  1. 10:30:23.507578 GW: 1
  2. 10:30:23.883507 T80190000 Read-Data Boiler water temperature: 0.00
  3. 10:30:24.864470 T80190000 Read-Data Boiler water temperature: 0.00
  4. 10:30:25.893651 T80190000 Read-Data Boiler water temperature: 0.00
  5. 10:30:26.018420 BC0194000 Read-Ack Boiler water temperature: 64.00
  6. 10:30:26.875499 T10010A00 Write-Data Control setpoint: 10.00
  7. 10:30:26.983976 BD0010A00 Write-Ack Control setpoint: 10.00
  8. 10:30:27.859351 T80640000 Read-Data Remote override function: 00000000
  9. 10:30:27.978621 Error 03
  10. 10:30:28.896307 T80000200 Read-Data Status: 00000010 00000000
  11. 10:30:28.954382 B40000200 Read-Ack Status: 00000010 00000000
  12. 10:30:29.875249 T80190000 Read-Data Boiler water temperature: 0.00
  13. 10:30:29.973310 BC0194000 Read-Ack Boiler water temperature: 64.00
  14. 10:30:30.871976 T10010A00 Write-Data Control setpoint: 10.00
  15. 10:30:30.967557 BD0010A00 Write-Ack Control setpoint: 10.00
  16. 10:30:31.897783 T80640000 Read-Data Remote override function: 00000000
  17. 10:30:32.877200 T80640000 Read-Data Remote override function: 00000000
  18. 10:30:32.964229 B70640000 Unk-DataId Remote override function: 00000000
  19. 10:30:32.973635 A40640000 Read-Ack Remote override function: 00000000
  20. 10:30:33.897693 T80190000 Read-Data Boiler water temperature: 0.00
  21. 10:30:34.003355 BC0194000 Read-Ack Boiler water temperature: 64.00
  22. 10:30:34.896713 T10010A00 Write-Data Control setpoint: 10.00
  23. 10:30:34.964646 BD0010A00 Write-Ack Control setpoint: 10.00
  24. 10:30:35.882747 T00110000 Read-Data Relative modulation level: 0.00
  25. 10:30:35.941192 BC0110000 Read-Ack Relative modulation level: 0.00
  26. 10:30:36.911160 T10181505 Write-Data Room temperature: 21.02
  27. 10:30:36.968612 BF0180000 Unk-DataId Room temperature: 0.00
  28. 10:30:37.888071 T90101480 Write-Data Room setpoint: 20.50
  29. 10:30:37.980996 B70100000 Unk-DataId Room setpoint: 0.00
  30. 10:30:37.983469 AD0100000 Write-Ack Room setpoint: 0.00
  31. 10:30:38.888976 T80000200 Read-Data Status: 00000010 00000000
  32. 10:30:38.938892 B40000200 Read-Ack Status: 00000010 00000000
  33. 10:30:39.903424 T80190000 Read-Data Boiler water temperature: 0.00
  34. 10:30:39.963714 BC0194000 Read-Ack Boiler water temperature: 64.00
  35. 10:30:40.887305 T10010A00 Write-Data Control setpoint: 10.00
  36. 10:30:41.006459 BD0010A00 Write-Ack Control setpoint: 10.00
  37. 10:30:41.869738 T00110000 Read-Data Relative modulation level: 0.00
  38. 10:30:41.977721 Error 03
  39. 10:30:42.899705 T00110000 Read-Data Relative modulation level: 0.00
  40. 10:30:43.009126 BC0110000 Read-Ack Relative modulation level: 0.00
  41. 10:30:43.889550 T80190000 Read-Data Boiler water temperature: 0.00
  42. 10:30:43.978917 BC0194000 Read-Ack Boiler water temperature: 64.00
  43. 10:30:44.868735 T10010A00 Write-Data Control setpoint: 10.00
  44. 10:30:44.929621 BD0010A00 Write-Ack Control setpoint: 10.00
  45. 10:30:45.895141 T10148A1E Write-Data Day of week and time of day: Thu 10:30
  46. 10:30:46.870696 T10148A1E Write-Data Day of week and time of day: Thu 10:30
  47. 10:30:46.979632 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  48. 10:30:46.983052 AD0148A1E Write-Ack Day of week and time of day: Thu 10:30
  49. 10:30:47.869865 T801C0000 Read-Data Return water temperature: 0.00
  50. 10:30:47.980102 BC01C2F00 Read-Ack Return water temperature: 47.00
  51. 10:30:48.864268 T80000200 Read-Data Status: 00000010 00000000
  52. 10:30:48.933062 B40000200 Read-Ack Status: 00000010 00000000
  53. 10:30:49.896162 T80190000 Read-Data Boiler water temperature: 0.00
  54. 10:30:49.991107 BC0194000 Read-Ack Boiler water temperature: 64.00
  55. 10:30:50.881102 T10010A00 Write-Data Control setpoint: 10.00
  56. 10:30:50.987635 BD0010A00 Write-Ack Control setpoint: 10.00
  57. 10:30:51.908465 T00110000 Read-Data Relative modulation level: 0.00
  58. 10:30:51.955623 BC0110000 Read-Ack Relative modulation level: 0.00
  59. 10:30:52.910007 T801A0000 Read-Data DHW temperature: 0.00
  60. 10:30:53.889774 T80190000 Read-Data Boiler water temperature: 0.00
  61. 10:30:53.962333 BC0194000 Read-Ack Boiler water temperature: 64.00
  62. 10:30:54.909810 T10010A00 Write-Data Control setpoint: 10.00
  63. 10:30:54.966858 BD0010A00 Write-Ack Control setpoint: 10.00
  64. 10:30:55.937625 T801A0000 Read-Data DHW temperature: 0.00
  65. 10:30:55.996715 Error 04
  66. 10:30:56.005324 EC05A3200
  67. 10:30:56.871760 T801A0000 Read-Data DHW temperature: 0.00
  68. 10:30:57.925948 T801A0000 Read-Data DHW temperature: 0.00
  69. 10:30:57.978487 BC01A3200 Read-Ack DHW temperature: 50.00
  70. 10:30:58.881585 T80000200 Read-Data Status: 00000010 00000000
  71. 10:30:58.990066 B40000200 Read-Ack Status: 00000010 00000000
  72. 10:30:59.896550 T80000200 Read-Data Status: 00000010 00000000
  73. 10:30:59.976806 B40000200 Read-Ack Status: 00000010 00000000
  74. 10:31:00.905900 T80190000 Read-Data Boiler water temperature: 0.00
  75. 10:31:01.012748 BC0194000 Read-Ack Boiler water temperature: 64.00
  76. 10:31:01.882778 T10010A00 Write-Data Control setpoint: 10.00
  77. 10:31:01.979769 BD0010A00 Write-Ack Control setpoint: 10.00
  78. 10:31:02.864291 T10383FFF Write-Data DHW setpoint: 64.00
  79. 10:31:02.976360 BD0383FFF Write-Ack DHW setpoint: 64.00
  80. 10:31:03.895600 T90395AFC Write-Data Max CH water setpoint: 90.98
  81. 10:31:04.004883 B50395AFC Write-Ack Max CH water setpoint: 90.98
  82. 10:31:04.891468 T80190000 Read-Data Boiler water temperature: 0.00
  83. 10:31:04.948865 BC0194000 Read-Ack Boiler water temperature: 64.00
  84. 10:31:05.870759 T10010A00 Write-Data Control setpoint: 10.00
  85. 10:31:05.931938 BD0010A00 Write-Ack Control setpoint: 10.00
  86. 10:31:06.899258 T00090000 Read-Data Remote override room setpoint: 0.00
  87. 10:31:06.958452 BF0090000 Unk-DataId Remote override room setpoint: 0.00
  88. 10:31:07.012224 AC0090000 Read-Ack Remote override room setpoint: 0.00
  89. 10:31:07.887204 T00090000 Read-Data Remote override room setpoint: 0.00
  90. 10:31:07.986143 BF0090000 Unk-DataId Remote override room setpoint: 0.00
  91. 10:31:07.989056 AC0090000 Read-Ack Remote override room setpoint: 0.00
  92. 10:31:08.862484 T00090000 Read-Data Remote override room setpoint: 0.00
  93. 10:31:08.971951 BF0090000 Unk-DataId Remote override room setpoint: 0.00
  94. 10:31:08.974510 AC0090000 Read-Ack Remote override room setpoint: 0.00
  95. 10:31:09.908109 T80000200 Read-Data Status: 00000010 00000000
  96. 10:31:10.025755 Error 03
  97. 10:31:10.892604 T80000200 Read-Data Status: 00000010 00000000
  98. 10:31:11.872370 T80000200 Read-Data Status: 00000010 00000000
  99. 10:31:11.930659 B40000200 Read-Ack Status: 00000010 00000000
  100. 10:31:12.897388 T80190000 Read-Data Boiler water temperature: 0.00
  101. 10:31:12.988876 BC0194000 Read-Ack Boiler water temperature: 64.00
  102. 10:31:13.883681 T10010A00 Write-Data Control setpoint: 10.00
  103. 10:31:13.943161 BD0010A00 Write-Ack Control setpoint: 10.00
  104. 10:31:14.862528 T80190000 Read-Data Boiler water temperature: 0.00
  105. 10:31:14.975913 BC0194000 Read-Ack Boiler water temperature: 64.00
  106. 10:31:15.898568 T10010A00 Write-Data Control setpoint: 10.00
  107. 10:31:16.002650 BD0010A00 Write-Ack Control setpoint: 10.00
  108. 10:31:16.876858 T80640000 Read-Data Remote override function: 00000000
  109. 10:31:16.987732 B70640000 Unk-DataId Remote override function: 00000000
  110. 10:31:16.997877 A40640000 Read-Ack Remote override function: 00000000
  111. 10:31:17.877084 T00110000 Read-Data Relative modulation level: 0.00
  112. 10:31:18.894683 T00110000 Read-Data Relative modulation level: 0.00
  113. 10:31:18.952338 BC0110000 Read-Ack Relative modulation level: 0.00
  114. 10:31:19.884062 T80000200 Read-Data Status: 00000010 00000000
  115. 10:31:19.976747 B40000200 Read-Ack Status: 00000010 00000000
  116. 10:31:20.896180 T80190000 Read-Data Boiler water temperature: 0.00
  117. 10:31:20.944470 Error 03
  118. 10:31:21.889399 T80190000 Read-Data Boiler water temperature: 0.00
  119. 10:31:21.949273 BC0194000 Read-Ack Boiler water temperature: 64.00
  120. 10:31:22.882085 T10010A00 Write-Data Control setpoint: 10.00
  121. 10:31:22.975108 BD0010A00 Write-Ack Control setpoint: 10.00
  122. 10:31:23.899897 T00110000 Read-Data Relative modulation level: 0.00
  123. 10:31:24.024504 Error 03
  124. 10:31:24.881547 T80190000 Read-Data Boiler water temperature: 0.00
  125. 10:31:25.867157 T80190000 Read-Data Boiler water temperature: 0.00
  126. 10:31:25.961069 BC0194000 Read-Ack Boiler water temperature: 64.00
  127. 10:31:26.905400 T10010A00 Write-Data Control setpoint: 10.00
  128. 10:31:26.967068 BD0010A00 Write-Ack Control setpoint: 10.00
  129. 10:31:27.887627 T00110000 Read-Data Relative modulation level: 0.00
  130. 10:31:28.002277 Error 03
  131. 10:31:28.913954 T00110000 Read-Data Relative modulation level: 0.00
  132. 10:31:29.007904 BC0110000 Read-Ack Relative modulation level: 0.00
  133. 10:31:29.897051 T80000200 Read-Data Status: 00000010 00000000
  134. 10:31:29.991666 B40000200 Read-Ack Status: 00000010 00000000
  135. 10:31:30.893664 T80190000 Read-Data Boiler water temperature: 0.00
  136. 10:31:30.988012 BC0194000 Read-Ack Boiler water temperature: 64.00
  137. 10:31:31.883531 T10010A00 Write-Data Control setpoint: 10.00
  138. 10:31:31.937755 BD0010A00 Write-Ack Control setpoint: 10.00
  139. 10:31:32.909918 T00110000 Read-Data Relative modulation level: 0.00
  140. 10:31:33.000787 BC0110000 Read-Ack Relative modulation level: 0.00
  141. 10:31:33.892026 T90181508 Write-Data Room temperature: 21.03
  142. 10:31:33.950586 BF0180000 Unk-DataId Room temperature: 0.00
  143. 10:31:34.871888 T80190000 Read-Data Boiler water temperature: 0.00
  144. 10:31:34.981264 Error 03
  145. 10:31:35.905446 T80190000 Read-Data Boiler water temperature: 0.00
  146. 10:31:35.996713 BC0194000 Read-Ack Boiler water temperature: 64.00
  147. 10:31:36.893507 T10010A00 Write-Data Control setpoint: 10.00
  148. 10:31:36.951315 BD0010A00 Write-Ack Control setpoint: 10.00
  149. 10:31:37.869489 T90101480 Write-Data Room setpoint: 20.50
