  
  59. REVISION "201709190000Z"
  60. DESCRIPTION
  61. "Changed SYNTAX of objects, with a UTF-8 encoded string value, to
  62. SnmpAdminString"
  63.  
  64. REVISION "201708100000Z"
  65. DESCRIPTION
  66. "Added pduBreakerCurrentPeak, pduLineCurrentPeak,
  67. pduOutletMeterCurrentPeak, pduPhaseVoltagePeak, and
  68. pduPhaseCurrentPeak
  69. Updated object descriptions, indicating which fields are not supported
  70. on all platforms"
  71.  
  72. REVISION "201705100000Z"
  73. DESCRIPTION
  74. "Added trapObj group with trap payload objects
  75. Added additional payload objects to trap definitions"
  76.  
  77. REVISION "201704050000Z"
  78. DESCRIPTION
  79. "Added productPlatform to deviceInfo group
  80. Added product identity entries"
  81.  
  82. REVISION "201606300000Z"
  83. DESCRIPTION
  84. "Raven version"
  85.  
  86. REVISION "201209110000Z"
  87. DESCRIPTION
  88. "Original version"
  89. ::= { enterprises 21239 }
  90.  
  91. v5 OBJECT IDENTIFIER ::= { vertiv 5 }
  92.  
  93. imd OBJECT IDENTIFIER ::= { v5 2 }
  94.  
  95. --###########################################################################################--
  96. --deviceInfo--
  97. --###########################################################################################--
  98.  
  99. deviceInfo OBJECT IDENTIFIER ::= { imd 1 }
  100.  
  101. productTitle OBJECT-TYPE
  102. SYNTAX SnmpAdminString
  103. MAX-ACCESS read-only
  104. STATUS current
  105. DESCRIPTION
  106. "Product name"
  107. ::= { deviceInfo 1 }
  108.  
  109. productVersion OBJECT-TYPE
  110. SYNTAX SnmpAdminString
  111. MAX-ACCESS read-only
  112. STATUS current
  113. DESCRIPTION
  114. "Product version"
  115. ::= { deviceInfo 2 }
  116.  
  117. productFriendlyName OBJECT-TYPE
  118. SYNTAX SnmpAdminString
  119. MAX-ACCESS read-only
  120. STATUS current
  121. DESCRIPTION
  122. "User-assigned name"
  123. ::= { deviceInfo 3 }
  124.  
  125. productMacAddress OBJECT-TYPE
  126. SYNTAX MacAddress
  127. MAX-ACCESS read-only
  128. STATUS current
  129. DESCRIPTION
  130. "Product's unique MAC address"
  131. ::= { deviceInfo 4 }
  132.  
  133. deviceCount OBJECT-TYPE
  134. SYNTAX Integer32(0..16)
  135. MAX-ACCESS read-only
  136. STATUS current
  137. DESCRIPTION
  138. "Total number of devices on unit"
  139. ::= { deviceInfo 6 }
  140.  
  141. temperatureUnits OBJECT-TYPE
  142. SYNTAX INTEGER {
  143. fahrenheit(0),
  144. celsius(1)
  145. }
  146. MAX-ACCESS read-write
  147. STATUS current
  148. DESCRIPTION
  149. "Current units for temperature/dewpoint values:
  150. 0 = Degrees Fahrenheit
  151. 1 = Degrees Celsius"
  152. ::= { deviceInfo 7 }
  153.  
  154. productModelNumber OBJECT-TYPE
  155. SYNTAX SnmpAdminString
  156. MAX-ACCESS read-only
  157. STATUS current
  158. DESCRIPTION
  159. "Product model number (factory-assigned)"
  160. ::= { deviceInfo 8 }
  161.  
  162. productPartNumber OBJECT-TYPE
  163. SYNTAX SnmpAdminString
  164. MAX-ACCESS read-only
  165. STATUS current
  166. DESCRIPTION
  167. "Product part number (factory-assigned)"
  168. ::= { deviceInfo 9 }
  169.  
  170. productSerialNumber OBJECT-TYPE
  171. SYNTAX SnmpAdminString
  172. MAX-ACCESS read-only
  173. STATUS current
  174. DESCRIPTION
  175. "Product serial number (factory-assigned)"
  176. ::= { deviceInfo 10 }
  177.  
  178. productPlatform OBJECT-TYPE
  179. SYNTAX SnmpAdminString
  180. MAX-ACCESS read-only
  181. STATUS current
  182. DESCRIPTION
  183. "Product platform"
  184. ::= { deviceInfo 11 }
  185.  
  186. productHostname OBJECT-TYPE
  187. SYNTAX SnmpAdminString
  188. MAX-ACCESS read-only
  189. STATUS current
  190. DESCRIPTION
  191. "Product hostname"
  192. ::= { deviceInfo 12 }
  193.  
  194. productAlarmCount OBJECT-TYPE
  195. SYNTAX Integer32
  196. MAX-ACCESS read-only
  197. STATUS current
  198. DESCRIPTION
  199. "Number of alarms currently tripped"
  200. ::= { deviceInfo 13 }
  201.  
  202. productWarnCount OBJECT-TYPE
  203. SYNTAX Integer32
  204. MAX-ACCESS read-only
  205. STATUS current
  206. DESCRIPTION
  207. "Number of warnings currently tripped"
  208. ::= { deviceInfo 14 }
  209.  
  210. productManufacturer OBJECT-TYPE
  211. SYNTAX SnmpAdminString
  212. MAX-ACCESS read-only
  213. STATUS current
  214. DESCRIPTION
  215. "Product manufacturer"
  216. ::= { deviceInfo 15 }
  217.  
  218. --###########################################################################################--
  219. --pdu--
  220. --###########################################################################################--
  221.  
  222. pdu OBJECT IDENTIFIER ::= { imd 3 }
  223.  
  224. --###########################################################################################--
  225. --pduMainTable--
  226. --###########################################################################################--
  227.  
  228. pduMainTable OBJECT-TYPE
  229. SYNTAX SEQUENCE OF PduMainEntry
  230. MAX-ACCESS not-accessible
  231. STATUS current
  232. DESCRIPTION
  233. "PDU general information"
  234. ::= { pdu 1 }
  235.  
  236. pduMainEntry OBJECT-TYPE
  237. SYNTAX PduMainEntry
  238. MAX-ACCESS not-accessible
  239. STATUS current
  240. DESCRIPTION
  241. "Entry in the pduMainTable table: each entry contains an index
  242. and other sensor details"
  243. INDEX { pduMainIndex }
  244. ::= { pduMainTable 1 }
  245.  
  246. PduMainEntry ::= SEQUENCE {
  247. pduMainIndex Integer32,
  248. pduMainSerial DisplayString,
  249. pduMainName SnmpAdminString,
  250. pduMainLabel SnmpAdminString,
  251. pduMainAvail Gauge32,
  252. pduMeterType INTEGER,
  253. pduTotalName SnmpAdminString,
  254. pduTotalLabel SnmpAdminString,
  255. pduTotalRealPower Gauge32,
  256. pduTotalApparentPower Gauge32,
  257. pduTotalPowerFactor Gauge32,
  258. pduTotalEnergy Gauge32
  259. }
  260.  
  261. pduMainIndex OBJECT-TYPE
  262. SYNTAX Integer32(1..100)
  263. MAX-ACCESS not-accessible
  264. STATUS current
  265. DESCRIPTION
  266. "Table entry index value"
  267. ::= { pduMainEntry 1 }
  268.  
  269. pduMainSerial OBJECT-TYPE
  270. SYNTAX DisplayString
  271. MAX-ACCESS read-only
  272. STATUS current
  273. DESCRIPTION
  274. "Serial number"
  275. ::= { pduMainEntry 2 }
  276.  
  277. pduMainName OBJECT-TYPE
  278. SYNTAX SnmpAdminString(SIZE (1..25))
  279. MAX-ACCESS read-only
  280. STATUS current
  281. DESCRIPTION
  282. "PDU name (factory-assigned)"
  283. ::= { pduMainEntry 3 }
  284.  
  285. pduMainLabel OBJECT-TYPE
  286. SYNTAX SnmpAdminString(SIZE (0..25))
  287. MAX-ACCESS read-write
  288. STATUS current
  289. DESCRIPTION
  290. "PDU label (user-defined)"
  291. ::= { pduMainEntry 4 }
  292.  
  293. pduMainAvail OBJECT-TYPE
  294. SYNTAX Gauge32
  295. MAX-ACCESS read-only
  296. STATUS current
  297. DESCRIPTION
  298. "Device availability:
  299. 0 = Unavailable
  300. 1 = Available
  301. 2 = Partially Unavailable"
  302. ::= { pduMainEntry 5 }
  303.  
  304. pduMeterType OBJECT-TYPE
  305. SYNTAX INTEGER {
  306. wye(0),
  307. delta(1)
  308. }
  309. MAX-ACCESS read-only
  310. STATUS current
  311. DESCRIPTION
  312. "Current meter type:
  313. 0 = Wye
  314. 1 = Delta"
  315. ::= { pduMainEntry 6 }
  316.  
  317. pduTotalName OBJECT-TYPE
  318. SYNTAX SnmpAdminString(SIZE (1..25))
  319. MAX-ACCESS read-only
  320. STATUS current
  321. DESCRIPTION
  322. "Total name (factory-assigned)"
  323. ::= { pduMainEntry 7 }
  324.  
  325. pduTotalLabel OBJECT-TYPE
  326. SYNTAX SnmpAdminString(SIZE (0..25))
  327. MAX-ACCESS read-write
  328. STATUS current
  329. DESCRIPTION
  330. "Total label (user-defined)"
  331. ::= { pduMainEntry 8 }
  332.  
  333. pduTotalRealPower OBJECT-TYPE
  334. SYNTAX Gauge32(0..9999)
  335. UNITS "watts"
  336. MAX-ACCESS read-only
  337. STATUS current
  338. DESCRIPTION
  339. "PDU total real power"
  340. ::= { pduMainEntry 9 }
  341.  
  342. pduTotalApparentPower OBJECT-TYPE
  343. SYNTAX Gauge32(0..9999)
  344. UNITS "volt-amps"
  345. MAX-ACCESS read-only
  346. STATUS current
  347. DESCRIPTION
  348. "PDU total apparent power"
  349. ::= { pduMainEntry 10 }
  350.  
  351. pduTotalPowerFactor OBJECT-TYPE
  352. SYNTAX Gauge32(0..100)
  353. UNITS "%"
  354. MAX-ACCESS read-only
  355. STATUS current
  356. DESCRIPTION
  357. "PDU total power factor"
  358. ::= { pduMainEntry 11 }
  359.  
  360. pduTotalEnergy OBJECT-TYPE
  361. SYNTAX Gauge32(0..9999000)
  362. UNITS "watt-hours"
  363. MAX-ACCESS read-only
  364. STATUS current
  365. DESCRIPTION
  366. "PDU total accumulated energy in watt-hours"
  367. ::= { pduMainEntry 12 }
  368.  
  369. --###########################################################################################--
  370. --pduPhaseTable--
  371. --###########################################################################################--
  372.  
  373. pduPhaseTable OBJECT-TYPE
  374. SYNTAX SEQUENCE OF PduPhaseEntry
  375. MAX-ACCESS not-accessible
  376. STATUS current
  377. DESCRIPTION
  378. "PDU phases information"
  379. ::= { pdu 2 }
  380.  
  381. pduPhaseEntry OBJECT-TYPE
  382. SYNTAX PduPhaseEntry
  383. MAX-ACCESS not-accessible
  384. STATUS current
  385. DESCRIPTION
  386. "Entry in the pduPhaseTable table: each entry contains an index
  387. and other sensor details"
  388. INDEX { pduPhaseIndex }
  389. ::= { pduPhaseTable 1 }
  390.  
  391. PduPhaseEntry ::= SEQUENCE {
  392. pduPhaseIndex Integer32,
  393. pduPhaseName SnmpAdminString,
  394. pduPhaseLabel SnmpAdminString,
  395. pduPhaseVoltage Gauge32,
  396. pduPhaseCurrent Gauge32,
  397. pduPhaseRealPower Gauge32,
  398. pduPhaseApparentPower Gauge32,
  399. pduPhasePowerFactor Gauge32,
  400. pduPhaseEnergy Gauge32,
  401. pduPhaseBalance Gauge32,
  402. pduPhaseCurrentCrestFactor Gauge32
  403. }
  404.  
  405. pduPhaseIndex OBJECT-TYPE
  406. SYNTAX Integer32(1..100)
  407. MAX-ACCESS not-accessible
  408. STATUS current
  409. DESCRIPTION
  410. "Table entry index value"
  411. ::= { pduPhaseEntry 1 }
  412.  
  413. pduPhaseName OBJECT-TYPE
  414. SYNTAX SnmpAdminString(SIZE (0..25))
  415. MAX-ACCESS read-only
  416. STATUS current
  417. DESCRIPTION
  418. "PDU phase name (factory-assigned)"
  419. ::= { pduPhaseEntry 2 }
  420.  
  421. pduPhaseLabel OBJECT-TYPE
  422. SYNTAX SnmpAdminString(SIZE (1..25))
  423. MAX-ACCESS read-write
  424. STATUS current
  425. DESCRIPTION
  426. "PDU phase label (user-defined)"
  427. ::= { pduPhaseEntry 3 }
  428.  
  429. pduPhaseVoltage OBJECT-TYPE
  430. SYNTAX Gauge32(0..3100)
  431. UNITS "decivolts (rms)"
  432. MAX-ACCESS read-only
  433. STATUS current
  434. DESCRIPTION
  435. "PDU phase voltage in tenths of a volt"
  436. ::= { pduPhaseEntry 4 }
  437.  
  438. pduPhaseCurrent OBJECT-TYPE
  439. SYNTAX Gauge32(0..9900)
  440. UNITS "centiamps (rms)"
  441. MAX-ACCESS read-only
  442. STATUS current
  443. DESCRIPTION
  444. "PDU phase current reading in hundredths of an amp"
  445. ::= { pduPhaseEntry 8 }
  446.  
  447. pduPhaseRealPower OBJECT-TYPE
  448. SYNTAX Gauge32(0..9999)
  449. UNITS "watts"
  450. MAX-ACCESS read-only
  451. STATUS current
  452. DESCRIPTION
  453. "Real power for phase in watts"
  454. ::= { pduPhaseEntry 12 }
  455.  
  456. pduPhaseApparentPower OBJECT-TYPE
  457. SYNTAX Gauge32(0..9999)
  458. UNITS "volt-amps"
  459. MAX-ACCESS read-only
  460. STATUS current
  461. DESCRIPTION
  462. "Apparent power for phase in volt-amps"
  463. ::= { pduPhaseEntry 13 }
  464.  
  465. pduPhasePowerFactor OBJECT-TYPE
  466. SYNTAX Gauge32(0..100)
  467. UNITS "%"
  468. MAX-ACCESS read-only
  469. STATUS current
  470. DESCRIPTION
  471. "Power factor for phase"
  472. ::= { pduPhaseEntry 14 }
  473.  
  474. pduPhaseEnergy OBJECT-TYPE
  475. SYNTAX Gauge32(0..9999000)
  476. UNITS "watt-hours"
  477. MAX-ACCESS read-only
  478. STATUS current
  479. DESCRIPTION
  480. "Accumulated energy for phase in watt-hours"
  481. ::= { pduPhaseEntry 15 }
  482.  
  483. pduPhaseBalance OBJECT-TYPE
  484. SYNTAX Gauge32(0..100)
  485. UNITS "%"
  486. MAX-ACCESS read-only
  487. STATUS current
  488. DESCRIPTION
  489. "Phase balance as percent"
  490. ::= { pduPhaseEntry 17 }
  491.  
  492. pduPhaseCurrentCrestFactor OBJECT-TYPE
  493. SYNTAX Gauge32(0..9999)
  494. MAX-ACCESS read-only
  495. STATUS current
  496. DESCRIPTION
  497. "Current crest factor for phase, in hundredths"
  498. ::= { pduPhaseEntry 19 }
  499.  
  500. --###########################################################################################--
  501. --pduBreakerTable--
  502. --###########################################################################################--
  503.  
  504. pduBreakerTable OBJECT-TYPE
  505. SYNTAX SEQUENCE OF PduBreakerEntry
  506. MAX-ACCESS not-accessible
  507. STATUS current
  508. DESCRIPTION
  509. "PDU breaker information"
  510. ::= { pdu 3 }
  511.  
  512. pduBreakerEntry OBJECT-TYPE
  513. SYNTAX PduBreakerEntry
  514. MAX-ACCESS not-accessible
  515. STATUS current
  516. DESCRIPTION
  517. "Entry in the pduBreakerTable table: each entry contains an index
  518. and other sensor details"
  519. INDEX { pduBreakerIndex }
  520. ::= { pduBreakerTable 1 }
  521.  
  522. PduBreakerEntry ::= SEQUENCE {
  523. pduBreakerIndex Integer32,
  524. pduBreakerName SnmpAdminString,
  525. pduBreakerLabel SnmpAdminString,
  526. pduBreakerCurrent Gauge32,
  527. pduBreakerVoltage Gauge32,
  528. pduBreakerRealPower Gauge32,
  529. pduBreakerApparentPower Gauge32,
  530. pduBreakerPowerFactor Gauge32,
  531. pduBreakerEnergy Gauge32
  532. }
  533.  
  534. pduBreakerIndex OBJECT-TYPE
  535. SYNTAX Integer32(1..100)
  536. MAX-ACCESS not-accessible
  537. STATUS current
  538. DESCRIPTION
  539. "Table entry index value"
  540. ::= { pduBreakerEntry 1 }
  541.  
  542. pduBreakerName OBJECT-TYPE
  543. SYNTAX SnmpAdminString(SIZE (1..25))
  544. MAX-ACCESS read-only
  545. STATUS current
  546. DESCRIPTION
  547. "PDU breaker name (factory-assigned)"
  548. ::= { pduBreakerEntry 2 }
  549.  
  550. pduBreakerLabel OBJECT-TYPE
  551. SYNTAX SnmpAdminString(SIZE (0..25))
  552. MAX-ACCESS read-write
  553. STATUS current
  554. DESCRIPTION
  555. "PDU breaker label (user-defined)"
  556. ::= { pduBreakerEntry 3 }
  557.  
  558. pduBreakerCurrent OBJECT-TYPE
  559. SYNTAX Gauge32(0..9900)
  560. UNITS "centiamps (rms)"
  561. MAX-ACCESS read-only
  562. STATUS current
  563. DESCRIPTION
  564. "PDU breaker current reading in hundredths of an amp"
  565. ::= { pduBreakerEntry 4 }
  566.  
  567. pduBreakerVoltage OBJECT-TYPE
  568. SYNTAX Gauge32(0..3100)
  569. UNITS "decivolts (rms)"
  570. MAX-ACCESS read-only
  571. STATUS current
  572. DESCRIPTION
  573. "PDU breaker voltage in tenths of a volt. This object may not exist on
  574. all platforms, due to hardware differences."
  575. ::= { pduBreakerEntry 8 }
  576.  
  577. pduBreakerRealPower OBJECT-TYPE
  578. SYNTAX Gauge32(0..9999)
  579. UNITS "watts"
  580. MAX-ACCESS read-only
  581. STATUS current
  582. DESCRIPTION
  583. "Real power for breaker in watts. This object may not exist on all
  584. platforms, due to hardware differences."
  585. ::= { pduBreakerEntry 12 }
  586.  
  587. pduBreakerApparentPower OBJECT-TYPE
  588. SYNTAX Gauge32(0..9999)
  589. UNITS "volt-amps"
  590. MAX-ACCESS read-only
  591. STATUS current
  592. DESCRIPTION
  593. "Apparent power for breaker in volt-amps. This object may not exist on
  594. all platforms, due to hardware differences."
  595. ::= { pduBreakerEntry 13 }
  596.  
  597. pduBreakerPowerFactor OBJECT-TYPE
  598. SYNTAX Gauge32(0..100)
  599. UNITS "%"
  600. MAX-ACCESS read-only
  601. STATUS current
  602. DESCRIPTION
  603. "Power factor for breaker. This object may not exist on all platforms,
  604. due to hardware differences."
  605. ::= { pduBreakerEntry 14 }
  606.  
  607. pduBreakerEnergy OBJECT-TYPE
  608. SYNTAX Gauge32(0..9999000)
  609. UNITS "watt-hours"
  610. MAX-ACCESS read-only
  611. STATUS current
  612. DESCRIPTION
  613. "Accumulated energy for breaker in watt-hours. This object may not
  614. exist on all platforms, due to hardware differences."
  615. ::= { pduBreakerEntry 15 }
  616.  
  617. --###########################################################################################--
  618. --pduLineTable--
  619. --###########################################################################################--
  620.  
  621. pduLineTable OBJECT-TYPE
  622. SYNTAX SEQUENCE OF PduLineEntry
  623. MAX-ACCESS not-accessible
  624. STATUS current
  625. DESCRIPTION
  626. "PDU line current information"
  627. ::= { pdu 4 }
  628.  
  629. pduLineEntry OBJECT-TYPE
  630. SYNTAX PduLineEntry
  631. MAX-ACCESS not-accessible
  632. STATUS current
  633. DESCRIPTION
  634. "Entry in the pduLineTable table: each entry contains an index
  635. and other sensor details"
  636. INDEX { pduLineIndex }
  637. ::= { pduLineTable 1 }
  638.  
  639. PduLineEntry ::= SEQUENCE {
  640. pduLineIndex Integer32,
  641. pduLineName SnmpAdminString,
  642. pduLineLabel SnmpAdminString,
  643. pduLineCurrent Gauge32
  644. }
  645.  
  646. pduLineIndex OBJECT-TYPE
  647. SYNTAX Integer32(1..100)
  648. MAX-ACCESS not-accessible
  649. STATUS current
  650. DESCRIPTION
  651. "Table entry index value"
  652. ::= { pduLineEntry 1 }
  653.  
  654. pduLineName OBJECT-TYPE
  655. SYNTAX SnmpAdminString(SIZE (1..25))
  656. MAX-ACCESS read-only
  657. STATUS current
  658. DESCRIPTION
  659. "PDU line name (factory-assigned)"
  660. ::= { pduLineEntry 2 }
  661.  
  662. pduLineLabel OBJECT-TYPE
  663. SYNTAX SnmpAdminString(SIZE (0..25))
  664. MAX-ACCESS read-write
  665. STATUS current
  666. DESCRIPTION
  667. "PDU line label (user-defined)"
  668. ::= { pduLineEntry 3 }
  669.  
  670. pduLineCurrent OBJECT-TYPE
  671. SYNTAX Gauge32(0..9900)
  672. UNITS "centiamps (rms)"
  673. MAX-ACCESS read-only
  674. STATUS current
  675. DESCRIPTION
  676. "PDU line current reading in hundredths of an amp"
  677. ::= { pduLineEntry 4 }
  678.  
  679. --###########################################################################################--
  680. --pduOutletSwitchTable--
  681. --###########################################################################################--
  682.  
  683. pduOutletSwitchTable OBJECT-TYPE
  684. SYNTAX SEQUENCE OF PduOutletSwitchEntry
  685. MAX-ACCESS not-accessible
  686. STATUS current
  687. DESCRIPTION
  688. "Data, config and control for outlets with switching"
  689. ::= { pdu 5 }
  690.  
  691. pduOutletSwitchEntry OBJECT-TYPE
  692. SYNTAX PduOutletSwitchEntry
  693. MAX-ACCESS not-accessible
  694. STATUS current
  695. DESCRIPTION
  696. "Entry in the pduOutletSwitchTable table: each entry contains an index
  697. and other sensor details"
  698. INDEX { pduOutletSwitchIndex }
  699. ::= { pduOutletSwitchTable 1 }
  700.  
  701. PduOutletSwitchEntry ::= SEQUENCE {
  702. pduOutletSwitchIndex Integer32,
  703. pduOutletSwitchName SnmpAdminString,
  704. pduOutletSwitchLabel SnmpAdminString,
  705. pduOutletSwitchState INTEGER,
  706. pduOutletSwitchRelayFailure TruthValue,
  707. pduOutletSwitchControl INTEGER,
  708. pduOutletSwitchTimeToAction Integer32,
  709. pduOutletSwitchOnDelay Integer32,
  710. pduOutletSwitchOffDelay Integer32,
  711. pduOutletSwitchRebootDelay Integer32,
  712. pduOutletSwitchRebootHoldDelay Integer32,
  713. pduOutletSwitchPoaAction INTEGER,
  714. pduOutletSwitchPoaDelay Integer32
  715. }
  716.  
  717. pduOutletSwitchIndex OBJECT-TYPE
  718. SYNTAX Integer32(1..100)
  719. MAX-ACCESS not-accessible
  720. STATUS current
  721. DESCRIPTION
  722. "Table entry index value"
  723. ::= { pduOutletSwitchEntry 1 }
  724.  
  725. pduOutletSwitchName OBJECT-TYPE
  726. SYNTAX SnmpAdminString(SIZE (1..25))
  727. MAX-ACCESS read-only
  728. STATUS current
  729. DESCRIPTION
  730. "PDU outlet name (factory-assigned)"
  731. ::= { pduOutletSwitchEntry 2 }
  732.  
  733. pduOutletSwitchLabel OBJECT-TYPE
  734. SYNTAX SnmpAdminString(SIZE (0..25))
  735. MAX-ACCESS read-write
  736. STATUS current
  737. DESCRIPTION
  738. "PDU outlet label (user-defined)"
  739. ::= { pduOutletSwitchEntry 3 }
  740.  
  741. pduOutletSwitchState OBJECT-TYPE
  742. SYNTAX INTEGER {
  743. on(1),
  744. off(2),
  745. on2off(3),
  746. off2on(4),
  747. rebootOn(5),
  748. rebootOff(6),
  749. unavailable(7)
  750. }
  751. MAX-ACCESS read-only
  752. STATUS current
  753. DESCRIPTION
  754. "Switch state of the outlet:
  755. 1 = Outlet is on
  756. 2 = Outlet is off
  757. 3 = Outlet is on, but will turn off after a delay
  758. 4 = Outlet is off, but will turn on after a delay
  759. 5 = Starting reboot cycle, outlet is on, but will go to the
  760. rebootOff(6) state after a delay
  761. 6 = Rebooting, outlet is off, but it will turn on after a delay
  762. 7 = Cannot get outlet state"
  763. ::= { pduOutletSwitchEntry 4 }
  764.  
  765. pduOutletSwitchRelayFailure OBJECT-TYPE
  766. SYNTAX TruthValue
  767. MAX-ACCESS read-only
  768. STATUS current
  769. DESCRIPTION
  770. "Tells if the outlet relay has failed. In normal operation, the value
  771. will be false(2)."
  772. ::= { pduOutletSwitchEntry 5 }
  773.  
  774. pduOutletSwitchControl OBJECT-TYPE
  775. SYNTAX INTEGER {
  776. cancel(1),
  777. on(2),
  778. onAfterDelay(3),
  779. off(4),
  780. offAfterDelay(5),
  781. reboot(6),
  782. rebootAfterDelay(7),
  783. none(8)
  784. }
  785. MAX-ACCESS read-write
  786. STATUS current
  787. DESCRIPTION
  788. "Used for manual control of the outlet. If the outlet is in manual
  789. mode, this field can be set to one of the following values:
  790. 1 = Cancel pending operation
  791. 2 = Turn outlet on
  792. 3 = After delay (pduOutletSwitchOnDelay), turn outlet on
  793. 4 = Turn outlet off
  794. 5 = After delay (pduOutletSwitchOffDelay), turn outlet off
  795. 6 = Reboot: turn off, delay (pduOutletSwitchRebootHoldDelay), turn
  796. outlet back on
  797. 7 = After delay (pduOutletSwitchRebootDelay), reboot outlet
  798. When not in manual mode, setting this field will give an
  799. inconsistentValue error. Returns none(8) for all get requests."
  800. ::= { pduOutletSwitchEntry 6 }
  801.  
  802. pduOutletSwitchTimeToAction OBJECT-TYPE
  803. SYNTAX Integer32(0..600)
  804. MAX-ACCESS read-only
  805. STATUS current
  806. DESCRIPTION
  807. "Seconds until an outlet state change. The value of
  808. pduOutletSwitchState tells what state the outlet will be set, after
  809. the delay."
  810. ::= { pduOutletSwitchEntry 7 }
  811.  
  812. pduOutletSwitchOnDelay OBJECT-TYPE
  813. SYNTAX Integer32(0..600)
  814. MAX-ACCESS read-write
  815. STATUS current
  816. DESCRIPTION
  817. "Seconds to wait before powering on the outlet, during onAfterDelay(3)
  818. operation. Changing this value has no effect on pending actions."
  819. ::= { pduOutletSwitchEntry 8 }
  820.  
  821. pduOutletSwitchOffDelay OBJECT-TYPE
  822. SYNTAX Integer32(0..600)
  823. MAX-ACCESS read-write
  824. STATUS current
  825. DESCRIPTION
  826. "Seconds to wait before powering off the outlet, during
  827. offAfterDelay(5) operation. Changing this value has no effect on
  828. pending actions."
  829. ::= { pduOutletSwitchEntry 9 }
  830.  
  831. pduOutletSwitchRebootDelay OBJECT-TYPE
  832. SYNTAX Integer32(0..600)
  833. MAX-ACCESS read-write
  834. STATUS current
  835. DESCRIPTION
  836. "Seconds to wait before powering off the outlet, during
  837. rebootAfterDelay(7) operation. Changing this value has no effect on
  838. pending actions. See pduOutletSwitchControl for more info."
  839. ::= { pduOutletSwitchEntry 10 }
  840.  
  841. pduOutletSwitchRebootHoldDelay OBJECT-TYPE
  842. SYNTAX Integer32(0..600)
  843. MAX-ACCESS read-write
  844. STATUS current
  845. DESCRIPTION
  846. "Seconds to hold the outlet off, before powering on the outlet, during
  847. rebootAfterDelay(7) operation. Changing this value has no effect on
  848. pending actions. See pduOutletSwitchControl for more info."
  849. ::= { pduOutletSwitchEntry 11 }
  850.  
  851. pduOutletSwitchPoaAction OBJECT-TYPE
  852. SYNTAX INTEGER {
  853. on(1),
  854. off(2),
  855. last(3)
  856. }
  857. MAX-ACCESS read-write
  858. STATUS current
  859. DESCRIPTION
  860. "The outlet is set to this state during power-up. The action can be
  861. have one the following values:
  862. 1 = Outlet will be turned on
  863. 2 = Outlet will stay off
  864. 3 = Outlet will be set to last known state"
  865. ::= { pduOutletSwitchEntry 12 }
  866.  
  867. pduOutletSwitchPoaDelay OBJECT-TYPE
  868. SYNTAX Integer32(0..600)
  869. MAX-ACCESS read-write
  870. STATUS current
  871. DESCRIPTION
  872. "Seconds to wait before setting the outlet to the
  873. pduOutletSwitchPoaAction state. The delay starts at power-up."
  874. ::= { pduOutletSwitchEntry 13 }
  875.  
  876. --###########################################################################################--
  877. --pduOutletMeterTable--
  878. --###########################################################################################--
  879.  
  880. pduOutletMeterTable OBJECT-TYPE
  881. SYNTAX SEQUENCE OF PduOutletMeterEntry
  882. MAX-ACCESS not-accessible
  883. STATUS current
  884. DESCRIPTION
  885. "Metering data for outlets that support this feature"
  886. ::= { pdu 6 }
  887.  
  888. pduOutletMeterEntry OBJECT-TYPE
  889. SYNTAX PduOutletMeterEntry
  890. MAX-ACCESS not-accessible
  891. STATUS current
  892. DESCRIPTION
  893. "Entry in the pduOutletMeterTable table: each entry contains an index
  894. and other sensor details"
  895. INDEX { pduOutletMeterIndex }
  896. ::= { pduOutletMeterTable 1 }
  897.  
