  1. www.BlueDriver.com Mode 6 Report
  2. Feb 07 2020 02:52:42-PM
  3. VIN: 1G6DV5EP3A0132339
  4. Mode 6 Information:
  5. • Oxygen Sensor Monitor Bank 1 - Sensor 1, Rich to lean sensor threshold voltage
  6. (constant), , Status: Complete and Pass MID: 01 TID: 01 MIN: 0,450 VAL: ✓
  7. 0,450 V MAX 0,450
  8. • Oxygen Sensor Monitor Bank 1 - Sensor 1, Lean to rich sensor threshold voltage
  9. (constant), , Status: Complete and Pass MID: 01 TID: 02 MIN: 0,450 VAL: ✓
  10. 0,450 V MAX 0,450
  11. • Oxygen Sensor Monitor Bank 1 - Sensor 1, Low sensor voltage for switch time
  12. calculation (constant), , Status: Complete and Pass MID: 01 TID: 03 MIN: ✓
  13. 0,300 VAL: 0,300 V MAX 0,300
  14. • Oxygen Sensor Monitor Bank 1 - Sensor 1, High sensor voltage for switch time
  15. calculation (constant), , Status: Complete and Pass MID: 01 TID: 04 MIN: ✓
  16. 0,601 VAL: 0,601 V MAX 0,601
  17. • Oxygen Sensor Monitor Bank 1 - Sensor 1, Rich to lean sensor switch time
  18. (calculated), , Status: Complete and Pass MID: 01 TID: 05 MIN: 0,000 VAL: ✓
  19. 0,036 s MAX 0,137
  20. • Oxygen Sensor Monitor Bank 1 - Sensor 1, Lean to rich sensor switch time
  21. (calculated), , Status: Complete and Pass MID: 01 TID: 06 MIN: 0,000 VAL: ✓
  22. 0,028 s MAX 0,144
  23. • Oxygen Sensor Monitor Bank 1 - Sensor 1, Manufacturer Defined Test ID range
  24. — This parameter is an identifier for the test performed within the On-Board
  25. Diagnostic Monitor., , Status: Complete and Pass MID: 01 TID: 80 MIN: 40 ✓
  26. VAL: 78 switches MAX 65535
  27. • Oxygen Sensor Monitor Bank 1 - Sensor 1, Manufacturer Defined Test ID range
  28. — This parameter is an identifier for the test performed within the On-Board
  29. Disclaimer:
  30. This information is provided without warranty and is subject to the Terms of Use posted at
  31. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  32. copyright.
  33. © Copyright 2018 Page 1 of 9www.BlueDriver.com Mode 6 Report
  34. Diagnostic Monitor., , Status: Complete and Pass MID: 01 TID: 81 MIN: 40 ✓
  35. VAL: 81 switches MAX 65535
  36. • Oxygen Sensor Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID range
  37. — This parameter is an identifier for the test performed within the On-Board
  38. Diagnostic Monitor., , Status: Complete and Pass MID: 02 TID: 8A MIN: 0 ✓
  39. VAL: 8 counts MAX 590
  40. • Oxygen Sensor Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID range
  41. — This parameter is an identifier for the test performed within the On-Board
  42. Diagnostic Monitor., , Status: Complete and Pass MID: 02 TID: 8B MIN: ✓
  43. 0,699940 VAL: 0,797232 V MAX 2,048005
  44. • Oxygen Sensor Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID range
  45. — This parameter is an identifier for the test performed within the On-Board
  46. Diagnostic Monitor., , Status: Complete and Pass MID: 02 TID: 8C MIN: ✓
  47. 0,000000 VAL: 0,074493 V MAX 0,099974
  48. • Oxygen Sensor Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID range
  49. — This parameter is an identifier for the test performed within the On-Board
  50. Diagnostic Monitor., , Status: Complete and Pass MID: 02 TID: 91 MIN: ✓
  51. 0,000000 VAL: 0,340156 V MAX 0,449883
  52. • Oxygen Sensor Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID range
  53. — This parameter is an identifier for the test performed within the On-Board
  54. Diagnostic Monitor., , Status: Complete and Pass MID: 02 TID: 92 MIN: ✓
  55. 0,349909 VAL: 0,421232 V MAX 2,048005
  56. • Oxygen Sensor Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID range
  57. — This parameter is an identifier for the test performed within the On-Board
  58. Diagnostic Monitor., , Status: Complete and Pass MID: 02 TID: 93 MIN: 0,00 ✓
  59. VAL: 0,52 MAX 8,29
  60. • Oxygen Sensor Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID range
  61. — This parameter is an identifier for the test performed within the On-Board
  62. Disclaimer:
  63. This information is provided without warranty and is subject to the Terms of Use posted at
  64. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  65. copyright.