  150. 10:31:37.965708 B70100000 Unk-DataId Room setpoint: 0.00
  151. 10:31:37.971380 AD0100000 Write-Ack Room setpoint: 0.00
  152. 10:31:38.899090 T10148A1E Write-Data Day of week and time of day: Thu 10:30
  153. 10:31:39.884030 T80000200 Read-Data Status: 00000010 00000000
  154. 10:31:39.940391 B40000200 Read-Ack Status: 00000010 00000000
  155. 10:31:40.859667 T80190000 Read-Data Boiler water temperature: 0.00
  156. 10:31:40.966899 BC0194000 Read-Ack Boiler water temperature: 64.00
  157. 10:31:41.907617 T10010A00 Write-Data Control setpoint: 10.00
  158. 10:31:41.968092 Error 03
  159. 10:31:42.886403 T10010A00 Write-Data Control setpoint: 10.00
  160. 10:31:43.903954 T10010A00 Write-Data Control setpoint: 10.00
  161. 10:31:43.965435 BD0010A00 Write-Ack Control setpoint: 10.00
  162. 10:31:44.911273 T80190000 Read-Data Boiler water temperature: 0.00
  163. 10:31:44.968280 BC0194000 Read-Ack Boiler water temperature: 64.00
  164. 10:31:45.872602 T10010A00 Write-Data Control setpoint: 10.00
  165. 10:31:45.980509 BD0010A00 Write-Ack Control setpoint: 10.00
  166. 10:31:46.905008 T00110000 Read-Data Relative modulation level: 0.00
  167. 10:31:47.000020 BC0110000 Read-Ack Relative modulation level: 0.00
  168. 10:31:47.898731 T90148A1F Write-Data Day of week and time of day: Thu 10:31
  169. 10:31:47.955151 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  170. 10:31:48.001172 A50148A1F Write-Ack Day of week and time of day: Thu 10:31
  171. 10:31:48.878243 T801C0000 Read-Data Return water temperature: 0.00
  172. 10:31:48.989524 B401C2E00 Read-Ack Return water temperature: 46.00
  173. 10:31:49.866320 T80000200 Read-Data Status: 00000010 00000000
  174. 10:31:50.892573 T80000200 Read-Data Status: 00000010 00000000
  175. 10:31:51.002014 B40000200 Read-Ack Status: 00000010 00000000
  176. 10:31:51.880367 T80190000 Read-Data Boiler water temperature: 0.00
  177. 10:31:51.994877 BC0194000 Read-Ack Boiler water temperature: 64.00
  178. 10:31:52.871041 T10010A00 Write-Data Control setpoint: 10.00
  179. 10:31:52.967544 BD0010A00 Write-Ack Control setpoint: 10.00
  180. 10:31:53.909463 T00110000 Read-Data Relative modulation level: 0.00
  181. 10:31:53.967510 BC0110000 Read-Ack Relative modulation level: 0.00
  182. 10:31:54.884450 T80190000 Read-Data Boiler water temperature: 0.00
  183. 10:31:54.993855 BC0194000 Read-Ack Boiler water temperature: 64.00
  184. 10:31:55.885503 T10010A00 Write-Data Control setpoint: 10.00
  185. 10:31:55.937484 BD0010A00 Write-Ack Control setpoint: 10.00
  186. 10:31:56.910458 T801A0000 Read-Data DHW temperature: 0.00
  187. 10:31:57.020629 BC01A3200 Read-Ack DHW temperature: 50.00
  188. 10:31:57.890494 T001B0000 Read-Data Outside temperature: 0.00
  189. 10:31:57.998523 B401BE0FF Read-Ack Outside temperature: -31.00
  190. 10:31:58.874131 T00120000 Read-Data CH water pressure: 0.00
  191. 10:31:58.945192 B40120166 Read-Ack CH water pressure: 1.40
  192. 10:31:59.869997 T80000200 Read-Data Status: 00000010 00000000
  193. 10:31:59.981773 Error 03
  194. 10:32:00.903036 T80000200 Read-Data Status: 00000010 00000000
  195. 10:32:00.960564 B40000260 Read-Ack Status: 00000010 01100000
  196. 10:32:01.878633 T80190000 Read-Data Boiler water temperature: 0.00
  197. 10:32:01.942143 BC0194000 Read-Ack Boiler water temperature: 64.00
  198. 10:32:02.910736 T10010A00 Write-Data Control setpoint: 10.00
  199. 10:32:02.970996 BD0010A00 Write-Ack Control setpoint: 10.00
  200. 10:32:03.905085 T10383FFF Write-Data DHW setpoint: 64.00
  201. 10:32:04.890603 T80190000 Read-Data Boiler water temperature: 0.00
  202. 10:32:04.958953 BC0194000 Read-Ack Boiler water temperature: 64.00
  203. 10:32:05.912039 T10010A00 Write-Data Control setpoint: 10.00
  204. 10:32:06.045003 BD0010A00 Write-Ack Control setpoint: 10.00
  205. 10:32:06.950875 T10383FFF Write-Data DHW setpoint: 64.00
  206. 10:32:06.952179 BD0383FFF Write-Ack DHW setpoint: 64.00
  207. 10:32:07.878940 T90395AFC Write-Data Max CH water setpoint: 90.98
  208. 10:32:07.935687 B50395AFC Write-Ack Max CH water setpoint: 90.98
  209. 10:32:08.898300 T00090000 Read-Data Remote override room setpoint: 0.00
  210. 10:32:08.898615 R00060000 Read-Data Remote parameter flags: 00000000 00000000
  211. 10:32:09.012760 B40060301 Read-Ack Remote parameter flags: 00000011 00000001
  212. 10:32:09.013468 AC0090000 Read-Ack Remote override room setpoint: 0.00
  213. 10:32:09.897922 T80000200 Read-Data Status: 00000010 00000000
  214. 10:32:09.998947 Error 03
  215. 10:32:10.879683 T80000200 Read-Data Status: 00000010 00000000
  216. 10:32:11.903292 T80000200 Read-Data Status: 00000010 00000000
  217. 10:32:11.999012 B40000200 Read-Ack Status: 00000010 00000000
  218. 10:32:12.886811 T80190000 Read-Data Boiler water temperature: 0.00
  219. 10:32:12.988177 BC0194000 Read-Ack Boiler water temperature: 64.00
  220. 10:32:13.876171 T10010A00 Write-Data Control setpoint: 10.00
  221. 10:32:13.985373 Error 03
  222. 10:32:14.908243 T80190000 Read-Data Boiler water temperature: 0.00
  223. 10:32:15.003894 BC0194000 Read-Ack Boiler water temperature: 64.00
  224. 10:32:15.893486 T10010A00 Write-Data Control setpoint: 10.00
  225. 10:32:15.986197 BD0010A00 Write-Ack Control setpoint: 10.00
  226. 10:32:16.890003 T80640000 Read-Data Remote override function: 00000000
  227. 10:32:16.943124 B70640000 Unk-DataId Remote override function: 00000000
  228. 10:32:16.945975 A40640000 Read-Ack Remote override function: 00000000
  229. 10:32:17.907110 T00110000 Read-Data Relative modulation level: 0.00
  230. 10:32:18.881427 T00110000 Read-Data Relative modulation level: 0.00
  231. 10:32:18.977362 BC0110000 Read-Ack Relative modulation level: 0.00
  232. 10:32:19.861692 T80000200 Read-Data Status: 00000010 00000000
  233. 10:32:19.974678 B40000200 Read-Ack Status: 00000010 00000000
  234. 10:32:20.904342 T80190000 Read-Data Boiler water temperature: 0.00
  235. 10:32:20.994788 BC0194000 Read-Ack Boiler water temperature: 64.00
  236. 10:32:21.878568 T10010A00 Write-Data Control setpoint: 10.00
  237. 10:32:21.986509 BD0010A00 Write-Ack Control setpoint: 10.00
  238. 10:32:22.874162 T00110000 Read-Data Relative modulation level: 0.00
  239. 10:32:22.972775 BC0110000 Read-Ack Relative modulation level: 0.00
  240. 10:32:23.898448 T90181508 Write-Data Room temperature: 21.03
  241. 10:32:24.022724 Error 04
  242. 10:32:24.028326 EF0180002
  243. 10:32:24.875717 T80190000 Read-Data Boiler water temperature: 0.00
  244. 10:32:25.916990 T80190000 Read-Data Boiler water temperature: 0.00
  245. 10:32:25.966370 BC0194000 Read-Ack Boiler water temperature: 64.00
  246. 10:32:26.898100 T10010A00 Write-Data Control setpoint: 10.00
  247. 10:32:26.952575 BD0010A00 Write-Ack Control setpoint: 10.00
  248. 10:32:27.869897 T90181508 Write-Data Room temperature: 21.03
  249. 10:32:27.970249 BF01BFFFF Unk-DataId Outside temperature: -0.00
  250. 10:32:28.870208 T90181508 Write-Data Room temperature: 21.03
  251. 10:32:29.902403 T80000200 Read-Data Status: 00000010 00000000
  252. 10:32:29.961277 B40000200 Read-Ack Status: 00000010 00000000
  253. 10:32:30.880567 T80190000 Read-Data Boiler water temperature: 0.00
  254. 10:32:30.946991 BC0194000 Read-Ack Boiler water temperature: 64.00
  255. 10:32:31.866461 T10010A00 Write-Data Control setpoint: 10.00
  256. 10:32:31.968460 BD0010A00 Write-Ack Control setpoint: 10.00
  257. 10:32:32.907120 T00110000 Read-Data Relative modulation level: 0.00
  258. 10:32:32.958934 BC0110000 Read-Ack Relative modulation level: 0.00
  259. 10:32:33.888445 T10181512 Write-Data Room temperature: 21.07
  260. 10:32:33.943301 BF0180000 Unk-DataId Room temperature: 0.00
  261. 10:32:34.879421 T80190000 Read-Data Boiler water temperature: 0.00
  262. 10:32:34.989851 Error 03
  263. 10:32:35.898572 T80190000 Read-Data Boiler water temperature: 0.00
  264. 10:32:35.967036 BC0194000 Read-Ack Boiler water temperature: 64.00
  265. 10:32:36.883443 T10010A00 Write-Data Control setpoint: 10.00
  266. 10:32:36.941640 BD0010A00 Write-Ack Control setpoint: 10.00
  267. 10:32:37.870770 T90101480 Write-Data Room setpoint: 20.50
  268. 10:32:37.928290 B70100000 Unk-DataId Room setpoint: 0.00
  269. 10:32:37.978949 AD0100000 Write-Ack Room setpoint: 0.00
  270. 10:32:38.908160 T90148A1F Write-Data Day of week and time of day: Thu 10:31
  271. 10:32:39.880077 T80000200 Read-Data Status: 00000010 00000000
  272. 10:32:39.994783 B40000200 Read-Ack Status: 00000010 00000000
  273. 10:32:40.872509 T80190000 Read-Data Boiler water temperature: 0.00
  274. 10:32:40.933050 BC0194000 Read-Ack Boiler water temperature: 64.00
  275. 10:32:41.893422 T10010A00 Write-Data Control setpoint: 10.00
  276. 10:32:41.995996 Error 04
  277. 10:32:42.000804 ED0810A00
  278. 10:32:42.865208 T10010A00 Write-Data Control setpoint: 10.00
  279. 10:32:43.901024 T10010A00 Write-Data Control setpoint: 10.00
  280. 10:32:44.000573 BD0010A00 Write-Ack Control setpoint: 10.00
  281. 10:32:44.892082 T80190000 Read-Data Boiler water temperature: 0.00
  282. 10:32:44.992157 BC0194000 Read-Ack Boiler water temperature: 64.00
  283. 10:32:45.868689 T10010A00 Write-Data Control setpoint: 10.00
  284. 10:32:45.969409 BD0010A00 Write-Ack Control setpoint: 10.00
  285. 10:32:46.904679 T00110000 Read-Data Relative modulation level: 0.00
  286. 10:32:47.006719 BC0110000 Read-Ack Relative modulation level: 0.00
  287. 10:32:47.887081 T90148A20 Write-Data Day of week and time of day: Thu 10:32
  288. 10:32:47.988322 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  289. 10:32:47.999310 A50148A20 Write-Ack Day of week and time of day: Thu 10:32
  290. 10:32:48.878890 T801C0000 Read-Data Return water temperature: 0.00
  291. 10:32:48.990987 Error 03
  292. 10:32:49.907058 T80000200 Read-Data Status: 00000010 00000000
  293. 10:32:49.971028 B40000200 Read-Ack Status: 00000010 00000000
  294. 10:32:50.888641 T80190000 Read-Data Boiler water temperature: 0.00
  295. 10:32:51.007571 BC0194000 Read-Ack Boiler water temperature: 64.00
  296. 10:32:51.877824 T10010A00 Write-Data Control setpoint: 10.00
  297. 10:32:51.976509 BD0010A00 Write-Ack Control setpoint: 10.00
  298. 10:32:52.858962 T00110000 Read-Data Relative modulation level: 0.00
