- -- MIB created by Sunwave
- -- version 1.0, created on july 20, 2013.
- -- released on Oct.28, 2016
- SUNWAVE-DAS-MA2-MIB DEFINITIONS ::= BEGIN
- IMPORTS
- OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY,
- IpAddress,Integer32,Unsigned32,enterprises,TimeTicks
- FROM SNMPv2-SMI
- TEXTUAL-CONVENTION, MacAddress,DisplayString
- FROM SNMPv2-TC;
- sunwave OBJECT IDENTIFIER ::= { enterprises 31731}
- p2CrossFire OBJECT IDENTIFIER ::= { sunwave 8}
- masterA2 OBJECT IDENTIFIER ::= { p2CrossFire 1}
- devlist OBJECT IDENTIFIER ::= { masterA2 1}
- chanBaseBandPower OBJECT IDENTIFIER ::= { systemInfo 16}
- a2Chan1InputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port1 Input BaseBand power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 21 }
- a2Chan2InputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port2 Input BaseBand power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 22 }
- a2Chan3InputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port3 Input BaseBand power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 23 }
- a2Chan4InputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port4 Input BaseBand power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 24 }
- auChan1OutputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port1 Output power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 25 }
- auChan2OutputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port2 Output power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 26 }
- auChan3OutputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port3 Output power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 27 }
- auChan4OutputBaseBandPower OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.1dBm"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port4 Output power value
- unit:0.1dbm, rate:10,
- for example: the value of 80 actually means 8dbm. "
- ::= { chanBaseBandPower 28 }
- -- devlist
- devNumTotal OBJECT-TYPE
- SYNTAX INTEGER(0..255)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "numbers of device of whole system,"
- ::= { devlist 1 }
- devListTable OBJECT-TYPE
- SYNTAX SEQUENCE OF DevListEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "devce list info of whole system,"
- ::= { devlist 2 }
- devListEntry OBJECT-TYPE
- SYNTAX DevListEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry containing one device informations."
- INDEX
- { devIndexNum }
- ::= { devListTable 1 }
- DevListEntry ::= SEQUENCE
- {
- devIndexNum INTEGER,
- devID INTEGER,
- devType INTEGER,
- devConnectStat INTEGER,
- devRoute IpAddress,
- devLocation DisplayString
- }
- devIndexNum OBJECT-TYPE
- SYNTAX INTEGER(0..255)
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "index of slave device within one system"
- ::= { devListEntry 1 }
- devID OBJECT-TYPE
- SYNTAX INTEGER(0..254)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "Device sub ID"
- ::= { devListEntry 2 }
- devType OBJECT-TYPE
- SYNTAX INTEGER
- {
- eu-o(227),
- mastera2(230),
- slavea2(231),
- eu(242),
- ru(243),
- hru(245),
- mru(246),
- xpru(251),
- n2ru(235),
- h2ru(233)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- ""
- ::= { devListEntry 3 }
- devConnectStat OBJECT-TYPE
- SYNTAX INTEGER
- {
- disconnect(0),
- connect(1)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "0 disconnect, 1 connect"
- ::= { devListEntry 4 }
- devRoute OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "To show to which optical port is the device connected"
- ::= { devListEntry 5 }
- devLocation OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "show device Location"
- ::= { devListEntry 6 }
- -- AlarmTable
- alarms OBJECT IDENTIFIER ::= { masterA2 2}
- alarmTable OBJECT-TYPE
- SYNTAX SEQUENCE OF AlarmEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Configure each possible alarm on the device (trap, relay out,
- severity...)."
- ::= { alarms 1 }
- alarmEntry OBJECT-TYPE
- SYNTAX AlarmEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "An entry containing one alarm informations."
