- WORKING
- kdjoyce@ThinkPad-X390:~$ sudo tlp-stat -b
- [sudo] password for kdjoyce:
- --- TLP 1.6.1 --------------------------------------------
- +++ Battery Care
- Plugin: thinkpad
- Supported features: charge thresholds, recalibration
- Driver usage:
- * natacpi (thinkpad_acpi) = active (charge thresholds, recalibration)
- Parameter value ranges:
- * START_CHARGE_THRESH_BAT0/1: 0(off)..96(default)..99
- * STOP_CHARGE_THRESH_BAT0/1: 1..100(default)
- +++ ThinkPad Battery Status: BAT0 (Main / Internal)
- /sys/class/power_supply/BAT0/manufacturer = SMP
- /sys/class/power_supply/BAT0/model_name = 02DL017
- /sys/class/power_supply/BAT0/cycle_count = 226
- /sys/class/power_supply/BAT0/energy_full_design = 48010 [mWh]
- /sys/class/power_supply/BAT0/energy_full = 42390 [mWh]
- /sys/class/power_supply/BAT0/energy_now = 40090 [mWh]
- /sys/class/power_supply/BAT0/power_now = 11438 [mW]
- /sys/class/power_supply/BAT0/status = Charging
- /sys/class/power_supply/BAT0/charge_control_start_threshold = 94 [%]
- /sys/class/power_supply/BAT0/charge_control_end_threshold = 100 [%]
- /sys/class/power_supply/BAT0/charge_behaviour = [auto] inhibit-charge force-discharge
- Charge = 94.6 [%]
- Capacity = 88.3 [%]
- -
- NOT WORKING
- kdjoyce@ThinkPad-X390:~$ sudo tlp-stat -b
- --- TLP 1.6.1 --------------------------------------------
- +++ Battery Care
- Plugin: thinkpad
- Supported features: charge thresholds, recalibration
- Driver usage:
- * natacpi (thinkpad_acpi) = active (charge thresholds, recalibration)
- Parameter value ranges:
- * START_CHARGE_THRESH_BAT0/1: 0(off)..96(default)..99
- * STOP_CHARGE_THRESH_BAT0/1: 1..100(default)
- +++ ThinkPad Battery Status: BAT0 (Main / Internal)
- /sys/class/power_supply/BAT0/manufacturer = SMP
- /sys/class/power_supply/BAT0/model_name = 02DL017
- /sys/class/power_supply/BAT0/cycle_count = 226
- /sys/class/power_supply/BAT0/energy_full_design = 48010 [mWh]
- /sys/class/power_supply/BAT0/energy_full = 42360 [mWh]
- /sys/class/power_supply/BAT0/energy_now = 42070 [mWh]
- /sys/class/power_supply/BAT0/power_now = 0 [mW]
- /sys/class/power_supply/BAT0/status = Not charging
- /sys/class/power_supply/BAT0/charge_control_start_threshold = 94 [%]
- /sys/class/power_supply/BAT0/charge_control_end_threshold = 100 [%]
- /sys/class/power_supply/BAT0/charge_behaviour = [auto] inhibit-charge force-discharge
- Charge = 99.3 [%]
- Capacity = 88.2 [%]