- === START OF INFORMATION SECTION ===
- Device Model: MKNSSDTR1TB-3D
- Serial Number: MK1710301003A55F8
- Firmware Version: Q0518CS
- User Capacity: 1,024,209,543,168 bytes [1.02 TB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: Solid State Device
- Form Factor: 2.5 inches
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: ACS-3 (minor revision not indicated)
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Sun Nov 4 00:30:03 2018 EDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 0) seconds.
- Offline data collection
- capabilities: (0x71) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0002) Does not save SMART data before
- entering power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 10) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 1
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x0000 100 100 000 Old_age Offline - 0
- 5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline - 0
- 9 Power_On_Hours 0x0000 100 100 000 Old_age Offline - 1831
- 12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline - 1385
- 160 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
- 161 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 126
- 163 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 32
- 164 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 20078
- 165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 48
- 166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 1
- 167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 20
- 148 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 20005
- 149 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 331
- 150 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 170
- 151 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 307
- 159 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
- 168 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 1500
- 169 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 100
- 177 Wear_Leveling_Count 0x0000 100 100 050 Old_age Offline - 4
- 181 Program_Fail_Cnt_Total 0x0000 100 100 000 Old_age Offline - 0
- 182 Erase_Fail_Count_Total 0x0000 100 100 000 Old_age Offline - 0
- 192 Power-Off_Retract_Count 0x0000 100 100 000 Old_age Offline - 51
- 194 Temperature_Celsius 0x0000 100 100 000 Old_age Offline - 35
- 195 Hardware_ECC_Recovered 0x0000 100 100 000 Old_age Offline - 316794
- 196 Reallocated_Event_Count 0x0000 100 100 016 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0000 100 100 050 Old_age Offline - 3376
- 232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline - 100
- 241 Total_LBAs_Written 0x0000 100 100 000 Old_age Offline - 151383
- 242 Total_LBAs_Read 0x0000 100 100 000 Old_age Offline - 76609
- 245 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 722808
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- 6 0 65535 Read_scanning was never started
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.