  299. 10:32:52.979390 Error 03
  300. 10:32:53.900936 T00110000 Read-Data Relative modulation level: 0.00
  301. 10:32:53.949230 BC0110000 Read-Ack Relative modulation level: 0.00
  302. 10:32:54.876445 T80190000 Read-Data Boiler water temperature: 0.00
  303. 10:32:54.978265 BC0194000 Read-Ack Boiler water temperature: 64.00
  304. 10:32:55.912078 T10010A00 Write-Data Control setpoint: 10.00
  305. 10:32:56.032423 Error 03
  306. 10:32:56.882993 T10010A00 Write-Data Control setpoint: 10.00
  307. 10:32:57.871200 T10010A00 Write-Data Control setpoint: 10.00
  308. 10:32:57.964508 BD0010A00 Write-Ack Control setpoint: 10.00
  309. 10:32:58.910151 T801C0000 Read-Data Return water temperature: 0.00
  310. 10:32:58.957102 B401C2E00 Read-Ack Return water temperature: 46.00
  311. 10:32:59.905428 T80000200 Read-Data Status: 00000010 00000000
  312. 10:32:59.963802 B40000200 Read-Ack Status: 00000010 00000000
  313. 10:33:00.865240 T80000200 Read-Data Status: 00000010 00000000
  314. 10:33:00.932599 B40000200 Read-Ack Status: 00000010 00000000
  315. 10:33:01.903917 T80190000 Read-Data Boiler water temperature: 0.00
  316. 10:33:02.016982 Error 03
  317. 10:33:02.879932 T80190000 Read-Data Boiler water temperature: 0.00
  318. 10:33:02.939243 BC0194000 Read-Ack Boiler water temperature: 64.00
  319. 10:33:03.873249 T10010A00 Write-Data Control setpoint: 10.00
  320. 10:33:03.941754 BD0010A00 Write-Ack Control setpoint: 10.00
  321. 10:33:04.889284 T10383FFF Write-Data DHW setpoint: 64.00
  322. 10:33:05.011690 Error 03
  323. 10:33:05.862784 T80190000 Read-Data Boiler water temperature: 0.00
  324. 10:33:05.965280 BC0194000 Read-Ack Boiler water temperature: 64.00
  325. 10:33:06.904033 T10010A00 Write-Data Control setpoint: 10.00
  326. 10:33:07.009847 BD0010A00 Write-Ack Control setpoint: 10.00
  327. 10:33:07.884509 T10383FFF Write-Data DHW setpoint: 64.00
  328. 10:33:07.953829 Error 04
  329. 10:33:08.010977 E90383FFF
  330. 10:33:08.888514 T10383FFF Write-Data DHW setpoint: 64.00
  331. 10:33:08.956986 BD0383FFF Write-Ack DHW setpoint: 64.00
  332. 10:33:09.891318 T90395AFC Write-Data Max CH water setpoint: 90.98
  333. 10:33:10.007984 Error 03
  334. 10:33:10.920516 T80000200 Read-Data Status: 00000010 00000000
  335. 10:33:11.932493 T80000200 Read-Data Status: 00000010 00000000
  336. 10:33:11.979867 BC00002E0 Read-Ack Status: 00000010 11100000
  337. 10:33:12.896398 T80190000 Read-Data Boiler water temperature: 0.00
  338. 10:33:12.954105 BC0194000 Read-Ack Boiler water temperature: 64.00
  339. 10:33:13.887140 T10010A00 Write-Data Control setpoint: 10.00
  340. 10:33:13.970975 BD1FF0A00 Write-Ack Message ID 255: 2560
  341. 10:33:14.914906 T10010A00 Write-Data Control setpoint: 10.00
  342. 10:33:15.898446 T80190000 Read-Data Boiler water temperature: 0.00
  343. 10:33:15.963473 BC0194000 Read-Ack Boiler water temperature: 64.00
  344. 10:33:16.920829 T10010A00 Write-Data Control setpoint: 10.00
  345. 10:33:17.901948 T10010A00 Write-Data Control setpoint: 10.00
  346. 10:33:18.895344 T10010A00 Write-Data Control setpoint: 10.00
  347. 10:33:19.899297 T10010A00 Write-Data Control setpoint: 10.00
  348. 10:33:19.959569 BD0010A00 Write-Ack Control setpoint: 10.00
  349. 10:33:20.880056 T80000200 Read-Data Status: 00000010 00000000
  350. 10:33:21.909605 T80000200 Read-Data Status: 00000010 00000000
  351. 10:33:22.880265 T80000200 Read-Data Status: 00000010 00000000
  352. 10:33:22.985640 B40000200 Read-Ack Status: 00000010 00000000
  353. 10:33:23.876635 T80190000 Read-Data Boiler water temperature: 0.00
  354. 10:33:24.899770 T80190000 Read-Data Boiler water temperature: 0.00
  355. 10:33:25.880300 T80190000 Read-Data Boiler water temperature: 0.00
  356. 10:33:26.895247 T80190000 Read-Data Boiler water temperature: 0.00
  357. 10:33:26.954736 BC0194000 Read-Ack Boiler water temperature: 64.00
  358. 10:33:27.933613 T10010A00 Write-Data Control setpoint: 10.00
  359. 10:33:27.995562 BD0010A00 Write-Ack Control setpoint: 10.00
  360. 10:33:28.865970 T90395AFC Write-Data Max CH water setpoint: 90.98
  361. 10:33:29.897292 T90395AFC Write-Data Max CH water setpoint: 90.98
  362. 10:33:29.948038 B50395AFC Write-Ack Max CH water setpoint: 90.98
  363. 10:33:30.885149 T80000200 Read-Data Status: 00000010 00000000
  364. 10:33:30.946693 BC00002E0 Read-Ack Status: 00000010 11100000
  365. 10:33:31.868443 T80190000 Read-Data Boiler water temperature: 0.00
  366. 10:33:31.968195 B40193F00 Read-Ack Boiler water temperature: 63.00
  367. 10:33:32.897916 T10010A00 Write-Data Control setpoint: 10.00
  368. 10:33:32.997931 BD0010A00 Write-Ack Control setpoint: 10.00
  369. 10:33:33.889117 T00090000 Read-Data Remote override room setpoint: 0.00
  370. 10:33:33.892395 R00300000 Read-Data DHW setpoint boundaries: 0 0
  371. 10:33:33.939375 B40303F26 Read-Ack DHW setpoint boundaries: 63 38
  372. 10:33:33.994889 AC0090000 Read-Ack Remote override room setpoint: 0.00
  373. 10:33:34.872666 T80640000 Read-Data Remote override function: 00000000
  374. 10:33:34.875908 R00050000 Read-Data Application-specific flags: 00000000 0
  375. 10:33:34.928518 BC0050000 Read-Ack Application-specific flags: 00000000 0
  376. 10:33:34.986083 A40640000 Read-Ack Remote override function: 00000000
  377. 10:33:35.904541 T80190000 Read-Data Boiler water temperature: 0.00
  378. 10:33:35.958358 B40193F00 Read-Ack Boiler water temperature: 63.00
  379. 10:33:36.875126 T10010A00 Write-Data Control setpoint: 10.00
  380. 10:33:36.987890 BD0010A00 Write-Ack Control setpoint: 10.00
  381. 10:33:37.861837 T00110000 Read-Data Relative modulation level: 0.00
  382. 10:33:37.963338 BC0110000 Read-Ack Relative modulation level: 0.00
  383. 10:33:38.903047 T9018151C Write-Data Room temperature: 21.11
  384. 10:33:39.889376 T9018151C Write-Data Room temperature: 21.11
  385. 10:33:39.945860 BF0180000 Unk-DataId Room temperature: 0.00
  386. 10:33:40.911156 T80000200 Read-Data Status: 00000010 00000000
  387. 10:33:40.972200 B40000200 Read-Ack Status: 00000010 00000000
  388. 10:33:41.890484 T80190000 Read-Data Boiler water temperature: 0.00
  389. 10:33:42.006802 Error 03
  390. 10:33:42.872748 T80190000 Read-Data Boiler water temperature: 0.00
  391. 10:33:43.899087 T80190000 Read-Data Boiler water temperature: 0.00
  392. 10:33:43.952153 B40193F00 Read-Ack Boiler water temperature: 63.00
  393. 10:33:44.877688 T10010A00 Write-Data Control setpoint: 10.00
  394. 10:33:44.982754 BD0010A00 Write-Ack Control setpoint: 10.00
  395. 10:33:45.912124 T80190000 Read-Data Boiler water temperature: 0.00
  396. 10:33:46.886990 T80190000 Read-Data Boiler water temperature: 0.00
  397. 10:33:46.994076 B40193F00 Read-Ack Boiler water temperature: 63.00
  398. 10:33:47.875615 T10010A00 Write-Data Control setpoint: 10.00
  399. 10:33:47.933251 BD0010A00 Write-Ack Control setpoint: 10.00
  400. 10:33:48.898074 T00110000 Read-Data Relative modulation level: 0.00
  401. 10:33:49.004228 Error 03
  402. 10:33:49.880373 T00110000 Read-Data Relative modulation level: 0.00
  403. 10:33:50.868799 T80000200 Read-Data Status: 00000010 00000000
  404. 10:33:50.968325 B40000200 Read-Ack Status: 00000010 00000000
  405. 10:33:51.898707 T80190000 Read-Data Boiler water temperature: 0.00
  406. 10:33:51.961873 B40193F00 Read-Ack Boiler water temperature: 63.00
  407. 10:33:52.886816 T10010A00 Write-Data Control setpoint: 10.00
  408. 10:33:52.956593 BD0010A00 Write-Ack Control setpoint: 10.00
  409. 10:33:53.917177 T00110000 Read-Data Relative modulation level: 0.00
  410. 10:33:53.982707 BC0110000 Read-Ack Relative modulation level: 0.00
  411. 10:33:54.887614 T90101480 Write-Data Room setpoint: 20.50
  412. 10:33:54.991421 B70100000 Unk-DataId Room setpoint: 0.00
  413. 10:33:55.001688 AD0100000 Write-Ack Room setpoint: 0.00
  414. 10:33:55.873682 T80190000 Read-Data Boiler water temperature: 0.00
  415. 10:33:55.984610 B40193F00 Read-Ack Boiler water temperature: 63.00
  416. 10:33:56.904220 T10010A00 Write-Data Control setpoint: 10.00
  417. 10:33:57.007241 BD0010A00 Write-Ack Control setpoint: 10.00
  418. 10:33:57.900741 T10148A21 Write-Data Day of week and time of day: Thu 10:33
  419. 10:33:57.963057 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  420. 10:33:57.966681 AD0148A21 Write-Ack Day of week and time of day: Thu 10:33
  421. 10:33:58.890198 T801C0000 Read-Data Return water temperature: 0.00
  422. 10:33:59.005647 B401C2D00 Read-Ack Return water temperature: 45.00
  423. 10:33:59.877868 T801A0000 Read-Data DHW temperature: 0.00
  424. 10:33:59.996883 Error 03
  425. 10:34:00.908167 T80000200 Read-Data Status: 00000010 00000000
  426. 10:34:00.972916 B40000200 Read-Ack Status: 00000010 00000000
  427. 10:34:01.891718 T80190000 Read-Data Boiler water temperature: 0.00
  428. 10:34:01.953024 B40193F00 Read-Ack Boiler water temperature: 63.00
  429. 10:34:02.878079 T10010A00 Write-Data Control setpoint: 10.00
  430. 10:34:02.934589 BD0010A00 Write-Ack Control setpoint: 10.00
  431. 10:34:03.911220 T10383FFF Write-Data DHW setpoint: 64.00
  432. 10:34:03.967324 BD0383FFF Write-Ack DHW setpoint: 64.00
  433. 10:34:04.888159 T90395AFC Write-Data Max CH water setpoint: 90.98
  434. 10:34:04.996249 B50395AFC Write-Ack Max CH water setpoint: 90.98
  435. 10:34:05.888224 T80190000 Read-Data Boiler water temperature: 0.00
  436. 10:34:05.938657 B40193F00 Read-Ack Boiler water temperature: 63.00
  437. 10:34:06.909683 T10010A00 Write-Data Control setpoint: 10.00
  438. 10:34:06.966775 BD0010A00 Write-Ack Control setpoint: 10.00
  439. 10:34:07.899801 T00090000 Read-Data Remote override room setpoint: 0.00
  440. 10:34:07.956997 BF0090000 Unk-DataId Remote override room setpoint: 0.00
  441. 10:34:08.012823 AC0090000 Read-Ack Remote override room setpoint: 0.00
  442. 10:34:08.889998 T80640000 Read-Data Remote override function: 00000000
  443. 10:34:08.939779 B70640000 Unk-DataId Remote override function: 00000000
  444. 10:34:08.984673 A40640000 Read-Ack Remote override function: 00000000
  445. 10:34:09.904750 T00110000 Read-Data Relative modulation level: 0.00
  446. 10:34:10.057928 Error 04
  447. 10:34:10.061193 EC01101FF
  448. 10:34:10.889286 T80000200 Read-Data Status: 00000010 00000000