  66. © Copyright 2018 Page 2 of 9www.BlueDriver.com Mode 6 Report
  67. Diagnostic Monitor., , Status: Complete and Pass MID: 02 TID: 94 MIN: 0,00 ✓
  68. VAL: 0,60 MAX 29,00
  69. • Oxygen Sensor Monitor Bank 2 - Sensor 1, Rich to lean sensor threshold voltage
  70. (constant), , Status: Complete and Pass MID: 05 TID: 01 MIN: 0,450 VAL: ✓
  71. 0,450 V MAX 0,450
  72. • Oxygen Sensor Monitor Bank 2 - Sensor 1, Lean to rich sensor threshold voltage
  73. (constant), , Status: Complete and Pass MID: 05 TID: 02 MIN: 0,450 VAL: ✓
  74. 0,450 V MAX 0,450
  75. • Oxygen Sensor Monitor Bank 2 - Sensor 1, Low sensor voltage for switch time
  76. calculation (constant), , Status: Complete and Pass MID: 05 TID: 03 MIN: ✓
  77. 0,300 VAL: 0,300 V MAX 0,300
  78. • Oxygen Sensor Monitor Bank 2 - Sensor 1, High sensor voltage for switch time
  79. calculation (constant), , Status: Complete and Pass MID: 05 TID: 04 MIN: ✓
  80. 0,601 VAL: 0,601 V MAX 0,601
  81. • Oxygen Sensor Monitor Bank 2 - Sensor 1, Rich to lean sensor switch time
  82. (calculated), , Status: Complete and Pass MID: 05 TID: 05 MIN: 0,000 VAL: ✓
  83. 0,033 s MAX 0,137
  84. • Oxygen Sensor Monitor Bank 2 - Sensor 1, Lean to rich sensor switch time
  85. (calculated), , Status: Complete and Pass MID: 05 TID: 06 MIN: 0,000 VAL: ✓
  86. 0,023 s MAX 0,144
  87. • Oxygen Sensor Monitor Bank 2 - Sensor 1, Manufacturer Defined Test ID range
  88. — This parameter is an identifier for the test performed within the On-Board
  89. Diagnostic Monitor., , Status: Complete and Pass MID: 05 TID: 80 MIN: 40 ✓
  90. VAL: 83 switches MAX 65535
  91. • Oxygen Sensor Monitor Bank 2 - Sensor 1, Manufacturer Defined Test ID range
  92. — This parameter is an identifier for the test performed within the On-Board
  93. Diagnostic Monitor., , Status: Complete and Pass MID: 05 TID: 81 MIN: 40 ✓
  94. VAL: 84 switches MAX 65535
  95. Disclaimer:
  96. This information is provided without warranty and is subject to the Terms of Use posted at
  97. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  98. copyright.
  99. © Copyright 2018 Page 3 of 9www.BlueDriver.com Mode 6 Report
  100. • Oxygen Sensor Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID range
  101. — This parameter is an identifier for the test performed within the On-Board
  102. Diagnostic Monitor., , Status: Complete and Pass MID: 06 TID: 8A MIN: 0 ✓
  103. VAL: 10 counts MAX 590
  104. • Oxygen Sensor Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID range
  105. — This parameter is an identifier for the test performed within the On-Board
  106. Diagnostic Monitor., , Status: Complete and Pass MID: 06 TID: 8B MIN: ✓
  107. 0,699940 VAL: 0,783089 V MAX 2,048005
  108. • Oxygen Sensor Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID range
  109. — This parameter is an identifier for the test performed within the On-Board
  110. Diagnostic Monitor., , Status: Complete and Pass MID: 06 TID: 8C MIN: ✓
  111. 0,000000 VAL: 0,094000 V MAX 0,099974
  112. • Oxygen Sensor Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID range
  113. — This parameter is an identifier for the test performed within the On-Board
  114. Diagnostic Monitor., , Status: Complete and Pass MID: 06 TID: 91 MIN: ✓
  115. 0,000000 VAL: 0,257738 V MAX 0,449883
  116. • Oxygen Sensor Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID range
  117. — This parameter is an identifier for the test performed within the On-Board
  118. Diagnostic Monitor., , Status: Complete and Pass MID: 06 TID: 92 MIN: ✓
  119. 0,349909 VAL: 0,635567 V MAX 2,048005
  120. • Oxygen Sensor Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID range
  121. — This parameter is an identifier for the test performed within the On-Board
  122. Diagnostic Monitor., , Status: Complete and Pass MID: 06 TID: 93 MIN: 0,00 ✓
  123. VAL: 0,55 MAX 8,29
  124. • Oxygen Sensor Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID range
  125. — This parameter is an identifier for the test performed within the On-Board
  126. Diagnostic Monitor., , Status: Complete and Pass MID: 06 TID: 94 MIN: 0,00 ✓
  127. VAL: 0,52 MAX 29,00
  128. Disclaimer:
  129. This information is provided without warranty and is subject to the Terms of Use posted at
  130. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  131. copyright.
