Guest User

dmesg

a guest
Apr 12th, 2026
118
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 3.87 KB | None | 0 0
  1. [ 113.014188] vfio-pci 0000:01:00.0: resetting
  2. [ 113.014227] vfio-pci 0000:01:00.0: reset done
  3. [ 113.048529] vfio-pci 0000:01:00.0: resetting
  4. [ 113.048551] vfio-pci 0000:01:00.1: resetting
  5. [ 113.130041] virbr0: port 1(vnet0) entered learning state
  6. [ 114.154071] vfio-pci 0000:01:00.0: reset done
  7. [ 114.154088] vfio-pci 0000:01:00.1: reset done
  8. [ 115.178028] virbr0: port 1(vnet0) entered forwarding state
  9. [ 115.178033] virbr0: topology change detected, propagating
  10. [ 116.041822] DMAR: DRHD: handling fault status reg 3
  11. [ 116.041829] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x7cd7c000 [fault reason 0x0c] non-zero reserved fields in PTE
  12. [ 116.041832] DMAR: DRHD: handling fault status reg 3
  13. [ 116.041835] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x7cdb4000 [fault reason 0x0c] non-zero reserved fields in PTE
  14. [ 116.041837] DMAR: DRHD: handling fault status reg 3
  15. [ 116.041839] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x7cdc2000 [fault reason 0x0c] non-zero reserved fields in PTE
  16. [ 116.041843] DMAR: DRHD: handling fault status reg 3
  17. [ 124.606875] dmar_fault: 818 callbacks suppressed
  18. [ 124.606878] DMAR: DRHD: handling fault status reg 3
  19. [ 124.606881] DMAR: [DMA Read NO_PASID] Request device [01:00.1] fault addr 0x117ac4000 [fault reason 0x0c] non-zero reserved fields in PTE
  20. [ 128.292373] DMAR: DRHD: handling fault status reg 2
  21. [ 128.292379] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37ffec000 [fault reason 0x0c] non-zero reserved fields in PTE
  22. [ 128.415934] DMAR: DRHD: handling fault status reg 2
  23. [ 128.415942] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37ffc6000 [fault reason 0x0c] non-zero reserved fields in PTE
  24. [ 128.416014] DMAR: DRHD: handling fault status reg 2
  25. [ 188.406016] dmar_fault: 2 callbacks suppressed
  26. [ 188.406020] DMAR: DRHD: handling fault status reg 3
  27. [ 188.406023] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37fff1000 [fault reason 0x0c] non-zero reserved fields in PTE
  28. [ 188.406413] DMAR: DRHD: handling fault status reg 2
  29. [ 188.406416] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37ffec000 [fault reason 0x0c] non-zero reserved fields in PTE
  30. [ 193.882395] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  31. [ 193.882632] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  32. [ 193.882716] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  33. [ 193.883577] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  34. [ 193.883771] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  35. [ 193.883828] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  36. [ 193.886119] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  37. [ 193.888050] kvm: kvm [2062]: ignored rdmsr: 0x1a2 data 0x0
  38. [ 224.415040] DMAR: DRHD: handling fault status reg 2
  39. [ 224.415046] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37ffc5000 [fault reason 0x0c] non-zero reserved fields in PTE
  40. [ 224.415050] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37ffeb000 [fault reason 0x0c] non-zero reserved fields in PTE
  41. [ 284.405208] DMAR: DRHD: handling fault status reg 3
  42. [ 284.405212] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37fff1000 [fault reason 0x0c] non-zero reserved fields in PTE
  43. [ 284.405557] DMAR: DRHD: handling fault status reg 2
  44. [ 284.405559] DMAR: [DMA Read NO_PASID] Request device [01:00.0] fault addr 0x37ffeb000 [fault reason 0x0c] non-zero reserved fields in PTE
  45. [ 298.182795] virbr0: port 1(vnet0) entered disabled state
  46. [ 298.182915] vnet0 (unregistering): left allmulticast mode
  47. [ 298.182920] vnet0 (unregistering): left promiscuous mode
  48. [ 298.182922] virbr0: port 1(vnet0) entered disabled state
  49. [ 298.303669] vfio-pci 0000:01:00.0: resetting
  50. [ 298.303701] vfio-pci 0000:01:00.1: resetting
  51. [ 299.433667] vfio-pci 0000:01:00.0: reset done
  52. [ 299.433686] vfio-pci 0000:01:00.1: reset done