  449. 10:34:11.875634 T80000200 Read-Data Status: 00000010 00000000
  450. 10:34:11.985714 B40000200 Read-Ack Status: 00000010 00000000
  451. 10:34:12.904240 T80190000 Read-Data Boiler water temperature: 0.00
  452. 10:34:12.961767 B40193F00 Read-Ack Boiler water temperature: 63.00
  453. 10:34:13.897746 T10010A00 Write-Data Control setpoint: 10.00
  454. 10:34:14.011108 Error 03
  455. 10:34:14.878237 T10010A00 Write-Data Control setpoint: 10.00
  456. 10:34:15.897121 T80190000 Read-Data Boiler water temperature: 0.00
  457. 10:34:15.950932 B40193F00 Read-Ack Boiler water temperature: 63.00
  458. 10:34:16.901786 T10010A00 Write-Data Control setpoint: 10.00
  459. 10:34:16.952838 BD0010A00 Write-Ack Control setpoint: 10.00
  460. 10:34:17.923797 T00110000 Read-Data Relative modulation level: 0.00
  461. 10:34:18.892593 T00110000 Read-Data Relative modulation level: 0.00
  462. 10:34:18.945007 BC0110000 Read-Ack Relative modulation level: 0.00
  463. 10:34:19.871256 T10181522 Write-Data Room temperature: 21.13
  464. 10:34:19.978207 BF0180000 Unk-DataId Room temperature: 0.00
  465. 10:34:20.910498 T80000200 Read-Data Status: 00000010 00000000
  466. 10:34:21.002686 B40000200 Read-Ack Status: 00000010 00000000
  467. 10:34:21.896038 T80190000 Read-Data Boiler water temperature: 0.00
  468. 10:34:21.952247 B40193F00 Read-Ack Boiler water temperature: 63.00
  469. 10:34:22.872506 T10010A00 Write-Data Control setpoint: 10.00
  470. 10:34:22.973220 BD0010A00 Write-Ack Control setpoint: 10.00
  471. 10:34:23.927935 T00110000 Read-Data Relative modulation level: 0.00
  472. 10:34:23.977807 BC0110000 Read-Ack Relative modulation level: 0.00
  473. 10:34:24.892987 T90101480 Write-Data Room setpoint: 20.50
  474. 10:34:25.865173 T80190000 Read-Data Boiler water temperature: 0.00
  475. 10:34:25.964634 B40193F00 Read-Ack Boiler water temperature: 63.00
  476. 10:34:26.902574 T10010A00 Write-Data Control setpoint: 10.00
  477. 10:34:26.967681 BD0010A00 Write-Ack Control setpoint: 10.00
  478. 10:34:27.898344 T90101480 Write-Data Room setpoint: 20.50
  479. 10:34:27.971278 Error 03
  480. 10:34:28.907153 T90101480 Write-Data Room setpoint: 20.50
  481. 10:34:29.012480 B70100000 Unk-DataId Room setpoint: 0.00
  482. 10:34:29.028504 AD0100000 Write-Ack Room setpoint: 0.00
  483. 10:34:29.899917 T10148A21 Write-Data Day of week and time of day: Thu 10:33
  484. 10:34:29.958834 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  485. 10:34:30.004745 AD0148A21 Write-Ack Day of week and time of day: Thu 10:33
  486. 10:34:30.896111 T80000200 Read-Data Status: 00000010 00000000
  487. 10:34:31.012386 B40000200 Read-Ack Status: 00000010 00000000
  488. 10:34:31.886210 T80190000 Read-Data Boiler water temperature: 0.00
  489. 10:34:31.952810 B40193F00 Read-Ack Boiler water temperature: 63.00
  490. 10:34:32.870637 T10010A00 Write-Data Control setpoint: 10.00
  491. 10:34:32.932680 BD0010A00 Write-Ack Control setpoint: 10.00
  492. 10:34:33.910086 T00110000 Read-Data Relative modulation level: 0.00
  493. 10:34:33.967420 BC0110000 Read-Ack Relative modulation level: 0.00
  494. 10:34:34.885095 T801C0000 Read-Data Return water temperature: 0.00
  495. 10:34:34.995702 Error 03
  496. 10:34:35.863840 T80190000 Read-Data Boiler water temperature: 0.00
  497. 10:34:36.899051 T80190000 Read-Data Boiler water temperature: 0.00
  498. 10:34:36.953394 B40193F00 Read-Ack Boiler water temperature: 63.00
  499. 10:34:37.884954 T10010A00 Write-Data Control setpoint: 10.00
  500. 10:34:37.938076 BD0010A00 Write-Ack Control setpoint: 10.00
  501. 10:34:38.920933 T801C0000 Read-Data Return water temperature: 0.00
  502. 10:34:39.885132 T801C0000 Read-Data Return water temperature: 0.00
  503. 10:34:39.987249 B401C2D00 Read-Ack Return water temperature: 45.00
  504. 10:34:40.874715 T80000200 Read-Data Status: 00000010 00000000
  505. 10:34:40.968008 B40000200 Read-Ack Status: 00000010 00000000
  506. 10:34:41.904175 T80190000 Read-Data Boiler water temperature: 0.00
  507. 10:34:42.020482 Error 04
  508. 10:34:42.023563 E40393F00
  509. 10:34:42.890533 T80190000 Read-Data Boiler water temperature: 0.00
  510. 10:34:43.916277 T80190000 Read-Data Boiler water temperature: 0.00
  511. 10:34:43.967906 B40193F00 Read-Ack Boiler water temperature: 63.00
  512. 10:34:44.890247 T10010A00 Write-Data Control setpoint: 10.00
  513. 10:34:44.990312 BD0010A00 Write-Ack Control setpoint: 10.00
  514. 10:34:45.877293 T80190000 Read-Data Boiler water temperature: 0.00
  515. 10:34:45.979960 B40193F00 Read-Ack Boiler water temperature: 63.00
  516. 10:34:46.901680 T10010A00 Write-Data Control setpoint: 10.00
  517. 10:34:46.995827 BD0010A00 Write-Ack Control setpoint: 10.00
  518. 10:34:47.889217 T00110000 Read-Data Relative modulation level: 0.00
  519. 10:34:47.950238 BC0110000 Read-Ack Relative modulation level: 0.00
  520. 10:34:48.866644 T801A0000 Read-Data DHW temperature: 0.00
  521. 10:34:48.977096 BC01A3200 Read-Ack DHW temperature: 50.00
  522. 10:34:49.917123 T001B0000 Read-Data Outside temperature: 0.00
  523. 10:34:49.983308 B401BE0FF Read-Ack Outside temperature: -31.00
  524. 10:34:50.899202 T80000200 Read-Data Status: 00000010 00000000
  525. 10:34:50.997140 BC00002E0 Read-Ack Status: 00000010 11100000
  526. 10:34:51.894811 T80190000 Read-Data Boiler water temperature: 0.00
  527. 10:34:51.991090 B40193F00 Read-Ack Boiler water temperature: 63.00
  528. 10:34:52.870991 T10010A00 Write-Data Control setpoint: 10.00
  529. 10:34:52.993293 Error 03
  530. 10:34:53.900917 T10010A00 Write-Data Control setpoint: 10.00
  531. 10:34:53.991862 BD0010A00 Write-Ack Control setpoint: 10.00
  532. 10:34:54.876771 T00110000 Read-Data Relative modulation level: 0.00
  533. 10:34:54.943752 BC0110000 Read-Ack Relative modulation level: 0.00
  534. 10:34:55.863059 T80190000 Read-Data Boiler water temperature: 0.00
  535. 10:34:55.964293 B40193F00 Read-Ack Boiler water temperature: 63.00
  536. 10:34:56.905691 T10010A00 Write-Data Control setpoint: 10.00
  537. 10:34:57.870430 T10010A00 Write-Data Control setpoint: 10.00
  538. 10:34:57.985133 BD0010A00 Write-Ack Control setpoint: 10.00
  539. 10:34:58.906184 T00120000 Read-Data CH water pressure: 0.00
  540. 10:34:58.969180 B40120166 Read-Ack CH water pressure: 1.40
  541. 10:34:59.904540 T80000200 Read-Data Status: 00000010 00000000
  542. 10:35:00.016674 B40000260 Read-Ack Status: 00000010 01100000
  543. 10:35:00.877689 T80000200 Read-Data Status: 00000010 00000000
  544. 10:35:00.947438 B40000260 Read-Ack Status: 00000010 01100000
  545. 10:35:01.897013 T80000200 Read-Data Status: 00000010 00000000
  546. 10:35:01.983338 B40000260 Read-Ack Status: 00000010 01100000
  547. 10:35:02.935712 T80190000 Read-Data Boiler water temperature: 0.00
  548. 10:35:02.995932 Error 03
  549. 10:35:03.885278 T80190000 Read-Data Boiler water temperature: 0.00
  550. 10:35:04.921032 T80190000 Read-Data Boiler water temperature: 0.00
  551. 10:35:04.981577 B40193F00 Read-Ack Boiler water temperature: 63.00
  552. 10:35:05.913179 T10010A00 Write-Data Control setpoint: 10.00
  553. 10:35:06.015808 BD0010A00 Write-Ack Control setpoint: 10.00
  554. 10:35:06.896618 T80190000 Read-Data Boiler water temperature: 0.00
  555. 10:35:06.949509 Error 03
  556. 10:35:07.894462 T80190000 Read-Data Boiler water temperature: 0.00
  557. 10:35:07.994715 B40193F00 Read-Ack Boiler water temperature: 63.00
  558. 10:35:08.874550 T10010A00 Write-Data Control setpoint: 10.00
  559. 10:35:08.983295 BD0010A00 Write-Ack Control setpoint: 10.00
  560. 10:35:09.920889 T10383FFF Write-Data DHW setpoint: 64.00
  561. 10:35:10.040334 Error 04
  562. 10:35:10.048315 ED0383FBF
  563. 10:35:10.893748 T10383FFF Write-Data DHW setpoint: 64.00
  564. 10:35:11.883588 T80000200 Read-Data Status: 00000010 00000000
  565. 10:35:11.937927 BC00002E0 Read-Ack Status: 00000010 11100000
  566. 10:35:12.920058 T80190000 Read-Data Boiler water temperature: 0.00
  567. 10:35:12.969914 B40193F00 Read-Ack Boiler water temperature: 63.00
  568. 10:35:13.886401 T10010A00 Write-Data Control setpoint: 10.00
  569. 10:35:14.002187 Error 04
  570. 10:35:14.008711 E90010A00
  571. 10:35:14.874257 T10010A00 Write-Data Control setpoint: 10.00
  572. 10:35:15.958673 T10010A00 Write-Data Control setpoint: 10.00
  573. 10:35:15.969606 BD0010A00 Write-Ack Control setpoint: 10.00
  574. 10:35:16.879476 T80190000 Read-Data Boiler water temperature: 0.00
  575. 10:35:16.992183 B40193F00 Read-Ack Boiler water temperature: 63.00
  576. 10:35:17.855905 T10010A00 Write-Data Control setpoint: 10.00
  577. 10:35:17.958496 BD0010A00 Write-Ack Control setpoint: 10.00
  578. 10:35:18.905609 T10383FFF Write-Data DHW setpoint: 64.00
  579. 10:35:18.967502 BD0383FFF Write-Ack DHW setpoint: 64.00
  580. 10:35:19.889189 T90395AFC Write-Data Max CH water setpoint: 90.98
  581. 10:35:19.948031 B50395AFC Write-Ack Max CH water setpoint: 90.98
  582. 10:35:20.872478 T00090000 Read-Data Remote override room setpoint: 0.00
  583. 10:35:20.875546 R00050000 Read-Data Application-specific flags: 00000000 0
  584. 10:35:20.980867 Error 03
  585. 10:35:21.887583 T80000200 Read-Data Status: 00000010 00000000
  586. 10:35:22.000475 B40000200 Read-Ack Status: 00000010 00000000
  587. 10:35:22.876156 T80190000 Read-Data Boiler water temperature: 0.00
  588. 10:35:22.942330 B40193F00 Read-Ack Boiler water temperature: 63.00
  589. 10:35:23.898815 T10010A00 Write-Data Control setpoint: 10.00
  590. 10:35:24.004915 BD0010A00 Write-Ack Control setpoint: 10.00
  591. 10:35:24.894964 T00090000 Read-Data Remote override room setpoint: 0.00
  592. 10:35:24.901603 R00050000 Read-Data Application-specific flags: 00000000 0
  593. 10:35:25.873873 T00090000 Read-Data Remote override room setpoint: 0.00
  594. 10:35:25.878466 R00050000 Read-Data Application-specific flags: 00000000 0
  595. 10:35:25.973864 BC0050000 Read-Ack Application-specific flags: 00000000 0
  596. 10:35:25.977825 AC0090000 Read-Ack Remote override room setpoint: 0.00
  597. 10:35:26.916969 T80190000 Read-Data Boiler water temperature: 0.00
  598. 10:35:26.964619 B40193F00 Read-Ack Boiler water temperature: 63.00
  599. 10:35:27.883691 T10010A00 Write-Data Control setpoint: 10.00
