- root@pve1:~# smartctl -a /dev/sda
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf
- Device Model: ST12000VN0008-2PH103
- Serial Number: ZTN10BYB
- LU WWN Device Id: 5 000c50 0e3fcbee7
- Firmware Version: SC61
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-4 (minor revision not indicated)
- SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:13 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1075) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 064 044 Pre-fail Always - 1607576
- 3 Spin_Up_Time 0x0003 091 090 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 36
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 082 060 045 Pre-fail Always - 173547264
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 2311
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 35
- 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 069 049 040 Old_age Always - 31 (Min/Max 29/37)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 32
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 610
- 194 Temperature_Celsius 0x0022 031 040 000 Old_age Always - 31 (0 20 0 0 0)
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 2187 (116 166 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11358640099
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 75120161976
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2311 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@pve1:~# smartctl -a /dev/sda
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf
- Device Model: ST12000VN0008-2PH103
- Serial Number: ZTN10BYB
- LU WWN Device Id: 5 000c50 0e3fcbee7
- Firmware Version: SC61
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-4 (minor revision not indicated)
- SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:16 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1075) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 064 044 Pre-fail Always - 1608624
- 3 Spin_Up_Time 0x0003 091 090 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 36
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 082 060 045 Pre-fail Always - 173547302
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 2311
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 35
- 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 069 049 040 Old_age Always - 31 (Min/Max 29/37)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 32
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 610
- 194 Temperature_Celsius 0x0022 031 040 000 Old_age Always - 31 (0 20 0 0 0)
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 2187 (127 43 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11358641059
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 75120162064
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2311 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@pve1:~# smartctl -a /dev/sdd
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf Pro
- Device Model: ST12000NE0008-1ZF101
- Serial Number: ZLW2AHZZ
- LU WWN Device Id: 5 000c50 0a44c811d
- Firmware Version: DN01
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:18 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1110) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 081 064 044 Pre-fail Always - 140142568
- 3 Spin_Up_Time 0x0003 088 087 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 60
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 084 060 045 Pre-fail Always - 255882454
- 9 Power_On_Hours 0x0032 095 095 000 Old_age Always - 4432
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 62
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 069 055 040 Old_age Always - 31 (Min/Max 30/38)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 126
- 193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 2703
- 194 Temperature_Celsius 0x0022 031 045 000 Old_age Always - 31 (0 18 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 004 001 000 Old_age Always - 140142568
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 3549h+12m+18.614s
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 39469268740
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 158797689871
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 4432 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@pve1:~# smartctl -a /dev/sde
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf
- Device Model: ST12000VN0008-2PH103
- Serial Number: ZTN11XB9
- LU WWN Device Id: 5 000c50 0e443a131
- Firmware Version: SC61
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-4 (minor revision not indicated)
- SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:24 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1096) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 077 064 044 Pre-fail Always - 55970664
- 3 Spin_Up_Time 0x0003 091 090 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 11
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 082 060 045 Pre-fail Always - 171891368
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 2308
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 11
- 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 071 050 040 Old_age Always - 29 (Min/Max 28/35)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 9
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 583
- 194 Temperature_Celsius 0x0022 029 040 000 Old_age Always - 29 (0 21 0 0 0)
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 2185 (104 251 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11359459123
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 75661173721
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2308 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@pve1:~# smartctl -a /dev/sdg
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf
- Device Model: ST12000VN0008-2PH103
- Serial Number: ZTN10CFR
- LU WWN Device Id: 5 000c50 0e3fcad49
- Firmware Version: SC61
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-4 (minor revision not indicated)
- SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:25 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1094) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 079 064 044 Pre-fail Always - 73085576
- 3 Spin_Up_Time 0x0003 091 090 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 25
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 082 060 045 Pre-fail Always - 177286782
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 2310
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 25
- 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 068 049 040 Old_age Always - 32 (Min/Max 30/39)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 22
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 599
- 194 Temperature_Celsius 0x0022 032 042 000 Old_age Always - 32 (0 20 0 0 0)
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 2186 (179 233 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11359116731
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 75678805405
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2310 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@pve1:~# smartctl -a /dev/sdh
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf
- Device Model: ST12000VN0008-2PH103
- Serial Number: ZTN123ZP
- LU WWN Device Id: 5 000c50 0e44450cb
- Firmware Version: SC61
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-4 (minor revision not indicated)
- SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:42 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1098) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 080 064 044 Pre-fail Always - 99375208
- 3 Spin_Up_Time 0x0003 091 090 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 11
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 082 060 045 Pre-fail Always - 170833286
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 2308
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 11
- 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 071 049 040 Old_age Always - 29 (Min/Max 28/37)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 9
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 587
- 194 Temperature_Celsius 0x0022 029 040 000 Old_age Always - 29 (0 21 0 0 0)
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 2182 (46 54 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11356240027
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 75215369657
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2308 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@pve1:~# smartctl -a /dev/sdj
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf
- Device Model: ST12000VN0008-2PH103
- Serial Number: ZTN10CEQ
- LU WWN Device Id: 5 000c50 0e3fca44d
- Firmware Version: SC61
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-4 (minor revision not indicated)
- SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:44 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1102) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 080 064 044 Pre-fail Always - 108970792
- 3 Spin_Up_Time 0x0003 091 090 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 25
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 082 060 045 Pre-fail Always - 173787463
- 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 2310
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 25
- 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 068 050 040 Old_age Always - 32 (Min/Max 30/39)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 22
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 597
- 194 Temperature_Celsius 0x0022 032 041 000 Old_age Always - 32 (0 20 0 0 0)
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 2186 (24 62 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11358891179
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 75226680405
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 2310 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@pve1:~# smartctl -a /dev/sdk
- smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.30-2-pve] (local build)
- Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate IronWolf
- Device Model: ST12000VN0007-2GS116
- Serial Number: ZJV26VZL
- LU WWN Device Id: 5 000c50 0b2aee4c8
- Firmware Version: SC60
- User Capacity: 12,000,138,625,024 bytes [12.0 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 7200 rpm
- Form Factor: 3.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-3 T13/2161-D revision 5
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Tue Jan 3 01:56:54 2023 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 567) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: (1125) minutes.
- Conveyance self-test routine
- recommended polling time: ( 2) minutes.
- SCT capabilities: (0x50bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 084 064 044 Pre-fail Always - 236536320
- 3 Spin_Up_Time 0x0003 088 086 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 276
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 087 060 045 Pre-fail Always - 553399182
- 9 Power_On_Hours 0x0032 059 059 000 Old_age Always - 35992
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 143
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
- 188 Command_Timeout 0x0032 099 098 000 Old_age Always - 59
- 190 Airflow_Temperature_Cel 0x0022 070 048 040 Old_age Always - 30 (Min/Max 27/35)
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1424
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 1698
- 194 Temperature_Celsius 0x0022 030 049 000 Old_age Always - 30 (0 17 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 004 001 000 Old_age Always - 236536320
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 93
- 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 35200 (212 144 0)
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 125133638614
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 297601481605
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 35992 -
- # 2 Short offline Completed without error 00% 34037 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.