Advertisement
Guest User

Untitled

a guest
Apr 20th, 2017
230
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 10.13 KB | None | 0 0
  1. === START OF INFORMATION SECTION ===
  2. Model Family: HGST Travelstar 7K1000
  3. Device Model: HGST HTS721010A9E630
  4. Serial Number: JR100X6P2HSKKE
  5. LU WWN Device Id: 5 000cca 7dce3590a
  6. Firmware Version: JB0OA3J0
  7. User Capacity: 1,000,204,886,016 bytes [1.00 TB]
  8. Sector Sizes: 512 bytes logical, 4096 bytes physical
  9. Rotation Rate: 7200 rpm
  10. Form Factor: 2.5 inches
  11. Device is: In smartctl database [for details use: -P show]
  12. ATA Version is: ATA8-ACS T13/1699-D revision 6
  13. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  14. Local Time is: Thu Apr 20 09:59:06 2017 PDT
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x00) Offline data collection activity
  23. was never started.
  24. Auto Offline Data Collection: Disabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26.  
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: ( 45) seconds.
  31. Offline data collection
  32. capabilities: (0x5b) SMART execute Offline immediate.
  33. Auto Offline data collection on/off supp
  34. ort.
  35. Suspend Offline collection upon new
  36. command.
  37. Offline surface scan supported.
  38. Self-test supported.
  39. No Conveyance Self-test supported.
  40. Selective Self-test supported.
  41. SMART capabilities: (0x0003) Saves SMART data before entering
  42. power-saving mode.
  43. Supports SMART auto save timer.
  44. Error logging capability: (0x01) Error logging supported.
  45. General Purpose Logging supported.
  46. Short self-test routine
  47. recommended polling time: ( 2) minutes.
  48. Extended self-test routine
  49. recommended polling time: ( 180) minutes.
  50. SCT capabilities: (0x003d) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
  58. FAILED RAW_VALUE
  59. 1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always -
  60. 0
  61. 2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline -
  62. 0
  63. 3 Spin_Up_Time 0x0007 143 143 033 Pre-fail Always -
  64. 2
  65. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always -
  66. 764
  67. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always -
  68. 0
  69. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always -
  70. 0
  71. 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline -
  72. 0
  73. 9 Power_On_Hours 0x0012 071 071 000 Old_age Always -
  74. 12899
  75. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always -
  76. 0
  77. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always -
  78. 760
  79. 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always -
  80. 0
  81. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always -
  82. 59
  83. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always -
  84. 990
  85. 194 Temperature_Celsius 0x0002 162 162 000 Old_age Always -
  86. 37 (Min/Max 16/82)
  87. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always -
  88. 0
  89. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always -
  90. 0
  91. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline -
  92. 0
  93. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always -
  94. 0
  95. 223 Load_Retry_Count 0x000a 100 100 000 Old_age Always -
  96. 0
  97.  
  98. SMART Error Log Version: 1
  99. ATA Error Count: 109 (device log contains only the most recent five errors)
  100. CR = Command Register [HEX]
  101. FR = Features Register [HEX]
  102. SC = Sector Count Register [HEX]
  103. SN = Sector Number Register [HEX]
  104. CL = Cylinder Low Register [HEX]
  105. CH = Cylinder High Register [HEX]
  106. DH = Device/Head Register [HEX]
  107. DC = Device Command Register [HEX]
  108. ER = Error register [HEX]
  109. ST = Status register [HEX]
  110. Powered_Up_Time is measured from power on, and printed as
  111. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  112. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  113.  
  114. Error 109 occurred at disk power-on lifetime: 12885 hours (536 days + 21 hours)
  115. When the command that caused the error occurred, the device was active or idle
  116. .
  117.  
  118. After command completion occurred, registers were:
  119. ER ST SC SN CL CH DH
  120. -- -- -- -- -- -- --
  121. 40 51 01 4f af 24 00 Error: WP at LBA = 0x0024af4f = 2404175
  122.  
  123. Commands leading to the command that caused the error were:
  124. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  125. -- -- -- -- -- -- -- -- ---------------- --------------------
  126. 61 08 68 18 f6 95 40 00 6d+23:41:01.944 WRITE FPDMA QUEUED
  127. 61 08 60 10 f6 95 40 00 6d+23:41:01.944 WRITE FPDMA QUEUED
  128. 60 01 58 4f af 24 40 00 6d+23:41:01.775 READ FPDMA QUEUED
  129. 61 40 50 c0 96 ff 40 00 6d+23:41:01.775 WRITE FPDMA QUEUED
  130. 2f 00 01 10 00 00 28 00 6d+23:41:01.766 READ LOG EXT
  131.  
  132. Error 108 occurred at disk power-on lifetime: 12885 hours (536 days + 21 hours)
  133. When the command that caused the error occurred, the device was active or idle
  134. .
  135.  
  136. After command completion occurred, registers were:
  137. ER ST SC SN CL CH DH
  138. -- -- -- -- -- -- --
  139. 40 51 01 4e af 24 00 Error: WP at LBA = 0x0024af4e = 2404174
  140.  