  600. 10:35:27.993814 Error 03
  601. 10:35:28.867390 T10010A00 Write-Data Control setpoint: 10.00
  602. 10:35:29.882936 T10010A00 Write-Data Control setpoint: 10.00
  603. 10:35:29.986177 BD0010A00 Write-Ack Control setpoint: 10.00
  604. 10:35:30.886194 T80640000 Read-Data Remote override function: 00000000
  605. 10:35:30.983896 B70640000 Unk-DataId Remote override function: 00000000
  606. 10:35:30.988616 A40640000 Read-Ack Remote override function: 00000000
  607. 10:35:31.872817 T80000200 Read-Data Status: 00000010 00000000
  608. 10:35:31.972884 B40000200 Read-Ack Status: 00000010 00000000
  609. 10:35:32.889560 T80190000 Read-Data Boiler water temperature: 0.00
  610. 10:35:33.004006 B40193F00 Read-Ack Boiler water temperature: 63.00
  611. 10:35:33.877609 T10010A00 Write-Data Control setpoint: 10.00
  612. 10:35:33.978485 BD0010A00 Write-Ack Control setpoint: 10.00
  613. 10:35:34.878517 T00110000 Read-Data Relative modulation level: 0.00
  614. 10:35:34.928182 BC0110000 Read-Ack Relative modulation level: 0.00
  615. 10:35:35.910395 T90181520 Write-Data Room temperature: 21.13
  616. 10:35:35.970888 BF0180000 Unk-DataId Room temperature: 0.00
  617. 10:35:36.888765 T80190000 Read-Data Boiler water temperature: 0.00
  618. 10:35:36.996747 B40193F00 Read-Ack Boiler water temperature: 63.00
  619. 10:35:37.876103 T10010A00 Write-Data Control setpoint: 10.00
  620. 10:35:37.973208 BD0010A00 Write-Ack Control setpoint: 10.00
  621. 10:35:38.893496 T90101480 Write-Data Room setpoint: 20.50
  622. 10:35:39.024901 B70100000 Unk-DataId Room setpoint: 0.00
  623. 10:35:39.028868 AD0100000 Write-Ack Room setpoint: 0.00
  624. 10:35:39.883114 T10148A22 Write-Data Day of week and time of day: Thu 10:34
  625. 10:35:39.948057 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  626. 10:35:39.996452 AD0148A22 Write-Ack Day of week and time of day: Thu 10:34
  627. 10:35:40.883364 T801C0000 Read-Data Return water temperature: 0.00
  628. 10:35:40.978346 B401C2D00 Read-Ack Return water temperature: 45.00
  629. 10:35:41.862340 T80000200 Read-Data Status: 00000010 00000000
  630. 10:35:41.967285 B40000200 Read-Ack Status: 00000010 00000000
  631. 10:35:42.902631 T80190000 Read-Data Boiler water temperature: 0.00
  632. 10:35:43.001246 B40193F00 Read-Ack Boiler water temperature: 63.00
  633. 10:35:43.886875 T10010A00 Write-Data Control setpoint: 10.00
  634. 10:35:43.989521 BD0010A00 Write-Ack Control setpoint: 10.00
  635. 10:35:44.874748 T00110000 Read-Data Relative modulation level: 0.00
  636. 10:35:44.978114 BC0110000 Read-Ack Relative modulation level: 0.00
  637. 10:35:45.900035 T801A0000 Read-Data DHW temperature: 0.00
  638. 10:35:45.984101 BC01A3200 Read-Ack DHW temperature: 50.00
  639. 10:35:46.887213 T80190000 Read-Data Boiler water temperature: 0.00
  640. 10:35:46.997235 B40193F00 Read-Ack Boiler water temperature: 63.00
  641. 10:35:47.869324 T10010A00 Write-Data Control setpoint: 10.00
  642. 10:35:47.970165 BD0010A00 Write-Ack Control setpoint: 10.00
  643. 10:35:48.903547 T001B0000 Read-Data Outside temperature: 0.00
  644. 10:35:49.006522 Error 04
  645. 10:35:49.009773 E401BE8FF
  646. 10:35:49.891591 T001B0000 Read-Data Outside temperature: 0.00
  647. 10:35:50.875880 T001B0000 Read-Data Outside temperature: 0.00
  648. 10:35:50.968446 B401BE0FF Read-Ack Outside temperature: -31.00
  649. 10:35:51.904397 T80000200 Read-Data Status: 00000010 00000000
  650. 10:35:51.962458 BC00002E0 Read-Ack Status: 00000010 11100000
  651. 10:35:52.890704 T80190000 Read-Data Boiler water temperature: 0.00
  652. 10:35:52.946116 B40193F00 Read-Ack Boiler water temperature: 63.00
  653. 10:35:53.876693 T10010A00 Write-Data Control setpoint: 10.00
  654. 10:35:53.931160 BD0010A00 Write-Ack Control setpoint: 10.00
  655. 10:35:54.894377 T00110000 Read-Data Relative modulation level: 0.00
  656. 10:35:54.996688 BC0110000 Read-Ack Relative modulation level: 0.00
  657. 10:35:55.913123 T00120000 Read-Data CH water pressure: 0.00
  658. 10:35:55.963674 B40120166 Read-Ack CH water pressure: 1.40
  659. 10:35:56.876566 T80190000 Read-Data Boiler water temperature: 0.00
  660. 10:35:57.899510 T80190000 Read-Data Boiler water temperature: 0.00
  661. 10:35:57.996070 B40193F00 Read-Ack Boiler water temperature: 63.00
  662. 10:35:58.881405 T10010A00 Write-Data Control setpoint: 10.00
  663. 10:35:58.980256 BD0010A00 Write-Ack Control setpoint: 10.00
  664. 10:35:59.860825 T80000200 Read-Data Status: 00000010 00000000
  665. 10:35:59.981504 Error 03
  666. 10:36:00.886467 T80000200 Read-Data Status: 00000010 00000000
  667. 10:36:00.988297 B40000200 Read-Ack Status: 00000010 00000000
  668. 10:36:01.882272 T80000200 Read-Data Status: 00000010 00000000
  669. 10:36:01.993039 B40000200 Read-Ack Status: 00000010 00000000
  670. 10:36:02.914618 T80190000 Read-Data Boiler water temperature: 0.00
  671. 10:36:02.971601 B40193F00 Read-Ack Boiler water temperature: 63.00
  672. 10:36:03.885254 T10010A00 Write-Data Control setpoint: 10.00
  673. 10:36:04.875668 T10010A00 Write-Data Control setpoint: 10.00
  674. 10:36:04.980545 BD0010A00 Write-Ack Control setpoint: 10.00
  675. 10:36:05.903855 T10383FFF Write-Data DHW setpoint: 64.00
  676. 10:36:06.007127 Error 04
  677. 10:36:06.014598 ED1383FFF
  678. 10:36:06.885387 T80190000 Read-Data Boiler water temperature: 0.00
  679. 10:36:06.988123 Error 03
  680. 10:36:07.897848 T80190000 Read-Data Boiler water temperature: 0.00
  681. 10:36:08.036319 Error 03
  682. 10:36:08.897098 T80190000 Read-Data Boiler water temperature: 0.00
  683. 10:36:08.953963 B40193F00 Read-Ack Boiler water temperature: 63.00
  684. 10:36:09.871464 T10010A00 Write-Data Control setpoint: 10.00
  685. 10:36:09.941582 Error 03
  686. 10:36:10.897805 T10010A00 Write-Data Control setpoint: 10.00
  687. 10:36:11.880059 T80000200 Read-Data Status: 00000010 00000000
  688. 10:36:12.016378 B40000200 Read-Ack Status: 00000010 00000000
  689. 10:36:12.953605 T80190000 Read-Data Boiler water temperature: 0.00
  690. 10:36:13.017237 B40193F00 Read-Ack Boiler water temperature: 63.00
  691. 10:36:13.917459 T10010A00 Write-Data Control setpoint: 10.00
  692. 10:36:14.007738 Error 03
  693. 10:36:14.870068 T10010A00 Write-Data Control setpoint: 10.00
  694. 10:36:15.906831 T10010A00 Write-Data Control setpoint: 10.00
  695. 10:36:16.877192 T80190000 Read-Data Boiler water temperature: 0.00
  696. 10:36:16.934709 B40193F00 Read-Ack Boiler water temperature: 63.00
  697. 10:36:17.893552 T10010A00 Write-Data Control setpoint: 10.00
  698. 10:36:18.872187 T10010A00 Write-Data Control setpoint: 10.00
  699. 10:36:19.901315 T10010A00 Write-Data Control setpoint: 10.00
  700. 10:36:20.879439 T10010A00 Write-Data Control setpoint: 10.00
  701. 10:36:21.894514 T80000200 Read-Data Status: 00000010 00000000
  702. 10:36:22.887261 T80000200 Read-Data Status: 00000010 00000000
  703. 10:36:23.910251 T80000200 Read-Data Status: 00000010 00000000
  704. 10:36:24.896502 T80000200 Read-Data Status: 00000010 00000000
  705. 10:36:24.948070 B40000200 Read-Ack Status: 00000010 00000000
  706. 10:36:25.871486 T80190000 Read-Data Boiler water temperature: 0.00
  707. 10:36:26.898951 T80190000 Read-Data Boiler water temperature: 0.00
  708. 10:36:26.997633 B40193F00 Read-Ack Boiler water temperature: 63.00
  709. 10:36:27.868442 T10010A00 Write-Data Control setpoint: 10.00
  710. 10:36:27.979702 Error 03
  711. 10:36:28.897810 T10010A00 Write-Data Control setpoint: 10.00
  712. 10:36:29.003342 BD0010A00 Write-Ack Control setpoint: 10.00
  713. 10:36:29.889410 T10383FFF Write-Data DHW setpoint: 64.00
  714. 10:36:29.946634 BD0383FFF Write-Ack DHW setpoint: 64.00
  715. 10:36:30.883420 T90395AFC Write-Data Max CH water setpoint: 90.98
  716. 10:36:31.001488 B50395AFC Write-Ack Max CH water setpoint: 90.98
  717. 10:36:31.918363 T80000200 Read-Data Status: 00000010 00000000
  718. 10:36:32.883662 T80000200 Read-Data Status: 00000010 00000000
  719. 10:36:32.986599 BC00002E0 Read-Ack Status: 00000010 11100000
  720. 10:36:33.868954 T80190000 Read-Data Boiler water temperature: 0.00
  721. 10:36:33.969087 B40193F00 Read-Ack Boiler water temperature: 63.00
  722. 10:36:34.899730 T10010A00 Write-Data Control setpoint: 10.00
  723. 10:36:35.010095 Error 03
  724. 10:36:35.882525 T10010A00 Write-Data Control setpoint: 10.00
  725. 10:36:36.901941 T80190000 Read-Data Boiler water temperature: 0.00
  726. 10:36:36.962380 B40193F00 Read-Ack Boiler water temperature: 63.00
  727. 10:36:37.889194 T10010A00 Write-Data Control setpoint: 10.00
  728. 10:36:37.990420 BD0010A00 Write-Ack Control setpoint: 10.00
  729. 10:36:38.875273 T00090000 Read-Data Remote override room setpoint: 0.00
  730. 10:36:38.878524 R00050000 Read-Data Application-specific flags: 00000000 0
  731. 10:36:38.988183 BC0050000 Read-Ack Application-specific flags: 00000000 0
  732. 10:36:38.993750 AC0090000 Read-Ack Remote override room setpoint: 0.00
  733. 10:36:39.905205 T80640000 Read-Data Remote override function: 00000000
  734. 10:36:39.959175 B70640000 Unk-DataId Remote override function: 00000000
  735. 10:36:40.005003 A40640000 Read-Ack Remote override function: 00000000
  736. 10:36:40.889491 T00110000 Read-Data Relative modulation level: 0.00
  737. 10:36:40.958575 BC0110000 Read-Ack Relative modulation level: 0.00
  738. 10:36:41.875788 T80000200 Read-Data Status: 00000010 00000000
  739. 10:36:41.927504 B40000200 Read-Ack Status: 00000010 00000000
  740. 10:36:42.901013 T80190000 Read-Data Boiler water temperature: 0.00
  741. 10:36:43.875825 T80190000 Read-Data Boiler water temperature: 0.00
  742. 10:36:43.966334 B40193F00 Read-Ack Boiler water temperature: 63.00
  743. 10:36:44.916191 T10010A00 Write-Data Control setpoint: 10.00
  744. 10:36:44.966862 BD0010A00 Write-Ack Control setpoint: 10.00
  745. 10:36:45.901537 T00110000 Read-Data Relative modulation level: 0.00
  746. 10:36:45.952494 BC0110000 Read-Ack Relative modulation level: 0.00
  747. 10:36:46.870684 T80190000 Read-Data Boiler water temperature: 0.00
  748. 10:36:46.969910 B40193F00 Read-Ack Boiler water temperature: 63.00
  749. 10:36:47.904377 T10010A00 Write-Data Control setpoint: 10.00