  898. PduOutletMeterEntry ::= SEQUENCE {
  899. pduOutletMeterIndex Integer32,
  900. pduOutletMeterName SnmpAdminString,
  901. pduOutletMeterLabel SnmpAdminString,
  902. pduOutletMeterVoltage Gauge32,
  903. pduOutletMeterCurrent Gauge32,
  904. pduOutletMeterRealPower Gauge32,
  905. pduOutletMeterApparentPower Gauge32,
  906. pduOutletMeterPowerFactor Gauge32,
  907. pduOutletMeterEnergy Gauge32,
  908. pduOutletMeterReset INTEGER,
  909. pduOutletCurrentCrestFactor Gauge32
  910. }
  911.  
  912. pduOutletMeterIndex OBJECT-TYPE
  913. SYNTAX Integer32(1..100)
  914. MAX-ACCESS not-accessible
  915. STATUS current
  916. DESCRIPTION
  917. "Table entry index value"
  918. ::= { pduOutletMeterEntry 1 }
  919.  
  920. pduOutletMeterName OBJECT-TYPE
  921. SYNTAX SnmpAdminString(SIZE (1..25))
  922. MAX-ACCESS read-only
  923. STATUS current
  924. DESCRIPTION
  925. "PDU outlet name (factory-assigned)"
  926. ::= { pduOutletMeterEntry 2 }
  927.  
  928. pduOutletMeterLabel OBJECT-TYPE
  929. SYNTAX SnmpAdminString(SIZE (0..25))
  930. MAX-ACCESS read-write
  931. STATUS current
  932. DESCRIPTION
  933. "PDU outlet label (user-defined)"
  934. ::= { pduOutletMeterEntry 3 }
  935.  
  936. pduOutletMeterVoltage OBJECT-TYPE
  937. SYNTAX Gauge32(0..3100)
  938. UNITS "decivolts (rms)"
  939. MAX-ACCESS read-only
  940. STATUS current
  941. DESCRIPTION
  942. "PDU outlet voltage in tenths of a volt"
  943. ::= { pduOutletMeterEntry 4 }
  944.  
  945. pduOutletMeterCurrent OBJECT-TYPE
  946. SYNTAX Gauge32(0..9900)
  947. UNITS "centiamps (rms)"
  948. MAX-ACCESS read-only
  949. STATUS current
  950. DESCRIPTION
  951. "PDU outlet current reading in hundredths of an amp"
  952. ::= { pduOutletMeterEntry 8 }
  953.  
  954. pduOutletMeterRealPower OBJECT-TYPE
  955. SYNTAX Gauge32(0..9999)
  956. UNITS "watts"
  957. MAX-ACCESS read-only
  958. STATUS current
  959. DESCRIPTION
  960. "Real power for outlet in watts"
  961. ::= { pduOutletMeterEntry 12 }
  962.  
  963. pduOutletMeterApparentPower OBJECT-TYPE
  964. SYNTAX Gauge32(0..9999)
  965. UNITS "volt-amps"
  966. MAX-ACCESS read-only
  967. STATUS current
  968. DESCRIPTION
  969. "Apparent power for outlet in volt-amps"
  970. ::= { pduOutletMeterEntry 13 }
  971.  
  972. pduOutletMeterPowerFactor OBJECT-TYPE
  973. SYNTAX Gauge32(0..100)
  974. UNITS "%"
  975. MAX-ACCESS read-only
  976. STATUS current
  977. DESCRIPTION
  978. "Power factor for outlet"
  979. ::= { pduOutletMeterEntry 14 }
  980.  
  981. pduOutletMeterEnergy OBJECT-TYPE
  982. SYNTAX Gauge32(0..9999000)
  983. UNITS "watt-hours"
  984. MAX-ACCESS read-only
  985. STATUS current
  986. DESCRIPTION
  987. "Accumulated energy for outlet in watt-hours"
  988. ::= { pduOutletMeterEntry 15 }
  989.  
  990. pduOutletMeterReset OBJECT-TYPE
  991. SYNTAX INTEGER {
  992. resetEnergy(1),
  993. none(8)
  994. }
  995. MAX-ACCESS read-write
  996. STATUS current
  997. DESCRIPTION
  998. "Used to reset energy. If read, the value is none(8). It can be set to
  999. resetEnergy(1), which sets outlet energy to 0"
  1000. ::= { pduOutletMeterEntry 16 }
  1001.  
  1002. pduOutletCurrentCrestFactor OBJECT-TYPE
  1003. SYNTAX Gauge32(0..9999)
  1004. MAX-ACCESS read-only
  1005. STATUS current
  1006. DESCRIPTION
  1007. "Current crest factor for outlet, in hundredths"
  1008. ::= { pduOutletMeterEntry 19 }
  1009.  
  1010. --###########################################################################################--
  1011. --tempSensorTable--
  1012. --###########################################################################################--
  1013.  
  1014. tempSensorTable OBJECT-TYPE
  1015. SYNTAX SEQUENCE OF TempSensorEntry
  1016. MAX-ACCESS not-accessible
  1017. STATUS current
  1018. DESCRIPTION
  1019. "Remote Temperature (RT) sensor"
  1020. ::= { imd 4 }
  1021.  
  1022. tempSensorEntry OBJECT-TYPE
  1023. SYNTAX TempSensorEntry
  1024. MAX-ACCESS not-accessible
  1025. STATUS current
  1026. DESCRIPTION
  1027. "Entry in the tempSensorTable table: each entry contains an index
  1028. and other sensor details"
  1029. INDEX { tempSensorIndex }
  1030. ::= { tempSensorTable 1 }
  1031.  
  1032. TempSensorEntry ::= SEQUENCE {
  1033. tempSensorIndex Integer32,
  1034. tempSensorSerial DisplayString,
  1035. tempSensorLabel SnmpAdminString,
  1036. tempSensorAvail Gauge32,
  1037. tempSensorTemp Integer32
  1038. }
  1039.  
  1040. tempSensorIndex OBJECT-TYPE
  1041. SYNTAX Integer32(1..100)
  1042. MAX-ACCESS not-accessible
  1043. STATUS current
  1044. DESCRIPTION
  1045. "Table entry index value"
  1046. ::= { tempSensorEntry 1 }
  1047.  
  1048. tempSensorSerial OBJECT-TYPE
  1049. SYNTAX DisplayString
  1050. MAX-ACCESS read-only
  1051. STATUS current
  1052. DESCRIPTION
  1053. "Serial number"
  1054. ::= { tempSensorEntry 2 }
  1055.  
  1056. tempSensorLabel OBJECT-TYPE
  1057. SYNTAX SnmpAdminString(SIZE (0..25))
  1058. MAX-ACCESS read-write
  1059. STATUS current
  1060. DESCRIPTION
  1061. "User-defined label"
  1062. ::= { tempSensorEntry 3 }
  1063.  
  1064. tempSensorAvail OBJECT-TYPE
  1065. SYNTAX Gauge32
  1066. MAX-ACCESS read-only
  1067. STATUS current
  1068. DESCRIPTION
  1069. "Device availability:
  1070. 0 = Unavailable
  1071. 1 = Available
  1072. 2 = Partially Unavailable"
  1073. ::= { tempSensorEntry 4 }
  1074.  
  1075. tempSensorTemp OBJECT-TYPE
  1076. SYNTAX Integer32(-400..2540)
  1077. UNITS "decidegrees"
  1078. MAX-ACCESS read-only
  1079. STATUS current
  1080. DESCRIPTION
  1081. "Temperature in tenths of a degree. Units are given by temperatureUnits
  1082. field in deviceInfo."
  1083. ::= { tempSensorEntry 5 }
  1084.  
  1085. --###########################################################################################--
  1086. --airFlowSensorTable--
  1087. --###########################################################################################--
  1088.  
  1089. airFlowSensorTable OBJECT-TYPE
  1090. SYNTAX SEQUENCE OF AirFlowSensorEntry
  1091. MAX-ACCESS not-accessible
  1092. STATUS current
  1093. DESCRIPTION
  1094. "Remote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor"
  1095. ::= { imd 5 }
  1096.  
  1097. airFlowSensorEntry OBJECT-TYPE
  1098. SYNTAX AirFlowSensorEntry
  1099. MAX-ACCESS not-accessible
  1100. STATUS current
  1101. DESCRIPTION
  1102. "Entry in the airFlowSensorTable table: each entry contains an index
  1103. and other sensor details"
  1104. INDEX { airFlowSensorIndex }
  1105. ::= { airFlowSensorTable 1 }
  1106.  
  1107. AirFlowSensorEntry ::= SEQUENCE {
  1108. airFlowSensorIndex Integer32,
  1109. airFlowSensorSerial DisplayString,
  1110. airFlowSensorLabel SnmpAdminString,
  1111. airFlowSensorAvail Gauge32,
  1112. airFlowSensorTemp Integer32,
  1113. airFlowSensorFlow Integer32,
  1114. airFlowSensorHumidity Integer32,
  1115. airFlowSensorDewPoint Integer32
  1116. }
  1117.  
  1118. airFlowSensorIndex OBJECT-TYPE
  1119. SYNTAX Integer32(1..100)
  1120. MAX-ACCESS not-accessible
  1121. STATUS current
  1122. DESCRIPTION
  1123. "Table entry index value"
  1124. ::= { airFlowSensorEntry 1 }
  1125.  
  1126. airFlowSensorSerial OBJECT-TYPE
  1127. SYNTAX DisplayString
  1128. MAX-ACCESS read-only
  1129. STATUS current
  1130. DESCRIPTION
  1131. "Serial number"
  1132. ::= { airFlowSensorEntry 2 }
  1133.  
  1134. airFlowSensorLabel OBJECT-TYPE
  1135. SYNTAX SnmpAdminString(SIZE (0..25))
  1136. MAX-ACCESS read-write
  1137. STATUS current
  1138. DESCRIPTION
  1139. "User-defined label"
  1140. ::= { airFlowSensorEntry 3 }
  1141.  
  1142. airFlowSensorAvail OBJECT-TYPE
  1143. SYNTAX Gauge32
  1144. MAX-ACCESS read-only
  1145. STATUS current
  1146. DESCRIPTION
  1147. "Device availability:
  1148. 0 = Unavailable
  1149. 1 = Available
  1150. 2 = Partially Unavailable"
  1151. ::= { airFlowSensorEntry 4 }
  1152.  
  1153. airFlowSensorTemp OBJECT-TYPE
  1154. SYNTAX Integer32(-400..2540)
  1155. UNITS "decidegrees"
  1156. MAX-ACCESS read-only
  1157. STATUS current
  1158. DESCRIPTION
  1159. "Temperature reading in tenths of a degree. Units are given by
  1160. temperatureUnits field in deviceInfo."
  1161. ::= { airFlowSensorEntry 5 }
  1162.  
  1163. airFlowSensorFlow OBJECT-TYPE
  1164. SYNTAX Integer32(0..100)
  1165. MAX-ACCESS read-only
  1166. STATUS current
  1167. DESCRIPTION
  1168. "Airflow reading. Still air will be less than 20, while rushing air
  1169. will be around 100."
  1170. ::= { airFlowSensorEntry 6 }
  1171.  
  1172. airFlowSensorHumidity OBJECT-TYPE
  1173. SYNTAX Integer32(0..100)
  1174. UNITS "%"
  1175. MAX-ACCESS read-only
  1176. STATUS current
  1177. DESCRIPTION
  1178. "Humidity reading"
  1179. ::= { airFlowSensorEntry 7 }
  1180.  
  1181. airFlowSensorDewPoint OBJECT-TYPE
  1182. SYNTAX Integer32(-400..2540)
  1183. UNITS "decidegrees"
  1184. MAX-ACCESS read-only
  1185. STATUS current
  1186. DESCRIPTION
  1187. "Dewpoint reading in tenths of a degree. Units are given by
  1188. temperatureUnits field in deviceInfo."
  1189. ::= { airFlowSensorEntry 8 }
  1190.  
  1191. --###########################################################################################--
  1192. --t3hdSensorTable--
  1193. --###########################################################################################--
  1194.  
  1195. t3hdSensorTable OBJECT-TYPE
  1196. SYNTAX SEQUENCE OF T3hdSensorEntry
  1197. MAX-ACCESS not-accessible
  1198. STATUS current
  1199. DESCRIPTION
  1200. "Remote Temperature x 3, Humidity and Dewpoint Sensor"
  1201. ::= { imd 8 }
  1202.  
  1203. t3hdSensorEntry OBJECT-TYPE
  1204. SYNTAX T3hdSensorEntry
  1205. MAX-ACCESS not-accessible
  1206. STATUS current
  1207. DESCRIPTION
  1208. "Entry in the t3hdSensorTable table: each entry contains an index
  1209. and other sensor details"
  1210. INDEX { t3hdSensorIndex }
  1211. ::= { t3hdSensorTable 1 }
  1212.  
  1213. T3hdSensorEntry ::= SEQUENCE {
  1214. t3hdSensorIndex Integer32,
  1215. t3hdSensorSerial DisplayString,
  1216. t3hdSensorLabel SnmpAdminString,
  1217. t3hdSensorAvail Gauge32,
  1218. t3hdSensorIntLabel SnmpAdminString,
  1219. t3hdSensorIntTemp Integer32,
  1220. t3hdSensorIntHumidity Integer32,
  1221. t3hdSensorIntDewPoint Integer32,
  1222. t3hdSensorExtAAvail Gauge32,
  1223. t3hdSensorExtALabel SnmpAdminString,
  1224. t3hdSensorExtATemp Integer32,
  1225. t3hdSensorExtBAvail Gauge32,
  1226. t3hdSensorExtBLabel SnmpAdminString,
  1227. t3hdSensorExtBTemp Integer32
  1228. }
  1229.  
  1230. t3hdSensorIndex OBJECT-TYPE
  1231. SYNTAX Integer32(1..100)
  1232. MAX-ACCESS not-accessible
  1233. STATUS current
  1234. DESCRIPTION
  1235. "Table entry index value"
  1236. ::= { t3hdSensorEntry 1 }
  1237.  
  1238. t3hdSensorSerial OBJECT-TYPE
  1239. SYNTAX DisplayString
  1240. MAX-ACCESS read-only
  1241. STATUS current
  1242. DESCRIPTION
  1243. "Serial number"
  1244. ::= { t3hdSensorEntry 2 }
  1245.  
  1246. t3hdSensorLabel OBJECT-TYPE
  1247. SYNTAX SnmpAdminString(SIZE (0..25))
  1248. MAX-ACCESS read-write
  1249. STATUS current
  1250. DESCRIPTION
  1251. "User-defined label"
  1252. ::= { t3hdSensorEntry 3 }
  1253.  
  1254. t3hdSensorAvail OBJECT-TYPE
  1255. SYNTAX Gauge32
  1256. MAX-ACCESS read-only
  1257. STATUS current
  1258. DESCRIPTION
  1259. "Device availability:
  1260. 0 = Unavailable
  1261. 1 = Available
  1262. 2 = Partially Unavailable"
  1263. ::= { t3hdSensorEntry 4 }
  1264.  
  1265. t3hdSensorIntLabel OBJECT-TYPE
  1266. SYNTAX SnmpAdminString(SIZE (0..25))
  1267. MAX-ACCESS read-write
  1268. STATUS current
  1269. DESCRIPTION
  1270. "Internal label (user-defined)"
  1271. ::= { t3hdSensorEntry 5 }
  1272.  
  1273. t3hdSensorIntTemp OBJECT-TYPE
  1274. SYNTAX Integer32(-400..2540)
  1275. UNITS "decidegrees"
  1276. MAX-ACCESS read-only
  1277. STATUS current
  1278. DESCRIPTION
  1279. "Internal temperature in tenths of a degree. Units are given by
  1280. temperatureUnits field in deviceInfo."
  1281. ::= { t3hdSensorEntry 6 }
  1282.  
  1283. t3hdSensorIntHumidity OBJECT-TYPE
  1284. SYNTAX Integer32(0..100)
  1285. UNITS "%"
  1286. MAX-ACCESS read-only
  1287. STATUS current
  1288. DESCRIPTION
  1289. "Internal humidity"
  1290. ::= { t3hdSensorEntry 7 }
  1291.  
  1292. t3hdSensorIntDewPoint OBJECT-TYPE
  1293. SYNTAX Integer32(-400..2540)
  1294. UNITS "decidegrees"
  1295. MAX-ACCESS read-only
  1296. STATUS current
  1297. DESCRIPTION
  1298. "Internal dewpoint in tenths of a degree. Units are given by
  1299. temperatureUnits field in deviceInfo."
  1300. ::= { t3hdSensorEntry 8 }
  1301.  
  1302. t3hdSensorExtAAvail OBJECT-TYPE
  1303. SYNTAX Gauge32
  1304. MAX-ACCESS read-only
  1305. STATUS current
  1306. DESCRIPTION
  1307. "External A status:
  1308. 0 = Unavailable
  1309. 1 = Available"
  1310. ::= { t3hdSensorEntry 9 }
  1311.  
  1312. t3hdSensorExtALabel OBJECT-TYPE
  1313. SYNTAX SnmpAdminString(SIZE (0..25))
  1314. MAX-ACCESS read-write
  1315. STATUS current
  1316. DESCRIPTION
  1317. "External A label (user-defined)"
  1318. ::= { t3hdSensorEntry 10 }
  1319.  
  1320. t3hdSensorExtATemp OBJECT-TYPE
  1321. SYNTAX Integer32(-400..2540)
  1322. UNITS "decidegrees"
  1323. MAX-ACCESS read-only
  1324. STATUS current
  1325. DESCRIPTION
  1326. "External A temperature in tenths of a degree. Units are given by
  1327. temperatureUnits field in deviceInfo."
  1328. ::= { t3hdSensorEntry 11 }
  1329.  
  1330. t3hdSensorExtBAvail OBJECT-TYPE
  1331. SYNTAX Gauge32
  1332. MAX-ACCESS read-only
  1333. STATUS current
  1334. DESCRIPTION
  1335. "External B status:
  1336. 0 = Unavailable
  1337. 1 = Available"
  1338. ::= { t3hdSensorEntry 12 }
  1339.  
  1340. t3hdSensorExtBLabel OBJECT-TYPE
  1341. SYNTAX SnmpAdminString(SIZE (0..25))
  1342. MAX-ACCESS read-write
  1343. STATUS current
  1344. DESCRIPTION
  1345. "External B label (user-defined)"
  1346. ::= { t3hdSensorEntry 13 }
  1347.  
  1348. t3hdSensorExtBTemp OBJECT-TYPE
  1349. SYNTAX Integer32(-400..2540)
  1350. UNITS "decidegrees"
  1351. MAX-ACCESS read-only
  1352. STATUS current
  1353. DESCRIPTION
  1354. "External B temperature in tenths of a degree. Units are given by
  1355. temperatureUnits field in deviceInfo."
  1356. ::= { t3hdSensorEntry 14 }
  1357.  
  1358. --###########################################################################################--
  1359. --thdSensorTable--
  1360. --###########################################################################################--
  1361.  
  1362. thdSensorTable OBJECT-TYPE
  1363. SYNTAX SEQUENCE OF ThdSensorEntry
  1364. MAX-ACCESS not-accessible
  1365. STATUS current
  1366. DESCRIPTION
  1367. "Remote Temperature, Humidity, and Dewpoint (THD) Sensor"
  1368. ::= { imd 9 }
  1369.  
  1370. thdSensorEntry OBJECT-TYPE
  1371. SYNTAX ThdSensorEntry
  1372. MAX-ACCESS not-accessible
  1373. STATUS current
  1374. DESCRIPTION
  1375. "Entry in the thdSensorTable table: each entry contains an index
  1376. and other sensor details"
  1377. INDEX { thdSensorIndex }
  1378. ::= { thdSensorTable 1 }
  1379.  
  1380. ThdSensorEntry ::= SEQUENCE {
  1381. thdSensorIndex Integer32,
  1382. thdSensorSerial DisplayString,
  1383. thdSensorLabel SnmpAdminString,
  1384. thdSensorAvail Gauge32,
  1385. thdSensorTemp Integer32,
  1386. thdSensorHumidity Integer32,
  1387. thdSensorDewPoint Integer32
  1388. }
  1389.  
  1390. thdSensorIndex OBJECT-TYPE
  1391. SYNTAX Integer32(1..100)
  1392. MAX-ACCESS not-accessible
  1393. STATUS current
  1394. DESCRIPTION
  1395. "Table entry index value"
  1396. ::= { thdSensorEntry 1 }
  1397.  
  1398. thdSensorSerial OBJECT-TYPE
  1399. SYNTAX DisplayString
  1400. MAX-ACCESS read-only
  1401. STATUS current
  1402. DESCRIPTION
  1403. "Serial number"
  1404. ::= { thdSensorEntry 2 }
  1405.  
  1406. thdSensorLabel OBJECT-TYPE
  1407. SYNTAX SnmpAdminString(SIZE (0..25))
  1408. MAX-ACCESS read-write
  1409. STATUS current
  1410. DESCRIPTION
  1411. "User-defined label"
  1412. ::= { thdSensorEntry 3 }
  1413.  
  1414. thdSensorAvail OBJECT-TYPE
  1415. SYNTAX Gauge32
  1416. MAX-ACCESS read-only
  1417. STATUS current
  1418. DESCRIPTION
  1419. "Device availability:
  1420. 0 = Unavailable
  1421. 1 = Available
  1422. 2 = Partially Unavailable"
  1423. ::= { thdSensorEntry 4 }
  1424.  
  1425. thdSensorTemp OBJECT-TYPE
  1426. SYNTAX Integer32(-400..2540)
  1427. UNITS "decidegrees"
  1428. MAX-ACCESS read-only
  1429. STATUS current
  1430. DESCRIPTION
  1431. "Temperature value in tenths of a degree. Units are given by
  1432. temperatureUnits field in deviceInfo."
  1433. ::= { thdSensorEntry 5 }
  1434.  
  1435. thdSensorHumidity OBJECT-TYPE
  1436. SYNTAX Integer32(0..100)
  1437. UNITS "%"
  1438. MAX-ACCESS read-only
  1439. STATUS current
  1440. DESCRIPTION
  1441. "Humidity value"
  1442. ::= { thdSensorEntry 6 }
  1443.  
  1444. thdSensorDewPoint OBJECT-TYPE
  1445. SYNTAX Integer32(-400..2540)
  1446. UNITS "decidegrees"
  1447. MAX-ACCESS read-only
  1448. STATUS current
  1449. DESCRIPTION
  1450. "Dewpoint value in tenths of a degree. Units are given by
  1451. temperatureUnits field in deviceInfo."
  1452. ::= { thdSensorEntry 7 }
  1453.  
  1454. --###########################################################################################--
  1455. --a2dSensorTable--
  1456. --###########################################################################################--
  1457.  
  1458. a2dSensorTable OBJECT-TYPE
  1459. SYNTAX SEQUENCE OF A2dSensorEntry
  1460. MAX-ACCESS not-accessible
  1461. STATUS current
  1462. DESCRIPTION
  1463. "Analog measurement (A2D) sensor (voltage, current, or dry-contact)"
  1464. ::= { imd 11 }
  1465.  
  1466. a2dSensorEntry OBJECT-TYPE
  1467. SYNTAX A2dSensorEntry
  1468. MAX-ACCESS not-accessible
  1469. STATUS current
  1470. DESCRIPTION
  1471. "Entry in the a2dSensorTable table: each entry contains an index
  1472. and other sensor details"
  1473. INDEX { a2dSensorIndex }
  1474. ::= { a2dSensorTable 1 }
  1475.  
  1476. A2dSensorEntry ::= SEQUENCE {
  1477. a2dSensorIndex Integer32,
  1478. a2dSensorSerial DisplayString,
  1479. a2dSensorLabel SnmpAdminString,
  1480. a2dSensorAvail Gauge32,
  1481. a2dSensorValue Integer32,
  1482. a2dSensorDisplayValue SnmpAdminString,
  1483. a2dSensorMode INTEGER,
  1484. a2dSensorUnits SnmpAdminString,
  1485. a2dSensorMin Integer32,
  1486. a2dSensorMax Integer32,
  1487. a2dSensorLowLabel SnmpAdminString,
  1488. a2dSensorHighLabel SnmpAdminString,
  1489. a2dSensorAnalogLabel SnmpAdminString
  1490. }
  1491.  
  1492. a2dSensorIndex OBJECT-TYPE
  1493. SYNTAX Integer32(1..100)
  1494. MAX-ACCESS not-accessible
  1495. STATUS current
  1496. DESCRIPTION
  1497. "Table entry index value"
  1498. ::= { a2dSensorEntry 1 }
  1499.  
  1500. a2dSensorSerial OBJECT-TYPE
  1501. SYNTAX DisplayString
  1502. MAX-ACCESS read-only
  1503. STATUS current
  1504. DESCRIPTION
  1505. "Serial number"
  1506. ::= { a2dSensorEntry 2 }
  1507.  
  1508. a2dSensorLabel OBJECT-TYPE
  1509. SYNTAX SnmpAdminString(SIZE (0..25))
  1510. MAX-ACCESS read-write
  1511. STATUS current
  1512. DESCRIPTION
  1513. "User-defined label"
  1514. ::= { a2dSensorEntry 3 }
  1515.  
  1516. a2dSensorAvail OBJECT-TYPE
  1517. SYNTAX Gauge32
  1518. MAX-ACCESS read-only
  1519. STATUS current
  1520. DESCRIPTION
  1521. "Device availability:
  1522. 0 = Unavailable
  1523. 1 = Available
  1524. 2 = Partially Unavailable"
  1525. ::= { a2dSensorEntry 4 }
  1526.  
  1527. a2dSensorValue OBJECT-TYPE
  1528. SYNTAX Integer32(-1000000..1000000)
  1529. MAX-ACCESS read-only
  1530. STATUS current
  1531. DESCRIPTION
  1532. "Analog measurement value, within either a user-defined or preset
  1533. range, depending on a2dSensorMode."
  1534. ::= { a2dSensorEntry 5 }
  1535.  
  1536. a2dSensorDisplayValue OBJECT-TYPE
  1537. SYNTAX SnmpAdminString(SIZE (0..25))
  1538. MAX-ACCESS read-only
  1539. STATUS current
  1540. DESCRIPTION
  1541. "For current/voltage modes, the analog value is given as a string. In
  1542. binary modes, the value is either a2dSensorLowLabel or
  1543. a2dSensorHighLabel, based on a2dSensorValue."
  1544. ::= { a2dSensorEntry 6 }
  1545.  
  1546. a2dSensorMode OBJECT-TYPE
  1547. SYNTAX INTEGER {
  1548. door(1),
  1549. powerFailure(2),
  1550. flood(3),
  1551. wscLeak(4),
  1552. wscFault(5),
  1553. smoke(6),
  1554. ivsNegGnd(7),
  1555. ivsPosGnd(8),
  1556. customVoltage(9),
  1557. customBinary(10),
  1558. customCurrent(11)
  1559. }
  1560. MAX-ACCESS read-write
  1561. STATUS current
  1562. DESCRIPTION
  1563. "Binary modes have two states represented by the values 0 (low) or 1
  1564. (high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel.
  1565. Current and voltage modes provide a scaled value from a2dSensorMin to
  1566. a2dSensorMax.
  1567. Analog modes:
  1568. 1 = Door (binary)
  1569. 2 = Power failure (binary)
  1570. 3 = Flood (binary)
  1571. 4 = Water-sensing cable leak (binary)
  1572. 5 = Water-sensing cable fault (binary)
  1573. 6 = Smoke alarm (binary)
  1574. 7 = Isolated voltage negative ground (voltage)
  1575. 8 = Isolated voltage positive ground (voltage)
  1576. 9 = Custom voltage (voltage)
  1577. 10 = Custom binary (binary)
  1578. 11 = Custom current (current)"
  1579. ::= { a2dSensorEntry 7 }
  1580.  
  1581. a2dSensorUnits OBJECT-TYPE
  1582. SYNTAX SnmpAdminString(SIZE (0..7))
  1583. MAX-ACCESS read-write
  1584. STATUS current
  1585. DESCRIPTION
  1586. "The units for the analog value. If a2dSensorMode is customVoltage(9)
  1587. or customCurrent(11), then this field has a user-defined value.
  1588. Otherwise, the value is fixed, based on mode."
  1589. ::= { a2dSensorEntry 8 }
  1590.  
  1591. a2dSensorMin OBJECT-TYPE
  1592. SYNTAX Integer32(-1000000..1000000)
  1593. MAX-ACCESS read-write
  1594. STATUS current
  1595. DESCRIPTION
  1596. "Minimum analog value, given as an integer. The analog measurement is
  1597. scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is
  1598. customVoltage(9) or customCurrent(11), then this field has a user-
  1599. defined value. Otherwise, the value is fixed, based on mode."
  1600. ::= { a2dSensorEntry 9 }
  1601.  
  1602. a2dSensorMax OBJECT-TYPE
  1603. SYNTAX Integer32(-1000000..1000000)
  1604. MAX-ACCESS read-write
  1605. STATUS current
  1606. DESCRIPTION
  1607. "Maximum analog value, given as an integer. The analog measurement is
  1608. scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is
  1609. customVoltage(9) or customCurrent(11), then this field has a user-
  1610. defined value. Otherwise, the value is fixed, based on mode."
  1611. ::= { a2dSensorEntry 10 }
  1612.  
  1613. a2dSensorLowLabel OBJECT-TYPE
  1614. SYNTAX SnmpAdminString(SIZE (0..25))
  1615. MAX-ACCESS read-write
  1616. STATUS current
  1617. DESCRIPTION
  1618. "Label for 0 (low) binary value. This field is only applicable if
  1619. a2dSensorMode is one of the binary modes. If a2dSensorMode is
  1620. customBinary(10), then this field is user-defined. Otherwise, it has a
  1621. pre-defined value based on the mode."
  1622. ::= { a2dSensorEntry 11 }
  1623.  
  1624. a2dSensorHighLabel OBJECT-TYPE
  1625. SYNTAX SnmpAdminString(SIZE (0..25))
  1626. MAX-ACCESS read-write
  1627. STATUS current
  1628. DESCRIPTION
  1629. "Label for 1 (high) binary value. The field is only applicable if
  1630. a2dSensorMode is one of the binary modes. If a2dSensorMode is
  1631. customBinary(10), then this field is user-defined. Otherwise, it has a
  1632. pre-defined value based on the mode."
  1633. ::= { a2dSensorEntry 12 }
  1634.  
  1635. a2dSensorAnalogLabel OBJECT-TYPE
  1636. SYNTAX SnmpAdminString(SIZE (0..25))
  1637. MAX-ACCESS read-write
  1638. STATUS current
  1639. DESCRIPTION
  1640. "Label for the analog measurement"
  1641. ::= { a2dSensorEntry 13 }
  1642.  
  1643. --###########################################################################################--
  1644. --humiditySensorTable--
  1645. --###########################################################################################--
  1646.  
  1647. humiditySensorTable OBJECT-TYPE
  1648. SYNTAX SEQUENCE OF HumiditySensorEntry
  1649. MAX-ACCESS not-accessible
  1650. STATUS current
  1651. DESCRIPTION
  1652. "Remote humidity sensor"
  1653. ::= { imd 12 }
  1654.  
  1655. humiditySensorEntry OBJECT-TYPE
  1656. SYNTAX HumiditySensorEntry
  1657. MAX-ACCESS not-accessible
  1658. STATUS current
  1659. DESCRIPTION
  1660. "Entry in the humiditySensorTable table: each entry contains an index
  1661. and other sensor details"
  1662. INDEX { humiditySensorIndex }
  1663. ::= { humiditySensorTable 1 }
  1664.  
  1665. HumiditySensorEntry ::= SEQUENCE {
  1666. humiditySensorIndex Integer32,
  1667. humiditySensorSerial DisplayString,
  1668. humiditySensorLabel SnmpAdminString,
  1669. humiditySensorAvail Gauge32,
  1670. humiditySensorValue Integer32
  1671. }
  1672.  