  132. © Copyright 2018 Page 4 of 9www.BlueDriver.com Mode 6 Report
  133. • Catalyst Monitor Bank 1, Manufacturer Defined Test ID range — This parameter
  134. is an identifier for the test performed within the On-Board Diagnostic Monitor., , ✗
  135. Status: Test Fail MID: 21 TID: A0 MIN: 0,4997576 VAL: 0,3544729 MAX
  136. 0,9994847
  137. • Catalyst Monitor Bank 2, Manufacturer Defined Test ID range — This parameter
  138. is an identifier for the test performed within the On-Board Diagnostic Monitor., , ✗
  139. Status: Test Fail MID: 22 TID: A0 MIN: 0,4997576 VAL: 0,3907407 MAX
  140. 0,9994847
  141. • EVAP Monitor (0.090”), Manufacturer Defined Test ID range — This parameter is
  142. an identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  143. Status: Complete and Pass MID: 3A TID: C0 MIN: 0,000 VAL: 2,769 L MAX
  144. 18,000
  145. • EVAP Monitor (0.090”), Manufacturer Defined Test ID range — This parameter is
  146. an identifier for the test performed within the On-Board Diagnostic Monitor., , ―
  147. Status: Test not complete MID: 3A TID: C1 MIN: --h:--m:--s VAL: --h:--m:--s MAX
  148. --h:--m:--s
  149. • EVAP Monitor (0.020”), Manufacturer Defined Test ID range — This parameter is
  150. an identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  151. Status: Complete and Pass MID: 3C TID: C8 MIN: 0,0000000 VAL: 0,0000000
  152. MAX 0,5976490
  153. • EVAP Monitor (0.020”), Manufacturer Defined Test ID range — This parameter is
  154. an identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  155. Status: Complete and Pass MID: 3C TID: C9 MIN: 0,0000000 VAL: 0,0078124
  156. MAX 0,7265537
  157. • EVAP Monitor (0.020”), Manufacturer Defined Test ID range — This parameter is
  158. an identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  159. Status: Complete and Pass MID: 3C TID: CA MIN: 0 VAL: 0 counts MAX 1
  160. Disclaimer:
  161. This information is provided without warranty and is subject to the Terms of Use posted at
  162. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  163. copyright.