  750. 10:36:47.961522 BD0010A00 Write-Ack Control setpoint: 10.00
  751. 10:36:48.889755 T90181523 Write-Data Room temperature: 21.14
  752. 10:36:48.951247 BF0180000 Unk-DataId Room temperature: 0.00
  753. 10:36:49.883357 T90101480 Write-Data Room setpoint: 20.50
  754. 10:36:49.937065 B70100000 Unk-DataId Room setpoint: 0.00
  755. 10:36:49.992328 AD0100000 Write-Ack Room setpoint: 0.00
  756. 10:36:50.901223 T90148A23 Write-Data Day of week and time of day: Thu 10:35
  757. 10:36:51.009551 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  758. 10:36:51.025191 A50148A23 Write-Ack Day of week and time of day: Thu 10:35
  759. 10:36:51.939118 T80000200 Read-Data Status: 00000010 00000000
  760. 10:36:51.985607 B40000200 Read-Ack Status: 00000010 00000000
  761. 10:36:52.888208 T80190000 Read-Data Boiler water temperature: 0.00
  762. 10:36:52.987659 B40193F00 Read-Ack Boiler water temperature: 63.00
  763. 10:36:53.878252 T10010A00 Write-Data Control setpoint: 10.00
  764. 10:36:53.977801 BD0010A00 Write-Ack Control setpoint: 10.00
  765. 10:36:54.925251 T00110000 Read-Data Relative modulation level: 0.00
  766. 10:36:54.980651 BC0110000 Read-Ack Relative modulation level: 0.00
  767. 10:36:55.898253 T801C0000 Read-Data Return water temperature: 0.00
  768. 10:36:55.965636 BC01C2C00 Read-Ack Return water temperature: 44.00
  769. 10:36:56.871779 T80190000 Read-Data Boiler water temperature: 0.00
  770. 10:36:56.985909 BC0193E00 Read-Ack Boiler water temperature: 62.00
  771. 10:36:57.907089 T10010A00 Write-Data Control setpoint: 10.00
  772. 10:36:58.004987 BD0010A00 Write-Ack Control setpoint: 10.00
  773. 10:36:58.895249 T801A0000 Read-Data DHW temperature: 0.00
  774. 10:36:58.994845 BC01A3200 Read-Ack DHW temperature: 50.00
  775. 10:36:59.878787 T001B0000 Read-Data Outside temperature: 0.00
  776. 10:36:59.994370 Error 03
  777. 10:37:00.915850 T001B0000 Read-Data Outside temperature: 0.00
  778. 10:37:00.961315 B401BE0FF Read-Ack Outside temperature: -31.00
  779. 10:37:01.887538 T80000200 Read-Data Status: 00000010 00000000
  780. 10:37:01.983266 BC00002E0 Read-Ack Status: 00000010 11100000
  781. 10:37:02.883987 T80000200 Read-Data Status: 00000010 00000000
  782. 10:37:02.936840 BC00002E0 Read-Ack Status: 00000010 11100000
  783. 10:37:03.911427 T80190000 Read-Data Boiler water temperature: 0.00
  784. 10:37:04.894995 T80190000 Read-Data Boiler water temperature: 0.00
  785. 10:37:04.952768 BC0193E00 Read-Ack Boiler water temperature: 62.00
  786. 10:37:05.866698 T10010A00 Write-Data Control setpoint: 10.00
  787. 10:37:05.948220 BD0010A00 Write-Ack Control setpoint: 10.00
  788. 10:37:06.898175 T10383FFF Write-Data DHW setpoint: 64.00
  789. 10:37:07.000658 BD0383FFF Write-Ack DHW setpoint: 64.00
  790. 10:37:07.886729 T80190000 Read-Data Boiler water temperature: 0.00
  791. 10:37:07.983828 BC0193E00 Read-Ack Boiler water temperature: 62.00
  792. 10:37:08.872821 T10010A00 Write-Data Control setpoint: 10.00
  793. 10:37:08.968377 BD0010A00 Write-Ack Control setpoint: 10.00
  794. 10:37:09.910959 T90395AFC Write-Data Max CH water setpoint: 90.98
  795. 10:37:09.957201 B50395AFC Write-Ack Max CH water setpoint: 90.98
  796. 10:37:10.929632 T00090000 Read-Data Remote override room setpoint: 0.00
  797. 10:37:10.932900 R00050000 Read-Data Application-specific flags: 00000000 0
  798. 10:37:11.876584 T00090000 Read-Data Remote override room setpoint: 0.00
  799. 10:37:11.883532 R00050000 Read-Data Application-specific flags: 00000000 0
  800. 10:37:11.977529 BC005C000 Read-Ack Application-specific flags: 11000000 0
  801. 10:37:11.984992 AC0090000 Read-Ack Remote override room setpoint: 0.00
  802. 10:37:12.904236 T80000200 Read-Data Status: 00000010 00000000
  803. 10:37:12.960804 B40000200 Read-Ack Status: 00000010 00000000
  804. 10:37:13.895934 T80190000 Read-Data Boiler water temperature: 0.00
  805. 10:37:14.009578 Error 03
  806. 10:37:14.868087 T80190000 Read-Data Boiler water temperature: 0.00
  807. 10:37:15.892699 T80190000 Read-Data Boiler water temperature: 0.00
  808. 10:37:15.984982 BC0193E00 Read-Ack Boiler water temperature: 62.00
  809. 10:37:16.868409 T10010A00 Write-Data Control setpoint: 10.00
  810. 10:37:16.997761 BD0010A00 Write-Ack Control setpoint: 10.00
  811. 10:37:17.908183 T80190000 Read-Data Boiler water temperature: 0.00
  812. 10:37:18.881190 T80190000 Read-Data Boiler water temperature: 0.00
  813. 10:37:18.994361 BC0193E00 Read-Ack Boiler water temperature: 62.00
  814. 10:37:19.885255 T10010A00 Write-Data Control setpoint: 10.00
  815. 10:37:19.932997 BD0010A00 Write-Ack Control setpoint: 10.00
  816. 10:37:20.911314 T80640000 Read-Data Remote override function: 00000000
  817. 10:37:21.017740 Error 03
  818. 10:37:21.933053 T80640000 Read-Data Remote override function: 00000000
  819. 10:37:22.934827 T80000200 Read-Data Status: 00000010 00000000
  820. 10:37:23.020356 B40000200 Read-Ack Status: 00000010 00000000
  821. 10:37:23.914653 T80190000 Read-Data Boiler water temperature: 0.00
  822. 10:37:23.960409 BC0193E00 Read-Ack Boiler water temperature: 62.00
  823. 10:37:24.909501 T10010A00 Write-Data Control setpoint: 10.00
  824. 10:37:25.006213 BD0010A00 Write-Ack Control setpoint: 10.00
  825. 10:37:25.896384 T80640000 Read-Data Remote override function: 00000000
  826. 10:37:26.036993 B70640000 Unk-DataId Remote override function: 00000000
  827. 10:37:26.040630 A40640000 Read-Ack Remote override function: 00000000
  828. 10:37:26.882052 T00110000 Read-Data Relative modulation level: 0.00
  829. 10:37:26.983614 BC0110000 Read-Ack Relative modulation level: 0.00
  830. 10:37:27.874695 T80190000 Read-Data Boiler water temperature: 0.00
  831. 10:37:27.984576 BC0193E00 Read-Ack Boiler water temperature: 62.00
  832. 10:37:28.906187 T10010A00 Write-Data Control setpoint: 10.00
  833. 10:37:29.005014 BD0010A00 Write-Ack Control setpoint: 10.00
  834. 10:37:29.889697 T10181524 Write-Data Room temperature: 21.14
  835. 10:37:29.989627 BF0180000 Unk-DataId Room temperature: 0.00
  836. 10:37:30.882302 T90101480 Write-Data Room setpoint: 20.50
  837. 10:37:30.995018 B70100000 Unk-DataId Room setpoint: 0.00
  838. 10:37:30.998359 AD0100000 Write-Ack Room setpoint: 0.00
  839. 10:37:31.874937 T90148A23 Write-Data Day of week and time of day: Thu 10:35
  840. 10:37:31.982487 Error 03
  841. 10:37:32.896125 T80000200 Read-Data Status: 00000010 00000000
  842. 10:37:33.008944 B40000200 Read-Ack Status: 00000010 00000000
  843. 10:37:33.871872 T80190000 Read-Data Boiler water temperature: 0.00
  844. 10:37:33.970042 BC0193E00 Read-Ack Boiler water temperature: 62.00
  845. 10:37:34.908938 T10010A00 Write-Data Control setpoint: 10.00
  846. 10:37:35.019691 Error 03
  847. 10:37:35.883702 T10010A00 Write-Data Control setpoint: 10.00
  848. 10:37:36.877350 T10010A00 Write-Data Control setpoint: 10.00
  849. 10:37:36.978420 BD0010A00 Write-Ack Control setpoint: 10.00
  850. 10:37:37.896221 T80190000 Read-Data Boiler water temperature: 0.00
  851. 10:37:37.995498 BC0193E00 Read-Ack Boiler water temperature: 62.00
  852. 10:37:38.881868 T10010A00 Write-Data Control setpoint: 10.00
  853. 10:37:38.990773 BD0010A00 Write-Ack Control setpoint: 10.00
  854. 10:37:39.876048 T00110000 Read-Data Relative modulation level: 0.00
  855. 10:37:39.929552 BC0110000 Read-Ack Relative modulation level: 0.00
  856. 10:37:40.897303 T90148A23 Write-Data Day of week and time of day: Thu 10:35
  857. 10:37:41.010185 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  858. 10:37:41.013517 A50148A23 Write-Ack Day of week and time of day: Thu 10:35
  859. 10:37:41.905049 T801C0000 Read-Data Return water temperature: 0.00
  860. 10:37:42.014265 Error 03
  861. 10:37:42.884640 T80000200 Read-Data Status: 00000010 00000000
  862. 10:37:43.903395 T80000200 Read-Data Status: 00000010 00000000
  863. 10:37:44.005332 B40000200 Read-Ack Status: 00000010 00000000
  864. 10:37:44.889592 T80190000 Read-Data Boiler water temperature: 0.00
  865. 10:37:44.990945 BC0193E00 Read-Ack Boiler water temperature: 62.00
  866. 10:37:45.879230 T10010A00 Write-Data Control setpoint: 10.00
  867. 10:37:45.991231 Error 03
  868. 10:37:46.893504 T10010A00 Write-Data Control setpoint: 10.00
  869. 10:37:46.997970 BD0010A00 Write-Ack Control setpoint: 10.00
  870. 10:37:47.877051 T80190000 Read-Data Boiler water temperature: 0.00
  871. 10:37:47.971808 BC0193E00 Read-Ack Boiler water temperature: 62.00
  872. 10:37:48.911699 T10010A00 Write-Data Control setpoint: 10.00
  873. 10:37:49.025423 Error 03
  874. 10:37:49.891019 T10010A00 Write-Data Control setpoint: 10.00
  875. 10:37:50.872954 T10010A00 Write-Data Control setpoint: 10.00
  876. 10:37:50.990990 BD0010A00 Write-Ack Control setpoint: 10.00
  877. 10:37:51.898488 T00110000 Read-Data Relative modulation level: 0.00
  878. 10:37:52.012227 BC0110000 Read-Ack Relative modulation level: 0.00
  879. 10:37:52.891864 T80000200 Read-Data Status: 00000010 00000000
  880. 10:37:52.999517 B40000200 Read-Ack Status: 00000010 00000000
  881. 10:37:53.892763 T80190000 Read-Data Boiler water temperature: 0.00
  882. 10:37:53.945904 BC0193E00 Read-Ack Boiler water temperature: 62.00
  883. 10:37:54.917319 T10010A00 Write-Data Control setpoint: 10.00
  884. 10:37:55.016813 BD0010A00 Write-Ack Control setpoint: 10.00
  885. 10:37:55.912969 T00110000 Read-Data Relative modulation level: 0.00
  886. 10:37:55.968199 BC0110000 Read-Ack Relative modulation level: 0.00
  887. 10:37:56.887479 T801C0000 Read-Data Return water temperature: 0.00
  888. 10:37:56.990993 BC01C2C00 Read-Ack Return water temperature: 44.00
  889. 10:37:57.910087 T80190000 Read-Data Boiler water temperature: 0.00
  890. 10:37:58.000450 BC0193E00 Read-Ack Boiler water temperature: 62.00
  891. 10:37:58.888473 T10010A00 Write-Data Control setpoint: 10.00
  892. 10:37:59.001652 BD0010A00 Write-Ack Control setpoint: 10.00
  893. 10:37:59.892257 T801A0000 Read-Data DHW temperature: 0.00
  894. 10:37:59.946905 BC01A3100 Read-Ack DHW temperature: 49.00
  895. 10:38:00.905778 T001B0000 Read-Data Outside temperature: 0.00
  896. 10:38:01.017355 B401BE0FF Read-Ack Outside temperature: -31.00
  897. 10:38:01.895552 T00120000 Read-Data CH water pressure: 0.00