  1673. humiditySensorIndex OBJECT-TYPE
  1674. SYNTAX Integer32(1..100)
  1675. MAX-ACCESS not-accessible
  1676. STATUS current
  1677. DESCRIPTION
  1678. "Table entry index value"
  1679. ::= { humiditySensorEntry 1 }
  1680.  
  1681. humiditySensorSerial OBJECT-TYPE
  1682. SYNTAX DisplayString
  1683. MAX-ACCESS read-only
  1684. STATUS current
  1685. DESCRIPTION
  1686. "Serial number"
  1687. ::= { humiditySensorEntry 2 }
  1688.  
  1689. humiditySensorLabel OBJECT-TYPE
  1690. SYNTAX SnmpAdminString(SIZE (0..25))
  1691. MAX-ACCESS read-write
  1692. STATUS current
  1693. DESCRIPTION
  1694. "User-defined label"
  1695. ::= { humiditySensorEntry 3 }
  1696.  
  1697. humiditySensorAvail OBJECT-TYPE
  1698. SYNTAX Gauge32
  1699. MAX-ACCESS read-only
  1700. STATUS current
  1701. DESCRIPTION
  1702. "Device availability:
  1703. 0 = Unavailable
  1704. 1 = Available
  1705. 2 = Partially Unavailable"
  1706. ::= { humiditySensorEntry 4 }
  1707.  
  1708. humiditySensorValue OBJECT-TYPE
  1709. SYNTAX Integer32(0..100)
  1710. MAX-ACCESS read-only
  1711. STATUS current
  1712. DESCRIPTION
  1713. "Humidity value"
  1714. ::= { humiditySensorEntry 5 }
  1715.  
  1716. --###########################################################################################--
  1717. --sn2dSensorTable--
  1718. --###########################################################################################--
  1719.  
  1720. sn2dSensorTable OBJECT-TYPE
  1721. SYNTAX SEQUENCE OF Sn2dSensorEntry
  1722. MAX-ACCESS not-accessible
  1723. STATUS current
  1724. DESCRIPTION
  1725. "2 Door Switch Sensor (SN-2D)"
  1726. ::= { imd 13 }
  1727.  
  1728. sn2dSensorEntry OBJECT-TYPE
  1729. SYNTAX Sn2dSensorEntry
  1730. MAX-ACCESS not-accessible
  1731. STATUS current
  1732. DESCRIPTION
  1733. "Entry in the sn2dSensorTable table: each entry contains an index
  1734. and other sensor details"
  1735. INDEX { sn2dSensorIndex }
  1736. ::= { sn2dSensorTable 1 }
  1737.  
  1738. Sn2dSensorEntry ::= SEQUENCE {
  1739. sn2dSensorIndex Integer32,
  1740. sn2dSensorSerial DisplayString,
  1741. sn2dSensorLabel SnmpAdminString,
  1742. sn2dSensorAvail Gauge32,
  1743. sn2dSensorDoor1Label SnmpAdminString,
  1744. sn2dSensorDoor1State INTEGER,
  1745. sn2dSensorDoor1DisplayState SnmpAdminString,
  1746. sn2dSensorDoor2Label SnmpAdminString,
  1747. sn2dSensorDoor2State INTEGER,
  1748. sn2dSensorDoor2DisplayState SnmpAdminString
  1749. }
  1750.  
  1751. sn2dSensorIndex OBJECT-TYPE
  1752. SYNTAX Integer32(1..100)
  1753. MAX-ACCESS not-accessible
  1754. STATUS current
  1755. DESCRIPTION
  1756. "Table entry index value"
  1757. ::= { sn2dSensorEntry 1 }
  1758.  
  1759. sn2dSensorSerial OBJECT-TYPE
  1760. SYNTAX DisplayString
  1761. MAX-ACCESS read-only
  1762. STATUS current
  1763. DESCRIPTION
  1764. "Serial number"
  1765. ::= { sn2dSensorEntry 2 }
  1766.  
  1767. sn2dSensorLabel OBJECT-TYPE
  1768. SYNTAX SnmpAdminString(SIZE (0..25))
  1769. MAX-ACCESS read-write
  1770. STATUS current
  1771. DESCRIPTION
  1772. "User-defined label"
  1773. ::= { sn2dSensorEntry 3 }
  1774.  
  1775. sn2dSensorAvail OBJECT-TYPE
  1776. SYNTAX Gauge32
  1777. MAX-ACCESS read-only
  1778. STATUS current
  1779. DESCRIPTION
  1780. "Device availability:
  1781. 0 = Unavailable
  1782. 1 = Available
  1783. 2 = Partially Unavailable"
  1784. ::= { sn2dSensorEntry 4 }
  1785.  
  1786. sn2dSensorDoor1Label OBJECT-TYPE
  1787. SYNTAX SnmpAdminString(SIZE (0..25))
  1788. MAX-ACCESS read-write
  1789. STATUS current
  1790. DESCRIPTION
  1791. "Door switch 1 label"
  1792. ::= { sn2dSensorEntry 5 }
  1793.  
  1794. sn2dSensorDoor1State OBJECT-TYPE
  1795. SYNTAX INTEGER {
  1796. open(1),
  1797. closed(2)
  1798. }
  1799. MAX-ACCESS read-only
  1800. STATUS current
  1801. DESCRIPTION
  1802. "Door switch 1 state:
  1803. 1 = open
  1804. 2 = closed"
  1805. ::= { sn2dSensorEntry 6 }
  1806.  
  1807. sn2dSensorDoor1DisplayState OBJECT-TYPE
  1808. SYNTAX SnmpAdminString(SIZE (0..25))
  1809. MAX-ACCESS read-only
  1810. STATUS current
  1811. DESCRIPTION
  1812. "Door switch 1 state given as a string"
  1813. ::= { sn2dSensorEntry 7 }
  1814.  
  1815. sn2dSensorDoor2Label OBJECT-TYPE
  1816. SYNTAX SnmpAdminString(SIZE (0..25))
  1817. MAX-ACCESS read-write
  1818. STATUS current
  1819. DESCRIPTION
  1820. "Door switch 2 label"
  1821. ::= { sn2dSensorEntry 8 }
  1822.  
  1823. sn2dSensorDoor2State OBJECT-TYPE
  1824. SYNTAX INTEGER {
  1825. open(1),
  1826. closed(2)
  1827. }
  1828. MAX-ACCESS read-only
  1829. STATUS current
  1830. DESCRIPTION
  1831. "Door switch 2 state:
  1832. 1 = open
  1833. 2 = closed"
  1834. ::= { sn2dSensorEntry 9 }
  1835.  
  1836. sn2dSensorDoor2DisplayState OBJECT-TYPE
  1837. SYNTAX SnmpAdminString(SIZE (0..25))
  1838. MAX-ACCESS read-only
  1839. STATUS current
  1840. DESCRIPTION
  1841. "Door switch 2 state given as a string"
  1842. ::= { sn2dSensorEntry 10 }
  1843.  
  1844. --###########################################################################################--
  1845. --cooling--
  1846. --###########################################################################################--
  1847.  
  1848. cooling OBJECT IDENTIFIER ::= { imd 30 }
  1849.  
  1850. --###########################################################################################--
  1851. --vrc--
  1852. --###########################################################################################--
  1853.  
  1854. vrc OBJECT IDENTIFIER ::= { cooling 1 }
  1855.  
  1856. --###########################################################################################--
  1857. --vrcMainTable--
  1858. --###########################################################################################--
  1859.  
  1860. vrcMainTable OBJECT-TYPE
  1861. SYNTAX SEQUENCE OF VrcMainEntry
  1862. MAX-ACCESS not-accessible
  1863. STATUS current
  1864. DESCRIPTION
  1865. "Table that contains general VRC information"
  1866. ::= { vrc 1 }
  1867.  
  1868. vrcMainEntry OBJECT-TYPE
  1869. SYNTAX VrcMainEntry
  1870. MAX-ACCESS not-accessible
  1871. STATUS current
  1872. DESCRIPTION
  1873. "Entry in the vrcMainTable: each entry represents a VRC device"
  1874. INDEX { vrcMainIndex }
  1875. ::= { vrcMainTable 1 }
  1876.  
  1877. VrcMainEntry ::= SEQUENCE {
  1878. vrcMainIndex Integer32,
  1879. vrcMainSerial DisplayString,
  1880. vrcMainName SnmpAdminString,
  1881. vrcMainLabel SnmpAdminString,
  1882. vrcMainAvail Gauge32
  1883. }
  1884.  
  1885. vrcMainIndex OBJECT-TYPE
  1886. SYNTAX Integer32(1..100)
  1887. MAX-ACCESS not-accessible
  1888. STATUS current
  1889. DESCRIPTION
  1890. "Unique id for each entry in the table"
  1891. ::= { vrcMainEntry 1 }
  1892.  
  1893. vrcMainSerial OBJECT-TYPE
  1894. SYNTAX DisplayString
  1895. MAX-ACCESS read-only
  1896. STATUS current
  1897. DESCRIPTION
  1898. "Serial number"
  1899. ::= { vrcMainEntry 2 }
  1900.  
  1901. vrcMainName OBJECT-TYPE
  1902. SYNTAX SnmpAdminString(SIZE (1..25))
  1903. MAX-ACCESS read-only
  1904. STATUS current
  1905. DESCRIPTION
  1906. "VRC name (factory-assigned)"
  1907. ::= { vrcMainEntry 3 }
  1908.  
  1909. vrcMainLabel OBJECT-TYPE
  1910. SYNTAX SnmpAdminString(SIZE (0..25))
  1911. MAX-ACCESS read-write
  1912. STATUS current
  1913. DESCRIPTION
  1914. "VRC label (user-defined)"
  1915. ::= { vrcMainEntry 4 }
  1916.  
  1917. vrcMainAvail OBJECT-TYPE
  1918. SYNTAX Gauge32
  1919. MAX-ACCESS read-only
  1920. STATUS current
  1921. DESCRIPTION
  1922. "Device availability:
  1923. 0 = Unavailable
  1924. 1 = Available
  1925. 2 = Partially Unavailable"
  1926. ::= { vrcMainEntry 5 }
  1927.  
  1928. --###########################################################################################--
  1929. --vrcMainPtTable--
  1930. --###########################################################################################--
  1931.  
  1932. vrcMainPtTable OBJECT-TYPE
  1933. SYNTAX SEQUENCE OF VrcMainPtEntry
  1934. MAX-ACCESS not-accessible
  1935. STATUS current
  1936. DESCRIPTION
  1937. "Table that contains general VRC status"
  1938. ::= { vrc 2 }
  1939.  
  1940. vrcMainPtEntry OBJECT-TYPE
  1941. SYNTAX VrcMainPtEntry
  1942. MAX-ACCESS not-accessible
  1943. STATUS current
  1944. DESCRIPTION
  1945. "Entry in the vrcMainPtTable: each entry contains status data for a VRC
  1946. device"
  1947. INDEX { vrcMainPtIndex }
  1948. ::= { vrcMainPtTable 1 }
  1949.  
  1950. VrcMainPtEntry ::= SEQUENCE {
  1951. vrcMainPtIndex Integer32,
  1952. vrcMainPtRunState INTEGER,
  1953. vrcMainPtEevOpened Integer32,
  1954. vrcMainPtAlarmNumbers Integer32,
  1955. vrcMainPtHistoryAlarmNumbers Integer32,
  1956. vrcMainPtHpAbnRecordCnt Integer32,
  1957. vrcMainPtMonitorBaudrate INTEGER,
  1958. vrcMainPtMonitorAddress Integer32,
  1959. vrcMainPtLp TruthValue,
  1960. vrcMainPtFilterMaintRemind TruthValue,
  1961. vrcMainPtCoolingFlag TruthValue,
  1962. vrcMainPtFirstOnFlag TruthValue,
  1963. vrcMainPtNewAlarmFlag TruthValue,
  1964. vrcMainPtComAlarmOutState TruthValue,
  1965. vrcMainPtHighWaterInput TruthValue,
  1966. vrcMainPtHighWaterAlarm TruthValue,
  1967. vrcMainPtWaterUnderFloorAlarm TruthValue,
  1968. vrcMainPtSwShutDownStatus TruthValue,
  1969. vrcMainPtRemoteShutdown TruthValue,
  1970. vrcMainPtRemoteShutDownFlag TruthValue,
  1971. vrcMainPtRemoteShutDownAlarm TruthValue,
  1972. vrcMainPtHmiShutDownFlag TruthValue,
  1973. vrcMainPtLpAlarm TruthValue,
  1974. vrcMainPtHpAlarm TruthValue,
  1975. vrcMainPtLpFreqAlarm TruthValue,
  1976. vrcMainPtHpFreqAlarm TruthValue,
  1977. vrcMainPtLpSensorFailAlarm TruthValue,
  1978. vrcMainPtHpSensorFailAlarm TruthValue,
  1979. vrcMainPtEevCommFailAlarm TruthValue
  1980. }
  1981.  
  1982. vrcMainPtIndex OBJECT-TYPE
  1983. SYNTAX Integer32(1..100)
  1984. MAX-ACCESS not-accessible
  1985. STATUS current
  1986. DESCRIPTION
  1987. "Unique id for each entry in the table"
  1988. ::= { vrcMainPtEntry 1 }
  1989.  
  1990. vrcMainPtRunState OBJECT-TYPE
  1991. SYNTAX INTEGER {
  1992. on(1),
  1993. off(2)
  1994. }
  1995. MAX-ACCESS read-only
  1996. STATUS current
  1997. DESCRIPTION
  1998. "VRC run state:
  1999. 1 = on
  2000. 2 = off"
  2001. ::= { vrcMainPtEntry 2 }
  2002.  
  2003. vrcMainPtEevOpened OBJECT-TYPE
  2004. SYNTAX Integer32(0..100)
  2005. UNITS "%"
  2006. MAX-ACCESS read-only
  2007. STATUS current
  2008. DESCRIPTION
  2009. "Eev opened value (percent)"
  2010. ::= { vrcMainPtEntry 3 }
  2011.  
  2012. vrcMainPtAlarmNumbers OBJECT-TYPE
  2013. SYNTAX Integer32(-32768..32767)
  2014. MAX-ACCESS read-only
  2015. STATUS current
  2016. DESCRIPTION
  2017. "Alarm numbers value"
  2018. ::= { vrcMainPtEntry 4 }
  2019.  
  2020. vrcMainPtHistoryAlarmNumbers OBJECT-TYPE
  2021. SYNTAX Integer32(-32768..32767)
  2022. MAX-ACCESS read-only
  2023. STATUS current
  2024. DESCRIPTION
  2025. "History alarm numbers value"
  2026. ::= { vrcMainPtEntry 5 }
  2027.  
  2028. vrcMainPtHpAbnRecordCnt OBJECT-TYPE
  2029. SYNTAX Integer32(-32768..32767)
  2030. MAX-ACCESS read-only
  2031. STATUS current
  2032. DESCRIPTION
  2033. "Hp Abnormal record count"
  2034. ::= { vrcMainPtEntry 6 }
  2035.  
  2036. vrcMainPtMonitorBaudrate OBJECT-TYPE
  2037. SYNTAX INTEGER {
  2038. error(1),
  2039. baud1200(2),
  2040. baud2400(3),
  2041. baud4800(4),
  2042. baud9600(5),
  2043. baud19200(6)
  2044. }
  2045. MAX-ACCESS read-only
  2046. STATUS current
  2047. DESCRIPTION
  2048. "Monitor baud rate:
  2049. 1 = error
  2050. 2 = 1200
  2051. 3 = 2400
  2052. 4 = 4800
  2053. 5 = 9600
  2054. 6 = 19200"
  2055. ::= { vrcMainPtEntry 7 }
  2056.  
  2057. vrcMainPtMonitorAddress OBJECT-TYPE
  2058. SYNTAX Integer32(1..247)
  2059. MAX-ACCESS read-only
  2060. STATUS current
  2061. DESCRIPTION
  2062. "Monitor address"
  2063. ::= { vrcMainPtEntry 8 }
  2064.  
  2065. vrcMainPtLp OBJECT-TYPE
  2066. SYNTAX TruthValue
  2067. MAX-ACCESS read-only
  2068. STATUS current
  2069. DESCRIPTION
  2070. "Lp status"
  2071. ::= { vrcMainPtEntry 9 }
  2072.  
  2073. vrcMainPtFilterMaintRemind OBJECT-TYPE
  2074. SYNTAX TruthValue
  2075. MAX-ACCESS read-only
  2076. STATUS current
  2077. DESCRIPTION
  2078. "Filter maintenance reminder status"
  2079. ::= { vrcMainPtEntry 10 }
  2080.  
  2081. vrcMainPtCoolingFlag OBJECT-TYPE
  2082. SYNTAX TruthValue
  2083. MAX-ACCESS read-only
  2084. STATUS current
  2085. DESCRIPTION
  2086. "Cooling flag"
  2087. ::= { vrcMainPtEntry 11 }
  2088.  
  2089. vrcMainPtFirstOnFlag OBJECT-TYPE
  2090. SYNTAX TruthValue
  2091. MAX-ACCESS read-only
  2092. STATUS current
  2093. DESCRIPTION
  2094. "First on flag"
  2095. ::= { vrcMainPtEntry 12 }
  2096.  
  2097. vrcMainPtNewAlarmFlag OBJECT-TYPE
  2098. SYNTAX TruthValue
  2099. MAX-ACCESS read-only
  2100. STATUS current
  2101. DESCRIPTION
  2102. "New alarm flag"
  2103. ::= { vrcMainPtEntry 13 }
  2104.  
  2105. vrcMainPtComAlarmOutState OBJECT-TYPE
  2106. SYNTAX TruthValue
  2107. MAX-ACCESS read-only
  2108. STATUS current
  2109. DESCRIPTION
  2110. "Common alarm output state"
  2111. ::= { vrcMainPtEntry 14 }
  2112.  
  2113. vrcMainPtHighWaterInput OBJECT-TYPE
  2114. SYNTAX TruthValue
  2115. MAX-ACCESS read-only
  2116. STATUS current
  2117. DESCRIPTION
  2118. "High water input"
  2119. ::= { vrcMainPtEntry 15 }
  2120.  
  2121. vrcMainPtHighWaterAlarm OBJECT-TYPE
  2122. SYNTAX TruthValue
  2123. MAX-ACCESS read-only
  2124. STATUS current
  2125. DESCRIPTION
  2126. "High water alarm status"
  2127. ::= { vrcMainPtEntry 16 }
  2128.  
  2129. vrcMainPtWaterUnderFloorAlarm OBJECT-TYPE
  2130. SYNTAX TruthValue
  2131. MAX-ACCESS read-only
  2132. STATUS current
  2133. DESCRIPTION
  2134. "Water under floor alarm status"
  2135. ::= { vrcMainPtEntry 17 }
  2136.  
  2137. vrcMainPtSwShutDownStatus OBJECT-TYPE
  2138. SYNTAX TruthValue
  2139. MAX-ACCESS read-only
  2140. STATUS current
  2141. DESCRIPTION
  2142. "Software shutdown status"
  2143. ::= { vrcMainPtEntry 18 }
  2144.  
  2145. vrcMainPtRemoteShutdown OBJECT-TYPE
  2146. SYNTAX TruthValue
  2147. MAX-ACCESS read-only
  2148. STATUS current
  2149. DESCRIPTION
  2150. "Remote shutdown status"
  2151. ::= { vrcMainPtEntry 19 }
  2152.  
  2153. vrcMainPtRemoteShutDownFlag OBJECT-TYPE
  2154. SYNTAX TruthValue
  2155. MAX-ACCESS read-only
  2156. STATUS current
  2157. DESCRIPTION
  2158. "Remote shutdown flag"
  2159. ::= { vrcMainPtEntry 20 }
  2160.  
  2161. vrcMainPtRemoteShutDownAlarm OBJECT-TYPE
  2162. SYNTAX TruthValue
  2163. MAX-ACCESS read-only
  2164. STATUS current
  2165. DESCRIPTION
  2166. "Remote shutdown alarm status"
  2167. ::= { vrcMainPtEntry 21 }
  2168.  
  2169. vrcMainPtHmiShutDownFlag OBJECT-TYPE
  2170. SYNTAX TruthValue
  2171. MAX-ACCESS read-only
  2172. STATUS current
  2173. DESCRIPTION
  2174. "Hmi shutdown flag"
  2175. ::= { vrcMainPtEntry 22 }
  2176.  
  2177. vrcMainPtLpAlarm OBJECT-TYPE
  2178. SYNTAX TruthValue
  2179. MAX-ACCESS read-only
  2180. STATUS current
  2181. DESCRIPTION
  2182. "Low pressure alarm status"
  2183. ::= { vrcMainPtEntry 23 }
  2184.  
  2185. vrcMainPtHpAlarm OBJECT-TYPE
  2186. SYNTAX TruthValue
  2187. MAX-ACCESS read-only
  2188. STATUS current
  2189. DESCRIPTION
  2190. "High pressure alarm status"
  2191. ::= { vrcMainPtEntry 24 }
  2192.  
  2193. vrcMainPtLpFreqAlarm OBJECT-TYPE
  2194. SYNTAX TruthValue
  2195. MAX-ACCESS read-only
  2196. STATUS current
  2197. DESCRIPTION
  2198. "Low pressure frequently alarm status"
  2199. ::= { vrcMainPtEntry 25 }
  2200.  
  2201. vrcMainPtHpFreqAlarm OBJECT-TYPE
  2202. SYNTAX TruthValue
  2203. MAX-ACCESS read-only
  2204. STATUS current
  2205. DESCRIPTION
  2206. "High pressure frequently alarm status"
  2207. ::= { vrcMainPtEntry 26 }
  2208.  
  2209. vrcMainPtLpSensorFailAlarm OBJECT-TYPE
  2210. SYNTAX TruthValue
  2211. MAX-ACCESS read-only
  2212. STATUS current
  2213. DESCRIPTION
  2214. "Low pressure sensor failure alarm status"
  2215. ::= { vrcMainPtEntry 27 }
  2216.  
  2217. vrcMainPtHpSensorFailAlarm OBJECT-TYPE
  2218. SYNTAX TruthValue
  2219. MAX-ACCESS read-only
  2220. STATUS current
  2221. DESCRIPTION
  2222. "High pressure sensor failure alarm status"
  2223. ::= { vrcMainPtEntry 28 }
  2224.  
  2225. vrcMainPtEevCommFailAlarm OBJECT-TYPE
  2226. SYNTAX TruthValue
  2227. MAX-ACCESS read-only
  2228. STATUS current
  2229. DESCRIPTION
  2230. "Eev communication failure alarm status"
  2231. ::= { vrcMainPtEntry 29 }
  2232.  
  2233. --###########################################################################################--
  2234. --vrcMainCfgTable--
  2235. --###########################################################################################--
  2236.  
  2237. vrcMainCfgTable OBJECT-TYPE
  2238. SYNTAX SEQUENCE OF VrcMainCfgEntry
  2239. MAX-ACCESS not-accessible
  2240. STATUS current
  2241. DESCRIPTION
  2242. "Table that contains general VRC configuration"
  2243. ::= { vrc 3 }
  2244.  
  2245. vrcMainCfgEntry OBJECT-TYPE
  2246. SYNTAX VrcMainCfgEntry
  2247. MAX-ACCESS not-accessible
  2248. STATUS current
  2249. DESCRIPTION
  2250. "Entry in the vrcMainCfgTable: each entry contains general config
  2251. fields for a VRC device"
  2252. INDEX { vrcMainCfgIndex }
  2253. ::= { vrcMainCfgTable 1 }
  2254.  
  2255. VrcMainCfgEntry ::= SEQUENCE {
  2256. vrcMainCfgIndex Integer32,
  2257. vrcMainCfgModelSelect INTEGER,
  2258. vrcMainCfgSystemTimeYear Integer32,
  2259. vrcMainCfgSystemTimeMonth Integer32,
  2260. vrcMainCfgSystemTimeDay Integer32,
  2261. vrcMainCfgSystemTimeHour Integer32,
  2262. vrcMainCfgSystemTimeMin Integer32,
  2263. vrcMainCfgSystemTimeSec Integer32,
  2264. vrcMainCfgEevShtSettingMin Integer32,
  2265. vrcMainCfgEevShtSettingMax Integer32,
  2266. vrcMainCfgEevValveCloseSht Integer32,
  2267. vrcMainCfgEevMopPressSetting Integer32,
  2268. vrcMainCfgLpdt Integer32,
  2269. vrcMainCfgDeadBand Integer32,
  2270. vrcMainCfgOnOffSwitch TruthValue,
  2271. vrcMainCfgVacuumState TruthValue,
  2272. vrcMainCfgControlMode INTEGER,
  2273. vrcMainCfgManualRunEnable TruthValue,
  2274. vrcMainCfgRemShutdownInput TruthValue,
  2275. vrcMainCfgMonitorShutDownFlag TruthValue,
  2276. vrcMainCfgFirstOnPassword Integer32,
  2277. vrcMainCfgFilterMaintSetting TruthValue,
  2278. vrcMainCfgFilterMaintRemindTime Integer32,
  2279. vrcMainCfgFilterMaintRemindCtrl INTEGER,
  2280. vrcMainCfgCommonAlarmOutputDir TruthValue,
  2281. vrcMainCfgHpAbnAlarmSetting Integer32,
  2282. vrcMainCfgLpAlarmCtrl INTEGER,
  2283. vrcMainCfgHpAlarmCtrl INTEGER,
  2284. vrcMainCfgLpFreqAlarmCtrl INTEGER,
  2285. vrcMainCfgHpFreqAlarmCtrl INTEGER,
  2286. vrcMainCfgLpSensorFailAlarmCtrl INTEGER,
  2287. vrcMainCfgHpSensorFailAlarmCtrl INTEGER,
  2288. vrcMainCfgHighWaterAlarmCtrl INTEGER,
  2289. vrcMainCfgRemShutdownAlarmCtrl INTEGER,
  2290. vrcMainCfgEevCommFailAlarmCtrl INTEGER
  2291. }
  2292.  
  2293. vrcMainCfgIndex OBJECT-TYPE
  2294. SYNTAX Integer32(1..100)
  2295. MAX-ACCESS not-accessible
  2296. STATUS current
  2297. DESCRIPTION
  2298. "Unique id for each entry in the table"
  2299. ::= { vrcMainCfgEntry 1 }
  2300.  
  2301. vrcMainCfgModelSelect OBJECT-TYPE
  2302. SYNTAX INTEGER {
  2303. tmLoc(1),
  2304. r035Ap(2),
  2305. r035Ak(3),
  2306. scLoc(4),
  2307. zeroULoc(5),
  2308. r035Ep(6),
  2309. r035Ek(7)
  2310. }
  2311. MAX-ACCESS read-write
  2312. STATUS current
  2313. DESCRIPTION
  2314. "Model Selection:
  2315. 1 = TMM-Local 220V 50/60HZ
  2316. 2 = TMM-Global 208/230V 50/60HZ
  2317. 3 = TMM-Global 120V 50/60HZ
  2318. 4 = SC 220V 50/60HZ
  2319. 5 = 0U 220V 50/60HZ
  2320. 6 = SS 208/230V 50/60HZ
  2321. 7 = SS 120V 50/60HZ"
  2322. ::= { vrcMainCfgEntry 2 }
  2323.  
  2324. vrcMainCfgSystemTimeYear OBJECT-TYPE
  2325. SYNTAX Integer32(2000..2099)
  2326. MAX-ACCESS read-write
  2327. STATUS current
  2328. DESCRIPTION
  2329. "System time - year"
  2330. ::= { vrcMainCfgEntry 3 }
  2331.  
  2332. vrcMainCfgSystemTimeMonth OBJECT-TYPE
  2333. SYNTAX Integer32(1..12)
  2334. MAX-ACCESS read-write
  2335. STATUS current
  2336. DESCRIPTION
  2337. "System time - month"
  2338. ::= { vrcMainCfgEntry 4 }
  2339.  
  2340. vrcMainCfgSystemTimeDay OBJECT-TYPE
  2341. SYNTAX Integer32(1..31)
  2342. MAX-ACCESS read-write
  2343. STATUS current
  2344. DESCRIPTION
  2345. "System time - day"
  2346. ::= { vrcMainCfgEntry 5 }
  2347.  
  2348. vrcMainCfgSystemTimeHour OBJECT-TYPE
  2349. SYNTAX Integer32(0..23)
  2350. MAX-ACCESS read-write
  2351. STATUS current
  2352. DESCRIPTION
  2353. "System time - hour"
  2354. ::= { vrcMainCfgEntry 6 }
  2355.  
  2356. vrcMainCfgSystemTimeMin OBJECT-TYPE
  2357. SYNTAX Integer32(0..59)
  2358. MAX-ACCESS read-write
  2359. STATUS current
  2360. DESCRIPTION
  2361. "System time - minutes"
  2362. ::= { vrcMainCfgEntry 7 }
  2363.  
  2364. vrcMainCfgSystemTimeSec OBJECT-TYPE
  2365. SYNTAX Integer32(0..59)
  2366. MAX-ACCESS read-write
  2367. STATUS current
  2368. DESCRIPTION
  2369. "System time - seconds"
  2370. ::= { vrcMainCfgEntry 8 }
  2371.  
  2372. vrcMainCfgEevShtSettingMin OBJECT-TYPE
  2373. SYNTAX Integer32
  2374. UNITS "decidegrees"
  2375. MAX-ACCESS read-write
  2376. STATUS current
  2377. DESCRIPTION
  2378. "Min Eev sht in tenths of a degree. Units are given by temperatureUnits
  2379. field in deviceInfo. The settable range is determined by the current
  2380. temperature units.
  2381. Celsius: 50 to 200
  2382. Fahrenheit: 90 to 359"
  2383. ::= { vrcMainCfgEntry 9 }
  2384.  
  2385. vrcMainCfgEevShtSettingMax OBJECT-TYPE
  2386. SYNTAX Integer32
  2387. UNITS "decidegrees"
  2388. MAX-ACCESS read-write
  2389. STATUS current
  2390. DESCRIPTION
  2391. "Max Eev sht in tenths of a degree. Units are given by temperatureUnits
  2392. field in deviceInfo. The settable range is determined by the current
  2393. temperature units.
  2394. Celsius: 50 to 200
  2395. Fahrenheit: 90 to 359"
  2396. ::= { vrcMainCfgEntry 10 }
  2397.  
  2398. vrcMainCfgEevValveCloseSht OBJECT-TYPE
  2399. SYNTAX Integer32
  2400. UNITS "decidegrees"
  2401. MAX-ACCESS read-write
  2402. STATUS current
  2403. DESCRIPTION
  2404. "Eev valve close sht in tenths of a degree. Units are given by
  2405. temperatureUnits field in deviceInfo. The settable range is determined
  2406. by the current temperature units.
  2407. Celsius: 0 to 100
  2408. Fahrenheit: 0 to 179"
  2409. ::= { vrcMainCfgEntry 11 }
  2410.  
  2411. vrcMainCfgEevMopPressSetting OBJECT-TYPE
  2412. SYNTAX Integer32(0..200)
  2413. UNITS "decibars"
  2414. MAX-ACCESS read-write
  2415. STATUS current
  2416. DESCRIPTION
  2417. "Eev mop pressure setting in tenths of a bar."
  2418. ::= { vrcMainCfgEntry 12 }
  2419.  
  2420. vrcMainCfgLpdt OBJECT-TYPE
  2421. SYNTAX Integer32(30..600)
  2422. UNITS "seconds"
  2423. MAX-ACCESS read-write
  2424. STATUS current
  2425. DESCRIPTION
  2426. "Low pressure dt in seconds"
  2427. ::= { vrcMainCfgEntry 13 }
  2428.  