- INDEX
- { alarmId }
- ::= { alarmTable 1 }
- AlarmEntry ::= SEQUENCE
- {
- alarmId INTEGER,
- alarmSeverity INTEGER,
- alarmStat INTEGER,
- alarmType DisplayString
- }
- alarmId OBJECT-TYPE
- SYNTAX INTEGER(1..200)
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "3:Movement Alarm,
- 4:Over-temperature Alarm,
- 7~10:LO1~4 Unlocked Alarm,
- 20~25:OP1~6 Transceiver Failure Alarm,
- 26:OP-AU1 Transceiver Failure Alarm,
- 27:OP-AU7 Transceiver Failure Alarm,
- 38~41:External Alarm1~4,
- 44:Open Case Alarm,
- 51~54:radioModule1~4 DL ALC Over Range Alarm,
- 55~58:radioModule1 Port1~4 DL Under Input-power Alarm,
- 59~62:radioModule1 Port1~4 DL Over Input-power Alarm,
- 63~66:radioModule2 Port1~4 DL Under Input-power Alarm,
- 67~70:radioModule2 Port1~4 DL Over Input-power Alarm,
- 71~74:radioModule3 Port1~4 DL Under Input-power Alarm,
- 75~78:radioModule3 Port1~4 DL Over Input-power Alarm,
- 79~82:radioModule4 Port1~4 DL Under Input-power Alarm,
- 83~86:radioModule4 Port1~4 DL Over Input-power Alarm,
- 95:Band Configuration Failure Alarm,
- "
- ::= { alarmEntry 1 }
- alarmSeverity OBJECT-TYPE
- SYNTAX INTEGER
- {
- disable(0),
- warning(2),
- minor(3),
- major(4),
- critical(5)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Alarm's level,if set it 0,device will not report this alarm"
- ::= { alarmEntry 2 }
- alarmStat OBJECT-TYPE
- SYNTAX INTEGER
- {
- normal(0),
- alarm(1)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "Alarm's status"
- ::= { alarmEntry 3 }
- alarmType OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "Alarm's name;
- refer to the description of alarmId
- "
- ::= { alarmEntry 4 }
- alarmTHD OBJECT IDENTIFIER ::= { alarms 2}
- overTemperatureThreshold OBJECT-TYPE
- SYNTAX INTEGER (-55..125)
- UNITS "Celsius"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of Over temperature Alarm.
- Alarm when device temperature over this threshold "
- ::= { alarmTHD 1 }
- radioModule1InputPowerUnderThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule1 down link under input-power alarm.
- Alarm when the input power level of radioModule1 is under this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 2 }
- radioModule2InputPowerUnderThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule2 down link under input-power alarm.
- Alarm when the input power level of radioModule2 is under this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 3 }
- radioModule3InputPowerUnderThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule3 down link under input-power alarm.
- Alarm when the input power level of radioModule3 is under this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 4}
- radioModule4InputPowerUnderThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule4 down link under input-power alarm.
- Alarm when the input power level of radioModule4 is under this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 5 }
- radioModule1InputPowerOverThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule1 down link over input-power alarm.
- Alarm when the input power level of radioModule1 is over this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 6 }
- radioModule2InputPowerOverThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule2 down link over input-power alarm.
- Alarm when the input power level of radioModule2 is over this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 7 }
- radioModule3InputPowerOverThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule3 down link over input-power alarm,
- Alarm when the input power level of radioModule3 is over this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 8 }
- radioModule4InputPowerOverThreshold OBJECT-TYPE
- SYNTAX Integer32 (-350..150)
- UNITS "0.1dBm"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "the threshold of radioModule4 down link over input-power alarm,
- Alarm when the input power level of radioModule4 is over this threshold.
- unit:0.1dBm, rate:10,
- for example: the value of 200 that sent or received actually means 20dBm.
- "
- ::= { alarmTHD 9 }
- externalAlarm1ModeSelection OBJECT-TYPE
- SYNTAX INTEGER
- {
- normally_closed(0),
- normally_open(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- External Alarm 1 Mode Selection
- 0-normally_closed
- 1-normally_open
- "
- ::= { alarmTHD 10 }
- externalAlarm2ModeSelection OBJECT-TYPE
- SYNTAX INTEGER
- {
- normally_closed(0),
- normally_open(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- External Alarm 2 Mode Selection
- 0-normally_closed
- 1-normally_open
- "
- ::= { alarmTHD 11 }
- externalAlarm3ModeSelection OBJECT-TYPE
- SYNTAX INTEGER
- {
- normally_closed(0),
- normally_open(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- External Alarm 3 Mode Selection
- 0-normally_closed
- 1-normally_open
- "
- ::= { alarmTHD 12 }
- externalAlarm4ModeSelection OBJECT-TYPE
- SYNTAX INTEGER
- {
- normally_closed(0),
- normally_open(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- External Alarm 4 Mode Selection
- 0-normally_closed
- 1-normally_open
- "
- ::= { alarmTHD 13 }
- externalAlarm1Label OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- External Alarm 1 Remarks "
- ::= { alarmTHD 14 }
- externalAlarm2Label OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- External Alarm 2 Remarks "
- ::= { alarmTHD 15 }
- externalAlarm3Label OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- External Alarm 3 Remarks "
- ::= { alarmTHD 16 }
- externalAlarm4Label OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- External Alarm 3 Remarks "
- ::= { alarmTHD 17 }
- -- trap
- traps OBJECT IDENTIFIER ::= { masterA2 3}
- alarmTrap NOTIFICATION-TYPE
- OBJECTS
- { trapAlarmId,trapAlarmType, trapAlarmStat, trapAlarmSeverity, trapAlarmModuleID, trapAlarmCTime,trapAlarmMTime }
- STATUS current
- DESCRIPTION
- "Trap send in an alarm rising edge."