  898. 10:38:02.004922 B40120166 Read-Ack CH water pressure: 1.40
  899. 10:38:02.893677 T80000200 Read-Data Status: 00000010 00000000
  900. 10:38:02.952930 B40000260 Read-Ack Status: 00000010 01100000
  901. 10:38:03.895825 T80190000 Read-Data Boiler water temperature: 0.00
  902. 10:38:03.941664 BC0193E00 Read-Ack Boiler water temperature: 62.00
  903. 10:38:04.903231 T10010A00 Write-Data Control setpoint: 10.00
  904. 10:38:05.019763 BD0010A00 Write-Ack Control setpoint: 10.00
  905. 10:38:05.884245 T10383FFF Write-Data DHW setpoint: 64.00
  906. 10:38:05.996083 BD0383FFF Write-Ack DHW setpoint: 64.00
  907. 10:38:06.876714 T90395AFC Write-Data Max CH water setpoint: 90.98
  908. 10:38:07.000663 Error 04
  909. 10:38:07.015908 E50395AF8
  910. 10:38:07.901963 T80190000 Read-Data Boiler water temperature: 0.00
  911. 10:38:08.002041 BC0193E00 Read-Ack Boiler water temperature: 62.00
  912. 10:38:08.887543 T10010A00 Write-Data Control setpoint: 10.00
  913. 10:38:08.940165 BD0010A00 Write-Ack Control setpoint: 10.00
  914. 10:38:09.909091 T90395AFC Write-Data Max CH water setpoint: 90.98
  915. 10:38:10.011478 B50395AFC Write-Ack Max CH water setpoint: 90.98
  916. 10:38:10.910154 T00090000 Read-Data Remote override room setpoint: 0.00
  917. 10:38:10.925879 R00050000 Read-Data Application-specific flags: 00000000 0
  918. 10:38:11.890649 T00090000 Read-Data Remote override room setpoint: 0.00
  919. 10:38:11.897474 R00050000 Read-Data Application-specific flags: 00000000 0
  920. 10:38:11.952781 BC005C000 Read-Ack Application-specific flags: 11000000 0
  921. 10:38:12.013860 AC0090000 Read-Ack Remote override room setpoint: 0.00
  922. 10:38:12.862576 T80000200 Read-Data Status: 00000010 00000000
  923. 10:38:12.981001 B40000200 Read-Ack Status: 00000010 00000000
  924. 10:38:13.922145 T80190000 Read-Data Boiler water temperature: 0.00
  925. 10:38:13.980265 Error 03
  926. 10:38:14.883407 T80190000 Read-Data Boiler water temperature: 0.00
  927. 10:38:15.903055 T80190000 Read-Data Boiler water temperature: 0.00
  928. 10:38:16.019295 BC0193E00 Read-Ack Boiler water temperature: 62.00
  929. 10:38:16.893363 T10010A00 Write-Data Control setpoint: 10.00
  930. 10:38:16.950928 BD0010A00 Write-Ack Control setpoint: 10.00
  931. 10:38:17.874007 T80190000 Read-Data Boiler water temperature: 0.00
  932. 10:38:17.989343 BC0193E00 Read-Ack Boiler water temperature: 62.00
  933. 10:38:18.904399 T10010A00 Write-Data Control setpoint: 10.00
  934. 10:38:19.000641 BD0010A00 Write-Ack Control setpoint: 10.00
  935. 10:38:19.882030 T80640000 Read-Data Remote override function: 00000000
  936. 10:38:19.991687 B70640000 Unk-DataId Remote override function: 00000000
  937. 10:38:19.995053 A40640000 Read-Ack Remote override function: 00000000
  938. 10:38:20.871940 T00110000 Read-Data Relative modulation level: 0.00
  939. 10:38:20.968846 BC0110000 Read-Ack Relative modulation level: 0.00
  940. 10:38:21.898636 T1018152E Write-Data Room temperature: 21.18
  941. 10:38:21.999654 BF0180000 Unk-DataId Room temperature: 0.00
  942. 10:38:22.886470 T80000200 Read-Data Status: 00000010 00000000
  943. 10:38:22.984613 B40000200 Read-Ack Status: 00000010 00000000
  944. 10:38:23.889580 T80190000 Read-Data Boiler water temperature: 0.00
  945. 10:38:23.942857 BC0193E00 Read-Ack Boiler water temperature: 62.00
  946. 10:38:24.898508 T10010A00 Write-Data Control setpoint: 10.00
  947. 10:38:24.990888 BD0010A00 Write-Ack Control setpoint: 10.00
  948. 10:38:25.887706 T00110000 Read-Data Relative modulation level: 0.00
  949. 10:38:25.945689 BC0110000 Read-Ack Relative modulation level: 0.00
  950. 10:38:26.863075 T90101480 Write-Data Room setpoint: 20.50
  951. 10:38:26.976077 B70100000 Unk-DataId Room setpoint: 0.00
  952. 10:38:26.979827 AD0100000 Write-Ack Room setpoint: 0.00
  953. 10:38:27.899269 T80190000 Read-Data Boiler water temperature: 0.00
  954. 10:38:28.011363 Error 04
  955. 10:38:28.018403 EC0193A00
  956. 10:38:28.872277 T80190000 Read-Data Boiler water temperature: 0.00
  957. 10:38:29.902983 T80190000 Read-Data Boiler water temperature: 0.00
  958. 10:38:29.989448 BC0193E00 Read-Ack Boiler water temperature: 62.00
  959. 10:38:30.938452 T10010A00 Write-Data Control setpoint: 10.00
  960. 10:38:31.015270 BD0010A00 Write-Ack Control setpoint: 10.00
  961. 10:38:31.900073 T90148A23 Write-Data Day of week and time of day: Thu 10:35
  962. 10:38:31.969366 Error 03
  963. 10:38:32.918432 T80000200 Read-Data Status: 00000010 00000000
  964. 10:38:32.978755 B40000200 Read-Ack Status: 00000010 00000000
  965. 10:38:33.895201 T80190000 Read-Data Boiler water temperature: 0.00
  966. 10:38:33.963476 BC0193E00 Read-Ack Boiler water temperature: 62.00
  967. 10:38:34.876558 T10010A00 Write-Data Control setpoint: 10.00
  968. 10:38:34.982360 BD0010A00 Write-Ack Control setpoint: 10.00
  969. 10:38:35.905824 T00110000 Read-Data Relative modulation level: 0.00
  970. 10:38:36.876460 T00110000 Read-Data Relative modulation level: 0.00
  971. 10:38:36.978215 BC0110000 Read-Ack Relative modulation level: 0.00
  972. 10:38:37.914694 T80190000 Read-Data Boiler water temperature: 0.00
  973. 10:38:37.973641 BC0193E00 Read-Ack Boiler water temperature: 62.00
  974. 10:38:38.893488 T10010A00 Write-Data Control setpoint: 10.00
  975. 10:38:38.991293 BD0010A00 Write-Ack Control setpoint: 10.00
  976. 10:38:39.879571 T90148A23 Write-Data Day of week and time of day: Thu 10:35
  977. 10:38:39.976402 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  978. 10:38:39.980449 A50148A23 Write-Ack Day of week and time of day: Thu 10:35
  979. 10:38:40.882080 T801C0000 Read-Data Return water temperature: 0.00
  980. 10:38:40.979711 B401C2B00 Read-Ack Return water temperature: 43.00
  981. 10:38:41.916529 T801A0000 Read-Data DHW temperature: 0.00
  982. 10:38:42.032434 Error 03
  983. 10:38:42.891772 T80000200 Read-Data Status: 00000010 00000000
  984. 10:38:43.862879 T80000200 Read-Data Status: 00000010 00000000
  985. 10:38:43.965615 B40000200 Read-Ack Status: 00000010 00000000
  986. 10:38:44.916999 T80190000 Read-Data Boiler water temperature: 0.00
  987. 10:38:44.992103 BC0193E00 Read-Ack Boiler water temperature: 62.00
  988. 10:38:45.889831 T10010A00 Write-Data Control setpoint: 10.00
  989. 10:38:45.988984 BD0010A00 Write-Ack Control setpoint: 10.00
  990. 10:38:46.917832 T00110000 Read-Data Relative modulation level: 0.00
  991. 10:38:47.011814 BC0110000 Read-Ack Relative modulation level: 0.00
  992. 10:38:47.901044 T80190000 Read-Data Boiler water temperature: 0.00
  993. 10:38:47.956611 BC0193E00 Read-Ack Boiler water temperature: 62.00
  994. 10:38:48.873580 T10010A00 Write-Data Control setpoint: 10.00
  995. 10:38:48.979509 BD0010A00 Write-Ack Control setpoint: 10.00
  996. 10:38:49.901653 T801A0000 Read-Data DHW temperature: 0.00
  997. 10:38:50.902656 T801A0000 Read-Data DHW temperature: 0.00
  998. 10:38:51.005915 BC01A3100 Read-Ack DHW temperature: 49.00
  999. 10:38:51.883406 T001B0000 Read-Data Outside temperature: 0.00
  1000. 10:38:52.007233 B401BE0FF Read-Ack Outside temperature: -31.00
  1001. 10:38:52.869126 T80000200 Read-Data Status: 00000010 00000000
  1002. 10:38:52.979448 BC00002E0 Read-Ack Status: 00000010 11100000
  1003. 10:38:53.910806 T80190000 Read-Data Boiler water temperature: 0.00
  1004. 10:38:54.010491 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1005. 10:38:54.891250 T10010A00 Write-Data Control setpoint: 10.00
  1006. 10:38:54.945104 BD0010A00 Write-Ack Control setpoint: 10.00
  1007. 10:38:55.862259 T00110000 Read-Data Relative modulation level: 0.00
  1008. 10:38:55.962660 BC0110000 Read-Ack Relative modulation level: 0.00
  1009. 10:38:56.917178 T00120000 Read-Data CH water pressure: 0.00
  1010. 10:38:57.884609 T80190000 Read-Data Boiler water temperature: 0.00
  1011. 10:38:57.982010 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1012. 10:38:58.916706 T10010A00 Write-Data Control setpoint: 10.00
  1013. 10:38:59.010746 BD0010A00 Write-Ack Control setpoint: 10.00
  1014. 10:38:59.888767 T00120000 Read-Data CH water pressure: 0.00
  1015. 10:39:00.001504 Error 04
  1016. 10:39:00.005040 E40920166
  1017. 10:39:00.880571 T00120000 Read-Data CH water pressure: 0.00
  1018. 10:39:01.897123 T00120000 Read-Data CH water pressure: 0.00
  1019. 10:39:01.994306 B40120166 Read-Ack CH water pressure: 1.40
  1020. 10:39:02.879230 T80000200 Read-Data Status: 00000010 00000000
  1021. 10:39:02.996575 B40000260 Read-Ack Status: 00000010 01100000
  1022. 10:39:03.870177 T80000200 Read-Data Status: 00000010 00000000
  1023. 10:39:03.936052 B40000260 Read-Ack Status: 00000010 01100000
  1024. 10:39:04.939197 T80190000 Read-Data Boiler water temperature: 0.00
  1025. 10:39:05.011556 Error 04
  1026. 10:39:05.016618 EC0193E01
  1027. 10:39:05.891237 T80190000 Read-Data Boiler water temperature: 0.00
  1028. 10:39:05.941850 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1029. 10:39:06.925653 T10010A00 Write-Data Control setpoint: 10.00
  1030. 10:39:07.000133 Error 04
  1031. 10:39:07.004690 E90010A00
  1032. 10:39:07.907912 T10010A00 Write-Data Control setpoint: 10.00
  1033. 10:39:08.913341 T80190000 Read-Data Boiler water temperature: 0.00
  1034. 10:39:09.013717 Error 03
  1035. 10:39:09.882865 T80190000 Read-Data Boiler water temperature: 0.00
  1036. 10:39:09.995874 Error 04
  1037. 10:39:09.998891 EC0193E02
  1038. 10:39:10.901047 T80190000 Read-Data Boiler water temperature: 0.00
  1039. 10:39:10.980463 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1040. 10:39:11.898110 T10010A00 Write-Data Control setpoint: 10.00
  1041. 10:39:12.011549 BD0010A00 Write-Ack Control setpoint: 10.00
  1042. 10:39:12.889600 T10383FFF Write-Data DHW setpoint: 64.00
  1043. 10:39:12.998518 BD0383FFF Write-Ack DHW setpoint: 64.00
  1044. 10:39:13.870991 T80000200 Read-Data Status: 00000010 00000000
  1045. 10:39:13.978561 Error 04
  1046. 10:39:13.982138 EC10002E0
  1047. 10:39:14.900241 T80000200 Read-Data Status: 00000010 00000000
  1048. 10:39:14.995372 BC00002E0 Read-Ack Status: 00000010 11100000
  1049. 10:39:15.889101 T80190000 Read-Data Boiler water temperature: 0.00
  1050. 10:39:15.994560 Error 03