  2429. vrcMainCfgDeadBand OBJECT-TYPE
  2430. SYNTAX Integer32
  2431. UNITS "decidegrees"
  2432. MAX-ACCESS read-write
  2433. STATUS current
  2434. DESCRIPTION
  2435. "Dead band in tenths of a degree. Units are given by temperatureUnits
  2436. field in deviceInfo. The settable range is determined by the current
  2437. temperature units.
  2438. Celsius: 0 to 20
  2439. Fahrenheit: 0 to 35"
  2440. ::= { vrcMainCfgEntry 14 }
  2441.  
  2442. vrcMainCfgOnOffSwitch OBJECT-TYPE
  2443. SYNTAX TruthValue
  2444. MAX-ACCESS read-write
  2445. STATUS current
  2446. DESCRIPTION
  2447. "On-off switch"
  2448. ::= { vrcMainCfgEntry 15 }
  2449.  
  2450. vrcMainCfgVacuumState OBJECT-TYPE
  2451. SYNTAX TruthValue
  2452. MAX-ACCESS read-write
  2453. STATUS current
  2454. DESCRIPTION
  2455. "Vacuum state"
  2456. ::= { vrcMainCfgEntry 16 }
  2457.  
  2458. vrcMainCfgControlMode OBJECT-TYPE
  2459. SYNTAX INTEGER {
  2460. supply(1),
  2461. return(2)
  2462. }
  2463. MAX-ACCESS read-write
  2464. STATUS current
  2465. DESCRIPTION
  2466. "Control mode:
  2467. 1 = supply
  2468. 2 = return"
  2469. ::= { vrcMainCfgEntry 17 }
  2470.  
  2471. vrcMainCfgManualRunEnable OBJECT-TYPE
  2472. SYNTAX TruthValue
  2473. MAX-ACCESS read-write
  2474. STATUS current
  2475. DESCRIPTION
  2476. "Manual run enable"
  2477. ::= { vrcMainCfgEntry 18 }
  2478.  
  2479. vrcMainCfgRemShutdownInput OBJECT-TYPE
  2480. SYNTAX TruthValue
  2481. MAX-ACCESS read-write
  2482. STATUS current
  2483. DESCRIPTION
  2484. "Remote shutdown input"
  2485. ::= { vrcMainCfgEntry 19 }
  2486.  
  2487. vrcMainCfgMonitorShutDownFlag OBJECT-TYPE
  2488. SYNTAX TruthValue
  2489. MAX-ACCESS read-write
  2490. STATUS current
  2491. DESCRIPTION
  2492. "Monitor shutdown flag"
  2493. ::= { vrcMainCfgEntry 20 }
  2494.  
  2495. vrcMainCfgFirstOnPassword OBJECT-TYPE
  2496. SYNTAX Integer32(-32768..32767)
  2497. MAX-ACCESS read-write
  2498. STATUS current
  2499. DESCRIPTION
  2500. "First on password value"
  2501. ::= { vrcMainCfgEntry 21 }
  2502.  
  2503. vrcMainCfgFilterMaintSetting OBJECT-TYPE
  2504. SYNTAX TruthValue
  2505. MAX-ACCESS read-write
  2506. STATUS current
  2507. DESCRIPTION
  2508. "Filter maintenance setting"
  2509. ::= { vrcMainCfgEntry 22 }
  2510.  
  2511. vrcMainCfgFilterMaintRemindTime OBJECT-TYPE
  2512. SYNTAX Integer32(30..360)
  2513. UNITS "days"
  2514. MAX-ACCESS read-write
  2515. STATUS current
  2516. DESCRIPTION
  2517. "Time between filter maintenance reminders in days"
  2518. ::= { vrcMainCfgEntry 23 }
  2519.  
  2520. vrcMainCfgFilterMaintRemindCtrl OBJECT-TYPE
  2521. SYNTAX INTEGER {
  2522. close(1),
  2523. suspend(2),
  2524. open(3)
  2525. }
  2526. MAX-ACCESS read-write
  2527. STATUS current
  2528. DESCRIPTION
  2529. "Filter maintenance reminder:
  2530. 1 = close
  2531. 2 = suspend
  2532. 3 = open"
  2533. ::= { vrcMainCfgEntry 24 }
  2534.  
  2535. vrcMainCfgCommonAlarmOutputDir OBJECT-TYPE
  2536. SYNTAX TruthValue
  2537. MAX-ACCESS read-write
  2538. STATUS current
  2539. DESCRIPTION
  2540. "Common alarm output direction"
  2541. ::= { vrcMainCfgEntry 25 }
  2542.  
  2543. vrcMainCfgHpAbnAlarmSetting OBJECT-TYPE
  2544. SYNTAX Integer32(300..360)
  2545. UNITS "decibars"
  2546. MAX-ACCESS read-write
  2547. STATUS current
  2548. DESCRIPTION
  2549. "Abnormal high pressure alarm value in tenths of a bar"
  2550. ::= { vrcMainCfgEntry 26 }
  2551.  
  2552. vrcMainCfgLpAlarmCtrl OBJECT-TYPE
  2553. SYNTAX INTEGER {
  2554. suspend(2),
  2555. open(3)
  2556. }
  2557. MAX-ACCESS read-write
  2558. STATUS current
  2559. DESCRIPTION
  2560. "Low pressure alarm control:
  2561. 2 = suspend
  2562. 3 = open"
  2563. ::= { vrcMainCfgEntry 27 }
  2564.  
  2565. vrcMainCfgHpAlarmCtrl OBJECT-TYPE
  2566. SYNTAX INTEGER {
  2567. suspend(2),
  2568. open(3)
  2569. }
  2570. MAX-ACCESS read-write
  2571. STATUS current
  2572. DESCRIPTION
  2573. "High pressure alarm control:
  2574. 2 = suspend
  2575. 3 = open"
  2576. ::= { vrcMainCfgEntry 28 }
  2577.  
  2578. vrcMainCfgLpFreqAlarmCtrl OBJECT-TYPE
  2579. SYNTAX INTEGER {
  2580. suspend(2),
  2581. open(3)
  2582. }
  2583. MAX-ACCESS read-write
  2584. STATUS current
  2585. DESCRIPTION
  2586. "Low pressure frequently alarm control:
  2587. 2 = suspend
  2588. 3 = open"
  2589. ::= { vrcMainCfgEntry 29 }
  2590.  
  2591. vrcMainCfgHpFreqAlarmCtrl OBJECT-TYPE
  2592. SYNTAX INTEGER {
  2593. suspend(2),
  2594. open(3)
  2595. }
  2596. MAX-ACCESS read-write
  2597. STATUS current
  2598. DESCRIPTION
  2599. "High pressure frequently alarm control:
  2600. 2 = suspend
  2601. 3 = open"
  2602. ::= { vrcMainCfgEntry 30 }
  2603.  
  2604. vrcMainCfgLpSensorFailAlarmCtrl OBJECT-TYPE
  2605. SYNTAX INTEGER {
  2606. suspend(2),
  2607. open(3)
  2608. }
  2609. MAX-ACCESS read-write
  2610. STATUS current
  2611. DESCRIPTION
  2612. "Low pressure sensor failure alarm control:
  2613. 2 = suspend
  2614. 3 = open"
  2615. ::= { vrcMainCfgEntry 31 }
  2616.  
  2617. vrcMainCfgHpSensorFailAlarmCtrl OBJECT-TYPE
  2618. SYNTAX INTEGER {
  2619. suspend(2),
  2620. open(3)
  2621. }
  2622. MAX-ACCESS read-write
  2623. STATUS current
  2624. DESCRIPTION
  2625. "High pressure sensor failure alarm control:
  2626. 2 = suspend
  2627. 3 = open"
  2628. ::= { vrcMainCfgEntry 32 }
  2629.  
  2630. vrcMainCfgHighWaterAlarmCtrl OBJECT-TYPE
  2631. SYNTAX INTEGER {
  2632. close(1),
  2633. suspend(2),
  2634. open(3)
  2635. }
  2636. MAX-ACCESS read-write
  2637. STATUS current
  2638. DESCRIPTION
  2639. "High water alarm control:
  2640. 1 = close
  2641. 2 = suspend
  2642. 3 = open"
  2643. ::= { vrcMainCfgEntry 33 }
  2644.  
  2645. vrcMainCfgRemShutdownAlarmCtrl OBJECT-TYPE
  2646. SYNTAX INTEGER {
  2647. suspend(2),
  2648. open(3)
  2649. }
  2650. MAX-ACCESS read-write
  2651. STATUS current
  2652. DESCRIPTION
  2653. "Remote shutdown alarm control:
  2654. 2 = suspend
  2655. 3 = open"
  2656. ::= { vrcMainCfgEntry 34 }
  2657.  
  2658. vrcMainCfgEevCommFailAlarmCtrl OBJECT-TYPE
  2659. SYNTAX INTEGER {
  2660. suspend(2),
  2661. open(3)
  2662. }
  2663. MAX-ACCESS read-write
  2664. STATUS current
  2665. DESCRIPTION
  2666. "Eev communication failure alarm:
  2667. 2 = suspend
  2668. 3 = open"
  2669. ::= { vrcMainCfgEntry 35 }
  2670.  
  2671. --###########################################################################################--
  2672. --vrcOutFanPtTable--
  2673. --###########################################################################################--
  2674.  
  2675. vrcOutFanPtTable OBJECT-TYPE
  2676. SYNTAX SEQUENCE OF VrcOutFanPtEntry
  2677. MAX-ACCESS not-accessible
  2678. STATUS current
  2679. DESCRIPTION
  2680. "Table that contains VRC out-fan status"
  2681. ::= { vrc 4 }
  2682.  
  2683. vrcOutFanPtEntry OBJECT-TYPE
  2684. SYNTAX VrcOutFanPtEntry
  2685. MAX-ACCESS not-accessible
  2686. STATUS current
  2687. DESCRIPTION
  2688. "Entry in the vrcOutFanPtTable: each entry represents data for a VRC
  2689. out-fan"
  2690. INDEX { vrcOutFanPtIndex }
  2691. ::= { vrcOutFanPtTable 1 }
  2692.  
  2693. VrcOutFanPtEntry ::= SEQUENCE {
  2694. vrcOutFanPtIndex Integer32,
  2695. vrcOutFanPtName SnmpAdminString,
  2696. vrcOutFanPtSpeed Integer32
  2697. }
  2698.  
  2699. vrcOutFanPtIndex OBJECT-TYPE
  2700. SYNTAX Integer32(1..100)
  2701. MAX-ACCESS not-accessible
  2702. STATUS current
  2703. DESCRIPTION
  2704. "Unique id for each entry in the table"
  2705. ::= { vrcOutFanPtEntry 1 }
  2706.  
  2707. vrcOutFanPtName OBJECT-TYPE
  2708. SYNTAX SnmpAdminString(SIZE (1..25))
  2709. MAX-ACCESS read-only
  2710. STATUS current
  2711. DESCRIPTION
  2712. "Out-fan name (factory-assigned)"
  2713. ::= { vrcOutFanPtEntry 2 }
  2714.  
  2715. vrcOutFanPtSpeed OBJECT-TYPE
  2716. SYNTAX Integer32(0..100)
  2717. UNITS "%"
  2718. MAX-ACCESS read-only
  2719. STATUS current
  2720. DESCRIPTION
  2721. "Fan speed (percent)"
  2722. ::= { vrcOutFanPtEntry 3 }
  2723.  
  2724. --###########################################################################################--
  2725. --vrcOutFanCfgTable--
  2726. --###########################################################################################--
  2727.  
  2728. vrcOutFanCfgTable OBJECT-TYPE
  2729. SYNTAX SEQUENCE OF VrcOutFanCfgEntry
  2730. MAX-ACCESS not-accessible
  2731. STATUS current
  2732. DESCRIPTION
  2733. "Table used for VRC out-fan configuration"
  2734. ::= { vrc 5 }
  2735.  
  2736. vrcOutFanCfgEntry OBJECT-TYPE
  2737. SYNTAX VrcOutFanCfgEntry
  2738. MAX-ACCESS not-accessible
  2739. STATUS current
  2740. DESCRIPTION
  2741. "Entry in the vrcOutFanCfgTable: each entry contains config fields for
  2742. a VRC out-fan"
  2743. INDEX { vrcOutFanCfgIndex }
  2744. ::= { vrcOutFanCfgTable 1 }
  2745.  
  2746. VrcOutFanCfgEntry ::= SEQUENCE {
  2747. vrcOutFanCfgIndex Integer32,
  2748. vrcOutFanCfgStartPress Integer32,
  2749. vrcOutFanCfgPressSetting Integer32,
  2750. vrcOutFanCfgMinPowerVoltage Integer32,
  2751. vrcOutFanCfgMaxPowerVoltage Integer32,
  2752. vrcOutFanCfgSpeed Integer32
  2753. }
  2754.  
  2755. vrcOutFanCfgIndex OBJECT-TYPE
  2756. SYNTAX Integer32(1..100)
  2757. MAX-ACCESS not-accessible
  2758. STATUS current
  2759. DESCRIPTION
  2760. "Unique id for each entry in the table"
  2761. ::= { vrcOutFanCfgEntry 1 }
  2762.  
  2763. vrcOutFanCfgStartPress OBJECT-TYPE
  2764. SYNTAX Integer32(190..250)
  2765. UNITS "decibars"
  2766. MAX-ACCESS read-write
  2767. STATUS current
  2768. DESCRIPTION
  2769. "Out-fan start pressure in tenths of a bar"
  2770. ::= { vrcOutFanCfgEntry 2 }
  2771.  
  2772. vrcOutFanCfgPressSetting OBJECT-TYPE
  2773. SYNTAX Integer32(50..80)
  2774. UNITS "decibars"
  2775. MAX-ACCESS read-write
  2776. STATUS current
  2777. DESCRIPTION
  2778. "Out-fan pressure setting in tenths of a bar"
  2779. ::= { vrcOutFanCfgEntry 3 }
  2780.  
  2781. vrcOutFanCfgMinPowerVoltage OBJECT-TYPE
  2782. SYNTAX Integer32(30..50)
  2783. UNITS "%"
  2784. MAX-ACCESS read-write
  2785. STATUS current
  2786. DESCRIPTION
  2787. "Min out-fan voltage (percent)"
  2788. ::= { vrcOutFanCfgEntry 4 }
  2789.  
  2790. vrcOutFanCfgMaxPowerVoltage OBJECT-TYPE
  2791. SYNTAX Integer32(60..100)
  2792. UNITS "%"
  2793. MAX-ACCESS read-write
  2794. STATUS current
  2795. DESCRIPTION
  2796. "Max out-fan voltage (percent)"
  2797. ::= { vrcOutFanCfgEntry 5 }
  2798.  
  2799. vrcOutFanCfgSpeed OBJECT-TYPE
  2800. SYNTAX Integer32(0..100)
  2801. UNITS "%"
  2802. MAX-ACCESS read-write
  2803. STATUS current
  2804. DESCRIPTION
  2805. "Out-fan speed (percent)"
  2806. ::= { vrcOutFanCfgEntry 6 }
  2807.  
  2808. --###########################################################################################--
  2809. --vrcInFanPtTable--
  2810. --###########################################################################################--
  2811.  
  2812. vrcInFanPtTable OBJECT-TYPE
  2813. SYNTAX SEQUENCE OF VrcInFanPtEntry
  2814. MAX-ACCESS not-accessible
  2815. STATUS current
  2816. DESCRIPTION
  2817. "Table that contains VRC in-fan status"
  2818. ::= { vrc 6 }
  2819.  
  2820. vrcInFanPtEntry OBJECT-TYPE
  2821. SYNTAX VrcInFanPtEntry
  2822. MAX-ACCESS not-accessible
  2823. STATUS current
  2824. DESCRIPTION
  2825. "Entry in the vrcInFanPtTable: each entry represents data for a VRC in-
  2826. fan"
  2827. INDEX { vrcInFanPtIndex }
  2828. ::= { vrcInFanPtTable 1 }
  2829.  
  2830. VrcInFanPtEntry ::= SEQUENCE {
  2831. vrcInFanPtIndex Integer32,
  2832. vrcInFanPtName SnmpAdminString,
  2833. vrcInFanPtRunTimeHours Integer32,
  2834. vrcInFanPtStartStopCount Integer32
  2835. }
  2836.  
  2837. vrcInFanPtIndex OBJECT-TYPE
  2838. SYNTAX Integer32(1..100)
  2839. MAX-ACCESS not-accessible
  2840. STATUS current
  2841. DESCRIPTION
  2842. "Unique id for each entry in the table"
  2843. ::= { vrcInFanPtEntry 1 }
  2844.  
  2845. vrcInFanPtName OBJECT-TYPE
  2846. SYNTAX SnmpAdminString(SIZE (1..25))
  2847. MAX-ACCESS read-only
  2848. STATUS current
  2849. DESCRIPTION
  2850. "In-fan name (factory-assigned)"
  2851. ::= { vrcInFanPtEntry 2 }
  2852.  
  2853. vrcInFanPtRunTimeHours OBJECT-TYPE
  2854. SYNTAX Integer32(-32768..32767)
  2855. UNITS "hours"
  2856. MAX-ACCESS read-only
  2857. STATUS current
  2858. DESCRIPTION
  2859. "In-fan run time in hours"
  2860. ::= { vrcInFanPtEntry 3 }
  2861.  
  2862. vrcInFanPtStartStopCount OBJECT-TYPE
  2863. SYNTAX Integer32(-32768..32767)
  2864. MAX-ACCESS read-only
  2865. STATUS current
  2866. DESCRIPTION
  2867. "In-fan start/stop count"
  2868. ::= { vrcInFanPtEntry 4 }
  2869.  
  2870. --###########################################################################################--
  2871. --vrcInFanCfgTable--
  2872. --###########################################################################################--
  2873.  
  2874. vrcInFanCfgTable OBJECT-TYPE
  2875. SYNTAX SEQUENCE OF VrcInFanCfgEntry
  2876. MAX-ACCESS not-accessible
  2877. STATUS current
  2878. DESCRIPTION
  2879. "Table used for VRC in-fan configuration"
  2880. ::= { vrc 7 }
  2881.  
  2882. vrcInFanCfgEntry OBJECT-TYPE
  2883. SYNTAX VrcInFanCfgEntry
  2884. MAX-ACCESS not-accessible
  2885. STATUS current
  2886. DESCRIPTION
  2887. "Entry in the vrcInFanCfgTable: each entry contains config fields for a
  2888. VRC in-fan"
  2889. INDEX { vrcInFanCfgIndex }
  2890. ::= { vrcInFanCfgTable 1 }
  2891.  
  2892. VrcInFanCfgEntry ::= SEQUENCE {
  2893. vrcInFanCfgIndex Integer32,
  2894. vrcInFanCfgOutputStatus TruthValue,
  2895. vrcInFanCfgLowSpeedStep Integer32,
  2896. vrcInFanCfgHighSpeedStep Integer32,
  2897. vrcInFanCfgMinSpeed Integer32,
  2898. vrcInFanCfgStandardSpeed Integer32,
  2899. vrcInFanCfgMinCfc Integer32,
  2900. vrcInFanCfgStandardCfc Integer32,
  2901. vrcInFanCfgStartDelay Integer32,
  2902. vrcInFanCfgStopDelay Integer32,
  2903. vrcInFanCfgReduceSpeedDelay Integer32,
  2904. vrcInFanCfgJumpBand1 Integer32,
  2905. vrcInFanCfgJumpBand2 Integer32,
  2906. vrcInFanCfgJumpBand3 Integer32,
  2907. vrcInFanCfgJumpBand4 Integer32,
  2908. vrcInFanCfgJumpBand5 Integer32,
  2909. vrcInFanCfgJumpFreq1 Integer32,
  2910. vrcInFanCfgJumpFreq2 Integer32,
  2911. vrcInFanCfgJumpFreq3 Integer32,
  2912. vrcInFanCfgJumpFreq4 Integer32,
  2913. vrcInFanCfgJumpFreq5 Integer32,
  2914. vrcInFanCfgTempP Integer32,
  2915. vrcInFanCfgTempI Integer32,
  2916. vrcInFanCfgTempD Integer32
  2917. }
  2918.  
  2919. vrcInFanCfgIndex OBJECT-TYPE
  2920. SYNTAX Integer32(1..100)
  2921. MAX-ACCESS not-accessible
  2922. STATUS current
  2923. DESCRIPTION
  2924. "Unique id for each entry in the table"
  2925. ::= { vrcInFanCfgEntry 1 }
  2926.  
  2927. vrcInFanCfgOutputStatus OBJECT-TYPE
  2928. SYNTAX TruthValue
  2929. MAX-ACCESS read-write
  2930. STATUS current
  2931. DESCRIPTION
  2932. "In-fan output status"
  2933. ::= { vrcInFanCfgEntry 2 }
  2934.  
  2935. vrcInFanCfgLowSpeedStep OBJECT-TYPE
  2936. SYNTAX Integer32(1..20)
  2937. UNITS "0.1%/s"
  2938. MAX-ACCESS read-write
  2939. STATUS current
  2940. DESCRIPTION
  2941. "In-fan low speed step in tenths of a percent per second"
  2942. ::= { vrcInFanCfgEntry 3 }
  2943.  
  2944. vrcInFanCfgHighSpeedStep OBJECT-TYPE
  2945. SYNTAX Integer32(1..50)
  2946. UNITS "0.1%/s"
  2947. MAX-ACCESS read-write
  2948. STATUS current
  2949. DESCRIPTION
  2950. "In-fan high speed step in tenths of a percent per second"
  2951. ::= { vrcInFanCfgEntry 4 }
  2952.  
  2953. vrcInFanCfgMinSpeed OBJECT-TYPE
  2954. SYNTAX Integer32(30..80)
  2955. UNITS "%"
  2956. MAX-ACCESS read-write
  2957. STATUS current
  2958. DESCRIPTION
  2959. "Min in-fan speed (percent)"
  2960. ::= { vrcInFanCfgEntry 5 }
  2961.  
  2962. vrcInFanCfgStandardSpeed OBJECT-TYPE
  2963. SYNTAX Integer32(80..100)
  2964. UNITS "%"
  2965. MAX-ACCESS read-write
  2966. STATUS current
  2967. DESCRIPTION
  2968. "Standard in-fan speed (percent)"
  2969. ::= { vrcInFanCfgEntry 6 }
  2970.  
  2971. vrcInFanCfgMinCfc OBJECT-TYPE
  2972. SYNTAX Integer32(0..30)
  2973. UNITS "%"
  2974. MAX-ACCESS read-write
  2975. STATUS current
  2976. DESCRIPTION
  2977. "Min in-fan cfc (percent)"
  2978. ::= { vrcInFanCfgEntry 7 }
  2979.  
  2980. vrcInFanCfgStandardCfc OBJECT-TYPE
  2981. SYNTAX Integer32(85..100)
  2982. UNITS "%"
  2983. MAX-ACCESS read-write
  2984. STATUS current
  2985. DESCRIPTION
  2986. "Standard in-fan cfc (percent)"
  2987. ::= { vrcInFanCfgEntry 8 }
  2988.  
  2989. vrcInFanCfgStartDelay OBJECT-TYPE
  2990. SYNTAX Integer32(10..600)
  2991. UNITS "seconds"
  2992. MAX-ACCESS read-write
  2993. STATUS current
  2994. DESCRIPTION
  2995. "In-fan start delay in seconds"
  2996. ::= { vrcInFanCfgEntry 9 }
  2997.  
  2998. vrcInFanCfgStopDelay OBJECT-TYPE
  2999. SYNTAX Integer32(10..300)
  3000. UNITS "seconds"
  3001. MAX-ACCESS read-write
  3002. STATUS current
  3003. DESCRIPTION
  3004. "In-fan stop delay in seconds"
  3005. ::= { vrcInFanCfgEntry 10 }
  3006.  
  3007. vrcInFanCfgReduceSpeedDelay OBJECT-TYPE
  3008. SYNTAX Integer32(0..300)
  3009. UNITS "seconds"
  3010. MAX-ACCESS read-write
  3011. STATUS current
  3012. DESCRIPTION
  3013. "In-fan reduce speed delay in seconds"
  3014. ::= { vrcInFanCfgEntry 11 }
  3015.  
  3016. vrcInFanCfgJumpBand1 OBJECT-TYPE
  3017. SYNTAX Integer32(0..100)
  3018. UNITS "0.1%"
  3019. MAX-ACCESS read-write
  3020. STATUS current
  3021. DESCRIPTION
  3022. "In-fan jump band 1 in tenths of a percent"
  3023. ::= { vrcInFanCfgEntry 12 }
  3024.  
  3025. vrcInFanCfgJumpBand2 OBJECT-TYPE
  3026. SYNTAX Integer32(0..100)
  3027. UNITS "0.1%"
  3028. MAX-ACCESS read-write
  3029. STATUS current
  3030. DESCRIPTION
  3031. "In-fan jump band 2 in tenths of a percent"
  3032. ::= { vrcInFanCfgEntry 13 }
  3033.  
  3034. vrcInFanCfgJumpBand3 OBJECT-TYPE
  3035. SYNTAX Integer32(0..100)
  3036. UNITS "0.1%"
  3037. MAX-ACCESS read-write
  3038. STATUS current
  3039. DESCRIPTION
  3040. "In-fan jump band 3 in tenths of a percent"
  3041. ::= { vrcInFanCfgEntry 14 }
  3042.  
  3043. vrcInFanCfgJumpBand4 OBJECT-TYPE
  3044. SYNTAX Integer32(0..100)
  3045. UNITS "0.1%"
  3046. MAX-ACCESS read-write
  3047. STATUS current
  3048. DESCRIPTION
  3049. "In-fan jump band 4 in tenths of a percent"
  3050. ::= { vrcInFanCfgEntry 15 }
  3051.  
  3052. vrcInFanCfgJumpBand5 OBJECT-TYPE
  3053. SYNTAX Integer32(0..100)
  3054. UNITS "0.1%"
  3055. MAX-ACCESS read-write
  3056. STATUS current
  3057. DESCRIPTION
  3058. "In-fan jump band 5 in tenths of a percent"
  3059. ::= { vrcInFanCfgEntry 16 }
  3060.  
  3061. vrcInFanCfgJumpFreq1 OBJECT-TYPE
  3062. SYNTAX Integer32(0..1000)
  3063. UNITS "0.1%"
  3064. MAX-ACCESS read-write
  3065. STATUS current
  3066. DESCRIPTION
  3067. "In-fan jump frequency 1 in tenths of a percent"
  3068. ::= { vrcInFanCfgEntry 17 }
  3069.  
  3070. vrcInFanCfgJumpFreq2 OBJECT-TYPE
  3071. SYNTAX Integer32(0..1000)
  3072. UNITS "0.1%"
  3073. MAX-ACCESS read-write
  3074. STATUS current
  3075. DESCRIPTION
  3076. "In-fan jump frequency 2 in tenths of a percent"
  3077. ::= { vrcInFanCfgEntry 18 }
  3078.  
  3079. vrcInFanCfgJumpFreq3 OBJECT-TYPE
  3080. SYNTAX Integer32(0..1000)
  3081. UNITS "0.1%"
  3082. MAX-ACCESS read-write
  3083. STATUS current
  3084. DESCRIPTION
  3085. "In-fan jump frequency 3 in tenths of a percent"
  3086. ::= { vrcInFanCfgEntry 19 }
  3087.  
  3088. vrcInFanCfgJumpFreq4 OBJECT-TYPE
  3089. SYNTAX Integer32(0..1000)
  3090. UNITS "0.1%"
  3091. MAX-ACCESS read-write
  3092. STATUS current
  3093. DESCRIPTION
  3094. "In-fan jump frequency 4 in tenths of a percent"
  3095. ::= { vrcInFanCfgEntry 20 }
  3096.  
  3097. vrcInFanCfgJumpFreq5 OBJECT-TYPE
  3098. SYNTAX Integer32(0..1000)
  3099. UNITS "0.1%"
  3100. MAX-ACCESS read-write
  3101. STATUS current
  3102. DESCRIPTION
  3103. "In-fan jump frequency 5 in tenths of a percent"
  3104. ::= { vrcInFanCfgEntry 21 }
  3105.  
  3106. vrcInFanCfgTempP OBJECT-TYPE
  3107. SYNTAX Integer32(10..150)
  3108. UNITS "decidegrees"
  3109. MAX-ACCESS read-write
  3110. STATUS current
  3111. DESCRIPTION
  3112. "In-fan temperature P in tenths of a degree. Units are given by
  3113. temperatureUnits field in deviceInfo."
  3114. ::= { vrcInFanCfgEntry 22 }
  3115.  
  3116. vrcInFanCfgTempI OBJECT-TYPE
  3117. SYNTAX Integer32(0..900)
  3118. UNITS "seconds"
  3119. MAX-ACCESS read-write
  3120. STATUS current
  3121. DESCRIPTION
  3122. "In-fan temperature I in seconds"
  3123. ::= { vrcInFanCfgEntry 23 }
  3124.  
  3125. vrcInFanCfgTempD OBJECT-TYPE
  3126. SYNTAX Integer32(0..900)
  3127. UNITS "seconds"
  3128. MAX-ACCESS read-write
  3129. STATUS current
  3130. DESCRIPTION
  3131. "In-fan temperature D in seconds"
  3132. ::= { vrcInFanCfgEntry 24 }
  3133.  
  3134. --###########################################################################################--
  3135. --vrcCompPtTable--
  3136. --###########################################################################################--
  3137.  
  3138. vrcCompPtTable OBJECT-TYPE
  3139. SYNTAX SEQUENCE OF VrcCompPtEntry
  3140. MAX-ACCESS not-accessible
  3141. STATUS current
  3142. DESCRIPTION
  3143. "Table that contains VRC compressor status"
  3144. ::= { vrc 8 }
  3145.  
  3146. vrcCompPtEntry OBJECT-TYPE
  3147. SYNTAX VrcCompPtEntry
  3148. MAX-ACCESS not-accessible
  3149. STATUS current
  3150. DESCRIPTION
  3151. "Entry in the vrcCompPtTable: each entry represents data for a VRC
  3152. compressor"
  3153. INDEX { vrcCompPtIndex }
  3154. ::= { vrcCompPtTable 1 }
  3155.  
  3156. VrcCompPtEntry ::= SEQUENCE {
  3157. vrcCompPtIndex Integer32,
  3158. vrcCompPtName SnmpAdminString,
  3159. vrcCompPtCapacity Integer32,
  3160. vrcCompPtRunTimeHours Integer32,
  3161. vrcCompPtStartStopCount Integer32,
  3162. vrcCompPtDriverFaultU00 TruthValue,
  3163. vrcCompPtDriverFaultU01 TruthValue,
  3164. vrcCompPtDriverFaultU02 TruthValue,
  3165. vrcCompPtDriverFaultU03 TruthValue,
  3166. vrcCompPtDriverFaultU04 TruthValue,
  3167. vrcCompPtDriverFaultU05 TruthValue,
  3168. vrcCompPtDriverFaultU06 TruthValue,
  3169. vrcCompPtDriverFaultU07 TruthValue,
  3170. vrcCompPtDriverFaultU08 TruthValue,
  3171. vrcCompPtDriverFaultU09 TruthValue,
  3172. vrcCompPtDriverFaultU10 TruthValue,
  3173. vrcCompPtDriverFaultU11 TruthValue,
  3174. vrcCompPtDriverFaultU12 TruthValue,
  3175. vrcCompPtDriverFaultU13 TruthValue,
  3176. vrcCompPtDriverFaultU14 TruthValue,
  3177. vrcCompPtDriverFaultU15 TruthValue,
  3178. vrcCompPtDriverCommFailAlarm TruthValue,
  3179. vrcCompPtFaultLockAlarm TruthValue
  3180. }
  3181.  
