- SAFETY CONCERNS
- • Visual indications suggest that there may be a small accumulation of mold near the chimney in the attic
- • Loose outlets were noted in one or more areas of the property.
- • Flexible dryer vent was being used.
- • Trip hazards were observed in one or more areas of the home.
- • One or more uncovered junction boxes were noted on the property.
- • There were missing smoke detectors and carbon monoxide detectors in the home.
- • There was no crash guard protecting the gas meter on the driveway side of the home.
- • There were missing handrails on the porch stairs
- • The transition at the rear door was deteriorating
- • An abandoned cable wire was noted protruding from the back side of the home
- ISSUES/DEFECTS
- • There was damage to the sheathing on the service cable.
- • There were double taps observed on the neutral bus bar in the main service panel.
- • Efflorescence was noted on the interior of the foundation.
- • A detached or broken tension spring, bar, or cable was noted on 4+ windows throughout the home
- • There was light cosmetic damage to the drywall in one bedroom.
- • Several three prong type receptacles in the home tested as having an open ground.
- • Several bathroom GFCI receptacles were observed to be connected to the lighting circuits.
- • A leak was noted at the plumbing waste line.
- • A leak was noted at the plumbing supply line.
- • There were no water shut off valves under one or more sinks.
- • One toilet was loose at the base.
- • One sink was loose at the base.
- • There was no visible GFCI for the jetted tub.
- • There was a defective low-emissivity coating at one or more windows.
- • A defective seal was observed at one or more windows.
- • Cracked glass was noted on one window and one door panel
- • Efflorescence was noted on the interior of the fire box and or chimney.
- • The disposal splash guard was deteriorated.
- • Surface wiring with a non-GFCI outlet was observed above the kitchen sink
- • Water stains were noted on 2 ceiling panels in the basement. The immediate area was found to be dry at time of inspection.
- • Damage was noted on the bathroom door in one or more areas.
- • Damaged and loose siding was noted on multiple areas of the home.
- • The general grade around the home appeared to be inadequate in the back patio.
- • Cracks and settlement were observed in the driveway.
- • Tree branches were making contact with and hanging over the roofing material.
- • Damaged shingles were noted in one or more areas of the roof.
- • The flashing around the chimney was separating.
- • Damaged siding was noted on multiple areas of the garage.
- • Loose shingles were noted in one or more areas of the roof.
- • Nail pops were noted in one or more areas of the roof.
- • Gaps around the line set for the air conditioner were noted where it enters the home.
- • The humidifier filter was dirty and should be replaced.
- • Although the heating system was operational, there was evidence of water in the furnace housing.
- • The neutral and ground busses were not properly isolated in this sub service panel.
- • Water stains were noted in the attic, in multiple areas. The immediate area was found to be dry at time of inspection.
- • The caulking on the exterior of the home was cracked or missing in one or more areas.
- • Peeling paint was noted in several areas of the home.
- • The garage overhead door panel(s) were dented in one or more places.
- • Open gaps in the siding were noted in one or more areas of the exterior of the garage.