  1. smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.15.0-pimp-cheesesteak] (local build)
  2. 2 Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  3. 3
  4. 4 === START OF INFORMATION SECTION ===
  5. 5 Device Model: PNY CS900 240GB SSD
  6. 6 Serial Number: PNY43172231060106709
  7. 7 LU WWN Device Id: 5 f8db4c 431706709
  8. 8 Firmware Version: CS900211
  9. 9 User Capacity: 240,057,409,536 bytes [240 GB]
  10. 10 Sector Size: 512 bytes logical/physical
  11. 11 Rotation Rate: Solid State Device
  12. 12 Form Factor: 2.5 inches
  13. 13 Device is: Not in smartctl database [for details use: -P showall]
  14. 14 ATA Version is: Unknown(0x0ff8) (minor revision not indicated)
  15. 15 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
  16. 16 Local Time is: Thu Apr 19 20:44:51 2018 EDT
  17. 17 SMART support is: Available - device has SMART capability.
  18. 18 SMART support is: Enabled
  19. 19
  20. 20 === START OF READ SMART DATA SECTION ===
  21. 21 SMART overall-health self-assessment test result: PASSED
  22. 22
  23. 23 General SMART Values:
  24. 24 Offline data collection status: (0x00) Offline data collection activity
  25. 25 was never started.
  26. 26 Auto Offline Data Collection: Disabled.
  27. 27 Self-test execution status: ( 0) The previous self-test routine completed
  28. 28 without error or no self-test has ever
  29. 29 been run.
  30. 30 Total time to complete Offline
  31. 31 data collection: (65535) seconds.
  32. 32 Offline data collection
  33. 33 capabilities: (0x79) SMART execute Offline immediate.
  34. 34 No Auto Offline data collection support.
  35. 35 Suspend Offline collection upon new
  36. 36 command.
  37. 37 Offline surface scan supported.
  38. 38 Self-test supported.
  39. 39 Conveyance Self-test supported.
  40. 40 Selective Self-test supported.
  41. 41 SMART capabilities: (0x0003) Saves SMART data before entering
  42. 42 power-saving mode.
  43. 43 Supports SMART auto save timer.
  44. 44 Error logging capability: (0x01) Error logging supported.
  45. 45 General Purpose Logging supported.
  46. 46 Short self-test routine
  47. 47 recommended polling time: ( 2) minutes.
  48. 48 Extended self-test routine
  49. 49 recommended polling time: ( 30) minutes.
  50. 50 Conveyance self-test routine
  51. 51 recommended polling time: ( 6) minutes.
  52. 52
  53. 53 SMART Attributes Data Structure revision number: 16
  54. 54 Vendor Specific SMART Attributes with Thresholds:
  55. 55 ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  56. 56 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
  57. 57 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 446
  58. 58 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 25
  59. 59 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0
  60. 60 170 Unknown_Attribute 0x0003 088 088 010 Pre-fail Always - 133
  61. 61 173 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 131077
  62. 62 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 21
  63. 63 194 Temperature_Celsius 0x0023 067 067 000 Pre-fail Always - 33 (Min/Max 33/33)
  64. 64 218 Unknown_Attribute 0x000b 100 100 050 Pre-fail Always - 0
  65. 65 231 Temperature_Celsius 0x0013 100 100 000 Pre-fail Always - 99
  66. 66 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 413
  67. 67
  68. 68 SMART Error Log Version: 1
  69. 69 No Errors Logged
  70. 70
  71. 71 SMART Self-test log structure revision number 1
  72. 72 No self-tests have been logged. [To run self-tests, use: smartctl -t]
  73. 73
  74. 74 SMART Selective self-test log data structure revision number 0
  75. 75 Note: revision number not 1 implies that no selective self-test has ever been run
  76. 76 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  77. 77 1 0 0 Not_testing
  78. 78 2 0 0 Not_testing
  79. 79 3 0 0 Not_testing
  80. 80 4 0 0 Not_testing
Advertisement