  3182. vrcCompPtIndex OBJECT-TYPE
  3183. SYNTAX Integer32(1..100)
  3184. MAX-ACCESS not-accessible
  3185. STATUS current
  3186. DESCRIPTION
  3187. "Unique id for each entry in the table"
  3188. ::= { vrcCompPtEntry 1 }
  3189.  
  3190. vrcCompPtName OBJECT-TYPE
  3191. SYNTAX SnmpAdminString(SIZE (1..25))
  3192. MAX-ACCESS read-only
  3193. STATUS current
  3194. DESCRIPTION
  3195. "Compressor name (factory-assigned)"
  3196. ::= { vrcCompPtEntry 2 }
  3197.  
  3198. vrcCompPtCapacity OBJECT-TYPE
  3199. SYNTAX Integer32(0..100)
  3200. UNITS "%"
  3201. MAX-ACCESS read-only
  3202. STATUS current
  3203. DESCRIPTION
  3204. "Compressor capacity value (percent)"
  3205. ::= { vrcCompPtEntry 3 }
  3206.  
  3207. vrcCompPtRunTimeHours OBJECT-TYPE
  3208. SYNTAX Integer32(-32768..32767)
  3209. UNITS "hours"
  3210. MAX-ACCESS read-only
  3211. STATUS current
  3212. DESCRIPTION
  3213. "Compressor run time in hours"
  3214. ::= { vrcCompPtEntry 4 }
  3215.  
  3216. vrcCompPtStartStopCount OBJECT-TYPE
  3217. SYNTAX Integer32(-32768..32767)
  3218. MAX-ACCESS read-only
  3219. STATUS current
  3220. DESCRIPTION
  3221. "Compressor start/stop count"
  3222. ::= { vrcCompPtEntry 5 }
  3223.  
  3224. vrcCompPtDriverFaultU00 OBJECT-TYPE
  3225. SYNTAX TruthValue
  3226. MAX-ACCESS read-only
  3227. STATUS current
  3228. DESCRIPTION
  3229. "Compressor driver fault alarm U00 state"
  3230. ::= { vrcCompPtEntry 6 }
  3231.  
  3232. vrcCompPtDriverFaultU01 OBJECT-TYPE
  3233. SYNTAX TruthValue
  3234. MAX-ACCESS read-only
  3235. STATUS current
  3236. DESCRIPTION
  3237. "Compressor driver fault alarm U01 state"
  3238. ::= { vrcCompPtEntry 7 }
  3239.  
  3240. vrcCompPtDriverFaultU02 OBJECT-TYPE
  3241. SYNTAX TruthValue
  3242. MAX-ACCESS read-only
  3243. STATUS current
  3244. DESCRIPTION
  3245. "Compressor driver fault alarm U02 state"
  3246. ::= { vrcCompPtEntry 8 }
  3247.  
  3248. vrcCompPtDriverFaultU03 OBJECT-TYPE
  3249. SYNTAX TruthValue
  3250. MAX-ACCESS read-only
  3251. STATUS current
  3252. DESCRIPTION
  3253. "Compressor driver fault alarm U03 state"
  3254. ::= { vrcCompPtEntry 9 }
  3255.  
  3256. vrcCompPtDriverFaultU04 OBJECT-TYPE
  3257. SYNTAX TruthValue
  3258. MAX-ACCESS read-only
  3259. STATUS current
  3260. DESCRIPTION
  3261. "Compressor driver fault alarm U04 state"
  3262. ::= { vrcCompPtEntry 10 }
  3263.  
  3264. vrcCompPtDriverFaultU05 OBJECT-TYPE
  3265. SYNTAX TruthValue
  3266. MAX-ACCESS read-only
  3267. STATUS current
  3268. DESCRIPTION
  3269. "Compressor driver fault alarm U05 state"
  3270. ::= { vrcCompPtEntry 11 }
  3271.  
  3272. vrcCompPtDriverFaultU06 OBJECT-TYPE
  3273. SYNTAX TruthValue
  3274. MAX-ACCESS read-only
  3275. STATUS current
  3276. DESCRIPTION
  3277. "Compressor driver fault alarm U06 state"
  3278. ::= { vrcCompPtEntry 12 }
  3279.  
  3280. vrcCompPtDriverFaultU07 OBJECT-TYPE
  3281. SYNTAX TruthValue
  3282. MAX-ACCESS read-only
  3283. STATUS current
  3284. DESCRIPTION
  3285. "Compressor driver fault alarm U07 state"
  3286. ::= { vrcCompPtEntry 13 }
  3287.  
  3288. vrcCompPtDriverFaultU08 OBJECT-TYPE
  3289. SYNTAX TruthValue
  3290. MAX-ACCESS read-only
  3291. STATUS current
  3292. DESCRIPTION
  3293. "Compressor driver fault alarm U08 state"
  3294. ::= { vrcCompPtEntry 14 }
  3295.  
  3296. vrcCompPtDriverFaultU09 OBJECT-TYPE
  3297. SYNTAX TruthValue
  3298. MAX-ACCESS read-only
  3299. STATUS current
  3300. DESCRIPTION
  3301. "Compressor driver fault alarm U09 state"
  3302. ::= { vrcCompPtEntry 15 }
  3303.  
  3304. vrcCompPtDriverFaultU10 OBJECT-TYPE
  3305. SYNTAX TruthValue
  3306. MAX-ACCESS read-only
  3307. STATUS current
  3308. DESCRIPTION
  3309. "Compressor driver fault alarm U10 state"
  3310. ::= { vrcCompPtEntry 16 }
  3311.  
  3312. vrcCompPtDriverFaultU11 OBJECT-TYPE
  3313. SYNTAX TruthValue
  3314. MAX-ACCESS read-only
  3315. STATUS current
  3316. DESCRIPTION
  3317. "Compressor driver fault alarm U11 state"
  3318. ::= { vrcCompPtEntry 17 }
  3319.  
  3320. vrcCompPtDriverFaultU12 OBJECT-TYPE
  3321. SYNTAX TruthValue
  3322. MAX-ACCESS read-only
  3323. STATUS current
  3324. DESCRIPTION
  3325. "Compressor driver fault alarm U12 state"
  3326. ::= { vrcCompPtEntry 18 }
  3327.  
  3328. vrcCompPtDriverFaultU13 OBJECT-TYPE
  3329. SYNTAX TruthValue
  3330. MAX-ACCESS read-only
  3331. STATUS current
  3332. DESCRIPTION
  3333. "Compressor driver fault alarm U13 state"
  3334. ::= { vrcCompPtEntry 19 }
  3335.  
  3336. vrcCompPtDriverFaultU14 OBJECT-TYPE
  3337. SYNTAX TruthValue
  3338. MAX-ACCESS read-only
  3339. STATUS current
  3340. DESCRIPTION
  3341. "Compressor driver fault alarm U14 state"
  3342. ::= { vrcCompPtEntry 20 }
  3343.  
  3344. vrcCompPtDriverFaultU15 OBJECT-TYPE
  3345. SYNTAX TruthValue
  3346. MAX-ACCESS read-only
  3347. STATUS current
  3348. DESCRIPTION
  3349. "Compressor driver fault alarm U15 state"
  3350. ::= { vrcCompPtEntry 21 }
  3351.  
  3352. vrcCompPtDriverCommFailAlarm OBJECT-TYPE
  3353. SYNTAX TruthValue
  3354. MAX-ACCESS read-only
  3355. STATUS current
  3356. DESCRIPTION
  3357. "Compressor driver communication failure alarm state"
  3358. ::= { vrcCompPtEntry 22 }
  3359.  
  3360. vrcCompPtFaultLockAlarm OBJECT-TYPE
  3361. SYNTAX TruthValue
  3362. MAX-ACCESS read-only
  3363. STATUS current
  3364. DESCRIPTION
  3365. "Compressor fault lock alarm state"
  3366. ::= { vrcCompPtEntry 23 }
  3367.  
  3368. --###########################################################################################--
  3369. --vrcCompCfgTable--
  3370. --###########################################################################################--
  3371.  
  3372. vrcCompCfgTable OBJECT-TYPE
  3373. SYNTAX SEQUENCE OF VrcCompCfgEntry
  3374. MAX-ACCESS not-accessible
  3375. STATUS current
  3376. DESCRIPTION
  3377. "Table used for VRC compressor configuration"
  3378. ::= { vrc 9 }
  3379.  
  3380. vrcCompCfgEntry OBJECT-TYPE
  3381. SYNTAX VrcCompCfgEntry
  3382. MAX-ACCESS not-accessible
  3383. STATUS current
  3384. DESCRIPTION
  3385. "Entry in the vrcCompCfgTable: each entry contains config fields for a
  3386. VRC compressor"
  3387. INDEX { vrcCompCfgIndex }
  3388. ::= { vrcCompCfgTable 1 }
  3389.  
  3390. VrcCompCfgEntry ::= SEQUENCE {
  3391. vrcCompCfgIndex Integer32,
  3392. vrcCompCfgOutputStatus TruthValue,
  3393. vrcCompCfgOutputDeadBand Integer32,
  3394. vrcCompCfgCapacityOutputValue Integer32,
  3395. vrcCompCfgMinCapacity Integer32,
  3396. vrcCompCfgStartCapacity Integer32,
  3397. vrcCompCfgStandardCapacity Integer32,
  3398. vrcCompCfgStartCfc Integer32,
  3399. vrcCompCfgStopCfc Integer32,
  3400. vrcCompCfgMinRunTime Integer32,
  3401. vrcCompCfgMinStopTime Integer32,
  3402. vrcCompCfgJumpBand1 Integer32,
  3403. vrcCompCfgJumpBand2 Integer32,
  3404. vrcCompCfgJumpBand3 Integer32,
  3405. vrcCompCfgJumpBand4 Integer32,
  3406. vrcCompCfgJumpBand5 Integer32,
  3407. vrcCompCfgJumpFreq1 Integer32,
  3408. vrcCompCfgJumpFreq2 Integer32,
  3409. vrcCompCfgJumpFreq3 Integer32,
  3410. vrcCompCfgJumpFreq4 Integer32,
  3411. vrcCompCfgJumpFreq5 Integer32,
  3412. vrcCompCfgTempP Integer32,
  3413. vrcCompCfgTempI Integer32,
  3414. vrcCompCfgTempD Integer32,
  3415. vrcCompCfgDriverFaultAlmCtrl INTEGER,
  3416. vrcCompCfgDriverCommFailAlmCtrl INTEGER,
  3417. vrcCompCfgFaultLockAlmCtrl INTEGER
  3418. }
  3419.  
  3420. vrcCompCfgIndex OBJECT-TYPE
  3421. SYNTAX Integer32(1..100)
  3422. MAX-ACCESS not-accessible
  3423. STATUS current
  3424. DESCRIPTION
  3425. "Unique id for each entry in the table"
  3426. ::= { vrcCompCfgEntry 1 }
  3427.  
  3428. vrcCompCfgOutputStatus OBJECT-TYPE
  3429. SYNTAX TruthValue
  3430. MAX-ACCESS read-write
  3431. STATUS current
  3432. DESCRIPTION
  3433. "Compressor output status"
  3434. ::= { vrcCompCfgEntry 2 }
  3435.  
  3436. vrcCompCfgOutputDeadBand OBJECT-TYPE
  3437. SYNTAX Integer32(0..50)
  3438. UNITS "0.1%"
  3439. MAX-ACCESS read-write
  3440. STATUS current
  3441. DESCRIPTION
  3442. "Compressor output dead band in tenths of a percent"
  3443. ::= { vrcCompCfgEntry 3 }
  3444.  
  3445. vrcCompCfgCapacityOutputValue OBJECT-TYPE
  3446. SYNTAX Integer32(0..100)
  3447. UNITS "%"
  3448. MAX-ACCESS read-write
  3449. STATUS current
  3450. DESCRIPTION
  3451. "Compressor capacity output (percent)"
  3452. ::= { vrcCompCfgEntry 4 }
  3453.  
  3454. vrcCompCfgMinCapacity OBJECT-TYPE
  3455. SYNTAX Integer32(15..50)
  3456. UNITS "%"
  3457. MAX-ACCESS read-write
  3458. STATUS current
  3459. DESCRIPTION
  3460. "Compressor min capacity (percent)"
  3461. ::= { vrcCompCfgEntry 5 }
  3462.  
  3463. vrcCompCfgStartCapacity OBJECT-TYPE
  3464. SYNTAX Integer32(40..100)
  3465. UNITS "%"
  3466. MAX-ACCESS read-write
  3467. STATUS current
  3468. DESCRIPTION
  3469. "Compressor start capacity (percent)"
  3470. ::= { vrcCompCfgEntry 6 }
  3471.  
  3472. vrcCompCfgStandardCapacity OBJECT-TYPE
  3473. SYNTAX Integer32(80..100)
  3474. UNITS "%"
  3475. MAX-ACCESS read-write
  3476. STATUS current
  3477. DESCRIPTION
  3478. "Compressor standard capacity (percent)"
  3479. ::= { vrcCompCfgEntry 7 }
  3480.  
  3481. vrcCompCfgStartCfc OBJECT-TYPE
  3482. SYNTAX Integer32(1..100)
  3483. UNITS "%"
  3484. MAX-ACCESS read-write
  3485. STATUS current
  3486. DESCRIPTION
  3487. "Compressor start cfc (percent)"
  3488. ::= { vrcCompCfgEntry 8 }
  3489.  
  3490. vrcCompCfgStopCfc OBJECT-TYPE
  3491. SYNTAX Integer32(-200..-50)
  3492. UNITS "%"
  3493. MAX-ACCESS read-write
  3494. STATUS current
  3495. DESCRIPTION
  3496. "Compressor stop cfc (percent)"
  3497. ::= { vrcCompCfgEntry 9 }
  3498.  
  3499. vrcCompCfgMinRunTime OBJECT-TYPE
  3500. SYNTAX Integer32(0..30)
  3501. UNITS "minutes"
  3502. MAX-ACCESS read-write
  3503. STATUS current
  3504. DESCRIPTION
  3505. "Compressor min run time in minutes"
  3506. ::= { vrcCompCfgEntry 10 }
  3507.  
  3508. vrcCompCfgMinStopTime OBJECT-TYPE
  3509. SYNTAX Integer32(0..10)
  3510. UNITS "minutes"
  3511. MAX-ACCESS read-write
  3512. STATUS current
  3513. DESCRIPTION
  3514. "Compressor min stop time in minutes"
  3515. ::= { vrcCompCfgEntry 11 }
  3516.  
  3517. vrcCompCfgJumpBand1 OBJECT-TYPE
  3518. SYNTAX Integer32(0..100)
  3519. UNITS "0.1%"
  3520. MAX-ACCESS read-write
  3521. STATUS current
  3522. DESCRIPTION
  3523. "Compressor jump band 1 in tenths of a percent"
  3524. ::= { vrcCompCfgEntry 12 }
  3525.  
  3526. vrcCompCfgJumpBand2 OBJECT-TYPE
  3527. SYNTAX Integer32(0..100)
  3528. UNITS "0.1%"
  3529. MAX-ACCESS read-write
  3530. STATUS current
  3531. DESCRIPTION
  3532. "Compressor jump band 2 in tenths of a percent"
  3533. ::= { vrcCompCfgEntry 13 }
  3534.  
  3535. vrcCompCfgJumpBand3 OBJECT-TYPE
  3536. SYNTAX Integer32(0..100)
  3537. UNITS "0.1%"
  3538. MAX-ACCESS read-write
  3539. STATUS current
  3540. DESCRIPTION
  3541. "Compressor jump band 3 in tenths of a percent"
  3542. ::= { vrcCompCfgEntry 14 }
  3543.  
  3544. vrcCompCfgJumpBand4 OBJECT-TYPE
  3545. SYNTAX Integer32(0..100)
  3546. UNITS "0.1%"
  3547. MAX-ACCESS read-write
  3548. STATUS current
  3549. DESCRIPTION
  3550. "Compressor jump band 4 in tenths of a percent"
  3551. ::= { vrcCompCfgEntry 15 }
  3552.  
  3553. vrcCompCfgJumpBand5 OBJECT-TYPE
  3554. SYNTAX Integer32(0..100)
  3555. UNITS "0.1%"
  3556. MAX-ACCESS read-write
  3557. STATUS current
  3558. DESCRIPTION
  3559. "Compressor jump band 5 in tenths of a percent"
  3560. ::= { vrcCompCfgEntry 16 }
  3561.  
  3562. vrcCompCfgJumpFreq1 OBJECT-TYPE
  3563. SYNTAX Integer32(0..1000)
  3564. UNITS "0.1%"
  3565. MAX-ACCESS read-write
  3566. STATUS current
  3567. DESCRIPTION
  3568. "Compressor jump frequency 1 in tenths of a percent"
  3569. ::= { vrcCompCfgEntry 17 }
  3570.  
  3571. vrcCompCfgJumpFreq2 OBJECT-TYPE
  3572. SYNTAX Integer32(0..1000)
  3573. UNITS "0.1%"
  3574. MAX-ACCESS read-write
  3575. STATUS current
  3576. DESCRIPTION
  3577. "Compressor jump frequency 2 in tenths of a percent"
  3578. ::= { vrcCompCfgEntry 18 }
  3579.  
  3580. vrcCompCfgJumpFreq3 OBJECT-TYPE
  3581. SYNTAX Integer32(0..1000)
  3582. UNITS "0.1%"
  3583. MAX-ACCESS read-write
  3584. STATUS current
  3585. DESCRIPTION
  3586. "Compressor jump frequency 3 in tenths of a percent"
  3587. ::= { vrcCompCfgEntry 19 }
  3588.  
  3589. vrcCompCfgJumpFreq4 OBJECT-TYPE
  3590. SYNTAX Integer32(0..1000)
  3591. UNITS "0.1%"
  3592. MAX-ACCESS read-write
  3593. STATUS current
  3594. DESCRIPTION
  3595. "Compressor jump frequency 4 in tenths of a percent"
  3596. ::= { vrcCompCfgEntry 20 }
  3597.  
  3598. vrcCompCfgJumpFreq5 OBJECT-TYPE
  3599. SYNTAX Integer32(0..1000)
  3600. UNITS "0.1%"
  3601. MAX-ACCESS read-write
  3602. STATUS current
  3603. DESCRIPTION
  3604. "Compressor jump frequency 5 in tenths of a percent"
  3605. ::= { vrcCompCfgEntry 21 }
  3606.  
  3607. vrcCompCfgTempP OBJECT-TYPE
  3608. SYNTAX Integer32
  3609. UNITS "decidegrees"
  3610. MAX-ACCESS read-write
  3611. STATUS current
  3612. DESCRIPTION
  3613. "Compressor temperature P in tenths of a degree. Units are given by
  3614. temperatureUnits field in deviceInfo. The settable range is determined
  3615. by the current temperature units.
  3616. Celsius: 10 to 150
  3617. Fahrenheit: 18 to 269"
  3618. ::= { vrcCompCfgEntry 22 }
  3619.  
  3620. vrcCompCfgTempI OBJECT-TYPE
  3621. SYNTAX Integer32(0..900)
  3622. UNITS "seconds"
  3623. MAX-ACCESS read-write
  3624. STATUS current
  3625. DESCRIPTION
  3626. "Compressor temperature I in seconds"
  3627. ::= { vrcCompCfgEntry 23 }
  3628.  
  3629. vrcCompCfgTempD OBJECT-TYPE
  3630. SYNTAX Integer32(0..900)
  3631. UNITS "seconds"
  3632. MAX-ACCESS read-write
  3633. STATUS current
  3634. DESCRIPTION
  3635. "Compressor temperature D in seconds"
  3636. ::= { vrcCompCfgEntry 24 }
  3637.  
  3638. vrcCompCfgDriverFaultAlmCtrl OBJECT-TYPE
  3639. SYNTAX INTEGER {
  3640. suspend(2),
  3641. open(3)
  3642. }
  3643. MAX-ACCESS read-write
  3644. STATUS current
  3645. DESCRIPTION
  3646. "Compressor driver fault alarm control:
  3647. 2 = suspend
  3648. 3 = open"
  3649. ::= { vrcCompCfgEntry 25 }
  3650.  
  3651. vrcCompCfgDriverCommFailAlmCtrl OBJECT-TYPE
  3652. SYNTAX INTEGER {
  3653. suspend(2),
  3654. open(3)
  3655. }
  3656. MAX-ACCESS read-write
  3657. STATUS current
  3658. DESCRIPTION
  3659. "Compressor driver communication failure alarm control:
  3660. 2 = suspend
  3661. 3 = open"
  3662. ::= { vrcCompCfgEntry 26 }
  3663.  
  3664. vrcCompCfgFaultLockAlmCtrl OBJECT-TYPE
  3665. SYNTAX INTEGER {
  3666. suspend(2),
  3667. open(3)
  3668. }
  3669. MAX-ACCESS read-write
  3670. STATUS current
  3671. DESCRIPTION
  3672. "Compressor fault lock alarm control:
  3673. 2 = suspend
  3674. 3 = open"
  3675. ::= { vrcCompCfgEntry 27 }
  3676.  
  3677. --###########################################################################################--
  3678. --vrcReturnPtTable--
  3679. --###########################################################################################--
  3680.  
  3681. vrcReturnPtTable OBJECT-TYPE
  3682. SYNTAX SEQUENCE OF VrcReturnPtEntry
  3683. MAX-ACCESS not-accessible
  3684. STATUS current
  3685. DESCRIPTION
  3686. "Table that contains VRC return status"
  3687. ::= { vrc 10 }
  3688.  
  3689. vrcReturnPtEntry OBJECT-TYPE
  3690. SYNTAX VrcReturnPtEntry
  3691. MAX-ACCESS not-accessible
  3692. STATUS current
  3693. DESCRIPTION
  3694. "Entry in the vrcReturnPtTable: each entry represents return data for a
  3695. VRC"
  3696. INDEX { vrcReturnPtIndex }
  3697. ::= { vrcReturnPtTable 1 }
  3698.  
  3699. VrcReturnPtEntry ::= SEQUENCE {
  3700. vrcReturnPtIndex Integer32,
  3701. vrcReturnPtName SnmpAdminString,
  3702. vrcReturnPtTemp Integer32,
  3703. vrcReturnPtHighTempAlarm TruthValue,
  3704. vrcReturnPtTempSensorFailAlarm TruthValue
  3705. }
  3706.  
  3707. vrcReturnPtIndex OBJECT-TYPE
  3708. SYNTAX Integer32(1..100)
  3709. MAX-ACCESS not-accessible
  3710. STATUS current
  3711. DESCRIPTION
  3712. "Unique id for each entry in the table"
  3713. ::= { vrcReturnPtEntry 1 }
  3714.  
  3715. vrcReturnPtName OBJECT-TYPE
  3716. SYNTAX SnmpAdminString(SIZE (1..25))
  3717. MAX-ACCESS read-only
  3718. STATUS current
  3719. DESCRIPTION
  3720. "Return name (factory-assigned)"
  3721. ::= { vrcReturnPtEntry 2 }
  3722.  
  3723. vrcReturnPtTemp OBJECT-TYPE
  3724. SYNTAX Integer32
  3725. UNITS "decidegrees"
  3726. MAX-ACCESS read-only
  3727. STATUS current
  3728. DESCRIPTION
  3729. "Return temperature value in tenths of a degree. Units are given by
  3730. temperatureUnits field in deviceInfo. The range is determined by the
  3731. current temperature units.
  3732. Celsius: -400 to 1000
  3733. Fahrenheit: -400 to 2120"
  3734. ::= { vrcReturnPtEntry 3 }
  3735.  
  3736. vrcReturnPtHighTempAlarm OBJECT-TYPE
  3737. SYNTAX TruthValue
  3738. MAX-ACCESS read-only
  3739. STATUS current
  3740. DESCRIPTION
  3741. "Return high temperature alarm state"
  3742. ::= { vrcReturnPtEntry 4 }
  3743.  
  3744. vrcReturnPtTempSensorFailAlarm OBJECT-TYPE
  3745. SYNTAX TruthValue
  3746. MAX-ACCESS read-only
  3747. STATUS current
  3748. DESCRIPTION
  3749. "Return temperature sensor failure alarm state"
  3750. ::= { vrcReturnPtEntry 5 }
  3751.  
  3752. --###########################################################################################--
  3753. --vrcReturnCfgTable--
  3754. --###########################################################################################--
  3755.  
  3756. vrcReturnCfgTable OBJECT-TYPE
  3757. SYNTAX SEQUENCE OF VrcReturnCfgEntry
  3758. MAX-ACCESS not-accessible
  3759. STATUS current
  3760. DESCRIPTION
  3761. "Table used for VRC return configuration"
  3762. ::= { vrc 11 }
  3763.  
  3764. vrcReturnCfgEntry OBJECT-TYPE
  3765. SYNTAX VrcReturnCfgEntry
  3766. MAX-ACCESS not-accessible
  3767. STATUS current
  3768. DESCRIPTION
  3769. "Entry in the vrcReturnCfgTable: each entry contains config fields for
  3770. VRC return"
  3771. INDEX { vrcReturnCfgIndex }
  3772. ::= { vrcReturnCfgTable 1 }
  3773.  
  3774. VrcReturnCfgEntry ::= SEQUENCE {
  3775. vrcReturnCfgIndex Integer32,
  3776. vrcReturnCfgOilCycle Integer32,
  3777. vrcReturnCfgOilRunCapacity Integer32,
  3778. vrcReturnCfgOilRunTime Integer32,
  3779. vrcReturnCfgTempCalValue Integer32,
  3780. vrcReturnCfgTempSetting Integer32,
  3781. vrcReturnCfgHighTempAlarmValue Integer32,
  3782. vrcReturnCfgHighTempAlarmCtrl INTEGER,
  3783. vrcReturnCfgTempSensFailAlmCtrl INTEGER
  3784. }
  3785.  
  3786. vrcReturnCfgIndex OBJECT-TYPE
  3787. SYNTAX Integer32(1..100)
  3788. MAX-ACCESS not-accessible
  3789. STATUS current
  3790. DESCRIPTION
  3791. "Unique id for each entry in the table"
  3792. ::= { vrcReturnCfgEntry 1 }
  3793.  
  3794. vrcReturnCfgOilCycle OBJECT-TYPE
  3795. SYNTAX Integer32(5..50)
  3796. UNITS "decihours"
  3797. MAX-ACCESS read-write
  3798. STATUS current
  3799. DESCRIPTION
  3800. "Return oil cycle in tenths of an hour"
  3801. ::= { vrcReturnCfgEntry 2 }
  3802.  
  3803. vrcReturnCfgOilRunCapacity OBJECT-TYPE
  3804. SYNTAX Integer32(50..100)
  3805. UNITS "%"
  3806. MAX-ACCESS read-write
  3807. STATUS current
  3808. DESCRIPTION
  3809. "Return Oil run capacity (percent)"
  3810. ::= { vrcReturnCfgEntry 3 }
  3811.  
  3812. vrcReturnCfgOilRunTime OBJECT-TYPE
  3813. SYNTAX Integer32(0..10)
  3814. UNITS "minutes"
  3815. MAX-ACCESS read-write
  3816. STATUS current
  3817. DESCRIPTION
  3818. "Return oil run time in minutes"
  3819. ::= { vrcReturnCfgEntry 4 }
  3820.  
  3821. vrcReturnCfgTempCalValue OBJECT-TYPE
  3822. SYNTAX Integer32
  3823. UNITS "decidegrees"
  3824. MAX-ACCESS read-write
  3825. STATUS current
  3826. DESCRIPTION
  3827. "Return temperature calibration value in tenths of a degree. Units are
  3828. given by temperatureUnits field in deviceInfo. The settable range is
  3829. determined by the current temperature units.
  3830. Celsius: -100 to 100
  3831. Fahrenheit: -179 to 179"
  3832. ::= { vrcReturnCfgEntry 5 }
  3833.  
  3834. vrcReturnCfgTempSetting OBJECT-TYPE
  3835. SYNTAX Integer32
  3836. UNITS "decidegrees"
  3837. MAX-ACCESS read-write
  3838. STATUS current
  3839. DESCRIPTION
  3840. "Return temperature setting in tenths of a degree. Units are given by
  3841. temperatureUnits field in deviceInfo. The settable range is determined
  3842. by the current temperature units.
  3843. Celsius: 250 to 350
  3844. Fahrenheit: 770 to 949"
  3845. ::= { vrcReturnCfgEntry 6 }
  3846.  
  3847. vrcReturnCfgHighTempAlarmValue OBJECT-TYPE
  3848. SYNTAX Integer32
  3849. UNITS "decidegrees"
  3850. MAX-ACCESS read-write
  3851. STATUS current
  3852. DESCRIPTION
  3853. "Return high temperature alarm value in tenths of a degree. Units are
  3854. given by temperatureUnits field in deviceInfo. The settable range is
  3855. determined by the current temperature units.
  3856. Celsius: 300 to 450
  3857. Fahrenheit: 860 to 1129"
  3858. ::= { vrcReturnCfgEntry 7 }
  3859.  
  3860. vrcReturnCfgHighTempAlarmCtrl OBJECT-TYPE
  3861. SYNTAX INTEGER {
  3862. close(1),
  3863. suspend(2),
  3864. open(3)
  3865. }
  3866. MAX-ACCESS read-write
  3867. STATUS current
  3868. DESCRIPTION
  3869. "Return high temperature alarm control:
  3870. 1 = close
  3871. 2 = suspend
  3872. 3 = open"
  3873. ::= { vrcReturnCfgEntry 8 }
  3874.  
  3875. vrcReturnCfgTempSensFailAlmCtrl OBJECT-TYPE
  3876. SYNTAX INTEGER {
  3877. close(1),
  3878. suspend(2),
  3879. open(3)
  3880. }
  3881. MAX-ACCESS read-write
  3882. STATUS current
  3883. DESCRIPTION
  3884. "Return temperature sensor failure alarm control:
  3885. 1 = close
  3886. 2 = suspend
  3887. 3 = open"
  3888. ::= { vrcReturnCfgEntry 9 }
  3889.  
  3890. --###########################################################################################--
  3891. --vrcSupplyPtTable--
  3892. --###########################################################################################--
  3893.  
  3894. vrcSupplyPtTable OBJECT-TYPE
  3895. SYNTAX SEQUENCE OF VrcSupplyPtEntry
  3896. MAX-ACCESS not-accessible
  3897. STATUS current
  3898. DESCRIPTION
  3899. "Table that contains VRC supply status"
  3900. ::= { vrc 12 }
  3901.  
  3902. vrcSupplyPtEntry OBJECT-TYPE
  3903. SYNTAX VrcSupplyPtEntry
  3904. MAX-ACCESS not-accessible
  3905. STATUS current
  3906. DESCRIPTION
  3907. "Entry in the vrcSupplyPtTable: each entry represents supply data for a
  3908. VRC"
  3909. INDEX { vrcSupplyPtIndex }
  3910. ::= { vrcSupplyPtTable 1 }
  3911.  
  3912. VrcSupplyPtEntry ::= SEQUENCE {
  3913. vrcSupplyPtIndex Integer32,
  3914. vrcSupplyPtName SnmpAdminString,
  3915. vrcSupplyPtTemp Integer32,
  3916. vrcSupplyPtLowTempAlarm TruthValue,
  3917. vrcSupplyPtHighTempAlarm TruthValue,
  3918. vrcSupplyPtTempSensorFailAlarm TruthValue
  3919. }
  3920.  
  3921. vrcSupplyPtIndex OBJECT-TYPE
  3922. SYNTAX Integer32(1..100)
  3923. MAX-ACCESS not-accessible
  3924. STATUS current
  3925. DESCRIPTION
  3926. "Unique id for each entry in the table"
  3927. ::= { vrcSupplyPtEntry 1 }
  3928.  
  3929. vrcSupplyPtName OBJECT-TYPE
  3930. SYNTAX SnmpAdminString(SIZE (1..25))
  3931. MAX-ACCESS read-only
  3932. STATUS current
  3933. DESCRIPTION
  3934. "Supply name (factory-assigned)"
  3935. ::= { vrcSupplyPtEntry 2 }
  3936.  