- ::= { traps 0 1 }
- trapAlarmObjects OBJECT IDENTIFIER ::= { traps 1 }
- trapAlarmId OBJECT-TYPE
- SYNTAX INTEGER(1..200)
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- "<<<<The ID of the alarm (see alarmId)>>>>"
- ::= { trapAlarmObjects 1 }
- trapAlarmType OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- "<<<<The name of the alarm (see alarmType)>>>>"
- ::= { trapAlarmObjects 2 }
- trapAlarmStat OBJECT-TYPE
- SYNTAX INTEGER
- {
- normal(0),
- alarm(1)
- }
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- "Alarm Status"
- ::= { trapAlarmObjects 3 }
- trapAlarmSeverity OBJECT-TYPE
- SYNTAX INTEGER
- {
- disable(0),
- warning(2),
- minor(3),
- major(4),
- critical(5)
- }
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- "Alarm severity"
- ::= { trapAlarmObjects 4 }
- trapAlarmModuleType OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- "there are 4 kinds of type in one system - Master C-HUB, Slave C-HUB, E-HUB and HP-RU"
- ::= { trapAlarmObjects 5 }
- trapAlarmModuleID OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- " Unique module identifier
- (based on this field the operator should be able to identify
- which module of which system is sending this alarm)
- #deviceID#device sub ID"
- ::= { trapAlarmObjects 6 }
- trapAlarmCTime OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- " Alarm creation time stamp (when the alarm was initiated).
- format: yyyy-mm-mm-dd hh:mm:ss, such as , 2013-07-20 16:07:50
- "
- ::= { trapAlarmObjects 7 }
- trapAlarmMTime OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- " Alarm modification time stamp (when the alarm was last modified).
- format: yyyy-mm-mm-dd hh:mm:ss, such as , 2013-07-20 16:07:50
- "
- ::= { trapAlarmObjects 8 }
- trapAlarmLocation OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- "The location of the device"
- ::= { trapAlarmObjects 9 }
- trapAlarmSiteID OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION
- "The SiteID of the device"
- ::= { trapAlarmObjects 10 }
- systemInformation OBJECT IDENTIFIER ::= { masterA2 4}
- elementIdentification OBJECT IDENTIFIER ::= { systemInformation 1}
- vendor OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- " Code to distinguish from different manufacturers"
- ::= { elementIdentification 1 }
- elementModelNumber OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "element model number of the device"
- ::= { elementIdentification 2 }
- elementSerialNumber OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "element serial number of the device"
- ::= { elementIdentification 3}
- softwareVersion OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- " Current version of remote monitoring software. "
- ::= { elementIdentification 4 }
- snmpVersion OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- " Current version of remote monitoring software. "
- ::= { elementIdentification 5 }
- deviceID OBJECT-TYPE
- SYNTAX DisplayString(SIZE(8))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "The unique identification number of site in the system"
- ::= { elementIdentification 6 }
- deviceSubID OBJECT-TYPE
- SYNTAX INTEGER(0)
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Number assigned by the system to distinguish the subsets in the same site "
- ::= { elementIdentification 7 }
- installedLocationLabel OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- Device Location "
- ::= { elementIdentification 8 }
- siteNameLabel OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..40))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- Site Name Label
- "
- ::= { elementIdentification 9 }
- systemDateAndTime OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- device's current date and time.
- format: yyyy-mm-mm-d hh:mm:ss, such as , 2013-07-20 16:07:50
- "
- ::= { elementIdentification 10 }
- oP1A2Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP1 Transceiver Serial Number "
- ::= { elementIdentification 16 }
- oP2Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP2 Transceiver Serial Number "
- ::= { elementIdentification 17 }
- oP3Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP3 Transceiver Serial Number "
- ::= { elementIdentification 18 }
- oP4Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP4 Transceiver Serial Number "
- ::= { elementIdentification 19 }
- oP5Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP5 Transceiver Serial Number "
- ::= { elementIdentification 20 }
- oP6Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP6 Transceiver Serial Number "
- ::= { elementIdentification 21 }
- a2_1Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP Au1 Transceiver Serial Number "
- ::= { elementIdentification 22 }
- a2_2Transceiver OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..16))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- OP Au2 Transceiver Serial Number "
- ::= { elementIdentification 23 }
- omtLogoutTime OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- ""
- ::= { elementIdentification 26 }
- masterA2APUSBPort OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Master A2 AP USB Port
- 0-off
- 1-ON
- "
- ::= { elementIdentification 27 }
- slaveLocalDebugPort OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Slave Local Debug Port
- 0-off
- 1-ON
- "
- ::= { elementIdentification 28 }
- -- network information
- wanIpSettings OBJECT IDENTIFIER ::= { systemInformation 2}
- protocol OBJECT-TYPE
- SYNTAX INTEGER
- {
- snmp(1),
- udp(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Protocol Select
- SNMP or UDP
- SNMP:1,UDP:2"
- ::= { wanIpSettings 1}
- nmsIpAddress OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "IP address of NMS."