  164. © Copyright 2018 Page 5 of 9www.BlueDriver.com Mode 6 Report
  165. • EVAP Monitor (0.020”), Manufacturer Defined Test ID range — This parameter is
  166. an identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  167. Status: Complete and Pass MID: 3C TID: CB MIN: 0 VAL: 0 counts MAX 1
  168. • Purge Flow Monitor, Manufacturer Defined Test ID range — This parameter is an
  169. identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  170. Status: Complete and Pass MID: 3D TID: C4 MIN: 00h:06m:40s VAL:
  171. 00h:06m:40s MAX 18h:12m:15s
  172. • Purge Flow Monitor, Manufacturer Defined Test ID range — This parameter is an
  173. identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  174. Status: Complete and Pass MID: 3D TID: C5 MIN: -8000,00 VAL: 44,00 Pa MAX
  175. 2500,00
  176. • Purge Flow Monitor, Manufacturer Defined Test ID range — This parameter is an
  177. identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  178. Status: Complete and Pass MID: 3D TID: C6 MIN: 00h:00m:00s VAL:
  179. 00h:00m:08s MAX 00h:10m:00s
  180. • Purge Flow Monitor, Manufacturer Defined Test ID range — This parameter is an
  181. identifier for the test performed within the On-Board Diagnostic Monitor., , ✓
  182. Status: Complete and Pass MID: 3D TID: C7 MIN: 10,000 VAL: 10,014 L MAX
  183. 40,000
  184. • Oxygen Sensor Heater Monitor Bank 1 - Sensor 1, Manufacturer Defined Test ID
  185. range — This parameter is an identifier for the test performed within the On-Board
  186. Diagnostic Monitor., , Status: Complete and Pass MID: 41 TID: D2 MIN: 0 ✓
  187. VAL: 0 counts MAX 8
  188. • Oxygen Sensor Heater Monitor Bank 1 - Sensor 1, Manufacturer Defined Test ID
  189. range — This parameter is an identifier for the test performed within the On-Board
  190. Diagnostic Monitor., , Status: Complete and Pass MID: 41 TID: D3 MIN: ✓
  191. -4,211 VAL: -0,474 MAX 2,481
  192. • Oxygen Sensor Heater Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID
  193. range — This parameter is an identifier for the test performed within the On-Board
  194. Disclaimer:
  195. This information is provided without warranty and is subject to the Terms of Use posted at
  196. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  197. copyright.
  198. © Copyright 2018 Page 6 of 9www.BlueDriver.com Mode 6 Report
  199. Diagnostic Monitor., , Status: Complete and Pass MID: 42 TID: D2 MIN: 0 ✓
  200. VAL: 0 counts MAX 8
  201. • Oxygen Sensor Heater Monitor Bank 1 - Sensor 2, Manufacturer Defined Test ID
  202. range — This parameter is an identifier for the test performed within the On-Board
  203. Diagnostic Monitor., , Status: Complete and Pass MID: 42 TID: D3 MIN: ✓
  204. -4,199 VAL: -0,330 MAX 2,481
  205. • Oxygen Sensor Heater Monitor Bank 2 - Sensor 1, Manufacturer Defined Test ID
  206. range — This parameter is an identifier for the test performed within the On-Board
  207. Diagnostic Monitor., , Status: Complete and Pass MID: 45 TID: D2 MIN: 0 ✓
  208. VAL: 0 counts MAX 8
  209. • Oxygen Sensor Heater Monitor Bank 2 - Sensor 1, Manufacturer Defined Test ID
  210. range — This parameter is an identifier for the test performed within the On-Board
  211. Diagnostic Monitor., , Status: Complete and Pass MID: 45 TID: D3 MIN: ✓
  212. -4,211 VAL: -0,316 MAX 2,481
  213. • Oxygen Sensor Heater Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID
  214. range — This parameter is an identifier for the test performed within the On-Board
  215. Diagnostic Monitor., , Status: Complete and Pass MID: 46 TID: D2 MIN: 0 ✓
  216. VAL: 0 counts MAX 8
  217. • Oxygen Sensor Heater Monitor Bank 2 - Sensor 2, Manufacturer Defined Test ID
  218. range — This parameter is an identifier for the test performed within the On-Board
  219. Diagnostic Monitor., , Status: Complete and Pass MID: 46 TID: D3 MIN: ✓
  220. -4,199 VAL: -0,302 MAX 2,481
  221. • Mis-Fire Cylinder 1 Data, EWMA (Exponential Weighted Moving Average) misfire
  222. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  223. ✓, Status: Complete and Pass MID: A2 TID: 0B MIN: 0 VAL: 0 counts MAX
  224. 65535
  225. • Mis-Fire Cylinder 1 Data, Misfire counts for last/current driving cycles (calculated,
  226. rounded to an integer value), , Status: Complete and Pass MID: A2 TID: 0C ✓
  227. MIN: 0 VAL: 0 counts MAX 65535
  228. Disclaimer:
  229. This information is provided without warranty and is subject to the Terms of Use posted at
  230. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  231. copyright.
