Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- cc-znp:AREQ <-- AF:incomingMsg, { groupid: 0, clusterid: 1280, srcaddr: 53869, srcendpoint: 1, dstendpoint: 1, wasbroadcast: 0, linkquality: 136, securityuse: 0, timestamp: 4594613, transseqnumber: 0, len: 9, data: <Buffer 19 00 00 21 00 00 17 00 00> } +7ms
- zigbee-shepherd:af dispatchIncomingMsg(): type: incomingMsg, msg: [object Object] +2ms
- zigbee-shepherd:msgHdlr IND <-- AF:incomingMsg, transId: 0 +16ms
- serialport:unixRead waiting for readable because of code: EAGAIN +22ms
- serialport:poller Polling for "readable" +40ms
- zigbee-shepherd:af dispatchIncomingMsg(): type: zclIncomingMsg, msg: [object Object] +3ms
- zigbee2mqtt:warn 2018-11-30 19:11:59 No converter available for 'HS1SA' with cid 'ssIasZone', type 'statusChange' and data '{"cid":"ssIasZone","zoneStatus":33}'
- zigbee2mqtt:warn 2018-11-30 19:11:59 Please see: https://github.com/Koenkk/zigbee2mqtt/wiki/How-to-support-new-devices.
- serialport:poller received "readable" +1s
- serialport:bindings read +1s
- serialport:unixRead Starting read +1s
- serialport:unixRead Finished read 34 bytes +0ms
- serialport:main binding.read finished +1s
- cc-znp { sof: 254,
- cc-znp len: 29,
- cc-znp type: 'AREQ',
- cc-znp subsys: 'AF',
- cc-znp cmd: 'incomingMsg',
- cc-znp payload:
- cc-znp { groupid: 0,
- cc-znp clusterid: 1280,
- cc-znp srcaddr: 53869,
- cc-znp srcendpoint: 1,
- cc-znp dstendpoint: 1,
- cc-znp wasbroadcast: 0,
- cc-znp linkquality: 136,
- cc-znp securityuse: 0,
- cc-znp timestamp: 4598291,
- cc-znp transseqnumber: 0,
- cc-znp len: 9,
- cc-znp data: <Buffer 19 00 00 20 00 00 17 00 00> },
- cc-znp fcs: 30,
- cc-znp csum: 30 } +1s
- serialport:main _read reading +15ms
- serialport:bindings read +18ms
- serialport:unixRead Starting read +17ms
- cc-znp:AREQ <-- AF:incomingMsg, { groupid: 0, clusterid: 1280, srcaddr: 53869, srcendpoint: 1, dstendpoint: 1, wasbroadcast: 0, linkquality: 136, securityuse: 0, timestamp: 4598291, transseqnumber: 0, len: 9, data: <Buffer 19 00 00 20 00 00 17 00 00> } +5ms
- zigbee-shepherd:af dispatchIncomingMsg(): type: incomingMsg, msg: [object Object] +1ms
- zigbee-shepherd:msgHdlr IND <-- AF:incomingMsg, transId: 0 +9ms
- serialport:unixRead waiting for readable because of code: EAGAIN +12ms
- serialport:poller Polling for "readable" +30ms
- zigbee-shepherd:af dispatchIncomingMsg(): type: zclIncomingMsg, msg: [object Object] +2ms
- zigbee2mqtt:warn 2018-11-30 19:12:00 No converter available for 'HS1SA' with cid 'ssIasZone', type 'statusChange' and data '{"cid":"ssIasZone","zoneStatus":32}'
- zigbee2mqtt:warn 2018-11-30 19:12:00 Please see: https://github.com/Koenkk/zigbee2mqtt/wiki/How-to-support-new-devices
Advertisement
Add Comment
Please, Sign In to add comment