  3937. vrcSupplyPtTemp OBJECT-TYPE
  3938. SYNTAX Integer32
  3939. UNITS "decidegrees"
  3940. MAX-ACCESS read-only
  3941. STATUS current
  3942. DESCRIPTION
  3943. "Supply temperature value in tenths of a degree. Units are given by
  3944. temperatureUnits field in deviceInfo. The range is determined by the
  3945. current temperature units.
  3946. Celsius: -400 to 1000
  3947. Fahrenheit: -400 to 2120"
  3948. ::= { vrcSupplyPtEntry 3 }
  3949.  
  3950. vrcSupplyPtLowTempAlarm OBJECT-TYPE
  3951. SYNTAX TruthValue
  3952. MAX-ACCESS read-only
  3953. STATUS current
  3954. DESCRIPTION
  3955. "Supply low temperature alarm state"
  3956. ::= { vrcSupplyPtEntry 4 }
  3957.  
  3958. vrcSupplyPtHighTempAlarm OBJECT-TYPE
  3959. SYNTAX TruthValue
  3960. MAX-ACCESS read-only
  3961. STATUS current
  3962. DESCRIPTION
  3963. "Supply high temperature alarm state"
  3964. ::= { vrcSupplyPtEntry 5 }
  3965.  
  3966. vrcSupplyPtTempSensorFailAlarm OBJECT-TYPE
  3967. SYNTAX TruthValue
  3968. MAX-ACCESS read-only
  3969. STATUS current
  3970. DESCRIPTION
  3971. "Supply temperature sensor failure alarm state"
  3972. ::= { vrcSupplyPtEntry 6 }
  3973.  
  3974. --###########################################################################################--
  3975. --vrcSupplyCfgTable--
  3976. --###########################################################################################--
  3977.  
  3978. vrcSupplyCfgTable OBJECT-TYPE
  3979. SYNTAX SEQUENCE OF VrcSupplyCfgEntry
  3980. MAX-ACCESS not-accessible
  3981. STATUS current
  3982. DESCRIPTION
  3983. "Table used for VRC supply configuration"
  3984. ::= { vrc 13 }
  3985.  
  3986. vrcSupplyCfgEntry OBJECT-TYPE
  3987. SYNTAX VrcSupplyCfgEntry
  3988. MAX-ACCESS not-accessible
  3989. STATUS current
  3990. DESCRIPTION
  3991. "Entry in the vrcSupplyCfgTable: each entry contains config fields for
  3992. a VRC supply"
  3993. INDEX { vrcSupplyCfgIndex }
  3994. ::= { vrcSupplyCfgTable 1 }
  3995.  
  3996. VrcSupplyCfgEntry ::= SEQUENCE {
  3997. vrcSupplyCfgIndex Integer32,
  3998. vrcSupplyCfgTempCalValue Integer32,
  3999. vrcSupplyCfgTempSetting Integer32,
  4000. vrcSupplyCfgLowTempAlarmValue Integer32,
  4001. vrcSupplyCfgHighTempAlarmValue Integer32,
  4002. vrcSupplyCfgLowTempAlmCtrl INTEGER,
  4003. vrcSupplyCfgHighTempAlmCtrl INTEGER,
  4004. vrcSupplyCfgTempSensFailAlmCtrl INTEGER
  4005. }
  4006.  
  4007. vrcSupplyCfgIndex OBJECT-TYPE
  4008. SYNTAX Integer32(1..100)
  4009. MAX-ACCESS not-accessible
  4010. STATUS current
  4011. DESCRIPTION
  4012. "Unique id for each entry in the table"
  4013. ::= { vrcSupplyCfgEntry 1 }
  4014.  
  4015. vrcSupplyCfgTempCalValue OBJECT-TYPE
  4016. SYNTAX Integer32
  4017. UNITS "decidegrees"
  4018. MAX-ACCESS read-write
  4019. STATUS current
  4020. DESCRIPTION
  4021. "Supply temperature calibration value in tenths of a degree. Units are
  4022. given by temperatureUnits field in deviceInfo. The settable range is
  4023. determined by the current temperature units.
  4024. Celsius: -100 to 100
  4025. Fahrenheit: -179 to 179"
  4026. ::= { vrcSupplyCfgEntry 2 }
  4027.  
  4028. vrcSupplyCfgTempSetting OBJECT-TYPE
  4029. SYNTAX Integer32
  4030. UNITS "decidegrees"
  4031. MAX-ACCESS read-write
  4032. STATUS current
  4033. DESCRIPTION
  4034. "Supply temperature setting in tenths of a degree. Units are given by
  4035. temperatureUnits field in deviceInfo. The settable range is determined
  4036. by the current temperature units.
  4037. Celsius: 130 to 280
  4038. Fahrenheit: 554 to 823"
  4039. ::= { vrcSupplyCfgEntry 3 }
  4040.  
  4041. vrcSupplyCfgLowTempAlarmValue OBJECT-TYPE
  4042. SYNTAX Integer32
  4043. UNITS "decidegrees"
  4044. MAX-ACCESS read-write
  4045. STATUS current
  4046. DESCRIPTION
  4047. "Supply low temperature alarm value in tenths of a degree. Units are
  4048. given by temperatureUnits field in deviceInfo. The settable range is
  4049. determined by the current temperature units.
  4050. Celsius: 50 to 200
  4051. Fahrenheit: 410 to 679"
  4052. ::= { vrcSupplyCfgEntry 4 }
  4053.  
  4054. vrcSupplyCfgHighTempAlarmValue OBJECT-TYPE
  4055. SYNTAX Integer32
  4056. UNITS "decidegrees"
  4057. MAX-ACCESS read-write
  4058. STATUS current
  4059. DESCRIPTION
  4060. "Supply high temperature alarm value in tenths of a degree. Units are
  4061. given by temperatureUnits field in deviceInfo. The settable range is
  4062. determined by the current temperature units.
  4063. Celsius: 200 to 350
  4064. Fahrenheit: 680 to 949"
  4065. ::= { vrcSupplyCfgEntry 5 }
  4066.  
  4067. vrcSupplyCfgLowTempAlmCtrl OBJECT-TYPE
  4068. SYNTAX INTEGER {
  4069. close(1),
  4070. suspend(2),
  4071. open(3)
  4072. }
  4073. MAX-ACCESS read-write
  4074. STATUS current
  4075. DESCRIPTION
  4076. "Supply low temperature alarm control:
  4077. 1 = close
  4078. 2 = suspend
  4079. 3 = open"
  4080. ::= { vrcSupplyCfgEntry 6 }
  4081.  
  4082. vrcSupplyCfgHighTempAlmCtrl OBJECT-TYPE
  4083. SYNTAX INTEGER {
  4084. close(1),
  4085. suspend(2),
  4086. open(3)
  4087. }
  4088. MAX-ACCESS read-write
  4089. STATUS current
  4090. DESCRIPTION
  4091. "Supply high temperature alarm control:
  4092. 1 = close
  4093. 2 = suspend
  4094. 3 = open"
  4095. ::= { vrcSupplyCfgEntry 7 }
  4096.  
  4097. vrcSupplyCfgTempSensFailAlmCtrl OBJECT-TYPE
  4098. SYNTAX INTEGER {
  4099. close(1),
  4100. suspend(2),
  4101. open(3)
  4102. }
  4103. MAX-ACCESS read-write
  4104. STATUS current
  4105. DESCRIPTION
  4106. "Supply temperature sensor failure alarm control:
  4107. 1 = close
  4108. 2 = suspend
  4109. 3 = open"
  4110. ::= { vrcSupplyCfgEntry 8 }
  4111.  
  4112. --###########################################################################################--
  4113. --vrcPowerPtTable--
  4114. --###########################################################################################--
  4115.  
  4116. vrcPowerPtTable OBJECT-TYPE
  4117. SYNTAX SEQUENCE OF VrcPowerPtEntry
  4118. MAX-ACCESS not-accessible
  4119. STATUS current
  4120. DESCRIPTION
  4121. "Table that contains VRC power status"
  4122. ::= { vrc 14 }
  4123.  
  4124. vrcPowerPtEntry OBJECT-TYPE
  4125. SYNTAX VrcPowerPtEntry
  4126. MAX-ACCESS not-accessible
  4127. STATUS current
  4128. DESCRIPTION
  4129. "Entry in the vrcPowerPtTable: each entry represents power data for a
  4130. VRC"
  4131. INDEX { vrcPowerPtIndex }
  4132. ::= { vrcPowerPtTable 1 }
  4133.  
  4134. VrcPowerPtEntry ::= SEQUENCE {
  4135. vrcPowerPtIndex Integer32,
  4136. vrcPowerPtName SnmpAdminString,
  4137. vrcPowerPtVoltage Integer32,
  4138. vrcPowerPtFrequency Integer32,
  4139. vrcPowerPtLowVoltageAlarm TruthValue,
  4140. vrcPowerPtHighVoltageAlarm TruthValue,
  4141. vrcPowerPtLossOfPhasePowerAlarm TruthValue,
  4142. vrcPowerPtLossOfPowerAlarm TruthValue,
  4143. vrcPowerPtFrequencyErrorAlarm TruthValue
  4144. }
  4145.  
  4146. vrcPowerPtIndex OBJECT-TYPE
  4147. SYNTAX Integer32(1..100)
  4148. MAX-ACCESS not-accessible
  4149. STATUS current
  4150. DESCRIPTION
  4151. "Unique id for each entry in the table"
  4152. ::= { vrcPowerPtEntry 1 }
  4153.  
  4154. vrcPowerPtName OBJECT-TYPE
  4155. SYNTAX SnmpAdminString(SIZE (1..25))
  4156. MAX-ACCESS read-only
  4157. STATUS current
  4158. DESCRIPTION
  4159. "Power name (factory-assigned)"
  4160. ::= { vrcPowerPtEntry 2 }
  4161.  
  4162. vrcPowerPtVoltage OBJECT-TYPE
  4163. SYNTAX Integer32(-32768..32767)
  4164. UNITS "decivolts"
  4165. MAX-ACCESS read-only
  4166. STATUS current
  4167. DESCRIPTION
  4168. "Power voltage measurement in tenths of a volt"
  4169. ::= { vrcPowerPtEntry 3 }
  4170.  
  4171. vrcPowerPtFrequency OBJECT-TYPE
  4172. SYNTAX Integer32(-32768..32767)
  4173. UNITS "decihertz"
  4174. MAX-ACCESS read-only
  4175. STATUS current
  4176. DESCRIPTION
  4177. "Power frequency measurement in tenths of hertz"
  4178. ::= { vrcPowerPtEntry 4 }
  4179.  
  4180. vrcPowerPtLowVoltageAlarm OBJECT-TYPE
  4181. SYNTAX TruthValue
  4182. MAX-ACCESS read-only
  4183. STATUS current
  4184. DESCRIPTION
  4185. "Power low voltage alarm state"
  4186. ::= { vrcPowerPtEntry 5 }
  4187.  
  4188. vrcPowerPtHighVoltageAlarm OBJECT-TYPE
  4189. SYNTAX TruthValue
  4190. MAX-ACCESS read-only
  4191. STATUS current
  4192. DESCRIPTION
  4193. "Power high voltage alarm state"
  4194. ::= { vrcPowerPtEntry 6 }
  4195.  
  4196. vrcPowerPtLossOfPhasePowerAlarm OBJECT-TYPE
  4197. SYNTAX TruthValue
  4198. MAX-ACCESS read-only
  4199. STATUS current
  4200. DESCRIPTION
  4201. "Phase power loss alarm state"
  4202. ::= { vrcPowerPtEntry 7 }
  4203.  
  4204. vrcPowerPtLossOfPowerAlarm OBJECT-TYPE
  4205. SYNTAX TruthValue
  4206. MAX-ACCESS read-only
  4207. STATUS current
  4208. DESCRIPTION
  4209. "Power loss alarm state"
  4210. ::= { vrcPowerPtEntry 8 }
  4211.  
  4212. vrcPowerPtFrequencyErrorAlarm OBJECT-TYPE
  4213. SYNTAX TruthValue
  4214. MAX-ACCESS read-only
  4215. STATUS current
  4216. DESCRIPTION
  4217. "Power frequency error alarm state"
  4218. ::= { vrcPowerPtEntry 9 }
  4219.  
  4220. --###########################################################################################--
  4221. --vrcPowerCfgTable--
  4222. --###########################################################################################--
  4223.  
  4224. vrcPowerCfgTable OBJECT-TYPE
  4225. SYNTAX SEQUENCE OF VrcPowerCfgEntry
  4226. MAX-ACCESS not-accessible
  4227. STATUS current
  4228. DESCRIPTION
  4229. "Table used for VRC power configuration"
  4230. ::= { vrc 15 }
  4231.  
  4232. vrcPowerCfgEntry OBJECT-TYPE
  4233. SYNTAX VrcPowerCfgEntry
  4234. MAX-ACCESS not-accessible
  4235. STATUS current
  4236. DESCRIPTION
  4237. "Entry in the vrcPowerCfgTable: each entry contains config fields for
  4238. VRC power"
  4239. INDEX { vrcPowerCfgIndex }
  4240. ::= { vrcPowerCfgTable 1 }
  4241.  
  4242. VrcPowerCfgEntry ::= SEQUENCE {
  4243. vrcPowerCfgIndex Integer32,
  4244. vrcPowerCfgLowVoltageSetting Integer32,
  4245. vrcPowerCfgHighVoltageSetting Integer32,
  4246. vrcPowerCfgLowVoltageAlarmCtrl INTEGER,
  4247. vrcPowerCfgHighVoltageAlarmCtrl INTEGER,
  4248. vrcPowerCfgLossOfPowerAlarmCtrl INTEGER,
  4249. vrcPowerCfgFreqErrorAlarmCtrl INTEGER
  4250. }
  4251.  
  4252. vrcPowerCfgIndex OBJECT-TYPE
  4253. SYNTAX Integer32(1..100)
  4254. MAX-ACCESS not-accessible
  4255. STATUS current
  4256. DESCRIPTION
  4257. "Unique id for each entry in the table"
  4258. ::= { vrcPowerCfgEntry 1 }
  4259.  
  4260. vrcPowerCfgLowVoltageSetting OBJECT-TYPE
  4261. SYNTAX Integer32(100..230)
  4262. UNITS "volts"
  4263. MAX-ACCESS read-write
  4264. STATUS current
  4265. DESCRIPTION
  4266. "Power low voltage setting in volts"
  4267. ::= { vrcPowerCfgEntry 2 }
  4268.  
  4269. vrcPowerCfgHighVoltageSetting OBJECT-TYPE
  4270. SYNTAX Integer32(100..300)
  4271. UNITS "volts"
  4272. MAX-ACCESS read-write
  4273. STATUS current
  4274. DESCRIPTION
  4275. "Power high voltage setting in volts"
  4276. ::= { vrcPowerCfgEntry 3 }
  4277.  
  4278. vrcPowerCfgLowVoltageAlarmCtrl OBJECT-TYPE
  4279. SYNTAX INTEGER {
  4280. close(1),
  4281. suspend(2),
  4282. open(3)
  4283. }
  4284. MAX-ACCESS read-write
  4285. STATUS current
  4286. DESCRIPTION
  4287. "Power low voltage alarm control:
  4288. 1 = close
  4289. 2 = suspend
  4290. 3 = open"
  4291. ::= { vrcPowerCfgEntry 4 }
  4292.  
  4293. vrcPowerCfgHighVoltageAlarmCtrl OBJECT-TYPE
  4294. SYNTAX INTEGER {
  4295. close(1),
  4296. suspend(2),
  4297. open(3)
  4298. }
  4299. MAX-ACCESS read-write
  4300. STATUS current
  4301. DESCRIPTION
  4302. "Power high voltage alarm control:
  4303. 1 = close
  4304. 2 = suspend
  4305. 3 = open"
  4306. ::= { vrcPowerCfgEntry 5 }
  4307.  
  4308. vrcPowerCfgLossOfPowerAlarmCtrl OBJECT-TYPE
  4309. SYNTAX INTEGER {
  4310. close(1),
  4311. suspend(2),
  4312. open(3)
  4313. }
  4314. MAX-ACCESS read-write
  4315. STATUS current
  4316. DESCRIPTION
  4317. "Power loss alarm control:
  4318. 1 = close
  4319. 2 = suspend
  4320. 3 = open"
  4321. ::= { vrcPowerCfgEntry 6 }
  4322.  
  4323. vrcPowerCfgFreqErrorAlarmCtrl OBJECT-TYPE
  4324. SYNTAX INTEGER {
  4325. close(1),
  4326. suspend(2),
  4327. open(3)
  4328. }
  4329. MAX-ACCESS read-write
  4330. STATUS current
  4331. DESCRIPTION
  4332. "Power frequency error alarm control:
  4333. 1 = close
  4334. 2 = suspend
  4335. 3 = open"
  4336. ::= { vrcPowerCfgEntry 7 }
  4337.  
  4338. --###########################################################################################--
  4339. --vrcOutdoorPtTable--
  4340. --###########################################################################################--
  4341.  
  4342. vrcOutdoorPtTable OBJECT-TYPE
  4343. SYNTAX SEQUENCE OF VrcOutdoorPtEntry
  4344. MAX-ACCESS not-accessible
  4345. STATUS current
  4346. DESCRIPTION
  4347. "Table that contains VRC outdoor status"
  4348. ::= { vrc 16 }
  4349.  
  4350. vrcOutdoorPtEntry OBJECT-TYPE
  4351. SYNTAX VrcOutdoorPtEntry
  4352. MAX-ACCESS not-accessible
  4353. STATUS current
  4354. DESCRIPTION
  4355. "Entry in the vrcOutdoorPtTable: each entry represents data for a VRC
  4356. outdoor"
  4357. INDEX { vrcOutdoorPtIndex }
  4358. ::= { vrcOutdoorPtTable 1 }
  4359.  
  4360. VrcOutdoorPtEntry ::= SEQUENCE {
  4361. vrcOutdoorPtIndex Integer32,
  4362. vrcOutdoorPtName SnmpAdminString,
  4363. vrcOutdoorPtTemp Integer32
  4364. }
  4365.  
  4366. vrcOutdoorPtIndex OBJECT-TYPE
  4367. SYNTAX Integer32(1..100)
  4368. MAX-ACCESS not-accessible
  4369. STATUS current
  4370. DESCRIPTION
  4371. "Unique id for each entry in the table"
  4372. ::= { vrcOutdoorPtEntry 1 }
  4373.  
  4374. vrcOutdoorPtName OBJECT-TYPE
  4375. SYNTAX SnmpAdminString(SIZE (1..25))
  4376. MAX-ACCESS read-only
  4377. STATUS current
  4378. DESCRIPTION
  4379. "Outdoor name (factory-assigned)"
  4380. ::= { vrcOutdoorPtEntry 2 }
  4381.  
  4382. vrcOutdoorPtTemp OBJECT-TYPE
  4383. SYNTAX Integer32
  4384. UNITS "decidegrees"
  4385. MAX-ACCESS read-only
  4386. STATUS current
  4387. DESCRIPTION
  4388. "Outdoor temperature value in tenths of a degree. Units are given by
  4389. temperatureUnits field in deviceInfo. The range is determined by the
  4390. current temperature units.
  4391. Celsius: -400 to 1000
  4392. Fahrenheit: -400 to 2120"
  4393. ::= { vrcOutdoorPtEntry 3 }
  4394.  
  4395. --###########################################################################################--
  4396. --vrcDischPtTable--
  4397. --###########################################################################################--
  4398.  
  4399. vrcDischPtTable OBJECT-TYPE
  4400. SYNTAX SEQUENCE OF VrcDischPtEntry
  4401. MAX-ACCESS not-accessible
  4402. STATUS current
  4403. DESCRIPTION
  4404. "Table that contains VRC discharge status"
  4405. ::= { vrc 18 }
  4406.  
  4407. vrcDischPtEntry OBJECT-TYPE
  4408. SYNTAX VrcDischPtEntry
  4409. MAX-ACCESS not-accessible
  4410. STATUS current
  4411. DESCRIPTION
  4412. "Entry in the vrcDischPtTable: each entry represents discharge data for
  4413. a VRC"
  4414. INDEX { vrcDischPtIndex }
  4415. ::= { vrcDischPtTable 1 }
  4416.  
  4417. VrcDischPtEntry ::= SEQUENCE {
  4418. vrcDischPtIndex Integer32,
  4419. vrcDischPtName SnmpAdminString,
  4420. vrcDischPtTemp Integer32,
  4421. vrcDischPtPressure Integer32,
  4422. vrcDischPtHighTempAlarm TruthValue,
  4423. vrcDischPtHighTempFreqAlarm TruthValue,
  4424. vrcDischPtTempSensorFailAlarm TruthValue
  4425. }
  4426.  
  4427. vrcDischPtIndex OBJECT-TYPE
  4428. SYNTAX Integer32(1..100)
  4429. MAX-ACCESS not-accessible
  4430. STATUS current
  4431. DESCRIPTION
  4432. "Unique id for each entry in the table"
  4433. ::= { vrcDischPtEntry 1 }
  4434.  
  4435. vrcDischPtName OBJECT-TYPE
  4436. SYNTAX SnmpAdminString(SIZE (1..25))
  4437. MAX-ACCESS read-only
  4438. STATUS current
  4439. DESCRIPTION
  4440. "Discharge name (factory-assigned)"
  4441. ::= { vrcDischPtEntry 2 }
  4442.  
  4443. vrcDischPtTemp OBJECT-TYPE
  4444. SYNTAX Integer32
  4445. UNITS "decidegrees"
  4446. MAX-ACCESS read-write
  4447. STATUS current
  4448. DESCRIPTION
  4449. "Discharge temperature value in tenths of a degree. Units are given by
  4450. temperatureUnits field in deviceInfo. The range is determined by the
  4451. current temperature units.
  4452. Celsius: -400 to 1560
  4453. Fahrenheit: -400 to 3128"
  4454. ::= { vrcDischPtEntry 3 }
  4455.  
  4456. vrcDischPtPressure OBJECT-TYPE
  4457. SYNTAX Integer32(0..460)
  4458. UNITS "decibars"
  4459. MAX-ACCESS read-write
  4460. STATUS current
  4461. DESCRIPTION
  4462. "Discharge air pressure value in tenths of a bar"
  4463. ::= { vrcDischPtEntry 4 }
  4464.  
  4465. vrcDischPtHighTempAlarm OBJECT-TYPE
  4466. SYNTAX TruthValue
  4467. MAX-ACCESS read-only
  4468. STATUS current
  4469. DESCRIPTION
  4470. "Discharge high temperature alarm state"
  4471. ::= { vrcDischPtEntry 5 }
  4472.  
  4473. vrcDischPtHighTempFreqAlarm OBJECT-TYPE
  4474. SYNTAX TruthValue
  4475. MAX-ACCESS read-only
  4476. STATUS current
  4477. DESCRIPTION
  4478. "Discharge high temperature frequently alarm state"
  4479. ::= { vrcDischPtEntry 6 }
  4480.  
  4481. vrcDischPtTempSensorFailAlarm OBJECT-TYPE
  4482. SYNTAX TruthValue
  4483. MAX-ACCESS read-only
  4484. STATUS current
  4485. DESCRIPTION
  4486. "Discharge temperature sensor failure alarm state"
  4487. ::= { vrcDischPtEntry 7 }
  4488.  
  4489. --###########################################################################################--
  4490. --vrcDischCfgTable--
  4491. --###########################################################################################--
  4492.  
  4493. vrcDischCfgTable OBJECT-TYPE
  4494. SYNTAX SEQUENCE OF VrcDischCfgEntry
  4495. MAX-ACCESS not-accessible
  4496. STATUS current
  4497. DESCRIPTION
  4498. "Table used for VRC discharge configuration"
  4499. ::= { vrc 19 }
  4500.  
  4501. vrcDischCfgEntry OBJECT-TYPE
  4502. SYNTAX VrcDischCfgEntry
  4503. MAX-ACCESS not-accessible
  4504. STATUS current
  4505. DESCRIPTION
  4506. "Entry in the vrcDischCfgTable: each entry contains config fields for
  4507. VRC discharge"
  4508. INDEX { vrcDischCfgIndex }
  4509. ::= { vrcDischCfgTable 1 }
  4510.  
  4511. VrcDischCfgEntry ::= SEQUENCE {
  4512. vrcDischCfgIndex Integer32,
  4513. vrcDischCfgTempCalValue Integer32,
  4514. vrcDischCfgPressCalValue Integer32,
  4515. vrcDischCfgHighTempAlmCtrl INTEGER,
  4516. vrcDischCfgHighTempFreqAlmCtrl INTEGER,
  4517. vrcDischCfgTempSensFailAlmCtrl INTEGER
  4518. }
  4519.  
  4520. vrcDischCfgIndex OBJECT-TYPE
  4521. SYNTAX Integer32(1..100)
  4522. MAX-ACCESS not-accessible
  4523. STATUS current
  4524. DESCRIPTION
  4525. "Unique id for each entry in the table"
  4526. ::= { vrcDischCfgEntry 1 }
  4527.  
  4528. vrcDischCfgTempCalValue OBJECT-TYPE
  4529. SYNTAX Integer32
  4530. UNITS "decidegrees"
  4531. MAX-ACCESS read-write
  4532. STATUS current
  4533. DESCRIPTION
  4534. "Discharge temperature calibration value in tenths of a degree. Units
  4535. are given by temperatureUnits field in deviceInfo. The settable range
  4536. is determined by the current temperature units.
  4537. Celsius: -100 to 100
  4538. Fahrenheit: -179 to 179"
  4539. ::= { vrcDischCfgEntry 2 }
  4540.  
  4541. vrcDischCfgPressCalValue OBJECT-TYPE
  4542. SYNTAX Integer32(-100..100)
  4543. UNITS "decibars"
  4544. MAX-ACCESS read-write
  4545. STATUS current
  4546. DESCRIPTION
  4547. "Discharge pressure calibration value in tenths of a bar"
  4548. ::= { vrcDischCfgEntry 3 }
  4549.  
  4550. vrcDischCfgHighTempAlmCtrl OBJECT-TYPE
  4551. SYNTAX INTEGER {
  4552. suspend(2),
  4553. open(3)
  4554. }
  4555. MAX-ACCESS read-write
  4556. STATUS current
  4557. DESCRIPTION
  4558. "Discharge high temperature alarm control:
  4559. 2 = suspend
  4560. 3 = open"
  4561. ::= { vrcDischCfgEntry 4 }
  4562.  
  4563. vrcDischCfgHighTempFreqAlmCtrl OBJECT-TYPE
  4564. SYNTAX INTEGER {
  4565. suspend(2),
  4566. open(3)
  4567. }
  4568. MAX-ACCESS read-write
  4569. STATUS current
  4570. DESCRIPTION
  4571. "Discharge high temperature frequenctly alarm control:
  4572. 2 = suspend
  4573. 3 = open"
  4574. ::= { vrcDischCfgEntry 5 }
  4575.  
  4576. vrcDischCfgTempSensFailAlmCtrl OBJECT-TYPE
  4577. SYNTAX INTEGER {
  4578. suspend(2),
  4579. open(3)
  4580. }
  4581. MAX-ACCESS read-write
  4582. STATUS current
  4583. DESCRIPTION
  4584. "Discharge temperature sensor failure alarm control:
  4585. 2 = suspend
  4586. 3 = open"
  4587. ::= { vrcDischCfgEntry 6 }
  4588.  
  4589. --###########################################################################################--
  4590. --vrcSuctPtTable--
  4591. --###########################################################################################--
  4592.  
  4593. vrcSuctPtTable OBJECT-TYPE
  4594. SYNTAX SEQUENCE OF VrcSuctPtEntry
  4595. MAX-ACCESS not-accessible
  4596. STATUS current
  4597. DESCRIPTION
  4598. "Table that contains VRC suction status"
  4599. ::= { vrc 20 }
  4600.  
  4601. vrcSuctPtEntry OBJECT-TYPE
  4602. SYNTAX VrcSuctPtEntry
  4603. MAX-ACCESS not-accessible
  4604. STATUS current
  4605. DESCRIPTION
  4606. "Entry in the vrcSuctPtTable: each entry represents suction data for a
  4607. VRC"
  4608. INDEX { vrcSuctPtIndex }
  4609. ::= { vrcSuctPtTable 1 }
  4610.  
  4611. VrcSuctPtEntry ::= SEQUENCE {
  4612. vrcSuctPtIndex Integer32,
  4613. vrcSuctPtName SnmpAdminString,
  4614. vrcSuctPtTemp Integer32,
  4615. vrcSuctPtPressure Integer32,
  4616. vrcSuctPtSuperHeatTemp Integer32,
  4617. vrcSuctPtTempSensorFailAlarm TruthValue
  4618. }
  4619.  
  4620. vrcSuctPtIndex OBJECT-TYPE
  4621. SYNTAX Integer32(1..100)
  4622. MAX-ACCESS not-accessible
  4623. STATUS current
  4624. DESCRIPTION
  4625. "Unique id for each entry in the table"
  4626. ::= { vrcSuctPtEntry 1 }
  4627.  
  4628. vrcSuctPtName OBJECT-TYPE
  4629. SYNTAX SnmpAdminString(SIZE (1..25))
  4630. MAX-ACCESS read-only
  4631. STATUS current
  4632. DESCRIPTION
  4633. "Suction name (factory-assigned)"
  4634. ::= { vrcSuctPtEntry 2 }
  4635.  
  4636. vrcSuctPtTemp OBJECT-TYPE
  4637. SYNTAX Integer32
  4638. UNITS "decidegrees"
  4639. MAX-ACCESS read-only
  4640. STATUS current
  4641. DESCRIPTION
  4642. "Suction temperature in tenths of a degree. Units are given by
  4643. temperatureUnits field in deviceInfo. The range is determined by the
  4644. current temperature units.
  4645. Celsius: -400 to 1000
  4646. Fahrenheit: -400 to 2120"
  4647. ::= { vrcSuctPtEntry 3 }
  4648.  
  4649. vrcSuctPtPressure OBJECT-TYPE
  4650. SYNTAX Integer32(0..173)
  4651. UNITS "decibars"
  4652. MAX-ACCESS read-only
  4653. STATUS current
  4654. DESCRIPTION
  4655. "Suction air pressure in tenths of a bar"
  4656. ::= { vrcSuctPtEntry 4 }
  4657.  
  4658. vrcSuctPtSuperHeatTemp OBJECT-TYPE
  4659. SYNTAX Integer32
  4660. UNITS "decidegrees"
  4661. MAX-ACCESS read-only
  4662. STATUS current
  4663. DESCRIPTION
  4664. "Suction super heat temperature in tenths of a degree. Units are given
  4665. by temperatureUnits field in deviceInfo. The range is determined by
  4666. the current temperature units.
  4667. Celsius: -400 to 1000
  4668. Fahrenheit: -400 to 2120"
  4669. ::= { vrcSuctPtEntry 5 }
  4670.  
  4671. vrcSuctPtTempSensorFailAlarm OBJECT-TYPE
  4672. SYNTAX TruthValue
  4673. MAX-ACCESS read-only
  4674. STATUS current
  4675. DESCRIPTION
  4676. "Suction temperature sensor failure alarm state"
  4677. ::= { vrcSuctPtEntry 6 }
  4678.  
  4679. --###########################################################################################--
  4680. --vrcSuctCfgTable--
  4681. --###########################################################################################--
  4682.  
  4683. vrcSuctCfgTable OBJECT-TYPE
  4684. SYNTAX SEQUENCE OF VrcSuctCfgEntry
  4685. MAX-ACCESS not-accessible
  4686. STATUS current
  4687. DESCRIPTION
  4688. "Table used for VRC suction configuration"
  4689. ::= { vrc 21 }
  4690.  
