  1. ; Configuration file for Duet WiFi (firmware version 2.03)
  2. ; executed by the firmware on start-up
  3. ;
  4. ; generated by RepRapFirmware Configuration Tool v2.1.3 on Fri Nov 29 2019 15:21:21 GMT+0100 (Central European Standard Time)
  5.  
  6. ; General preferences
  7. G90                                     ; send absolute coordinates...
  8. M83                                     ; ...but relative extruder moves
  9. M550 P"My Printer"                      ; set printer name
  10.  
  11. ; Network
  12. M551 P"nerdyprint"                      ; set password
  13. M552 S1                                 ; enable network
  14. M586 P0 S1                              ; enable HTTP
  15. M586 P1 S0                              ; disable FTP
  16. M586 P2 S0                              ; disable Telnet
  17.  
  18. ; Drives
  19. M569 P0 S1                              ; physical drive 0 goes forwards
  20. M569 P1 S1                              ; physical drive 1 goes forwards
  21. M569 P2 S1                              ; physical drive 2 goes forwards
  22. M569 P3 S1                              ; physical drive 3 goes forwards
  23. M584 X0 Y1 Z2 E3                        ; set drive mapping
  24. M350 X16 Y16 Z16 E16 I1                 ; configure microstepping with interpolation
  25. M92 X80.00 Y80.00 Z4000.00 E420.00      ; set steps per mm
  26. M566 X900.00 Y900.00 Z12.00 E120.00     ; set maximum instantaneous speed changes (mm/min)
  27. M203 X6000.00 Y6000.00 Z180.00 E1200.00 ; set maximum speeds (mm/min)
  28. M201 X500.00 Y500.00 Z20.00 E250.00     ; set accelerations (mm/s^2)
  29. M906 X800 Y800 Z800 E800 I30            ; set motor currents (mA) and motor idle factor in per cent
  30. M84 S30                                 ; Set idle timeout
  31.  
  32. ; Axis Limits
  33. M208 X0 Y0 Z0 S1                        ; set axis minima
  34. M208 X160 Y160 Z160 S0                  ; set axis maxima
  35.  
  36. ; Endstops
  37. M574 X1 Y2 S1                           ; set active high endstops
  38. M574 Z1 S2                              ; set endstops controlled by probe
  39.  
  40. ; Z-Probe
  41. M558 P1 H5 F120 T6000                   ; set Z probe type to unmodulated and the dive height + speeds
  42. G31 P500 X0 Y0 Z2.5                     ; set Z probe trigger value, offset and trigger height
  43. M557 X15:160 Y15:160 S20                ; define mesh grid
  44.  
  45. ; Heaters
  46. M305 P0 T100000 B4138 R4700             ; set thermistor + ADC parameters for heater 0
  47. M143 H0 S120                            ; set temperature limit for heater 0 to 120C
  48. M305 P1 T100000 B4138 R4700             ; set thermistor + ADC parameters for heater 1
  49. M143 H1 S280                            ; set temperature limit for heater 1 to 280C
  50.  
  51. ; Fans
  52. M106 P0 S0 I0 F500 H-1                  ; set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off
  53. M106 P1 S1 I0 F500 H1 T45               ; set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on
  54.  
  55. ; Tools
  56. M563 P0 D0 H1 F0                        ; define tool 0
  57. G10 P0 X0 Y0 Z0                         ; set tool 0 axis offsets
  58. G10 P0 R0 S0                            ; set initial tool 0 active and standby temperatures to 0C
  59.  
  60. ; Custom settings are not defined