- ::= { wanIpSettings 2 }
- nmsPortNumber OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "NMS Port Number"
- ::= { wanIpSettings 3}
- deviceIpAddr OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "IP address of device."
- ::= { wanIpSettings 7 }
- subnetMask OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- " Subnet Mask of device."
- ::= { wanIpSettings 8 }
- defaultGateway OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Default Gateway of device."
- ::= { wanIpSettings 9 }
- deviceRecvPortForUDP OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Device Port(UDP)"
- ::= { wanIpSettings 10}
- heartbeatClock OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Heartbeat Clock of Device
- unit:1s"
- ::= { wanIpSettings 11}
- -- sftpSettings
- sftpSettings OBJECT IDENTIFIER ::= { systemInformation 3}
- serverIpAddress OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "IP Address of the connected FTP Server for software upgrading."
- ::= { sftpSettings 1 }
- serverPortNumber OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Server Port (FTP)"
- ::= { sftpSettings 2}
- sftpAccountUsername OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Username for device logging in FTP Server"
- ::= { sftpSettings 3}
- sftpAccountPassword OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Password for device logging in FTP Server"
- ::= { sftpSettings 4}
- firmwareUpgradeFilepath OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..40))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Filepath(directory) for device acquiring upgrading file from FTP Server"
- ::= { sftpSettings 5}
- firmwareUpgradeFilename OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..40))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Filename of the awaiting upgrading software"
- ::= { sftpSettings 6}
- sftpFileTransferControl OBJECT-TYPE
- SYNTAX INTEGER
- {
- start (1),
- cancel(4)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Set 1 to start FTP Transmission and set 4 to cancel"
- ::= { sftpSettings 7}
- snmpSettings OBJECT IDENTIFIER ::= { systemInformation 4}
- securityUserName OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Security User Name"
- ::= { snmpSettings 1}
- authProtocol OBJECT-TYPE
- SYNTAX INTEGER
- {
- none(0),
- md5(1),
- sha(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "auth protocol"
- ::= { snmpSettings 2}
- authPassword OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Authentication Password"
- ::= { snmpSettings 3}
- privProtocol OBJECT-TYPE
- SYNTAX INTEGER
- {
- none(0),
- des(1),
- aes(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION " Privacy Protocol"
- ::= { snmpSettings 4}
- privPassword OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Privacy Password"
- ::= { snmpSettings 5}
- editUserConfirm OBJECT-TYPE
- SYNTAX INTEGER
- {
- confirm(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Edit User Confirm
- "
- ::= { snmpSettings 6 }
- protocol OBJECT-TYPE
- SYNTAX INTEGER
- {
- snmp(1),
- udp(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Protocol Select
- SNMP or UDP
- SNMP:1,UDP:2"
- ::= { snmpSettings 7}
- snmpTrapProtocol OBJECT-TYPE
- SYNTAX INTEGER
- {
- snnmpV2(1),
- snnmpV3(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "choose snmp trap protocol"
- ::= { snmpSettings 8}
- trapIpAddress1 OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "IP address of manager for getting trap information"
- ::= { snmpSettings 9 }
- trapIpAddress2 OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "IP address of manager for getting trap information"
- ::= { snmpSettings 10 }
- trapPort OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "port number of manager for getting trap information"
- ::= { snmpSettings 11}
- trapIpAddress1SecurityEngineID OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "v3 trap ip address 1 Security Engine ID"
- ::= { snmpSettings 12 }
- trapIpAddress2SecurityEngineID OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "v3 trap ip address 2 Security Engine ID"
- ::= { snmpSettings 13 }
- snmpv3resetUSM OBJECT-TYPE
- SYNTAX INTEGER
- {
- reset(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- reset to default user
- "
- ::= { snmpSettings 14 }
- resendEnable OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Resend Enable"
- ::= { snmpSettings 15 }
- resendInterval OBJECT-TYPE
- SYNTAX INTEGER{
- min_5(0),
- min_30(1),
- min_60(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Resend Interval"
- ::= { snmpSettings 16}
- community OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "community"
- ::= { snmpSettings 17 }
- deleteHistoryAlarm OBJECT-TYPE
- SYNTAX INTEGER
- {
- confirm(1)
- }
- MAX-ACCESS write-only
- STATUS current
- DESCRIPTION "
- Delete HistoryAlarm
- "
- ::= { snmpSettings 18 }
- systemInfo OBJECT IDENTIFIER ::= { masterA2 5}
- sysGeneral OBJECT IDENTIFIER ::= { systemInfo 5}
- elementOperatingTemperature OBJECT-TYPE
- SYNTAX Integer32
- UNITS "Celsius"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "device temperature"
- ::= { sysGeneral 1 }
- radioModule1Info OBJECT IDENTIFIER ::= { systemInfo 1}
- radioModule1RfSignalActive OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "RF signal switch of channel 1"
- ::= { radioModule1Info 1 }
- radioModule1UlAttenuation OBJECT-TYPE
- SYNTAX INTEGER(0..10)
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the up-link gain of channel 1.