  4691. vrcSuctCfgEntry OBJECT-TYPE
  4692. SYNTAX VrcSuctCfgEntry
  4693. MAX-ACCESS not-accessible
  4694. STATUS current
  4695. DESCRIPTION
  4696. "Entry in the vrcSuctCfgTable: each entry contains config fields for
  4697. VRC suction"
  4698. INDEX { vrcSuctCfgIndex }
  4699. ::= { vrcSuctCfgTable 1 }
  4700.  
  4701. VrcSuctCfgEntry ::= SEQUENCE {
  4702. vrcSuctCfgIndex Integer32,
  4703. vrcSuctCfgPressCalValue Integer32,
  4704. vrcSuctCfgTempSensFailAlmCtrl INTEGER
  4705. }
  4706.  
  4707. vrcSuctCfgIndex OBJECT-TYPE
  4708. SYNTAX Integer32(1..100)
  4709. MAX-ACCESS not-accessible
  4710. STATUS current
  4711. DESCRIPTION
  4712. "Unique id for each entry in the table"
  4713. ::= { vrcSuctCfgEntry 1 }
  4714.  
  4715. vrcSuctCfgPressCalValue OBJECT-TYPE
  4716. SYNTAX Integer32(-100..100)
  4717. UNITS "decibars"
  4718. MAX-ACCESS read-write
  4719. STATUS current
  4720. DESCRIPTION
  4721. "Suction pressure calibration value in tenths of a bar"
  4722. ::= { vrcSuctCfgEntry 2 }
  4723.  
  4724. vrcSuctCfgTempSensFailAlmCtrl OBJECT-TYPE
  4725. SYNTAX INTEGER {
  4726. suspend(2),
  4727. open(3)
  4728. }
  4729. MAX-ACCESS read-write
  4730. STATUS current
  4731. DESCRIPTION
  4732. "Suction temperature sensor failure alarm control:
  4733. 2 = suspend
  4734. 3 = open"
  4735. ::= { vrcSuctCfgEntry 3 }
  4736.  
  4737. --###########################################################################################--
  4738. --Notifications--
  4739. --###########################################################################################--
  4740.  
  4741. trap OBJECT IDENTIFIER ::= { imd 32767 }
  4742.  
  4743. trapPrefix OBJECT IDENTIFIER ::= { trap 0 }
  4744.  
  4745. trapObj OBJECT IDENTIFIER ::= { trap 1 }
  4746.  
  4747.  
  4748. trapSeverity OBJECT-TYPE
  4749. SYNTAX INTEGER {
  4750. none(0),
  4751. warning(1),
  4752. alarm(2)
  4753. }
  4754. MAX-ACCESS accessible-for-notify
  4755. STATUS current
  4756. DESCRIPTION
  4757. "Indicates the severity of the trap:
  4758. 0 = None
  4759. 1 = Warning
  4760. 2 = Alarm"
  4761. ::= { trapObj 1 }
  4762.  
  4763. trapThreshType OBJECT-TYPE
  4764. SYNTAX INTEGER {
  4765. low(1),
  4766. high(2)
  4767. }
  4768. MAX-ACCESS accessible-for-notify
  4769. STATUS current
  4770. DESCRIPTION
  4771. "Only sent for threshold alarms. Identifies the threshold type:
  4772. 1 = Low
  4773. 2 = High"
  4774. ::= { trapObj 2 }
  4775.  
  4776. internalTestNOTIFY NOTIFICATION-TYPE
  4777. STATUS current
  4778. DESCRIPTION "Test SNMP Trap"
  4779. ::= { trapPrefix 10101 }
  4780.  
  4781. --#####deviceInfo#####--
  4782.  
  4783. --#####pdu#####--
  4784.  
  4785. --#####pduMainTable#####--
  4786.  
  4787. pduMainAvailNOTIFY NOTIFICATION-TYPE
  4788. OBJECTS {
  4789. pduMainAvail,
  4790. trapSeverity,
  4791. sysName,
  4792. pduMainLabel
  4793. }
  4794. STATUS current
  4795. DESCRIPTION "PDU availability trap"
  4796. ::= { trapPrefix 10305 }
  4797.  
  4798. pduMainAvailCLEAR NOTIFICATION-TYPE
  4799. OBJECTS {
  4800. pduMainAvail,
  4801. trapSeverity,
  4802. sysName,
  4803. pduMainLabel
  4804. }
  4805. STATUS current
  4806. DESCRIPTION "PDU availability clear trap"
  4807. ::= { trapPrefix 20305 }
  4808.  
  4809. pduTotalRealPowerNOTIFY NOTIFICATION-TYPE
  4810. OBJECTS {
  4811. pduTotalRealPower,
  4812. trapThreshType,
  4813. trapSeverity,
  4814. sysName,
  4815. pduMainLabel,
  4816. pduTotalLabel
  4817. }
  4818. STATUS current
  4819. DESCRIPTION "PDU total real power trap"
  4820. ::= { trapPrefix 10309 }
  4821.  
  4822. pduTotalRealPowerCLEAR NOTIFICATION-TYPE
  4823. OBJECTS {
  4824. pduTotalRealPower,
  4825. trapThreshType,
  4826. trapSeverity,
  4827. sysName,
  4828. pduMainLabel,
  4829. pduTotalLabel
  4830. }
  4831. STATUS current
  4832. DESCRIPTION "PDU total real power clear trap"
  4833. ::= { trapPrefix 20309 }
  4834.  
  4835. pduTotalApparentPowerNOTIFY NOTIFICATION-TYPE
  4836. OBJECTS {
  4837. pduTotalApparentPower,
  4838. trapThreshType,
  4839. trapSeverity,
  4840. sysName,
  4841. pduMainLabel,
  4842. pduTotalLabel
  4843. }
  4844. STATUS current
  4845. DESCRIPTION "PDU total apparent power trap"
  4846. ::= { trapPrefix 10310 }
  4847.  
  4848. pduTotalApparentPowerCLEAR NOTIFICATION-TYPE
  4849. OBJECTS {
  4850. pduTotalApparentPower,
  4851. trapThreshType,
  4852. trapSeverity,
  4853. sysName,
  4854. pduMainLabel,
  4855. pduTotalLabel
  4856. }
  4857. STATUS current
  4858. DESCRIPTION "PDU total apparent power clear trap"
  4859. ::= { trapPrefix 20310 }
  4860.  
  4861. pduTotalPowerFactorNOTIFY NOTIFICATION-TYPE
  4862. OBJECTS {
  4863. pduTotalPowerFactor,
  4864. trapThreshType,
  4865. trapSeverity,
  4866. sysName,
  4867. pduMainLabel,
  4868. pduTotalLabel
  4869. }
  4870. STATUS current
  4871. DESCRIPTION "PDU total power factor trap"
  4872. ::= { trapPrefix 10311 }
  4873.  
  4874. pduTotalPowerFactorCLEAR NOTIFICATION-TYPE
  4875. OBJECTS {
  4876. pduTotalPowerFactor,
  4877. trapThreshType,
  4878. trapSeverity,
  4879. sysName,
  4880. pduMainLabel,
  4881. pduTotalLabel
  4882. }
  4883. STATUS current
  4884. DESCRIPTION "PDU total power factor clear trap"
  4885. ::= { trapPrefix 20311 }
  4886.  
  4887. pduTotalEnergyNOTIFY NOTIFICATION-TYPE
  4888. OBJECTS {
  4889. pduTotalEnergy,
  4890. trapThreshType,
  4891. trapSeverity,
  4892. sysName,
  4893. pduMainLabel,
  4894. pduTotalLabel
  4895. }
  4896. STATUS current
  4897. DESCRIPTION "PDU total energy trap"
  4898. ::= { trapPrefix 10312 }
  4899.  
  4900. pduTotalEnergyCLEAR NOTIFICATION-TYPE
  4901. OBJECTS {
  4902. pduTotalEnergy,
  4903. trapThreshType,
  4904. trapSeverity,
  4905. sysName,
  4906. pduMainLabel,
  4907. pduTotalLabel
  4908. }
  4909. STATUS current
  4910. DESCRIPTION "PDU total energy clear trap"
  4911. ::= { trapPrefix 20312 }
  4912.  
  4913. --#####pduPhaseTable#####--
  4914.  
  4915. pduPhaseVoltageNOTIFY NOTIFICATION-TYPE
  4916. OBJECTS {
  4917. pduPhaseVoltage,
  4918. trapThreshType,
  4919. trapSeverity,
  4920. sysName,
  4921. pduMainLabel,
  4922. pduPhaseLabel
  4923. }
  4924. STATUS current
  4925. DESCRIPTION "PDU phase voltage trap"
  4926. ::= { trapPrefix 10324 }
  4927.  
  4928. pduPhaseVoltageCLEAR NOTIFICATION-TYPE
  4929. OBJECTS {
  4930. pduPhaseVoltage,
  4931. trapThreshType,
  4932. trapSeverity,
  4933. sysName,
  4934. pduMainLabel,
  4935. pduPhaseLabel
  4936. }
  4937. STATUS current
  4938. DESCRIPTION "PDU phase voltage clear trap"
  4939. ::= { trapPrefix 20324 }
  4940.  
  4941. pduPhaseCurrentNOTIFY NOTIFICATION-TYPE
  4942. OBJECTS {
  4943. pduPhaseCurrent,
  4944. trapThreshType,
  4945. trapSeverity,
  4946. sysName,
  4947. pduMainLabel,
  4948. pduPhaseLabel
  4949. }
  4950. STATUS current
  4951. DESCRIPTION "PDU phase current trap"
  4952. ::= { trapPrefix 10328 }
  4953.  
  4954. pduPhaseCurrentCLEAR NOTIFICATION-TYPE
  4955. OBJECTS {
  4956. pduPhaseCurrent,
  4957. trapThreshType,
  4958. trapSeverity,
  4959. sysName,
  4960. pduMainLabel,
  4961. pduPhaseLabel
  4962. }
  4963. STATUS current
  4964. DESCRIPTION "PDU phase current clear trap"
  4965. ::= { trapPrefix 20328 }
  4966.  
  4967. pduPhaseRealPowerNOTIFY NOTIFICATION-TYPE
  4968. OBJECTS {
  4969. pduPhaseRealPower,
  4970. trapThreshType,
  4971. trapSeverity,
  4972. sysName,
  4973. pduMainLabel,
  4974. pduPhaseLabel
  4975. }
  4976. STATUS current
  4977. DESCRIPTION "PDU phase real power trap"
  4978. ::= { trapPrefix 10332 }
  4979.  
  4980. pduPhaseRealPowerCLEAR NOTIFICATION-TYPE
  4981. OBJECTS {
  4982. pduPhaseRealPower,
  4983. trapThreshType,
  4984. trapSeverity,
  4985. sysName,
  4986. pduMainLabel,
  4987. pduPhaseLabel
  4988. }
  4989. STATUS current
  4990. DESCRIPTION "PDU phase real power clear trap"
  4991. ::= { trapPrefix 20332 }
  4992.  
  4993. pduPhaseApparentPowerNOTIFY NOTIFICATION-TYPE
  4994. OBJECTS {
  4995. pduPhaseApparentPower,
  4996. trapThreshType,
  4997. trapSeverity,
  4998. sysName,
  4999. pduMainLabel,
  5000. pduPhaseLabel
  5001. }
  5002. STATUS current
  5003. DESCRIPTION "PDU phase apparent power trap"
  5004. ::= { trapPrefix 10333 }
  5005.  
  5006. pduPhaseApparentPowerCLEAR NOTIFICATION-TYPE
  5007. OBJECTS {
  5008. pduPhaseApparentPower,
  5009. trapThreshType,
  5010. trapSeverity,
  5011. sysName,
  5012. pduMainLabel,
  5013. pduPhaseLabel
  5014. }
  5015. STATUS current
  5016. DESCRIPTION "PDU phase apparent power clear trap"
  5017. ::= { trapPrefix 20333 }
  5018.  
  5019. pduPhasePowerFactorNOTIFY NOTIFICATION-TYPE
  5020. OBJECTS {
  5021. pduPhasePowerFactor,
  5022. trapThreshType,
  5023. trapSeverity,
  5024. sysName,
  5025. pduMainLabel,
  5026. pduPhaseLabel
  5027. }
  5028. STATUS current
  5029. DESCRIPTION "PDU phase power factor trap"
  5030. ::= { trapPrefix 10334 }
  5031.  
  5032. pduPhasePowerFactorCLEAR NOTIFICATION-TYPE
  5033. OBJECTS {
  5034. pduPhasePowerFactor,
  5035. trapThreshType,
  5036. trapSeverity,
  5037. sysName,
  5038. pduMainLabel,
  5039. pduPhaseLabel
  5040. }
  5041. STATUS current
  5042. DESCRIPTION "PDU phase power factor clear trap"
  5043. ::= { trapPrefix 20334 }
  5044.  
  5045. pduPhaseEnergyNOTIFY NOTIFICATION-TYPE
  5046. OBJECTS {
  5047. pduPhaseEnergy,
  5048. trapThreshType,
  5049. trapSeverity,
  5050. sysName,
  5051. pduMainLabel,
  5052. pduPhaseLabel
  5053. }
  5054. STATUS current
  5055. DESCRIPTION "PDU phase energy trap"
  5056. ::= { trapPrefix 10335 }
  5057.  
  5058. pduPhaseEnergyCLEAR NOTIFICATION-TYPE
  5059. OBJECTS {
  5060. pduPhaseEnergy,
  5061. trapThreshType,
  5062. trapSeverity,
  5063. sysName,
  5064. pduMainLabel,
  5065. pduPhaseLabel
  5066. }
  5067. STATUS current
  5068. DESCRIPTION "PDU phase energy clear trap"
  5069. ::= { trapPrefix 20335 }
  5070.  
  5071. pduPhaseBalanceNOTIFY NOTIFICATION-TYPE
  5072. OBJECTS {
  5073. pduPhaseBalance,
  5074. trapThreshType,
  5075. trapSeverity,
  5076. sysName,
  5077. pduMainLabel,
  5078. pduPhaseLabel
  5079. }
  5080. STATUS current
  5081. DESCRIPTION "PDU phase balance trap"
  5082. ::= { trapPrefix 10337 }
  5083.  
  5084. pduPhaseBalanceCLEAR NOTIFICATION-TYPE
  5085. OBJECTS {
  5086. pduPhaseBalance,
  5087. trapThreshType,
  5088. trapSeverity,
  5089. sysName,
  5090. pduMainLabel,
  5091. pduPhaseLabel
  5092. }
  5093. STATUS current
  5094. DESCRIPTION "PDU phase balance clear trap"
  5095. ::= { trapPrefix 20337 }
  5096.  
  5097. pduPhaseCurrentCrestFactorNOTIFY NOTIFICATION-TYPE
  5098. OBJECTS {
  5099. pduPhaseCurrentCrestFactor,
  5100. trapThreshType,
  5101. trapSeverity,
  5102. sysName,
  5103. pduMainLabel,
  5104. pduPhaseLabel
  5105. }
  5106. STATUS current
  5107. DESCRIPTION "PDU phase current crest factor trap"
  5108. ::= { trapPrefix 10339 }
  5109.  
  5110. pduPhaseCurrentCrestFactorCLEAR NOTIFICATION-TYPE
  5111. OBJECTS {
  5112. pduPhaseCurrentCrestFactor,
  5113. trapThreshType,
  5114. trapSeverity,
  5115. sysName,
  5116. pduMainLabel,
  5117. pduPhaseLabel
  5118. }
  5119. STATUS current
  5120. DESCRIPTION "PDU phase current crest factor clear trap"
  5121. ::= { trapPrefix 20339 }
  5122.  
  5123. --#####pduBreakerTable#####--
  5124.  
  5125. pduBreakerCurrentNOTIFY NOTIFICATION-TYPE
  5126. OBJECTS {
  5127. pduBreakerCurrent,
  5128. trapThreshType,
  5129. trapSeverity,
  5130. sysName,
  5131. pduMainLabel,
  5132. pduBreakerLabel
  5133. }
  5134. STATUS current
  5135. DESCRIPTION "PDU breaker current trap"
  5136. ::= { trapPrefix 10354 }
  5137.  
  5138. pduBreakerCurrentCLEAR NOTIFICATION-TYPE
  5139. OBJECTS {
  5140. pduBreakerCurrent,
  5141. trapThreshType,
  5142. trapSeverity,
  5143. sysName,
  5144. pduMainLabel,
  5145. pduBreakerLabel
  5146. }
  5147. STATUS current
  5148. DESCRIPTION "PDU breaker current clear trap"
  5149. ::= { trapPrefix 20354 }
  5150.  
  5151. pduBreakerVoltageNOTIFY NOTIFICATION-TYPE
  5152. OBJECTS {
  5153. pduBreakerVoltage,
  5154. trapThreshType,
  5155. trapSeverity,
  5156. sysName,
  5157. pduMainLabel,
  5158. pduBreakerLabel
  5159. }
  5160. STATUS current
  5161. DESCRIPTION "PDU breaker voltage trap"
  5162. ::= { trapPrefix 10358 }
  5163.  
  5164. pduBreakerVoltageCLEAR NOTIFICATION-TYPE
  5165. OBJECTS {
  5166. pduBreakerVoltage,
  5167. trapThreshType,
  5168. trapSeverity,
  5169. sysName,
  5170. pduMainLabel,
  5171. pduBreakerLabel
  5172. }
  5173. STATUS current
  5174. DESCRIPTION "PDU breaker voltage clear trap"
  5175. ::= { trapPrefix 20358 }
  5176.  
  5177. pduBreakerRealPowerNOTIFY NOTIFICATION-TYPE
  5178. OBJECTS {
  5179. pduBreakerRealPower,
  5180. trapThreshType,
  5181. trapSeverity,
  5182. sysName,
  5183. pduMainLabel,
  5184. pduBreakerLabel
  5185. }
  5186. STATUS current
  5187. DESCRIPTION "PDU breaker real power trap"
  5188. ::= { trapPrefix 10362 }
  5189.  
  5190. pduBreakerRealPowerCLEAR NOTIFICATION-TYPE
  5191. OBJECTS {
  5192. pduBreakerRealPower,
  5193. trapThreshType,
  5194. trapSeverity,
  5195. sysName,
  5196. pduMainLabel,
  5197. pduBreakerLabel
  5198. }
  5199. STATUS current
  5200. DESCRIPTION "PDU breaker real power clear trap"
  5201. ::= { trapPrefix 20362 }
  5202.  
  5203. pduBreakerApparentPowerNOTIFY NOTIFICATION-TYPE
  5204. OBJECTS {
  5205. pduBreakerApparentPower,
  5206. trapThreshType,
  5207. trapSeverity,
  5208. sysName,
  5209. pduMainLabel,
  5210. pduBreakerLabel
  5211. }
  5212. STATUS current
  5213. DESCRIPTION "PDU breaker apparent power trap"
  5214. ::= { trapPrefix 10363 }
  5215.  
  5216. pduBreakerApparentPowerCLEAR NOTIFICATION-TYPE
  5217. OBJECTS {
  5218. pduBreakerApparentPower,
  5219. trapThreshType,
  5220. trapSeverity,
  5221. sysName,
  5222. pduMainLabel,
  5223. pduBreakerLabel
  5224. }
  5225. STATUS current
  5226. DESCRIPTION "PDU breaker apparent power clear trap"
  5227. ::= { trapPrefix 20363 }
  5228.  
  5229. pduBreakerPowerFactorNOTIFY NOTIFICATION-TYPE
  5230. OBJECTS {
  5231. pduBreakerPowerFactor,
  5232. trapThreshType,
  5233. trapSeverity,
  5234. sysName,
  5235. pduMainLabel,
  5236. pduBreakerLabel
  5237. }
  5238. STATUS current
  5239. DESCRIPTION "PDU breaker power factor trap"
  5240. ::= { trapPrefix 10364 }
  5241.  
  5242. pduBreakerPowerFactorCLEAR NOTIFICATION-TYPE
  5243. OBJECTS {
  5244. pduBreakerPowerFactor,
  5245. trapThreshType,
  5246. trapSeverity,
  5247. sysName,
  5248. pduMainLabel,
  5249. pduBreakerLabel
  5250. }
  5251. STATUS current
  5252. DESCRIPTION "PDU breaker power factor clear trap"
  5253. ::= { trapPrefix 20364 }
  5254.  
  5255. pduBreakerEnergyNOTIFY NOTIFICATION-TYPE
  5256. OBJECTS {
  5257. pduBreakerEnergy,
  5258. trapThreshType,
  5259. trapSeverity,
  5260. sysName,
  5261. pduMainLabel,
  5262. pduBreakerLabel
  5263. }
  5264. STATUS current
  5265. DESCRIPTION "PDU breaker energy trap"
  5266. ::= { trapPrefix 10365 }
  5267.  
  5268. pduBreakerEnergyCLEAR NOTIFICATION-TYPE
  5269. OBJECTS {
  5270. pduBreakerEnergy,
  5271. trapThreshType,
  5272. trapSeverity,
  5273. sysName,
  5274. pduMainLabel,
  5275. pduBreakerLabel
  5276. }
  5277. STATUS current
  5278. DESCRIPTION "PDU breaker energy clear trap"
  5279. ::= { trapPrefix 20365 }
  5280.  
  5281. --#####pduLineTable#####--
  5282.  
  5283. pduLineCurrentNOTIFY NOTIFICATION-TYPE
  5284. OBJECTS {
  5285. pduLineCurrent,
  5286. trapThreshType,
  5287. trapSeverity,
  5288. sysName,
  5289. pduMainLabel,
  5290. pduLineLabel
  5291. }
  5292. STATUS current
  5293. DESCRIPTION "PDU line current trap"
  5294. ::= { trapPrefix 10374 }
  5295.  
  5296. pduLineCurrentCLEAR NOTIFICATION-TYPE
  5297. OBJECTS {
  5298. pduLineCurrent,
  5299. trapThreshType,
  5300. trapSeverity,
  5301. sysName,
  5302. pduMainLabel,
  5303. pduLineLabel
  5304. }
  5305. STATUS current
  5306. DESCRIPTION "PDU line current clear trap"
  5307. ::= { trapPrefix 20374 }
  5308.  
  5309. --#####pduOutletSwitchTable#####--
  5310.  
  5311. --#####pduOutletMeterTable#####--
  5312.  
  5313. pduOutletMeterVoltageNOTIFY NOTIFICATION-TYPE
  5314. OBJECTS {
  5315. pduOutletMeterVoltage,
  5316. trapThreshType,
  5317. trapSeverity,
  5318. sysName,
  5319. pduMainLabel,
  5320. pduOutletMeterLabel
  5321. }
  5322. STATUS current
  5323. DESCRIPTION "PDU outlet voltage trap"
  5324. ::= { trapPrefix 10385 }
  5325.  
  5326. pduOutletMeterVoltageCLEAR NOTIFICATION-TYPE
  5327. OBJECTS {
  5328. pduOutletMeterVoltage,
  5329. trapThreshType,
  5330. trapSeverity,
  5331. sysName,
  5332. pduMainLabel,
  5333. pduOutletMeterLabel
  5334. }
  5335. STATUS current
  5336. DESCRIPTION "PDU outlet voltage clear trap"
  5337. ::= { trapPrefix 20385 }
  5338.  
  5339. pduOutletMeterCurrentNOTIFY NOTIFICATION-TYPE
  5340. OBJECTS {
  5341. pduOutletMeterCurrent,
  5342. trapThreshType,
  5343. trapSeverity,
  5344. sysName,
  5345. pduMainLabel,
  5346. pduOutletMeterLabel
  5347. }
  5348. STATUS current
  5349. DESCRIPTION "PDU outlet current trap"
  5350. ::= { trapPrefix 10389 }
  5351.  
  5352. pduOutletMeterCurrentCLEAR NOTIFICATION-TYPE
  5353. OBJECTS {
  5354. pduOutletMeterCurrent,
  5355. trapThreshType,
  5356. trapSeverity,
  5357. sysName,
  5358. pduMainLabel,
  5359. pduOutletMeterLabel
  5360. }
  5361. STATUS current
  5362. DESCRIPTION "PDU outlet current clear trap"
  5363. ::= { trapPrefix 20389 }
  5364.  
  5365. pduOutletMeterRealPowerNOTIFY NOTIFICATION-TYPE
  5366. OBJECTS {
  5367. pduOutletMeterRealPower,
  5368. trapThreshType,
  5369. trapSeverity,
  5370. sysName,
  5371. pduMainLabel,
  5372. pduOutletMeterLabel
  5373. }
  5374. STATUS current
  5375. DESCRIPTION "PDU outlet real power trap"
  5376. ::= { trapPrefix 10393 }
  5377.  
  5378. pduOutletMeterRealPowerCLEAR NOTIFICATION-TYPE
  5379. OBJECTS {
  5380. pduOutletMeterRealPower,
  5381. trapThreshType,
  5382. trapSeverity,
  5383. sysName,
  5384. pduMainLabel,
  5385. pduOutletMeterLabel
  5386. }
  5387. STATUS current
  5388. DESCRIPTION "PDU outlet real power clear trap"
  5389. ::= { trapPrefix 20393 }
  5390.  
  5391. pduOutletMeterApparentPowerNOTIFY NOTIFICATION-TYPE
  5392. OBJECTS {
  5393. pduOutletMeterApparentPower,
  5394. trapThreshType,
  5395. trapSeverity,
  5396. sysName,
  5397. pduMainLabel,
  5398. pduOutletMeterLabel
  5399. }
  5400. STATUS current
  5401. DESCRIPTION "PDU outlet apparent power trap"
  5402. ::= { trapPrefix 10394 }
  5403.  
  5404. pduOutletMeterApparentPowerCLEAR NOTIFICATION-TYPE
  5405. OBJECTS {
  5406. pduOutletMeterApparentPower,
  5407. trapThreshType,
  5408. trapSeverity,
  5409. sysName,
  5410. pduMainLabel,
  5411. pduOutletMeterLabel
  5412. }
  5413. STATUS current
  5414. DESCRIPTION "PDU outlet apparent power clear trap"
  5415. ::= { trapPrefix 20394 }
  5416.  
  5417. pduOutletMeterPowerFactorNOTIFY NOTIFICATION-TYPE
  5418. OBJECTS {
  5419. pduOutletMeterPowerFactor,
  5420. trapThreshType,
  5421. trapSeverity,
  5422. sysName,
  5423. pduMainLabel,
  5424. pduOutletMeterLabel
  5425. }
  5426. STATUS current
  5427. DESCRIPTION "PDU outlet power factor trap"
  5428. ::= { trapPrefix 10395 }
  5429.  
  5430. pduOutletMeterPowerFactorCLEAR NOTIFICATION-TYPE
  5431. OBJECTS {
  5432. pduOutletMeterPowerFactor,
  5433. trapThreshType,
  5434. trapSeverity,
  5435. sysName,
  5436. pduMainLabel,
  5437. pduOutletMeterLabel
  5438. }
  5439. STATUS current
  5440. DESCRIPTION "PDU outlet power factor clear trap"
  5441. ::= { trapPrefix 20395 }
  5442.  
  5443. pduOutletMeterEnergyNOTIFY NOTIFICATION-TYPE
  5444. OBJECTS {
  5445. pduOutletMeterEnergy,
  5446. trapThreshType,
  5447. trapSeverity,
  5448. sysName,
  5449. pduMainLabel,
  5450. pduOutletMeterLabel
  5451. }
  5452. STATUS current
  5453. DESCRIPTION "PDU outlet energy trap"
  5454. ::= { trapPrefix 10396 }
  5455.  
  5456. pduOutletMeterEnergyCLEAR NOTIFICATION-TYPE
  5457. OBJECTS {
  5458. pduOutletMeterEnergy,
  5459. trapThreshType,
  5460. trapSeverity,
  5461. sysName,
  5462. pduMainLabel,
  5463. pduOutletMeterLabel
  5464. }
  5465. STATUS current
  5466. DESCRIPTION "PDU outlet energy clear trap"
  5467. ::= { trapPrefix 20396 }
  5468.  
  5469. pduOutletCurrentCrestFactorNOTIFY NOTIFICATION-TYPE
  5470. OBJECTS {
  5471. pduOutletCurrentCrestFactor,
  5472. trapThreshType,
  5473. trapSeverity,
  5474. sysName,
  5475. pduMainLabel,
  5476. pduOutletMeterLabel
  5477. }
  5478. STATUS current
  5479. DESCRIPTION "PDU outlet current crest factor trap"
  5480. ::= { trapPrefix 10400 }
  5481.  
  5482. pduOutletCurrentCrestFactorCLEAR NOTIFICATION-TYPE
  5483. OBJECTS {
  5484. pduOutletCurrentCrestFactor,
  5485. trapThreshType,
  5486. trapSeverity,
  5487. sysName,
  5488. pduMainLabel,
  5489. pduOutletMeterLabel
  5490. }
  5491. STATUS current
  5492. DESCRIPTION "PDU outlet current crest factor clear trap"
  5493. ::= { trapPrefix 20400 }
  5494.  
  5495. --#####tempSensorTable#####--
  5496.  
  5497. tempSensorAvailNOTIFY NOTIFICATION-TYPE
  5498. OBJECTS {
  5499. tempSensorAvail,
  5500. trapSeverity,
  5501. sysName,
  5502. tempSensorLabel
  5503. }
  5504. STATUS current
  5505. DESCRIPTION "RT availability trap"
  5506. ::= { trapPrefix 10404 }
  5507.  
  5508. tempSensorAvailCLEAR NOTIFICATION-TYPE
  5509. OBJECTS {
  5510. tempSensorAvail,
  5511. trapSeverity,
  5512. sysName,
  5513. tempSensorLabel
  5514. }
  5515. STATUS current
  5516. DESCRIPTION "RT availability clear trap"
  5517. ::= { trapPrefix 20404 }
  5518.  
  5519. tempSensorTempNOTIFY NOTIFICATION-TYPE
  5520. OBJECTS {
  5521. tempSensorTemp,
  5522. temperatureUnits,
  5523. trapThreshType,
  5524. trapSeverity,
  5525. sysName,
  5526. tempSensorLabel
  5527. }
  5528. STATUS current
  5529. DESCRIPTION "RT temperature trap"
  5530. ::= { trapPrefix 10405 }
  5531.  
  5532. tempSensorTempCLEAR NOTIFICATION-TYPE
  5533. OBJECTS {
  5534. tempSensorTemp,
  5535. temperatureUnits,
  5536. trapThreshType,
  5537. trapSeverity,
  5538. sysName,
  5539. tempSensorLabel
  5540. }
  5541. STATUS current
  5542. DESCRIPTION "RT temperature clear trap"
  5543. ::= { trapPrefix 20405 }
  5544.  
  5545. --#####airFlowSensorTable#####--
  5546.  
  5547. airFlowSensorAvailNOTIFY NOTIFICATION-TYPE
  5548. OBJECTS {
  5549. airFlowSensorAvail,
  5550. trapSeverity,
  5551. sysName,
  5552. airFlowSensorLabel
  5553. }
  5554. STATUS current
  5555. DESCRIPTION "AFHT3 availability trap"
  5556. ::= { trapPrefix 10504 }
  5557.  
  5558. airFlowSensorAvailCLEAR NOTIFICATION-TYPE
  5559. OBJECTS {
  5560. airFlowSensorAvail,
  5561. trapSeverity,
  5562. sysName,
  5563. airFlowSensorLabel
  5564. }
  5565. STATUS current
  5566. DESCRIPTION "AFHT3 availability clear trap"
  5567. ::= { trapPrefix 20504 }
  5568.  
  5569. airFlowSensorTempNOTIFY NOTIFICATION-TYPE
  5570. OBJECTS {
  5571. airFlowSensorTemp,
  5572. temperatureUnits,
  5573. trapThreshType,
  5574. trapSeverity,
  5575. sysName,
  5576. airFlowSensorLabel
  5577. }
  5578. STATUS current
  5579. DESCRIPTION "AFHT3 temperature trap"
  5580. ::= { trapPrefix 10505 }
  5581.  
