Guest User

sudo smartctl --all /dev/sdd

a guest
Jan 17th, 2020
178
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
Bash 7.59 KB | None | 0 0
  1. smartctl 7.0 2018-12-30 r4883 [x86_64-linux-4.19.91-1-MANJARO] (local build)
  2. Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family:     Toshiba 3.5" DT01ACA... Desktop HDD
  6. Device Model:     TOSHIBA DT01ACA300
  7. Serial Number:    446LH8GGS
  8. LU WWN Device Id: 5 000039 ff4d67f84
  9. Firmware Version: MX6OABB0
  10. User Capacity:    3 000 592 982 016 bytes [3,00 TB]
  11. Sector Sizes:     512 bytes logical, 4096 bytes physical
  12. Rotation Rate:    7200 rpm
  13. Form Factor:      3.5 inches
  14. Device is:        In smartctl database [for details use: -P show]
  15. ATA Version is:   ATA8-ACS T13/1699-D revision 4
  16. SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  17. Local Time is:    Sat Jan 18 00:02:32 2020 MSK
  18. SMART support is: Available - device has SMART capability.
  19. SMART support is: Enabled
  20.  
  21. === START OF READ SMART DATA SECTION ===
  22. SMART overall-health self-assessment test result: PASSED
  23.  
  24. General SMART Values:
  25. Offline data collection status:  (0x84) Offline data collection activity
  26.                     was suspended by an interrupting command from host.
  27.                     Auto Offline Data Collection: Enabled.
  28. Self-test execution status:      (   0) The previous self-test routine completed
  29.                     without error or no self-test has ever
  30.                     been run.
  31. Total time to complete Offline
  32. data collection:        (21648) seconds.
  33. Offline data collection
  34. capabilities:            (0x5b) SMART execute Offline immediate.
  35.                     Auto Offline data collection on/off support.
  36.                     Suspend Offline collection upon new
  37.                     command.
  38.                     Offline surface scan supported.
  39.                     Self-test supported.
  40.                     No Conveyance Self-test supported.
  41.                     Selective Self-test supported.
  42. SMART capabilities:            (0x0003) Saves SMART data before entering
  43.                     power-saving mode.
  44.                     Supports SMART auto save timer.
  45. Error logging capability:        (0x01) Error logging supported.
  46.                     General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time:    (   1) minutes.
  49. Extended self-test routine
  50. recommended polling time:    ( 361) minutes.
  51. SCT capabilities:          (0x003d) SCT Status supported.
  52.                     SCT Error Recovery Control supported.
  53.                     SCT Feature Control supported.
  54.                     SCT Data Table supported.
  55.  
  56. SMART Attributes Data Structure revision number: 16
  57. Vendor Specific SMART Attributes with Thresholds:
  58. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  59.  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       0
  60.  2 Throughput_Performance  0x0005   140   140   054    Pre-fail  Offline      -       67
  61.  3 Spin_Up_Time            0x0007   156   156   024    Pre-fail  Always       -       416 (Average 321)
  62.  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       80
  63.  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       2
  64.  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  65.  8 Seek_Time_Performance   0x0005   121   121   020    Pre-fail  Offline      -       34
  66.  9 Power_On_Hours          0x0012   098   098   000    Old_age   Always       -       17851
  67. 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
  68. 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       77
  69. 192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       213
  70. 193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       -       213
  71. 194 Temperature_Celsius     0x0002   153   153   000    Old_age   Always       -       39 (Min/Max 18/53)
  72. 196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       2
  73. 197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0
  74. 198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
  75. 199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0
  76.  
  77. SMART Error Log Version: 1
  78. ATA Error Count: 3
  79.     CR = Command Register [HEX]
  80.     FR = Features Register [HEX]
  81.     SC = Sector Count Register [HEX]
  82.     SN = Sector Number Register [HEX]
  83.     CL = Cylinder Low Register [HEX]
  84.     CH = Cylinder High Register [HEX]
  85.     DH = Device/Head Register [HEX]
  86.     DC = Device Command Register [HEX]
  87.     ER = Error register [HEX]
  88.     ST = Status register [HEX]
  89. Powered_Up_Time is measured from power on, and printed as
  90. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  91. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  92.  
