- dclib.lua — shared control math library for dc1 and dcmaster
- Require this from both scripts: local dclib = require("dclib")
- ]]
- local M = {}
- M.MAX_GATE_FLOW = 2147000000
- M.WARMUP_INPUT_RF_T = 5000000
- M.PROBE_INPUT_RF_T = 1
- M.PROBE_TICK_S = 0.05
- M.MC_TICKS_PER_S = 20
- M.FUEL_CUTOFF = 0.875
- -- EMA_ALPHA removed: output gate is set directly each tick, no smoothing.
- function M.safeDiv(a, b, fb)
- a, b = tonumber(a) or 0, tonumber(b) or 0
- if b == 0 then return fb or 0 end
- return a / b
- end
- function M.clamp(v, lo, hi)
- v = tonumber(v) or lo
- if v ~= v then return lo end
- return math.max(lo, math.min(hi, v))
- end
- function M.computeControl(info, targetTemp, targetShield, multiplier)
- if not info then return {} end
- local targetTemp50 = math.min((targetTemp / 10000) * 50, 99)
- local coreSat = M.safeDiv(info.energySaturation, info.maxEnergySaturation, 0)
- local convLVL = (M.safeDiv(info.fuelConversion, info.maxFuelConversion, 0) * 1.3) - 0.3
- local targetTempResist = (targetTemp50^4) / (100 - targetTemp50)
- local targetTempExpo = -(targetTempResist * convLVL) - 1000*convLVL + targetTempResist
- local term1 = 1334.1 - (3 * targetTempExpo)
- local term2 = (1200690 - (2700 * targetTempExpo))^2
- local inner = (-4*term1^3 + term2)
- local sqrtInner = inner >= 0 and inner^0.5 or 0
- local term3 = ((-1350*targetTempExpo) + sqrtInner/2 + 600345)^(1/3)
- local targetNegCSat = -(term1/(3*term3)) - (term3/3)
- local targetCoreSat = 1 - (targetNegCSat / 99)
- local targetSat = targetCoreSat * info.maxEnergySaturation
- local satError = info.energySaturation - targetSat
- local tempDrainFactor = 0
- local t = info.temperature
- if t > 8000 then tempDrainFactor = 1 + (t-8000)^2 * 0.0000025
- elseif t > 2000 then tempDrainFactor = 1
- elseif t > 1000 then tempDrainFactor = (t-1000)/1000
- end
- local baseMaxRFt = (info.maxEnergySaturation / 1000) * multiplier * 1.5
- -- A phase-aligned DE core starts each tick at its previous post-drain field.
- local field = info.fieldStrength
- local capacity = info.maxFieldStrength
- if info.fieldSampleAfterDrain and info.fieldSampleStrength
- and info.fieldSampleCapacity and info.fieldSampleCapacity > 0 then
- field = info.fieldSampleStrength
- capacity = info.fieldSampleCapacity
- end
- local fsError = capacity * targetShield - field
- local headroom = capacity - field
- local reqInput = math.min(M.safeDiv(capacity * info.fieldDrainRate, headroom, 0), headroom)
- local outputNeeded = math.min(satError, info.maxEnergySaturation / 40) + (info.generationRate or 0)
- local inputCmd = math.min(fsError + reqInput, capacity)
- return {
- satError = satError,
- fieldStrengthError = fsError,
- requiredInput = reqInput,
- outputNeeded = outputNeeded,
- inputCommand = inputCmd,
- targetCoreSat = targetCoreSat,
- tempDrainFactor = tempDrainFactor,
- convLVL = convLVL,
- targetTempResist = targetTempResist,
- }
- end
- function M.readInfo(reactor)
- local ok, s = pcall(function() return reactor.getReactorInfo() end)
- if not ok or not s then return nil end
- return {
- status = tostring(s.status or "unknown"),
- temperature = tonumber(s.temperature) or 0,
- fieldStrength = tonumber(s.fieldStrength) or 0,
- maxFieldStrength = tonumber(s.maxFieldStrength) or 0,
- fieldSampleStrength = tonumber(s.fieldSampleStrength),
- fieldSampleCapacity = tonumber(s.fieldSampleCapacity),
- fieldSampleTick = tonumber(s.fieldSampleTick),
- fieldSampleAfterDrain = s.fieldSampleAfterDrain == true,
- energySaturation = tonumber(s.energySaturation) or 0,
- maxEnergySaturation = tonumber(s.maxEnergySaturation) or 0,
- fuelConversion = tonumber(s.fuelConversion) or 0,
- maxFuelConversion = tonumber(s.maxFuelConversion) or 0,
- fuelConversionRate = tonumber(s.fuelConversionRate) or 0,
- generationRate = tonumber(s.generationRate) or 0,
- fieldDrainRate = tonumber(s.fieldDrainRate) or 0,
- }
- end
- function M.rawSetGate(g, v)
- if not g then return false end
- v = math.floor(M.clamp(v or 0, 0, M.MAX_GATE_FLOW) + 0.5) + 0.0
- pcall(function() g.setOverrideEnabled(true) end)
- return pcall(function() g.setFlowOverride(v) end)
- end
- function M.rawGetGate(g)
- if not g then return 0 end
- local ok, v = pcall(function() return g.getFlowOverride() end)
- if ok then return tonumber(v) or 0 end
- ok, v = pcall(function() return g.getFlow() end)
- if ok then return tonumber(v) or 0 end
- return 0
- end
- function M.formatRF(n)
- n = tonumber(n) or 0
- if math.abs(n) >= 1e9 then return string.format("%.2f GRF/t", n/1e9) end
- if math.abs(n) >= 1e6 then return string.format("%.2f MRF/t", n/1e6) end
- if math.abs(n) >= 1e3 then return string.format("%.2f kRF/t", n/1e3) end
- return string.format("%d RF/t", math.floor(n+0.5))
- end
- function M.formatPct(p)
- return string.format("%.1f%%", M.clamp(tonumber(p) or 0, 0, 1)*100)
- end
- function M.formatETA(sec)
- sec = tonumber(sec)
- if not sec or sec ~= sec or sec == math.huge or sec < 0 then return "--:--:--" end
- if sec > 359999 then return ">99h" end
- sec = math.floor(sec + 0.5)
- local h = math.floor(sec / 3600)
- local m = math.floor((sec % 3600) / 60)
- local s = sec % 60
- return string.format("%d:%02d:%02d", h, m, s)
- end
- return M
Advertisement