Advertisement
Guest User

Untitled

a guest
Jul 8th, 2022
436
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 3.00 KB | None | 0 0
  1. > show interfaces terse xe-1/0/47
  2. Interface Admin Link Proto Local Remote
  3. xe-1/0/47 up up
  4. xe-1/0/47.0 up up inet 172.30.30.1/30
  5.  
  6. > show interfaces diagnostics optics xe-1/0/47
  7. Physical interface: xe-1/0/47
  8. Laser bias current : 85.664 mA
  9. Laser output power : 0.0000 mW / - Inf dBm
  10. Module temperature : 44 degrees C / 112 degrees F
  11. Module voltage : 3.2250 V
  12. Laser receiver power : 0.0776 mW / -11.10 dBm
  13. Laser bias current high alarm : Off
  14. Laser bias current low alarm : Off
  15. Laser bias current high warning : Off
  16. Laser bias current low warning : Off
  17. Laser output power high alarm : Off
  18. Laser output power low alarm : Off
  19. Laser output power high warning : Off
  20. Laser output power low warning : Off
  21. Module temperature high alarm : Off
  22. Module temperature low alarm : Off
  23. Module temperature high warning : Off
  24. Module temperature low warning : Off
  25. Module voltage high alarm : Off
  26. Module voltage low alarm : Off
  27. Module voltage high warning : Off
  28. Module voltage low warning : Off
  29. Laser rx power high alarm : Off
  30. Laser rx power low alarm : Off
  31. Laser rx power high warning : Off
  32. Laser rx power low warning : Off
  33. Laser bias current high alarm threshold : 120.000 mA
  34. Laser bias current low alarm threshold : 20.000 mA
  35. Laser bias current high warning threshold : 100.000 mA
  36. Laser bias current low warning threshold : 30.000 mA
  37. Laser output power high alarm threshold : 5.0110 mW / 7.00 dBm
  38. Laser output power low alarm threshold : 0.6310 mW / -2.00 dBm
  39. Laser output power high warning threshold : 3.1620 mW / 5.00 dBm
  40. Laser output power low warning threshold : 1.0000 mW / 0.00 dBm
  41. Module temperature high alarm threshold : 80 degrees C / 176 degrees F
  42. Module temperature low alarm threshold : -10 degrees C / 14 degrees F
  43. Module temperature high warning threshold : 70 degrees C / 158 degrees F
  44. Module temperature low warning threshold : 0 degrees C / 32 degrees F
  45. Module voltage high alarm threshold : 3.600 V
  46. Module voltage low alarm threshold : 3.000 V
  47. Module voltage high warning threshold : 3.500 V
  48. Module voltage low warning threshold : 3.100 V
  49. Laser rx power high alarm threshold : 0.2512 mW / -6.00 dBm
  50. Laser rx power low alarm threshold : 0.0032 mW / -24.95 dBm
  51. Laser rx power high warning threshold : 0.1585 mW / -8.00 dBm
  52. Laser rx power low warning threshold : 0.0050 mW / -23.01 dBm