  232. © Copyright 2018 Page 7 of 9www.BlueDriver.com Mode 6 Report
  233. • Mis-Fire Cylinder 2 Data, EWMA (Exponential Weighted Moving Average) misfire
  234. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  235. ✓, Status: Complete and Pass MID: A3 TID: 0B MIN: 0 VAL: 0 counts MAX
  236. 65535
  237. • Mis-Fire Cylinder 2 Data, Misfire counts for last/current driving cycles (calculated,
  238. rounded to an integer value), , Status: Complete and Pass MID: A3 TID: 0C ✓
  239. MIN: 0 VAL: 0 counts MAX 65535
  240. • Mis-Fire Cylinder 3 Data, EWMA (Exponential Weighted Moving Average) misfire
  241. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  242. ✓, Status: Complete and Pass MID: A4 TID: 0B MIN: 0 VAL: 0 counts MAX
  243. 65535
  244. • Mis-Fire Cylinder 3 Data, Misfire counts for last/current driving cycles (calculated,
  245. rounded to an integer value), , Status: Complete and Pass MID: A4 TID: 0C ✓
  246. MIN: 0 VAL: 0 counts MAX 65535
  247. • Mis-Fire Cylinder 4 Data, EWMA (Exponential Weighted Moving Average) misfire
  248. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  249. ✓, Status: Complete and Pass MID: A5 TID: 0B MIN: 0 VAL: 0 counts MAX
  250. 65535
  251. • Mis-Fire Cylinder 4 Data, Misfire counts for last/current driving cycles (calculated,
  252. rounded to an integer value), , Status: Complete and Pass MID: A5 TID: 0C ✓
  253. MIN: 0 VAL: 0 counts MAX 65535
  254. • Mis-Fire Cylinder 5 Data, EWMA (Exponential Weighted Moving Average) misfire
  255. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  256. ✓, Status: Complete and Pass MID: A6 TID: 0B MIN: 0 VAL: 4 counts MAX
  257. 65535
  258. • Mis-Fire Cylinder 5 Data, Misfire counts for last/current driving cycles (calculated,
  259. rounded to an integer value), , Status: Complete and Pass MID: A6 TID: 0C ✓
  260. MIN: 0 VAL: 11 counts MAX 65535
  261. Disclaimer:
  262. This information is provided without warranty and is subject to the Terms of Use posted at
  263. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  264. copyright.
  265. © Copyright 2018 Page 8 of 9www.BlueDriver.com Mode 6 Report
  266. • Mis-Fire Cylinder 6 Data, EWMA (Exponential Weighted Moving Average) misfire
  267. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  268. ✓, Status: Complete and Pass MID: A7 TID: 0B MIN: 0 VAL: 0 counts MAX
  269. 65535
  270. • Mis-Fire Cylinder 6 Data, Misfire counts for last/current driving cycles (calculated,
  271. rounded to an integer value), , Status: Complete and Pass MID: A7 TID: 0C ✓
  272. MIN: 0 VAL: 0 counts MAX 65535
  273. • Mis-Fire Cylinder 7 Data, EWMA (Exponential Weighted Moving Average) misfire
  274. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  275. ✓, Status: Complete and Pass MID: A8 TID: 0B MIN: 0 VAL: 0 counts MAX
  276. 65535
  277. • Mis-Fire Cylinder 7 Data, Misfire counts for last/current driving cycles (calculated,
  278. rounded to an integer value), , Status: Complete and Pass MID: A8 TID: 0C ✓
  279. MIN: 0 VAL: 0 counts MAX 65535
  280. • Mis-Fire Cylinder 8 Data, EWMA (Exponential Weighted Moving Average) misfire
  281. counts for last ten (10) driving cycles (calculated, rounded to an integer value),
  282. ✓, Status: Complete and Pass MID: A9 TID: 0B MIN: 0 VAL: 0 counts MAX
  283. 65535
  284. • Mis-Fire Cylinder 8 Data, Misfire counts for last/current driving cycles (calculated,
  285. rounded to an integer value), , Status: Complete and Pass MID: A9 TID: 0C ✓
  286. MIN: 0 VAL: 0 counts MAX 65535
  287. Vehicle Protocol: CAN11_500
  288. Sensor F/W Version: v2.54
  289. App Version: 7.1.3-b224
  290. Disclaimer:
  291. This information is provided without warranty and is subject to the Terms of Use posted at
  292. www.lemurmonitors.com/eula.html. Reproduction of this information or any portion thereof constitutes infringement of
  293. copyright.
  294. © Copyright 2018 Page 9 of 9