  5582. airFlowSensorTempCLEAR NOTIFICATION-TYPE
  5583. OBJECTS {
  5584. airFlowSensorTemp,
  5585. temperatureUnits,
  5586. trapThreshType,
  5587. trapSeverity,
  5588. sysName,
  5589. airFlowSensorLabel
  5590. }
  5591. STATUS current
  5592. DESCRIPTION "AFHT3 temperature clear trap"
  5593. ::= { trapPrefix 20505 }
  5594.  
  5595. airFlowSensorFlowNOTIFY NOTIFICATION-TYPE
  5596. OBJECTS {
  5597. airFlowSensorFlow,
  5598. trapThreshType,
  5599. trapSeverity,
  5600. sysName,
  5601. airFlowSensorLabel
  5602. }
  5603. STATUS current
  5604. DESCRIPTION "AFHT3 airflow trap"
  5605. ::= { trapPrefix 10506 }
  5606.  
  5607. airFlowSensorFlowCLEAR NOTIFICATION-TYPE
  5608. OBJECTS {
  5609. airFlowSensorFlow,
  5610. trapThreshType,
  5611. trapSeverity,
  5612. sysName,
  5613. airFlowSensorLabel
  5614. }
  5615. STATUS current
  5616. DESCRIPTION "AFHT3 airflow clear trap"
  5617. ::= { trapPrefix 20506 }
  5618.  
  5619. airFlowSensorHumidityNOTIFY NOTIFICATION-TYPE
  5620. OBJECTS {
  5621. airFlowSensorHumidity,
  5622. trapThreshType,
  5623. trapSeverity,
  5624. sysName,
  5625. airFlowSensorLabel
  5626. }
  5627. STATUS current
  5628. DESCRIPTION "AFHT3 humidity trap"
  5629. ::= { trapPrefix 10507 }
  5630.  
  5631. airFlowSensorHumidityCLEAR NOTIFICATION-TYPE
  5632. OBJECTS {
  5633. airFlowSensorHumidity,
  5634. trapThreshType,
  5635. trapSeverity,
  5636. sysName,
  5637. airFlowSensorLabel
  5638. }
  5639. STATUS current
  5640. DESCRIPTION "AFHT3 humidity clear trap"
  5641. ::= { trapPrefix 20507 }
  5642.  
  5643. airFlowSensorDewPointNOTIFY NOTIFICATION-TYPE
  5644. OBJECTS {
  5645. airFlowSensorDewPoint,
  5646. temperatureUnits,
  5647. trapThreshType,
  5648. trapSeverity,
  5649. sysName,
  5650. airFlowSensorLabel
  5651. }
  5652. STATUS current
  5653. DESCRIPTION "AFHT3 dewpoint trap"
  5654. ::= { trapPrefix 10508 }
  5655.  
  5656. airFlowSensorDewPointCLEAR NOTIFICATION-TYPE
  5657. OBJECTS {
  5658. airFlowSensorDewPoint,
  5659. temperatureUnits,
  5660. trapThreshType,
  5661. trapSeverity,
  5662. sysName,
  5663. airFlowSensorLabel
  5664. }
  5665. STATUS current
  5666. DESCRIPTION "AFHT3 dewpoint clear trap"
  5667. ::= { trapPrefix 20508 }
  5668.  
  5669. --#####t3hdSensorTable#####--
  5670.  
  5671. t3hdSensorAvailNOTIFY NOTIFICATION-TYPE
  5672. OBJECTS {
  5673. t3hdSensorAvail,
  5674. trapSeverity,
  5675. sysName,
  5676. t3hdSensorLabel
  5677. }
  5678. STATUS current
  5679. DESCRIPTION "T3HD availability trap"
  5680. ::= { trapPrefix 10804 }
  5681.  
  5682. t3hdSensorAvailCLEAR NOTIFICATION-TYPE
  5683. OBJECTS {
  5684. t3hdSensorAvail,
  5685. trapSeverity,
  5686. sysName,
  5687. t3hdSensorLabel
  5688. }
  5689. STATUS current
  5690. DESCRIPTION "T3HD availability clear trap"
  5691. ::= { trapPrefix 20804 }
  5692.  
  5693. t3hdSensorIntTempNOTIFY NOTIFICATION-TYPE
  5694. OBJECTS {
  5695. t3hdSensorIntTemp,
  5696. temperatureUnits,
  5697. trapThreshType,
  5698. trapSeverity,
  5699. sysName,
  5700. t3hdSensorLabel,
  5701. t3hdSensorIntLabel
  5702. }
  5703. STATUS current
  5704. DESCRIPTION "T3HD Internal temperature trap"
  5705. ::= { trapPrefix 10806 }
  5706.  
  5707. t3hdSensorIntTempCLEAR NOTIFICATION-TYPE
  5708. OBJECTS {
  5709. t3hdSensorIntTemp,
  5710. temperatureUnits,
  5711. trapThreshType,
  5712. trapSeverity,
  5713. sysName,
  5714. t3hdSensorLabel,
  5715. t3hdSensorIntLabel
  5716. }
  5717. STATUS current
  5718. DESCRIPTION "T3HD Internal temperature clear trap"
  5719. ::= { trapPrefix 20806 }
  5720.  
  5721. t3hdSensorIntHumidityNOTIFY NOTIFICATION-TYPE
  5722. OBJECTS {
  5723. t3hdSensorIntHumidity,
  5724. trapThreshType,
  5725. trapSeverity,
  5726. sysName,
  5727. t3hdSensorLabel,
  5728. t3hdSensorIntLabel
  5729. }
  5730. STATUS current
  5731. DESCRIPTION "T3HD Internal humidity trap"
  5732. ::= { trapPrefix 10807 }
  5733.  
  5734. t3hdSensorIntHumidityCLEAR NOTIFICATION-TYPE
  5735. OBJECTS {
  5736. t3hdSensorIntHumidity,
  5737. trapThreshType,
  5738. trapSeverity,
  5739. sysName,
  5740. t3hdSensorLabel,
  5741. t3hdSensorIntLabel
  5742. }
  5743. STATUS current
  5744. DESCRIPTION "T3HD Internal humidity clear trap"
  5745. ::= { trapPrefix 20807 }
  5746.  
  5747. t3hdSensorIntDewPointNOTIFY NOTIFICATION-TYPE
  5748. OBJECTS {
  5749. t3hdSensorIntDewPoint,
  5750. temperatureUnits,
  5751. trapThreshType,
  5752. trapSeverity,
  5753. sysName,
  5754. t3hdSensorLabel,
  5755. t3hdSensorIntLabel
  5756. }
  5757. STATUS current
  5758. DESCRIPTION "T3HD Internal dewpoint trap"
  5759. ::= { trapPrefix 10808 }
  5760.  
  5761. t3hdSensorIntDewPointCLEAR NOTIFICATION-TYPE
  5762. OBJECTS {
  5763. t3hdSensorIntDewPoint,
  5764. temperatureUnits,
  5765. trapThreshType,
  5766. trapSeverity,
  5767. sysName,
  5768. t3hdSensorLabel,
  5769. t3hdSensorIntLabel
  5770. }
  5771. STATUS current
  5772. DESCRIPTION "T3HD Internal dewpoint clear trap"
  5773. ::= { trapPrefix 20808 }
  5774.  
  5775. t3hdSensorExtATempNOTIFY NOTIFICATION-TYPE
  5776. OBJECTS {
  5777. t3hdSensorExtATemp,
  5778. temperatureUnits,
  5779. trapThreshType,
  5780. trapSeverity,
  5781. sysName,
  5782. t3hdSensorLabel,
  5783. t3hdSensorExtALabel
  5784. }
  5785. STATUS current
  5786. DESCRIPTION "T3HD External A temperature trap"
  5787. ::= { trapPrefix 10811 }
  5788.  
  5789. t3hdSensorExtATempCLEAR NOTIFICATION-TYPE
  5790. OBJECTS {
  5791. t3hdSensorExtATemp,
  5792. temperatureUnits,
  5793. trapThreshType,
  5794. trapSeverity,
  5795. sysName,
  5796. t3hdSensorLabel,
  5797. t3hdSensorExtALabel
  5798. }
  5799. STATUS current
  5800. DESCRIPTION "T3HD External A temperature clear trap"
  5801. ::= { trapPrefix 20811 }
  5802.  
  5803. t3hdSensorExtBTempNOTIFY NOTIFICATION-TYPE
  5804. OBJECTS {
  5805. t3hdSensorExtBTemp,
  5806. temperatureUnits,
  5807. trapThreshType,
  5808. trapSeverity,
  5809. sysName,
  5810. t3hdSensorLabel,
  5811. t3hdSensorExtBLabel
  5812. }
  5813. STATUS current
  5814. DESCRIPTION "T3HD External B temperature trap"
  5815. ::= { trapPrefix 10814 }
  5816.  
  5817. t3hdSensorExtBTempCLEAR NOTIFICATION-TYPE
  5818. OBJECTS {
  5819. t3hdSensorExtBTemp,
  5820. temperatureUnits,
  5821. trapThreshType,
  5822. trapSeverity,
  5823. sysName,
  5824. t3hdSensorLabel,
  5825. t3hdSensorExtBLabel
  5826. }
  5827. STATUS current
  5828. DESCRIPTION "T3HD External B temperature clear trap"
  5829. ::= { trapPrefix 20814 }
  5830.  
  5831. --#####thdSensorTable#####--
  5832.  
  5833. thdSensorAvailNOTIFY NOTIFICATION-TYPE
  5834. OBJECTS {
  5835. thdSensorAvail,
  5836. trapSeverity,
  5837. sysName,
  5838. thdSensorLabel
  5839. }
  5840. STATUS current
  5841. DESCRIPTION "THD availability trap"
  5842. ::= { trapPrefix 10904 }
  5843.  
  5844. thdSensorAvailCLEAR NOTIFICATION-TYPE
  5845. OBJECTS {
  5846. thdSensorAvail,
  5847. trapSeverity,
  5848. sysName,
  5849. thdSensorLabel
  5850. }
  5851. STATUS current
  5852. DESCRIPTION "THD availability clear trap"
  5853. ::= { trapPrefix 20904 }
  5854.  
  5855. thdSensorTempNOTIFY NOTIFICATION-TYPE
  5856. OBJECTS {
  5857. thdSensorTemp,
  5858. temperatureUnits,
  5859. trapThreshType,
  5860. trapSeverity,
  5861. sysName,
  5862. thdSensorLabel
  5863. }
  5864. STATUS current
  5865. DESCRIPTION "THD temperature trap"
  5866. ::= { trapPrefix 10905 }
  5867.  
  5868. thdSensorTempCLEAR NOTIFICATION-TYPE
  5869. OBJECTS {
  5870. thdSensorTemp,
  5871. temperatureUnits,
  5872. trapThreshType,
  5873. trapSeverity,
  5874. sysName,
  5875. thdSensorLabel
  5876. }
  5877. STATUS current
  5878. DESCRIPTION "THD temperature clear trap"
  5879. ::= { trapPrefix 20905 }
  5880.  
  5881. thdSensorHumidityNOTIFY NOTIFICATION-TYPE
  5882. OBJECTS {
  5883. thdSensorHumidity,
  5884. trapThreshType,
  5885. trapSeverity,
  5886. sysName,
  5887. thdSensorLabel
  5888. }
  5889. STATUS current
  5890. DESCRIPTION "THD humidity trap"
  5891. ::= { trapPrefix 10906 }
  5892.  
  5893. thdSensorHumidityCLEAR NOTIFICATION-TYPE
  5894. OBJECTS {
  5895. thdSensorHumidity,
  5896. trapThreshType,
  5897. trapSeverity,
  5898. sysName,
  5899. thdSensorLabel
  5900. }
  5901. STATUS current
  5902. DESCRIPTION "THD humidity clear trap"
  5903. ::= { trapPrefix 20906 }
  5904.  
  5905. thdSensorDewPointNOTIFY NOTIFICATION-TYPE
  5906. OBJECTS {
  5907. thdSensorDewPoint,
  5908. temperatureUnits,
  5909. trapThreshType,
  5910. trapSeverity,
  5911. sysName,
  5912. thdSensorLabel
  5913. }
  5914. STATUS current
  5915. DESCRIPTION "THD dewpoint trap"
  5916. ::= { trapPrefix 10907 }
  5917.  
  5918. thdSensorDewPointCLEAR NOTIFICATION-TYPE
  5919. OBJECTS {
  5920. thdSensorDewPoint,
  5921. temperatureUnits,
  5922. trapThreshType,
  5923. trapSeverity,
  5924. sysName,
  5925. thdSensorLabel
  5926. }
  5927. STATUS current
  5928. DESCRIPTION "THD dewpoint clear trap"
  5929. ::= { trapPrefix 20907 }
  5930.  
  5931. --#####a2dSensorTable#####--
  5932.  
  5933. a2dSensorAvailNOTIFY NOTIFICATION-TYPE
  5934. OBJECTS {
  5935. a2dSensorAvail,
  5936. trapSeverity,
  5937. sysName,
  5938. a2dSensorLabel
  5939. }
  5940. STATUS current
  5941. DESCRIPTION "A2D availability trap"
  5942. ::= { trapPrefix 11104 }
  5943.  
  5944. a2dSensorAvailCLEAR NOTIFICATION-TYPE
  5945. OBJECTS {
  5946. a2dSensorAvail,
  5947. trapSeverity,
  5948. sysName,
  5949. a2dSensorLabel
  5950. }
  5951. STATUS current
  5952. DESCRIPTION "A2D availability clear trap"
  5953. ::= { trapPrefix 21104 }
  5954.  
  5955. a2dSensorValueNOTIFY NOTIFICATION-TYPE
  5956. OBJECTS {
  5957. a2dSensorValue,
  5958. trapThreshType,
  5959. trapSeverity,
  5960. sysName,
  5961. a2dSensorLabel,
  5962. a2dSensorAnalogLabel,
  5963. a2dSensorDisplayValue
  5964. }
  5965. STATUS current
  5966. DESCRIPTION "A2D measurement trap"
  5967. ::= { trapPrefix 11105 }
  5968.  
  5969. a2dSensorValueCLEAR NOTIFICATION-TYPE
  5970. OBJECTS {
  5971. a2dSensorValue,
  5972. trapThreshType,
  5973. trapSeverity,
  5974. sysName,
  5975. a2dSensorLabel,
  5976. a2dSensorAnalogLabel,
  5977. a2dSensorDisplayValue
  5978. }
  5979. STATUS current
  5980. DESCRIPTION "A2D measurement clear trap"
  5981. ::= { trapPrefix 21105 }
  5982.  
  5983. --#####humiditySensorTable#####--
  5984.  
  5985. humiditySensorAvailNOTIFY NOTIFICATION-TYPE
  5986. OBJECTS {
  5987. humiditySensorAvail,
  5988. trapSeverity,
  5989. sysName,
  5990. humiditySensorLabel
  5991. }
  5992. STATUS current
  5993. DESCRIPTION "Remote humidity availability trap"
  5994. ::= { trapPrefix 11204 }
  5995.  
  5996. humiditySensorAvailCLEAR NOTIFICATION-TYPE
  5997. OBJECTS {
  5998. humiditySensorAvail,
  5999. trapSeverity,
  6000. sysName,
  6001. humiditySensorLabel
  6002. }
  6003. STATUS current
  6004. DESCRIPTION "Remote humidity availability clear trap"
  6005. ::= { trapPrefix 21204 }
  6006.  
  6007. humiditySensorValueNOTIFY NOTIFICATION-TYPE
  6008. OBJECTS {
  6009. humiditySensorValue,
  6010. trapThreshType,
  6011. trapSeverity,
  6012. sysName,
  6013. humiditySensorLabel
  6014. }
  6015. STATUS current
  6016. DESCRIPTION "Remote humidity value trap"
  6017. ::= { trapPrefix 11205 }
  6018.  
  6019. humiditySensorValueCLEAR NOTIFICATION-TYPE
  6020. OBJECTS {
  6021. humiditySensorValue,
  6022. trapThreshType,
  6023. trapSeverity,
  6024. sysName,
  6025. humiditySensorLabel
  6026. }
  6027. STATUS current
  6028. DESCRIPTION "Remote humidity value clear trap"
  6029. ::= { trapPrefix 21205 }
  6030.  
  6031. --#####sn2dSensorTable#####--
  6032.  
  6033. sn2dSensorAvailNOTIFY NOTIFICATION-TYPE
  6034. OBJECTS {
  6035. sn2dSensorAvail,
  6036. trapSeverity,
  6037. sysName,
  6038. sn2dSensorLabel
  6039. }
  6040. STATUS current
  6041. DESCRIPTION "SN-2D availability trap"
  6042. ::= { trapPrefix 11304 }
  6043.  
  6044. sn2dSensorAvailCLEAR NOTIFICATION-TYPE
  6045. OBJECTS {
  6046. sn2dSensorAvail,
  6047. trapSeverity,
  6048. sysName,
  6049. sn2dSensorLabel
  6050. }
  6051. STATUS current
  6052. DESCRIPTION "SN-2D availability clear trap"
  6053. ::= { trapPrefix 21304 }
  6054.  
  6055. sn2dSensorDoor1StateNOTIFY NOTIFICATION-TYPE
  6056. OBJECTS {
  6057. sn2dSensorDoor1State,
  6058. trapThreshType,
  6059. trapSeverity,
  6060. sysName,
  6061. sn2dSensorLabel,
  6062. sn2dSensorDoor1Label,
  6063. sn2dSensorDoor1DisplayState
  6064. }
  6065. STATUS current
  6066. DESCRIPTION "SN-2D Door switch 1 state trap"
  6067. ::= { trapPrefix 11306 }
  6068.  
  6069. sn2dSensorDoor1StateCLEAR NOTIFICATION-TYPE
  6070. OBJECTS {
  6071. sn2dSensorDoor1State,
  6072. trapThreshType,
  6073. trapSeverity,
  6074. sysName,
  6075. sn2dSensorLabel,
  6076. sn2dSensorDoor1Label,
  6077. sn2dSensorDoor1DisplayState
  6078. }
  6079. STATUS current
  6080. DESCRIPTION "SN-2D Door switch 1 state clear trap"
  6081. ::= { trapPrefix 21306 }
  6082.  
  6083. sn2dSensorDoor2StateNOTIFY NOTIFICATION-TYPE
  6084. OBJECTS {
  6085. sn2dSensorDoor2State,
  6086. trapThreshType,
  6087. trapSeverity,
  6088. sysName,
  6089. sn2dSensorLabel,
  6090. sn2dSensorDoor2Label,
  6091. sn2dSensorDoor2DisplayState
  6092. }
  6093. STATUS current
  6094. DESCRIPTION "SN-2D Door switch 2 state trap"
  6095. ::= { trapPrefix 11309 }
  6096.  
  6097. sn2dSensorDoor2StateCLEAR NOTIFICATION-TYPE
  6098. OBJECTS {
  6099. sn2dSensorDoor2State,
  6100. trapThreshType,
  6101. trapSeverity,
  6102. sysName,
  6103. sn2dSensorLabel,
  6104. sn2dSensorDoor2Label,
  6105. sn2dSensorDoor2DisplayState
  6106. }
  6107. STATUS current
  6108. DESCRIPTION "SN-2D Door switch 2 state clear trap"
  6109. ::= { trapPrefix 21309 }
  6110.  
  6111. --#####cooling#####--
  6112.  
  6113. --#####vrc#####--
  6114.  
  6115. --#####vrcMainTable#####--
  6116.  
  6117. vrcMainAvailNOTIFY NOTIFICATION-TYPE
  6118. OBJECTS {
  6119. vrcMainAvail,
  6120. trapSeverity,
  6121. sysName,
  6122. vrcMainLabel
  6123. }
  6124. STATUS current
  6125. DESCRIPTION "VRC availability trap"
  6126. ::= { trapPrefix 13001 }
  6127.  
  6128. vrcMainAvailCLEAR NOTIFICATION-TYPE
  6129. OBJECTS {
  6130. vrcMainAvail,
  6131. trapSeverity,
  6132. sysName,
  6133. vrcMainLabel
  6134. }
  6135. STATUS current
  6136. DESCRIPTION "VRC availability clear trap"
  6137. ::= { trapPrefix 23001 }
  6138.  
  6139. --#####vrcMainPtTable#####--
  6140.  
  6141. --#####vrcMainCfgTable#####--
  6142.  
  6143. --#####vrcOutFanPtTable#####--
  6144.  
  6145. vrcOutFanPtSpeedNOTIFY NOTIFICATION-TYPE
  6146. OBJECTS {
  6147. vrcOutFanPtSpeed,
  6148. trapThreshType,
  6149. trapSeverity,
  6150. sysName,
  6151. vrcMainLabel
  6152. }
  6153. STATUS current
  6154. DESCRIPTION "VRC out-fan speed trap"
  6155. ::= { trapPrefix 13002 }
  6156.  
  6157. vrcOutFanPtSpeedCLEAR NOTIFICATION-TYPE
  6158. OBJECTS {
  6159. vrcOutFanPtSpeed,
  6160. trapThreshType,
  6161. trapSeverity,
  6162. sysName,
  6163. vrcMainLabel
  6164. }
  6165. STATUS current
  6166. DESCRIPTION "VRC out-fan speed clear trap"
  6167. ::= { trapPrefix 23002 }
  6168.  
  6169. --#####vrcOutFanCfgTable#####--
  6170.  
  6171. --#####vrcInFanPtTable#####--
  6172.  
  6173. --#####vrcInFanCfgTable#####--
  6174.  
  6175. --#####vrcCompPtTable#####--
  6176.  
  6177. vrcCompPtCapacityNOTIFY NOTIFICATION-TYPE
  6178. OBJECTS {
  6179. vrcCompPtCapacity,
  6180. trapThreshType,
  6181. trapSeverity,
  6182. sysName,
  6183. vrcMainLabel
  6184. }
  6185. STATUS current
  6186. DESCRIPTION "VRC compressor capacity trap"
  6187. ::= { trapPrefix 13003 }
  6188.  
  6189. vrcCompPtCapacityCLEAR NOTIFICATION-TYPE
  6190. OBJECTS {
  6191. vrcCompPtCapacity,
  6192. trapThreshType,
  6193. trapSeverity,
  6194. sysName,
  6195. vrcMainLabel
  6196. }
  6197. STATUS current
  6198. DESCRIPTION "VRC compressor capacity clear trap"
  6199. ::= { trapPrefix 23003 }
  6200.  
  6201. --#####vrcCompCfgTable#####--
  6202.  
  6203. --#####vrcReturnPtTable#####--
  6204.  
  6205. vrcReturnPtTempNOTIFY NOTIFICATION-TYPE
  6206. OBJECTS {
  6207. vrcReturnPtTemp,
  6208. temperatureUnits,
  6209. trapThreshType,
  6210. trapSeverity,
  6211. sysName,
  6212. vrcMainLabel
  6213. }
  6214. STATUS current
  6215. DESCRIPTION "VRC return temperature trap"
  6216. ::= { trapPrefix 13004 }
  6217.  
  6218. vrcReturnPtTempCLEAR NOTIFICATION-TYPE
  6219. OBJECTS {
  6220. vrcReturnPtTemp,
  6221. temperatureUnits,
  6222. trapThreshType,
  6223. trapSeverity,
  6224. sysName,
  6225. vrcMainLabel
  6226. }
  6227. STATUS current
  6228. DESCRIPTION "VRC return temperature clear trap"
  6229. ::= { trapPrefix 23004 }
  6230.  
  6231. --#####vrcReturnCfgTable#####--
  6232.  
  6233. --#####vrcSupplyPtTable#####--
  6234.  
  6235. vrcSupplyPtTempNOTIFY NOTIFICATION-TYPE
  6236. OBJECTS {
  6237. vrcSupplyPtTemp,
  6238. temperatureUnits,
  6239. trapThreshType,
  6240. trapSeverity,
  6241. sysName,
  6242. vrcMainLabel
  6243. }
  6244. STATUS current
  6245. DESCRIPTION "VRC supply temperature trap"
  6246. ::= { trapPrefix 13005 }
  6247.  
  6248. vrcSupplyPtTempCLEAR NOTIFICATION-TYPE
  6249. OBJECTS {
  6250. vrcSupplyPtTemp,
  6251. temperatureUnits,
  6252. trapThreshType,
  6253. trapSeverity,
  6254. sysName,
  6255. vrcMainLabel
  6256. }
  6257. STATUS current
  6258. DESCRIPTION "VRC supply temperature clear trap"
  6259. ::= { trapPrefix 23005 }
  6260.  
  6261. --#####vrcSupplyCfgTable#####--
  6262.  
  6263. --#####vrcPowerPtTable#####--
  6264.  
  6265. vrcPowerPtVoltageNOTIFY NOTIFICATION-TYPE
  6266. OBJECTS {
  6267. vrcPowerPtVoltage,
  6268. trapThreshType,
  6269. trapSeverity,
  6270. sysName,
  6271. vrcMainLabel
  6272. }
  6273. STATUS current
  6274. DESCRIPTION "VRC power voltage trap"
  6275. ::= { trapPrefix 13006 }
  6276.  
  6277. vrcPowerPtVoltageCLEAR NOTIFICATION-TYPE
  6278. OBJECTS {
  6279. vrcPowerPtVoltage,
  6280. trapThreshType,
  6281. trapSeverity,
  6282. sysName,
  6283. vrcMainLabel
  6284. }
  6285. STATUS current
  6286. DESCRIPTION "VRC power voltage clear trap"
  6287. ::= { trapPrefix 23006 }
  6288.  
  6289. vrcPowerPtFrequencyNOTIFY NOTIFICATION-TYPE
  6290. OBJECTS {
  6291. vrcPowerPtFrequency,
  6292. trapThreshType,
  6293. trapSeverity,
  6294. sysName,
  6295. vrcMainLabel
  6296. }
  6297. STATUS current
  6298. DESCRIPTION "VRC power frequency trap"
  6299. ::= { trapPrefix 13007 }
  6300.  
  6301. vrcPowerPtFrequencyCLEAR NOTIFICATION-TYPE
  6302. OBJECTS {
  6303. vrcPowerPtFrequency,
  6304. trapThreshType,
  6305. trapSeverity,
  6306. sysName,
  6307. vrcMainLabel
  6308. }
  6309. STATUS current
  6310. DESCRIPTION "VRC power frequency clear trap"
  6311. ::= { trapPrefix 23007 }
  6312.  
  6313. --#####vrcPowerCfgTable#####--
  6314.  
  6315. --#####vrcOutdoorPtTable#####--
  6316.  
  6317. vrcOutdoorPtTempNOTIFY NOTIFICATION-TYPE
  6318. OBJECTS {
  6319. vrcOutdoorPtTemp,
  6320. temperatureUnits,
  6321. trapThreshType,
  6322. trapSeverity,
  6323. sysName,
  6324. vrcMainLabel
  6325. }
  6326. STATUS current
  6327. DESCRIPTION "VRC outdoor temperature trap"
  6328. ::= { trapPrefix 13008 }
  6329.  
  6330. vrcOutdoorPtTempCLEAR NOTIFICATION-TYPE
  6331. OBJECTS {
  6332. vrcOutdoorPtTemp,
  6333. temperatureUnits,
  6334. trapThreshType,
  6335. trapSeverity,
  6336. sysName,
  6337. vrcMainLabel
  6338. }
  6339. STATUS current
  6340. DESCRIPTION "VRC outdoor temperature clear trap"
  6341. ::= { trapPrefix 23008 }
  6342.  
  6343. --#####vrcDischPtTable#####--
  6344.  
  6345. vrcDischPtTempNOTIFY NOTIFICATION-TYPE
  6346. OBJECTS {
  6347. vrcDischPtTemp,
  6348. temperatureUnits,
  6349. trapThreshType,
  6350. trapSeverity,
  6351. sysName,
  6352. vrcMainLabel
  6353. }
  6354. STATUS current
  6355. DESCRIPTION "VRC discharge temperature trap"
  6356. ::= { trapPrefix 13009 }
  6357.  
  6358. vrcDischPtTempCLEAR NOTIFICATION-TYPE
  6359. OBJECTS {
  6360. vrcDischPtTemp,
  6361. temperatureUnits,
  6362. trapThreshType,
  6363. trapSeverity,
  6364. sysName,
  6365. vrcMainLabel
  6366. }
  6367. STATUS current
  6368. DESCRIPTION "VRC discharge temperature clear trap"
  6369. ::= { trapPrefix 23009 }
  6370.  
  6371. vrcDischPtPressureNOTIFY NOTIFICATION-TYPE
  6372. OBJECTS {
  6373. vrcDischPtPressure,
  6374. trapThreshType,
  6375. trapSeverity,
  6376. sysName,
  6377. vrcMainLabel
  6378. }
  6379. STATUS current
  6380. DESCRIPTION "VRC discharge pressure trap"
  6381. ::= { trapPrefix 13010 }
  6382.  
  6383. vrcDischPtPressureCLEAR NOTIFICATION-TYPE
  6384. OBJECTS {
  6385. vrcDischPtPressure,
  6386. trapThreshType,
  6387. trapSeverity,
  6388. sysName,
  6389. vrcMainLabel
  6390. }
  6391. STATUS current
  6392. DESCRIPTION "VRC discharge pressure clear trap"
  6393. ::= { trapPrefix 23010 }
  6394.  
  6395. --#####vrcDischCfgTable#####--
  6396.  
  6397. --#####vrcSuctPtTable#####--
  6398.  
  6399. vrcSuctPtTempNOTIFY NOTIFICATION-TYPE
  6400. OBJECTS {
  6401. vrcSuctPtTemp,
  6402. temperatureUnits,
  6403. trapThreshType,
  6404. trapSeverity,
  6405. sysName,
  6406. vrcMainLabel
  6407. }
  6408. STATUS current
  6409. DESCRIPTION "VRC suction temperature trap"
  6410. ::= { trapPrefix 13011 }
  6411.  
  6412. vrcSuctPtTempCLEAR NOTIFICATION-TYPE
  6413. OBJECTS {
  6414. vrcSuctPtTemp,
  6415. temperatureUnits,
  6416. trapThreshType,
  6417. trapSeverity,
  6418. sysName,
  6419. vrcMainLabel
  6420. }
  6421. STATUS current
  6422. DESCRIPTION "VRC suction temperature clear trap"
  6423. ::= { trapPrefix 23011 }
  6424.  
  6425. vrcSuctPtPressureNOTIFY NOTIFICATION-TYPE
  6426. OBJECTS {
  6427. vrcSuctPtPressure,
  6428. trapThreshType,
  6429. trapSeverity,
  6430. sysName,
  6431. vrcMainLabel
  6432. }
  6433. STATUS current
  6434. DESCRIPTION "VRC suction pressure trap"
  6435. ::= { trapPrefix 13012 }
  6436.  
  6437. vrcSuctPtPressureCLEAR NOTIFICATION-TYPE
  6438. OBJECTS {
  6439. vrcSuctPtPressure,
  6440. trapThreshType,
  6441. trapSeverity,
  6442. sysName,
  6443. vrcMainLabel
  6444. }
  6445. STATUS current
  6446. DESCRIPTION "VRC suction pressure clear trap"
  6447. ::= { trapPrefix 23012 }
  6448.  
  6449. --#####vrcSuctCfgTable#####--
  6450.  
  6451. --###########################################################################################--
  6452. --common group--
  6453. --###########################################################################################--
  6454.  
  6455. common OBJECT IDENTIFIER ::= { vertiv 42 }
  6456.  
  6457. identity OBJECT IDENTIFIER ::= { common 1 }
  6458.  
  6459. i03 OBJECT-IDENTITY
  6460. STATUS current
  6461. DESCRIPTION
  6462. "Value given for sysObjectID on IMD3 units"