Guest User

smartctl_hdd

a guest
Oct 27th, 2023
63
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 4.78 KB | None | 0 0
  1. smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.74-1-pve] (local build)
  2. Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Blue Mobile (SMR)
  6. Device Model: WDC WD20SPZX-00UA7T0
  7. Serial Number: WD-WXR2A8280JP9
  8. LU WWN Device Id: 5 0014ee 2156316d4
  9. Firmware Version: 01.01A01
  10. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Rotation Rate: 5400 rpm
  13. Form Factor: 2.5 inches
  14. TRIM Command: Available, deterministic
  15. Device is: In smartctl database [for details use: -P show]
  16. ATA Version is: ACS-3 T13/2161-D revision 5
  17. SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
  18. Local Time is: Fri Oct 27 09:23:43 2023 CEST
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART overall-health self-assessment test result: PASSED
  24.  
  25. General SMART Values:
  26. Offline data collection status: (0x00) Offline data collection activity
  27. was never started.
  28. Auto Offline Data Collection: Disabled.
  29. Self-test execution status: ( 0) The previous self-test routine completed
  30. without error or no self-test has ever
  31. been run.
  32. Total time to complete Offline
  33. data collection: (14580) seconds.
  34. Offline data collection
  35. capabilities: (0x71) SMART execute Offline immediate.
  36. No Auto Offline data collection support.
  37. Suspend Offline collection upon new
  38. command.
  39. No Offline surface scan supported.
  40. Self-test supported.
  41. Conveyance Self-test supported.
  42. Selective Self-test supported.
  43. SMART capabilities: (0x0003) Saves SMART data before entering
  44. power-saving mode.
  45. Supports SMART auto save timer.
  46. Error logging capability: (0x01) Error logging supported.
  47. General Purpose Logging supported.
  48. Short self-test routine
  49. recommended polling time: ( 2) minutes.
  50. Extended self-test routine
  51. recommended polling time: ( 270) minutes.
  52. Conveyance self-test routine
  53. recommended polling time: ( 4) minutes.
  54. SCT capabilities: (0x3035) SCT Status supported.
  55. SCT Feature Control supported.
  56. SCT Data Table supported.
  57.  
  58. SMART Attributes Data Structure revision number: 16
  59. Vendor Specific SMART Attributes with Thresholds:
  60. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  61. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
  62. 3 Spin_Up_Time 0x0027 222 222 021 Pre-fail Always - 1866
  63. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 9
  64. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  65. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  66. 9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 5938
  67. 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  68. 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  69. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 8
  70. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 2
  71. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 11
  72. 194 Temperature_Celsius 0x0022 094 085 000 Old_age Always - 53
  73. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  74. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
  75. 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
  76. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  77. 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
  78.  
  79. SMART Error Log Version: 1
  80. No Errors Logged
  81.  
  82. SMART Self-test log structure revision number 1
  83. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  84. # 1 Extended offline Completed without error 00% 5873 -
  85. # 2 Short offline Completed without error 00% 5245 -
  86.  
  87. SMART Selective self-test log data structure revision number 1
  88. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  89. 1 0 0 Not_testing
  90. 2 0 0 Not_testing
  91. 3 0 0 Not_testing
  92. 4 0 0 Not_testing
  93. 5 0 0 Not_testing
  94. Selective self-test flags (0x0):
  95. After scanning selected spans, do NOT read-scan remainder of disk.
  96. If Selective self-test is pending on power-up, resume after 0 minute delay.
  97.  