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule1Info 2 }
- radioModule1DlAttenuation OBJECT-TYPE
- SYNTAX INTEGER(0..10)
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the down-link gain of channel 1
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule1Info 3 }
- radioModule1DigitalFilterBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The band width of channel1 RF signal .
- unit:0.001MHZ,
- rate:1000, for example: the value of 10000 actually means 10MHz .
- "
- ::= { radioModule1Info 4 }
- radioModule1UlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The up-link central frequence of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz "
- ::= { radioModule1Info 5 }
- radioModule1DlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The down-link central frequence of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz "
- ::= { radioModule1Info 6 }
- radioModule2Info OBJECT IDENTIFIER ::= { systemInfo 2}
- radioModule2RfSignalActive OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "RF signal switch of channel 2"
- ::= { radioModule2Info 1 }
- radioModule2UlAttenuation OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the up-link gain of channe2
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule2Info 2 }
- radioModule2DlAttenuation OBJECT-TYPE
- SYNTAX INTEGER (0..10)
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the down-link gain of channe2
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule2Info 3 }
- radioModule2DigitalFilterBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ "
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The band width of channel2 RF signal .
- unit:0.001MHZ,
- rate:1000, for example: the value of 10000 actually means 10MHz ."
- ::= { radioModule2Info 4 }
- radioModule2UlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The up-link central frequence of channel2.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz "
- ::= { radioModule2Info 5 }
- radioModule2DlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The down-link central frequence of channel2.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz "
- ::= { radioModule2Info 6 }
- radioModule3Info OBJECT IDENTIFIER ::= { systemInfo 3}
- radioModule3RfSignalActive OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "RF signal switch of channel 3"
- ::= { radioModule3Info 1 }
- radioModule3UlAttenuation OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the up-link gain of channe3
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule3Info 2 }
- radioModule3DlAttenuation OBJECT-TYPE
- SYNTAX INTEGER (0..10)
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the down-link gain of channe3
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule3Info 3 }
- radioModule3DigitalFilterBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The band width of channel3 RF signal .
- unit:0.001MHZ,
- rate:1000, for example: the value of 10000 actually means 10MHz .
- "
- ::= { radioModule3Info 4 }
- radioModule3UlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The up-link central frequence of channel 3.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz "
- ::= { radioModule3Info 5 }
- radioModule3DlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The down-link central frequence of channel3.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz "
- ::= { radioModule3Info 6 }
- radioModule4Info OBJECT IDENTIFIER ::= { systemInfo 4}
- radioModule4RfSignalActive OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "RF signal switch of channel 4"
- ::= { radioModule4Info 1 }
- radioModule4UlAttenuation OBJECT-TYPE
- SYNTAX INTEGER (0..10)
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the up-link gain of channel 4.
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule4Info 2 }
- radioModule4DlAttenuation OBJECT-TYPE
- SYNTAX INTEGER (0..10)
- UNITS "0.5dB"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "Increase the value to decrease the down-link gain of channe4
- unit:0.5dB,
- rate:2, for example: the value of 2 actually means 1dB.
- "
- ::= { radioModule4Info 3 }
- radioModule4DigitalFilterBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The band width of channel4 RF signal .
- unit:0.001MHZ,
- rate:1000, for example: the value of 10000 actually means 10MHz .
- "
- ::= { radioModule4Info 4}
- radioModule4UlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The up-link central frequence of channel4.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz "
- ::= { radioModule4Info 5 }
- radioModule4DlCentreFrequency OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The down-link central frequence of channel4.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4Info 6 }
- --bandConfiguration
- bandConfiguration OBJECT IDENTIFIER ::= { masterA2 7}
- systemDelay OBJECT IDENTIFIER ::= { bandConfiguration 1}
- delayAdjustmentMethod OBJECT-TYPE
- SYNTAX INTEGER
- {
- auto(0),
- trigger(1),
- manual(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Delay adjustment Method
- "
- ::= { systemDelay 1 }
- maxDelayMeasuredValue OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- Maximum Delay Measurement Value
- unit:0.01us,
- rate:100, for example: the value of 200 actually means 2us.
- "
- ::= { systemDelay 2 }
- maxDelayAdjustValue OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- Maximum Delay Adjustment Value
- unit:0.01us,
- rate:100, for example: the value of 200 actually means 2us.