  141. Commands leading to the command that caused the error were:
  142. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  143. -- -- -- -- -- -- -- -- ---------------- --------------------
  144. 61 40 48 80 96 ff 40 00 6d+23:40:59.176 WRITE FPDMA QUEUED
  145. 60 08 40 30 4b b5 40 00 6d+23:40:58.842 READ FPDMA QUEUED
  146. 60 08 38 38 4b b5 40 00 6d+23:40:58.841 READ FPDMA QUEUED
  147. 60 01 30 4e af 24 40 00 6d+23:40:58.841 READ FPDMA QUEUED
  148. 61 08 28 78 ef 6f 40 00 6d+23:40:58.826 WRITE FPDMA QUEUED
  149.  
  150. Error 107 occurred at disk power-on lifetime: 12885 hours (536 days + 21 hours)
  151. When the command that caused the error occurred, the device was active or idle
  152. .
  153.  
  154. After command completion occurred, registers were:
  155. ER ST SC SN CL CH DH
  156. -- -- -- -- -- -- --
  157. 40 51 01 4d af 24 00 Error: UNC at LBA = 0x0024af4d = 2404173
  158.  
  159. Commands leading to the command that caused the error were:
  160. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  161. -- -- -- -- -- -- -- -- ---------------- --------------------
  162. 60 08 20 d8 4a b5 40 00 6d+23:40:55.903 READ FPDMA QUEUED
  163. 60 08 18 e8 4a b5 40 00 6d+23:40:55.899 READ FPDMA QUEUED
  164. 60 01 10 4d af 24 40 00 6d+23:40:55.899 READ FPDMA QUEUED
  165. 61 40 08 00 97 ff 40 00 6d+23:40:55.876 WRITE FPDMA QUEUED
  166. 60 08 f8 e0 4a b5 40 00 6d+23:40:55.876 READ FPDMA QUEUED
  167.  
  168. Error 106 occurred at disk power-on lifetime: 12885 hours (536 days + 21 hours)
  169. When the command that caused the error occurred, the device was active or idle
  170. .
  171.  
  172. After command completion occurred, registers were:
  173. ER ST SC SN CL CH DH
  174. -- -- -- -- -- -- --
  175. 40 51 01 4c af 24 00 Error: UNC at LBA = 0x0024af4c = 2404172
  176.  
  177. Commands leading to the command that caused the error were:
  178. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  179. -- -- -- -- -- -- -- -- ---------------- --------------------
  180. 60 01 00 4c af 24 40 00 6d+23:40:52.954 READ FPDMA QUEUED
  181. 60 08 f8 e0 4a b5 40 00 6d+23:40:52.954 READ FPDMA QUEUED
  182. 61 40 f0 c0 96 ff 40 00 6d+23:40:52.954 WRITE FPDMA QUEUED
  183. ea 00 00 00 00 00 00 00 6d+23:40:52.900 FLUSH CACHE EXT
  184. 60 08 c0 08 d5 bb 40 00 6d+23:40:52.876 READ FPDMA QUEUED
  185.  
  186. Error 105 occurred at disk power-on lifetime: 12885 hours (536 days + 21 hours)
  187. When the command that caused the error occurred, the device was active or idle
  188. .
  189.  
  190. After command completion occurred, registers were:
  191. ER ST SC SN CL CH DH
  192. -- -- -- -- -- -- --
  193. 40 51 01 4b af 24 00 Error: WP at LBA = 0x0024af4b = 2404171
  194.  
  195. Commands leading to the command that caused the error were:
  196. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  197. -- -- -- -- -- -- -- -- ---------------- --------------------
  198. 61 08 e0 20 e2 7b 40 00 6d+23:40:49.953 WRITE FPDMA QUEUED
  199. 61 f8 d8 c0 5b 7d 40 00 6d+23:40:49.953 WRITE FPDMA QUEUED
  200. 61 08 d0 98 b0 d8 40 00 6d+23:40:49.952 WRITE FPDMA QUEUED
  201. 60 01 c8 4b af 24 40 00 6d+23:40:49.952 READ FPDMA QUEUED
  202. 60 08 c0 08 d5 bb 40 00 6d+23:40:49.952 READ FPDMA QUEUED
  203.  
  204. SMART Self-test log structure revision number 1
  205. Num Test_Description Status Remaining LifeTime(hours) LBA
  206. _of_first_error
  207. # 1 Short offline Completed without error 00% 12884 -
  208.  
  209. SMART Selective self-test log data structure revision number 1
  210. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  211. 1 0 0 Not_testing
  212. 2 0 0 Not_testing
  213. 3 0 0 Not_testing
  214. 4 0 0 Not_testing
  215. 5 0 0 Not_testing
  216. Selective self-test flags (0x0):
  217. After scanning selected spans, do NOT read-scan remainder of disk.
  218. If Selective self-test is pending on power-up, resume after 0 minute delay.