  93. Error 3 occurred at disk power-on lifetime: 17740 hours (739 days + 4 hours)
  94.  When the command that caused the error occurred, the device was active or idle.
  95.  
  96.  After command completion occurred, registers were:
  97.  ER ST SC SN CL CH DH
  98.  -- -- -- -- -- -- --
  99.  40 51 68 98 d0 31 0e  Error: UNC 104 sectors at LBA = 0x0e31d098 = 238145688
  100.  
  101.  Commands leading to the command that caused the error were:
  102.  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  103.  -- -- -- -- -- -- -- --  ----------------  --------------------
  104.  25 00 00 00 d0 31 e0 00      03:39:56.970  READ DMA EXT
  105.  25 00 00 00 cf 31 e0 00      03:39:56.945  READ DMA EXT
  106.  25 00 00 00 ce 31 e0 00      03:39:56.944  READ DMA EXT
  107.  25 00 00 00 cd 31 e0 00      03:39:56.943  READ DMA EXT
  108.  25 00 00 00 cc 31 e0 00      03:39:56.943  READ DMA EXT
  109.  
  110. Error 2 occurred at disk power-on lifetime: 17677 hours (736 days + 13 hours)
  111.  When the command that caused the error occurred, the device was active or idle.
  112.  
  113.  After command completion occurred, registers were:
  114.  ER ST SC SN CL CH DH
  115.  -- -- -- -- -- -- --
  116.  40 51 68 98 d0 31 0e  Error: UNC at LBA = 0x0e31d098 = 238145688
  117.  
  118.  Commands leading to the command that caused the error were:
  119.  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  120.  -- -- -- -- -- -- -- --  ----------------  --------------------
  121.  60 00 a8 00 d0 31 40 00      02:27:30.540  READ FPDMA QUEUED
  122.  60 00 a0 00 cf 31 40 00      02:27:30.539  READ FPDMA QUEUED
  123.  60 00 98 00 ce 31 40 00      02:27:30.538  READ FPDMA QUEUED
  124.  60 00 90 00 cd 31 40 00      02:27:30.537  READ FPDMA QUEUED
  125.  60 00 88 00 cc 31 40 00      02:27:30.537  READ FPDMA QUEUED
  126.  
  127. Error 1 occurred at disk power-on lifetime: 16298 hours (679 days + 2 hours)
  128.  When the command that caused the error occurred, the device was active or idle.
  129.  
  130.  After command completion occurred, registers were:
  131.  ER ST SC SN CL CH DH
  132.  -- -- -- -- -- -- --
  133.  40 51 08 98 1b bc 04  Error: UNC at LBA = 0x04bc1b98 = 79436696
  134.  
  135.  Commands leading to the command that caused the error were:
  136.  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  137.  -- -- -- -- -- -- -- --  ----------------  --------------------
  138.  60 c0 30 e0 1f bc 40 08   1d+02:59:44.955  READ FPDMA QUEUED
  139.  60 c0 28 e0 1e bc 40 08   1d+02:59:44.955  READ FPDMA QUEUED
  140.  60 40 20 a0 1f bc 40 08   1d+02:59:44.953  READ FPDMA QUEUED
  141.  60 40 18 60 1e bc 40 08   1d+02:59:44.952  READ FPDMA QUEUED
  142.  60 00 10 60 1d bc 40 08   1d+02:59:44.952  READ FPDMA QUEUED
  143.  
  144. SMART Self-test log structure revision number 1
  145. No self-tests have been logged.  [To run self-tests, use: smartctl -t]
  146.  
  147. SMART Selective self-test log data structure revision number 1
  148. SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  149.    1        0        0  Not_testing
  150.    2        0        0  Not_testing
  151.    3        0        0  Not_testing
  152.    4        0        0  Not_testing
  153.    5        0        0  Not_testing
  154. Selective self-test flags (0x0):
  155.  After scanning selected spans, do NOT read-scan remainder of disk.
  156. If Selective self-test is pending on power-up, resume after 0 minute delay.