- "
- ::= { systemDelay 3 }
- triggeredDelayActivation OBJECT-TYPE
- SYNTAX INTEGER
- {
- confirm(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Manual Delay Confirm
- delayType must be manual mode
- "
- ::= { systemDelay 4 }
- customizeDelayValue OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Customize Delay Value
- unit:0.01us,
- rate:100, for example: the value of 200 actually means 2us.
- "
- ::= { systemDelay 5 }
- tddMode OBJECT IDENTIFIER ::= { bandConfiguration 2}
- tddSwitch_5G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 5G TDD Switch
- 0-off
- 1-ON
- "
- ::= { tddMode 1 }
- syncStatus_5G OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- ""
- ::= { tddMode 2 }
- radioModule1_5G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 5G radioModule1
- 0-off
- 1-ON
- "
- ::= { tddMode 3 }
- radioModule2_5G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 5G radioModule2
- 0-off
- 1-ON
- "
- ::= { tddMode 4 }
- radioModule3_5G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 5G radioModule3
- 0-off
- 1-ON
- "
- ::= { tddMode 5 }
- radioModule4_5G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 5G radioModule4
- 0-off
- 1-ON
- "
- ::= { tddMode 6 }
- ssbType OBJECT-TYPE
- SYNTAX INTEGER
- {
- case_c(0),
- case_a(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- SSB Type
- 0-CASE_A
- 1-CASE_C
- "
- ::= { tddMode 7 }
- slotConfiguration_5G OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..40))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Slot Configuration"
- ::= { tddMode 8 }
- specialSlotsymbolFormat1 OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..10))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Special Slot symbol Format1"
- ::= { tddMode 9 }
- specialSlotsymbolFormat2 OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..10))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "Special Slot symbol Format1"
- ::= { tddMode 10 }
- sSB_ARFCN_5G OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 0:auto scan mode;
- else manual mode.
- "
- ::= { tddMode 11 }
- tddSwitch_4G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 4G TDD Switch
- 0-off
- 1-ON
- "
- ::= { tddMode 13 }
- syncStatus_4G OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- ""
- ::= { tddMode 14 }
- radioModule1_4G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 4G radioModule1
- 0-off
- 1-ON
- "
- ::= { tddMode 15 }
- radioModule2_4G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 4G radioModule2
- 0-off
- 1-ON
- "
- ::= { tddMode 16 }
- radioModule3_4G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 5G radioModule3
- 0-off
- 1-ON
- "
- ::= { tddMode 17 }
- radioModule4_4G OBJECT-TYPE
- SYNTAX INTEGER
- {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 4G radioModule4
- 0-off
- 1-ON
- "
- ::= { tddMode 18 }
- uLDLConfiguration OBJECT-TYPE
- SYNTAX INTEGER
- {
- confirRate0(0),
- confirRate1(1),
- confirRate2(2),
- confirRate3(3),
- confirRate4(4),
- confirRate5(5),
- confirRate6(6)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- UL-DL Configuration
- value:0,1,2,3,4,5,6
- "
- ::= { tddMode 19 }
- specialSubframeConfiguration OBJECT-TYPE
- SYNTAX INTEGER
- {
- specialSubframeRatio0(0),
- specialSubframeRatio1(1),
- specialSubframeRatio2(2),
- specialSubframeRatio3(3),
- specialSubframeRatio4(4),
- specialSubframeRatio5(5),
- specialSubframeRatio6(6),
- specialSubframeRatio7(7),
- specialSubframeRatio8(8)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Special Subframe Configuration
- value:0,1,2,3,4,5,6,7,8
- "
- ::= { tddMode 20 }
- ssb_arfcn_5G OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- 0:auto scan mode;
- else manual mode.
- "
- ::= { tddMode 21 }
- radioModule1bandConfig OBJECT IDENTIFIER ::= { bandConfiguration 3}
- radioModule2bandConfig OBJECT IDENTIFIER ::= { bandConfiguration 4}
- radioModule3bandConfig OBJECT IDENTIFIER ::= { bandConfiguration 5}
- radioModule4bandConfig OBJECT IDENTIFIER ::= { bandConfiguration 6}
- radioModule1InfoCheck OBJECT-TYPE
- SYNTAX INTEGER
- {
- valid(0),
- invalid(1)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " "
- ::= { radioModule1bandConfig 1 }
- radioModule1UlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The up-link frequence range lower limit of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 2 }
- radioModule1UlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The UP-link frequence range upper limit of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 3 }
- radioModule1DlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The down-link frequence range lower limit of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 4 }
- radioModule1DlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "The down-link frequence range upper limit of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 5 }
- radioModule1SignalBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "The carrier1 bandwidth of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 6 }
- radioModule1SignalULCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "The carrier1 up-link center frequence of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 8 }
- radioModule1SignalDLCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "The carrier1 down-link center frequence of channel1.
