- ===|smartctl -l selftest|===
- smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.7-1-ARCH] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF READ SMART DATA SECTION ===
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed: read failure 90% 872 12158888
- ===|smartctl -a|===
- smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.7-1-ARCH] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Laptop SSHD
- Device Model: ST500LM000-1EJ162
- Serial Number: W370PG3B
- LU WWN Device Id: 5 000c50 06a99ff55
- Firmware Version: LVD2
- User Capacity: 500,107,862,016 bytes [500 GB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Thu Apr 10 00:13:31 2014 UTC
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 121) The previous self-test completed having
- the read element of the test failed.
- Total time to complete Offline
- data collection: ( 139) seconds.
- Offline data collection
- capabilities: (0x73) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- No Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 99) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x1081) SCT Status supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 115 086 006 Pre-fail Always - 97696434
- 3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 287
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 8
- 7 Seek_Error_Rate 0x000f 065 060 030 Pre-fail Always - 73065894546
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 873
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 249
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 3147
- 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 4295032834
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 061 047 045 Old_age Always - 39 (Min/Max 27/39)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 43
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 1801
- 194 Temperature_Celsius 0x0022 039 053 000 Old_age Always - 39 (0 9 0 0 0)
- 197 Current_Pending_Sector 0x0012 094 094 000 Old_age Always - 1136
- 198 Offline_Uncorrectable 0x0010 094 094 000 Old_age Offline - 1136
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 3151 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 3151 occurred at disk power-on lifetime: 872 hours (36 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 a8 87 b9 00 Error: UNC at LBA = 0x00b987a8 = 12158888
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 00 c0 57 b5 40 00 00:00:31.944 READ FPDMA QUEUED
- 60 00 00 c0 56 b5 40 00 00:00:31.944 READ FPDMA QUEUED
- 60 00 00 c0 55 b5 40 00 00:00:31.944 READ FPDMA QUEUED
- 60 00 00 c0 54 b5 40 00 00:00:31.944 READ FPDMA QUEUED
- 60 00 00 c0 53 b5 40 00 00:00:31.944 READ FPDMA QUEUED
- Error 3150 occurred at disk power-on lifetime: 872 hours (36 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 f8 ca bd 00 Error: UNC at LBA = 0x00bdcaf8 = 12438264
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 80 30 c1 b7 40 00 00:00:20.359 READ FPDMA QUEUED
- 60 00 80 b0 c0 b7 40 00 00:00:20.359 READ FPDMA QUEUED
- 60 00 40 c8 ca bd 40 00 00:00:20.358 READ FPDMA QUEUED
- 60 00 40 a0 cc bd 40 00 00:00:20.357 READ FPDMA QUEUED
- 60 00 00 b0 bf b7 40 00 00:00:20.357 READ FPDMA QUEUED
- Error 3149 occurred at disk power-on lifetime: 872 hours (36 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 a8 87 b9 00 Error: UNC at LBA = 0x00b987a8 = 12158888
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 40 5a 0d 7c 40 00 00:04:15.690 READ FPDMA QUEUED
- 60 00 40 da a0 b5 40 00 00:04:15.690 READ FPDMA QUEUED
- 60 00 39 28 9a dc 43 00 00:04:15.690 READ FPDMA QUEUED
- 60 00 08 d2 a0 b5 40 00 00:04:15.690 READ FPDMA QUEUED
- 61 00 08 88 3d a6 40 00 00:04:15.690 WRITE FPDMA QUEUED
- Error 3148 occurred at disk power-on lifetime: 872 hours (36 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 a8 87 b9 00 Error: UNC at LBA = 0x00b987a8 = 12158888
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 08 30 ea aa 40 00 00:04:11.656 READ FPDMA QUEUED
- 60 00 08 80 ea aa 40 00 00:04:11.656 READ FPDMA QUEUED
- 60 00 08 40 fc ad 40 00 00:04:11.655 READ FPDMA QUEUED
- 60 00 08 c8 b8 ab 40 00 00:04:11.655 READ FPDMA QUEUED
- 60 00 40 72 a0 b5 40 00 00:04:11.646 READ FPDMA QUEUED
- Error 3147 occurred at disk power-on lifetime: 872 hours (36 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 a8 87 b9 00 Error: UNC at LBA = 0x00b987a8 = 12158888
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 20 09 3a 50 40 00 00:03:10.775 READ FPDMA QUEUED
- 60 00 13 e1 98 dc 43 00 00:03:10.775 READ FPDMA QUEUED
- 60 00 20 3a ed 4d 40 00 00:03:10.775 READ FPDMA QUEUED
- 61 00 08 48 3e a6 40 00 00:03:10.775 WRITE FPDMA QUEUED
- 60 00 08 28 bf 98 40 00 00:03:10.775 READ FPDMA QUEUED
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed: read failure 90% 872 12158888
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.