  1051. 10:39:16.900703 T80190000 Read-Data Boiler water temperature: 0.00
  1052. 10:39:17.887464 T80190000 Read-Data Boiler water temperature: 0.00
  1053. 10:39:17.987069 Error 04
  1054. 10:39:17.993924 EC0593E00
  1055. 10:39:18.905871 T80190000 Read-Data Boiler water temperature: 0.00
  1056. 10:39:19.880200 T80190000 Read-Data Boiler water temperature: 0.00
  1057. 10:39:20.912541 T80190000 Read-Data Boiler water temperature: 0.00
  1058. 10:39:21.883246 T80190000 Read-Data Boiler water temperature: 0.00
  1059. 10:39:22.916738 T80190000 Read-Data Boiler water temperature: 0.00
  1060. 10:39:23.015671 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1061. 10:39:23.901767 T80000200 Read-Data Status: 00000010 00000000
  1062. 10:39:24.004368 B40000200 Read-Ack Status: 00000010 00000000
  1063. 10:39:24.894203 T80190000 Read-Data Boiler water temperature: 0.00
  1064. 10:39:25.893525 T80190000 Read-Data Boiler water temperature: 0.00
  1065. 10:39:26.873355 T80190000 Read-Data Boiler water temperature: 0.00
  1066. 10:39:26.973240 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1067. 10:39:27.915050 T10010A00 Write-Data Control setpoint: 10.00
  1068. 10:39:28.880410 T80190000 Read-Data Boiler water temperature: 0.00
  1069. 10:39:29.903771 T80190000 Read-Data Boiler water temperature: 0.00
  1070. 10:39:30.006812 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1071. 10:39:30.905295 T10010A00 Write-Data Control setpoint: 10.00
  1072. 10:39:31.008068 BD0010A00 Write-Ack Control setpoint: 10.00
  1073. 10:39:31.885784 T90395AFC Write-Data Max CH water setpoint: 90.98
  1074. 10:39:31.985348 B50395AFC Write-Ack Max CH water setpoint: 90.98
  1075. 10:39:32.872992 T00090000 Read-Data Remote override room setpoint: 0.00
  1076. 10:39:32.878793 R00050000 Read-Data Application-specific flags: 00000000 0
  1077. 10:39:33.889112 T80000200 Read-Data Status: 00000010 00000000
  1078. 10:39:33.993029 BC00002E0 Read-Ack Status: 00000010 11100000
  1079. 10:39:34.883651 T80190000 Read-Data Boiler water temperature: 0.00
  1080. 10:39:34.976396 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1081. 10:39:35.914767 T10010A00 Write-Data Control setpoint: 10.00
  1082. 10:39:36.885219 T10010A00 Write-Data Control setpoint: 10.00
  1083. 10:39:36.985424 BD0010A00 Write-Ack Control setpoint: 10.00
  1084. 10:39:37.872105 T00090000 Read-Data Remote override room setpoint: 0.00
  1085. 10:39:37.872641 R00050000 Read-Data Application-specific flags: 00000000 0
  1086. 10:39:37.981986 BC0050000 Read-Ack Application-specific flags: 00000000 0
  1087. 10:39:37.982716 AC0090000 Read-Ack Remote override room setpoint: 0.00
  1088. 10:39:38.904363 T80190000 Read-Data Boiler water temperature: 0.00
  1089. 10:39:39.000039 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1090. 10:39:39.892375 T10010A00 Write-Data Control setpoint: 10.00
  1091. 10:39:40.003241 BD0010A00 Write-Ack Control setpoint: 10.00
  1092. 10:39:40.874826 T80640000 Read-Data Remote override function: 00000000
  1093. 10:39:40.929625 B70640000 Unk-DataId Remote override function: 00000000
  1094. 10:39:40.991132 A40640000 Read-Ack Remote override function: 00000000
  1095. 10:39:41.892856 T00110000 Read-Data Relative modulation level: 0.00
  1096. 10:39:41.997970 BC0110000 Read-Ack Relative modulation level: 0.00
  1097. 10:39:42.876287 T9018152A Write-Data Room temperature: 21.16
  1098. 10:39:43.926645 T80000200 Read-Data Status: 00000010 00000000
  1099. 10:39:43.977848 B40000200 Read-Ack Status: 00000010 00000000
  1100. 10:39:44.897386 T80190000 Read-Data Boiler water temperature: 0.00
  1101. 10:39:44.956457 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1102. 10:39:45.879760 T10010A00 Write-Data Control setpoint: 10.00
  1103. 10:39:45.991089 Error 03
  1104. 10:39:46.896178 T10010A00 Write-Data Control setpoint: 10.00
  1105. 10:39:47.012552 BD0010A00 Write-Ack Control setpoint: 10.00
  1106. 10:39:47.881769 T00110000 Read-Data Relative modulation level: 0.00
  1107. 10:39:47.977214 BC0110000 Read-Ack Relative modulation level: 0.00
  1108. 10:39:48.916456 T80190000 Read-Data Boiler water temperature: 0.00
  1109. 10:39:49.025839 Error 03
  1110. 10:39:49.884289 T80190000 Read-Data Boiler water temperature: 0.00
  1111. 10:39:50.873591 T80190000 Read-Data Boiler water temperature: 0.00
  1112. 10:39:50.983664 BC0193E00 Read-Ack Boiler water temperature: 62.00
  1113. 10:39:51.910931 T10010A00 Write-Data Control setpoint: 10.00
  1114. 10:39:52.005235 BD0010A00 Write-Ack Control setpoint: 10.00
  1115. 10:39:52.892404 T9018152A Write-Data Room temperature: 21.16
  1116. 10:39:53.005770 Error 04
  1117. 10:39:53.009411 EF0380000
  1118. 10:39:53.878718 T80000200 Read-Data Status: 00000010 00000000
  1119. 10:39:54.901369 T80000200 Read-Data Status: 00000010 00000000
  1120. 10:39:54.968448 B40000200 Read-Ack Status: 00000010 00000000
  1121. 10:39:55.884726 T80190000 Read-Data Boiler water temperature: 0.00
  1122. 10:39:55.941394 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1123. 10:39:56.902279 T10010A00 Write-Data Control setpoint: 10.00
  1124. 10:39:57.894411 T10010A00 Write-Data Control setpoint: 10.00
  1125. 10:39:57.943499 BD0010A00 Write-Ack Control setpoint: 10.00
  1126. 10:39:58.877212 T80190000 Read-Data Boiler water temperature: 0.00
  1127. 10:39:58.978017 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1128. 10:39:59.892083 T10010A00 Write-Data Control setpoint: 10.00
  1129. 10:40:00.021419 Error 03
  1130. 10:40:00.879724 T10010A00 Write-Data Control setpoint: 10.00
  1131. 10:40:01.895194 T10010A00 Write-Data Control setpoint: 10.00
  1132. 10:40:01.996838 BD0010A00 Write-Ack Control setpoint: 10.00
  1133. 10:40:02.885668 T00110000 Read-Data Relative modulation level: 0.00
  1134. 10:40:02.987778 BC0110000 Read-Ack Relative modulation level: 0.00
  1135. 10:40:03.865381 T80000200 Read-Data Status: 00000010 00000000
  1136. 10:40:03.964338 B40000200 Read-Ack Status: 00000010 00000000
  1137. 10:40:04.907522 T80190000 Read-Data Boiler water temperature: 0.00
  1138. 10:40:04.966880 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1139. 10:40:05.890737 T10010A00 Write-Data Control setpoint: 10.00
  1140. 10:40:05.991610 BD0010A00 Write-Ack Control setpoint: 10.00
  1141. 10:40:06.865134 T10383FFF Write-Data DHW setpoint: 64.00
  1142. 10:40:06.966994 BD0383FFF Write-Ack DHW setpoint: 64.00
  1143. 10:40:07.894643 T90395AFC Write-Data Max CH water setpoint: 90.98
  1144. 10:40:08.004511 B50395AFC Write-Ack Max CH water setpoint: 90.98
  1145. 10:40:08.899968 T80190000 Read-Data Boiler water temperature: 0.00
  1146. 10:40:08.950758 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1147. 10:40:09.861793 T10010A00 Write-Data Control setpoint: 10.00
  1148. 10:40:09.979472 BD0010A00 Write-Ack Control setpoint: 10.00
  1149. 10:40:10.903050 T00090000 Read-Data Remote override room setpoint: 0.00
  1150. 10:40:11.898988 T00090000 Read-Data Remote override room setpoint: 0.00
  1151. 10:40:11.954389 BF0090000 Unk-DataId Remote override room setpoint: 0.00
  1152. 10:40:12.030975 AC0090000 Read-Ack Remote override room setpoint: 0.00
  1153. 10:40:12.869214 T80640000 Read-Data Remote override function: 00000000
  1154. 10:40:12.969603 B70640000 Unk-DataId Remote override function: 00000000
  1155. 10:40:12.982879 A40640000 Read-Ack Remote override function: 00000000
  1156. 10:40:13.908928 T80000200 Read-Data Status: 00000010 00000000
  1157. 10:40:14.020707 Error 04
  1158. 10:40:14.024285 E40010200
  1159. 10:40:14.909804 T80000200 Read-Data Status: 00000010 00000000
  1160. 10:40:15.916227 T80000200 Read-Data Status: 00000010 00000000
  1161. 10:40:15.965311 B40000200 Read-Ack Status: 00000010 00000000
  1162. 10:40:16.897394 T80190000 Read-Data Boiler water temperature: 0.00
  1163. 10:40:16.956527 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1164. 10:40:17.867517 T10010A00 Write-Data Control setpoint: 10.00
  1165. 10:40:18.041645 Error 03
  1166. 10:40:18.924467 T80190000 Read-Data Boiler water temperature: 0.00
  1167. 10:40:18.970568 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1168. 10:40:19.910188 T10010A00 Write-Data Control setpoint: 10.00
  1169. 10:40:19.965630 BD0010A00 Write-Ack Control setpoint: 10.00
  1170. 10:40:20.921417 T00110000 Read-Data Relative modulation level: 0.00
  1171. 10:40:21.052988 Error 03
  1172. 10:40:21.893546 T00110000 Read-Data Relative modulation level: 0.00
  1173. 10:40:22.865346 T00110000 Read-Data Relative modulation level: 0.00
  1174. 10:40:22.962899 BC0110000 Read-Ack Relative modulation level: 0.00
  1175. 10:40:23.897198 T80000200 Read-Data Status: 00000010 00000000
  1176. 10:40:23.999608 B40000200 Read-Ack Status: 00000010 00000000
  1177. 10:40:24.885068 T80190000 Read-Data Boiler water temperature: 0.00
  1178. 10:40:24.995611 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1179. 10:40:25.870785 T10010A00 Write-Data Control setpoint: 10.00
  1180. 10:40:25.969518 BD0010A00 Write-Ack Control setpoint: 10.00
  1181. 10:40:26.904720 T00110000 Read-Data Relative modulation level: 0.00
  1182. 10:40:26.957911 BC0110000 Read-Ack Relative modulation level: 0.00
  1183. 10:40:27.877198 T1018152E Write-Data Room temperature: 21.18
  1184. 10:40:27.976255 BF0180000 Unk-DataId Room temperature: 0.00
  1185. 10:40:28.879935 T80190000 Read-Data Boiler water temperature: 0.00
  1186. 10:40:28.982025 BC0193D00 Read-Ack Boiler water temperature: 61.00
  1187. 10:40:29.896136 T10010A00 Write-Data Control setpoint: 10.00
  1188. 10:40:29.997327 BD0010A00 Write-Ack Control setpoint: 10.00
  1189. 10:40:30.900484 T90101480 Write-Data Room setpoint: 20.50
  1190. 10:40:30.958897 B70100000 Unk-DataId Room setpoint: 0.00
  1191. 10:40:31.018220 AD0100000 Write-Ack Room setpoint: 0.00
  1192. 10:40:31.872899 T10148A24 Write-Data Day of week and time of day: Thu 10:36
  1193. 10:40:31.986858 Error 03
  1194. 10:40:32.905966 T10148A24 Write-Data Day of week and time of day: Thu 10:36
  1195. 10:40:32.962949 BF0140000 Unk-DataId Day of week and time of day: Unk 00:00
  1196. 10:40:33.020426 AD0148A24 Write-Ack Day of week and time of day: Thu 10:36