Guest User

heiman

a guest
Nov 30th, 2018
116
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 2.70 KB | None | 0 0
  1. cc-znp:AREQ <-- AF:incomingMsg, { groupid: 0, clusterid: 1280, srcaddr: 53869, srcendpoint: 1, dstendpoint: 1, wasbroadcast: 0, linkquality: 136, securityuse: 0, timestamp: 4594613, transseqnumber: 0, len: 9, data: <Buffer 19 00 00 21 00 00 17 00 00> } +7ms
  2. zigbee-shepherd:af dispatchIncomingMsg(): type: incomingMsg, msg: [object Object] +2ms
  3. zigbee-shepherd:msgHdlr IND <-- AF:incomingMsg, transId: 0 +16ms
  4. serialport:unixRead waiting for readable because of code: EAGAIN +22ms
  5. serialport:poller Polling for "readable" +40ms
  6. zigbee-shepherd:af dispatchIncomingMsg(): type: zclIncomingMsg, msg: [object Object] +3ms
  7. zigbee2mqtt:warn 2018-11-30 19:11:59 No converter available for 'HS1SA' with cid 'ssIasZone', type 'statusChange' and data '{"cid":"ssIasZone","zoneStatus":33}'
  8. zigbee2mqtt:warn 2018-11-30 19:11:59 Please see: https://github.com/Koenkk/zigbee2mqtt/wiki/How-to-support-new-devices.
  9. serialport:poller received "readable" +1s
  10. serialport:bindings read +1s
  11. serialport:unixRead Starting read +1s
  12. serialport:unixRead Finished read 34 bytes +0ms
  13. serialport:main binding.read finished +1s
  14. cc-znp { sof: 254,
  15. cc-znp len: 29,
  16. cc-znp type: 'AREQ',
  17. cc-znp subsys: 'AF',
  18. cc-znp cmd: 'incomingMsg',
  19. cc-znp payload:
  20. cc-znp { groupid: 0,
  21. cc-znp clusterid: 1280,
  22. cc-znp srcaddr: 53869,
  23. cc-znp srcendpoint: 1,
  24. cc-znp dstendpoint: 1,
  25. cc-znp wasbroadcast: 0,
  26. cc-znp linkquality: 136,
  27. cc-znp securityuse: 0,
  28. cc-znp timestamp: 4598291,
  29. cc-znp transseqnumber: 0,
  30. cc-znp len: 9,
  31. cc-znp data: <Buffer 19 00 00 20 00 00 17 00 00> },
  32. cc-znp fcs: 30,
  33. cc-znp csum: 30 } +1s
  34. serialport:main _read reading +15ms
  35. serialport:bindings read +18ms
  36. serialport:unixRead Starting read +17ms
  37. cc-znp:AREQ <-- AF:incomingMsg, { groupid: 0, clusterid: 1280, srcaddr: 53869, srcendpoint: 1, dstendpoint: 1, wasbroadcast: 0, linkquality: 136, securityuse: 0, timestamp: 4598291, transseqnumber: 0, len: 9, data: <Buffer 19 00 00 20 00 00 17 00 00> } +5ms
  38. zigbee-shepherd:af dispatchIncomingMsg(): type: incomingMsg, msg: [object Object] +1ms
  39. zigbee-shepherd:msgHdlr IND <-- AF:incomingMsg, transId: 0 +9ms
  40. serialport:unixRead waiting for readable because of code: EAGAIN +12ms
  41. serialport:poller Polling for "readable" +30ms
  42. zigbee-shepherd:af dispatchIncomingMsg(): type: zclIncomingMsg, msg: [object Object] +2ms
  43. zigbee2mqtt:warn 2018-11-30 19:12:00 No converter available for 'HS1SA' with cid 'ssIasZone', type 'statusChange' and data '{"cid":"ssIasZone","zoneStatus":32}'
  44. zigbee2mqtt:warn 2018-11-30 19:12:00 Please see: https://github.com/Koenkk/zigbee2mqtt/wiki/How-to-support-new-devices