- smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.8.12-11-pve] (local build)
- Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Samsung based SSDs
- Device Model: SAMSUNG MZ7KM480HMHQ-00005
- Serial Number: S3F4NX0K306844
- LU WWN Device Id: 5 002538 c409e4106
- Firmware Version: GXM5104Q
- User Capacity: 480,103,981,056 bytes [480 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: Solid State Device
- Form Factor: 2.5 inches
- TRIM Command: Available, deterministic, zeroed
- Device is: In smartctl database 7.3/5319
- ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jun 10 13:58:42 2025 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x02) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 2100) seconds.
- Offline data collection
- capabilities: (0x53) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 35) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 1
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 5105
- 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 36
- 177 Wear_Leveling_Count 0x0013 099 099 005 Pre-fail Always - 15
- 179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
- 180 Unused_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 2752
- 181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
- 182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
- 183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
- 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
- 187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0032 070 056 000 Old_age Always - 30
- 194 Temperature_Celsius 0x0022 070 056 000 Old_age Always - 30 (Min/Max 20/44)
- 195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
- 202 Exception_Mode_Status 0x0033 100 100 010 Pre-fail Always - 0
- 235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 30
- 241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 13611951860
- 242 Total_LBAs_Read 0x0032 099 099 000 Old_age Always - 1223955063
- 243 SATA_Downshift_Ct 0x0032 100 100 000 Old_age Always - 0
- 244 Thermal_Throttle_St 0x0032 100 100 000 Old_age Always - 0
- 245 Timed_Workld_Media_Wear 0x0032 100 100 000 Old_age Always - 65535
- 246 Timed_Workld_RdWr_Ratio 0x0032 100 100 000 Old_age Always - 65535
- 247 Timed_Workld_Timer 0x0032 100 100 000 Old_age Always - 65535
- 251 NAND_Writes 0x0032 100 100 000 Old_age Always - 16640739328
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- 255 0 65535 Read_scanning was completed without error