  1. ##### Bugs
  2. plc[connected]> read D100
  3. Error: (5, 'Input/output error')
  4. --The case where the connection was lost, and possibly re-enumerated with a different communications port
  5. The error is fine, but it should probably drop the connection too.
  6. this may happen when there are multiple communication ports active.
  7.  
  8.  
  9. ##### FIXED
  10. # fixed relaese force in MiSmSerial (reminant) MiSmTCP was fine
  11. # fixed utility folder
  12. # fixed tab completion ?? works on my machine
  13.  
  14. #####
  15. ## Not a bug, but could handle script error on conection fault better.
  16. Turn t0k outputs ON # what
  17. setting output Q0030 1
  18. Not connected. Run 'config' and then 'connect' first.
  19. setting output Q0031 1
  20. Not connected. Run 'config' and then 'connect' first.
  21. setting output Q0032 1
  22. Not connected. Run 'config' and then 'connect' first.
  23. setting output Q0033 1
  24. Not connected. Run 'config' and then 'connect' first.
  25. setting output Q0034 1
  26. Not connected. Run 'config' and then 'connect' first.
  27. setting output Q0035 1
  28. Not connected. Run 'config' and then 'connect' first.
  29. setting output Q0036 1
  30. Not connected. Run 'config' and then 'connect' first.
  31. setting output Q0037 1
  32. Not connected. Run 'config' and then 'connect' first.
  33. Error: [Errno 2] could not open port /dev/ttyACM0: [Errno 2] No such file or directory: '/dev/ttyACM0'
  34.  
  35. ## Not a bug, but should assign Y to Q and X to I
  36. This X,Y are Maintenance Protocol, but I,Q are standard naming conventions.
  37. plc[connected]> read_bit Y0030
  38. 1
  39. plc[connected]> output Q0030 0
  40. 0
  41. plc[connected]> read_bit Y0030 <--literal Maintenance Protocol command
  42. 0
  43. plc[connected]> read_bit Q0030 <-- Q should be bound to Y
  44. Error: bit dtype must be X/Y/M/R (or x/y/m/r)
  45. Q should be bound to Y, in ouput, it is but in read it is not.
  46. ## Check input for the same problem.
  47.  
Advertisement