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 9 }
- radioModule1SignalTransBandwidthOccupied OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "channel1 transmission bandwidth occupied
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule1bandConfig 18 }
- radioModule2InfoCheck OBJECT-TYPE
- SYNTAX INTEGER
- {
- valid(0),
- invalid(1)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " "
- ::= { radioModule2bandConfig 1 }
- radioModule2UlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 2 }
- radioModule2UlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 3 }
- radioModule2DlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 4 }
- radioModule2DlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 5 }
- radioModule2SignalBandwidth OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 6 }
- radioModule2SignalULCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 8 }
- radioModule2SignalDLCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 9 }
- radioModule2SignalTransBandwidthOccupied OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "channel2 transmission bandwidth occupied
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule2bandConfig 18 }
- radioModule3InfoCheck OBJECT-TYPE
- SYNTAX INTEGER
- {
- valid(0),
- invalid(1)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " "
- ::= { radioModule3bandConfig 1 }
- radioModule3UlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 2 }
- radioModule3UlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 3 }
- radioModule3DlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 4 }
- radioModule3DlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 5 }
- radioModule3SignalBandwidth OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 6 }
- radioModule3SignalULCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 8 }
- radioModule3SignalDLCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 9 }
- radioModule3SignalTransBandwidthOccupied OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "channel3 transmission bandwidth occupied
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule3bandConfig 18 }
- radioModule4InfoCheck OBJECT-TYPE
- SYNTAX INTEGER
- {
- valid(0),
- invalid(1)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " "
- ::= { radioModule4bandConfig 1 }
- radioModule4UlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 2 }
- radioModule4UlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 3 }
- radioModule4DlFrequencyStart OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 4 }
- radioModule4DlFrequencyEnd OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 5 }
- radioModule4SignalBandwidth OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 6 }
- radioModule4SignalULCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 8 }
- radioModule4SignalDLCentreFrequency OBJECT-TYPE
- SYNTAX Integer32
- UNITS "0.001MHZ"
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 9 }
- radioModule4SignalTransBandwidthOccupied OBJECT-TYPE
- SYNTAX INTEGER
- UNITS "0.001MHZ"
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "channel4 transmission bandwidth occupied
- unit:0.001MHZ,
- rate:1000, for example: the value of 800000 actually means 800MHz.
- "
- ::= { radioModule4bandConfig 18 }
- inServiceBandwidth OBJECT IDENTIFIER ::= { bandConfiguration 7}
- bandConfigurationUpdate OBJECT-TYPE
- SYNTAX INTEGER
- {
- update(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION " "
- ::= { inServiceBandwidth 1 }
- elementSignalBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " Local Signal Bandwidth "
- ::= { inServiceBandwidth 2 }
- elementTransmissionBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " Local Transmission Bandwidth "
- ::= { inServiceBandwidth 3 }
- systemSignalBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " System Signal Bandwidth "
- ::= { inServiceBandwidth 4 }
- systemTransmissionBandwidth OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION " System Transmission Bandwidth "
- ::= { inServiceBandwidth 5 }
- ipTransmissionBandwidthSelect OBJECT-TYPE
- SYNTAX INTEGER
- {
- m_100(0),
- m_1000(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Gigabit mode
- 0-100M
- 1-1000M
- "
- ::= { inServiceBandwidth 6 }
- combiners OBJECT IDENTIFIER ::= { masterA2 8}
- general OBJECT IDENTIFIER ::= { combiners 1}
- radioModule1 OBJECT IDENTIFIER ::= { combiners 2}
- radioModule2 OBJECT IDENTIFIER ::= { combiners 3}
- radioModule3 OBJECT IDENTIFIER ::= { combiners 4}
- radioModule4 OBJECT IDENTIFIER ::= { combiners 5}
- attenuationControlMode OBJECT-TYPE
- SYNTAX INTEGER
- {
- manual(0),
- automatic(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Combiner Att Control Mode
- Automatic=1
- Manual=0
- "
- ::= { general 1 }
- automaticLevelInterval OBJECT-TYPE
- SYNTAX INTEGER
- {
- test60sec(0),
- hours6(1),
- hours12(2),
- hours24(3)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- Adjust Interval
- must be auto mode
- "
- ::= { general 2 }
- attenuationLevelReset OBJECT-TYPE
- SYNTAX INTEGER {
- reset(0)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "combiner attenuation reset"
- ::= { general 3 }
- radioModule1PowerSwitch OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "radioModule1 power switch"
- ::= { radioModule1 1 }
- radioModule1Port1InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port1 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm. "
- ::= { radioModule1 2}
- radioModule1Port2InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port2 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule1 3 }
- radioModule1Port3InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port3 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule1 4 }
- radioModule1Port4InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port4 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule1 5 }
- radioModule1Port1Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule1 6 }
- radioModule1Port2Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule1 7 }
- radioModule1Port3Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule1 8 }
- radioModule1Port4Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule1 9 }
- radioModule1Port1PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 input power distribution (%)
- unit:%,
- rate:1.
- "
- ::= { radioModule1 10 }
- radioModule1Port2PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule1 11 }
- radioModule1Port3PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule1 12 }
- radioModule1Port4PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule1 13 }
- radioModule1Port1Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Label "
- ::= { radioModule1 14 }
- radioModule1Port2Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Label "
- ::= { radioModule1 15 }
- radioModule1Port3Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Label "
- ::= { radioModule1 16 }
- radioModule1Port4Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 Label "
- ::= { radioModule1 17 }
- radioModule1SerialNumber OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- Module 1 Serial Number "
- ::= { radioModule1 18 }
- radioModule2PowerSwitch OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "radioModule2 power switch"
- ::= { radioModule2 1 }
- radioModule2Port1InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port1 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm. "
- ::= { radioModule2 2 }
- radioModule2Port2InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port2 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule2 3 }
- radioModule2Port3InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port3 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule2 4 }
- radioModule2Port4InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port4 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule2 5 }
- radioModule2Port1Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule2 6 }
- radioModule2Port2Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule2 7 }
- radioModule2Port3Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule2 8 }
- radioModule2Port4Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule2 9 }
- radioModule2Port1PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule2 10 }
- radioModule2Port2PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule2 11 }
- radioModule2Port3PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule2 12 }
- radioModule2Port4PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule2 13 }
- radioModule2Port1Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Label "
- ::= { radioModule2 14 }
- radioModule2Port2Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Label "
- ::= { radioModule2 15 }
- radioModule2Port3Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Label "
- ::= { radioModule2 16 }
- radioModule2Port4Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 Label "
- ::= { radioModule2 17 }
- radiomodule2SerialNumber OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- Module 2 Serial Number "
- ::= { radioModule2 18 }
- radioModule3PowerSwitch OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "radioModule3 power switch"
- ::= { radioModule3 1 }
- radioModule3Port1InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port1 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm. "
- ::= { radioModule3 2 }
- radioModule3Port2InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port2 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule3 3 }
- radioModule3Port3InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port3 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule3 4 }
- radioModule3Port4InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port4 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule3 5 }
- radioModule3Port1Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule3 6 }
- radioModule3Port2Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule3 7 }
- radioModule3Port3Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule3 8 }
- radioModule3Port4Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule3 9 }
- radioModule3Port1PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule3 10 }
- radioModule3Port2PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule3 11 }
- radioModule3Port3PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule3 12 }
- radioModule3Port4PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule3 13 }
- radioModule3Port1Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Label "
- ::= { radioModule3 14 }
- radioModule3Port2Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Label "
- ::= { radioModule3 15 }
- radioModule3Port3Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Label "
- ::= { radioModule3 16 }
- radioModule3Port4Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 Label "
- ::= { radioModule3 17 }
- radiomodule3SerialNumber OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- Module 3 Serial Number "
- ::= { radioModule3 18 }
- radioModule4PowerSwitch OBJECT-TYPE
- SYNTAX INTEGER {
- off(0),
- on(1)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "radioModule4 power switch"
- ::= { radioModule4 1 }
- radioModule4Port1InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port1 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm. "
- ::= { radioModule4 2 }
- radioModule4Port2InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port2 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule4 3 }
- radioModule4Port3InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port3 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule4 4 }
- radioModule4Port4InputPower OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "
- port4 Input power value
- unit:0.001dbm,
- rate:1000, for example: the value of 8000 actually means 8dbm.
- "
- ::= { radioModule4 5 }
- radioModule4Port1Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule4 6 }
- radioModule4Port2Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule4 7 }
- radioModule4Port3Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule4 8 }
- radioModule4Port4Attenuation OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Attenuation value
- unit:0.5db,
- rate:2. "
- ::= { radioModule4 9 }
- radioModule4Port1PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule4 10 }
- radioModule4Port2PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule4 11 }
- radioModule4Port3PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule4 12 }
- radioModule4Port4PowerDistribution OBJECT-TYPE
- SYNTAX INTEGER
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 input power distribution (%)
- unit:%,
- rate:1. "
- ::= { radioModule4 13 }
- radioModule4Port1Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port1 Label "
- ::= { radioModule4 14 }
- radioModule4Port2Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port2 Label "
- ::= { radioModule4 15 }
- radioModule4Port3Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port3 Label "
- ::= { radioModule4 16 }
- radioModule4Port4Label OBJECT-TYPE
- SYNTAX DisplayString (SIZE(0..20))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION "
- port4 Label "
- ::= { radioModule4 17 }
- radiomodule4SerialNumber OBJECT-TYPE
- SYNTAX DisplayString(SIZE(0..20))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "
- Module 4 Serial Number "
- ::= { radioModule4 18 }
- END