  1. ~]# smartctl -a /dev/sdc
  2. smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.8-200.fc38.x86_64] (local build)
  3. Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family: Seagate Exos X16
  7. Device Model: ST16000NM001G-2KK103
  8. Serial Number: ZL22XY1D
  9. LU WWN Device Id: 5 000c50 0c4382a1a
  10. Firmware Version: SN04
  11. User Capacity: 16,000,900,661,248 bytes [16.0 TB]
  12. Sector Sizes: 512 bytes logical, 4096 bytes physical
  13. Rotation Rate: 7200 rpm
  14. Form Factor: 3.5 inches
  15. Device is: In smartctl database 7.3/5417
  16. ATA Version is: ACS-4 (minor revision not indicated)
  17. SATA Version is: SATA 3.3, 6.0 Gb/s (current: 1.5 Gb/s)
  18. Local Time is: Fri Jul 7 18:31:57 2023 EDT
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART Status command failed: Connection timed out
  24. SMART overall-health self-assessment test result: PASSED
  25. Warning: This result is based on an Attribute check.
  26.  
  27. General SMART Values:
  28. Offline data collection status: (0x82) Offline data collection activity
  29. was completed without error.
  30. Auto Offline Data Collection: Enabled.
  31. Self-test execution status: ( 0) The previous self-test routine completed
  32. without error or no self-test has ever
  33. been run.
  34. Total time to complete Offline
  35. data collection: ( 567) seconds.
  36. Offline data collection
  37. capabilities: (0x7b) SMART execute Offline immediate.
  38. Auto Offline data collection on/off support.
  39. Suspend Offline collection upon new
  40. command.
  41. Offline surface scan supported.
  42. Self-test supported.
  43. Conveyance Self-test supported.
  44. Selective Self-test supported.
  45. SMART capabilities: (0x0003) Saves SMART data before entering
  46. power-saving mode.
  47. Supports SMART auto save timer.
  48. Error logging capability: (0x01) Error logging supported.
  49. General Purpose Logging supported.
  50. Short self-test routine
  51. recommended polling time: ( 1) minutes.
  52. Extended self-test routine
  53. recommended polling time: (1466) minutes.
  54. Conveyance self-test routine
  55. recommended polling time: ( 2) minutes.
  56. SCT capabilities: (0x70bd) SCT Status supported.
  57. SCT Error Recovery Control supported.
  58. SCT Feature Control supported.
  59. SCT Data Table supported.
  60.  
  61.  
  62. SMART Attributes Data Structure revision number: 10
  63. Vendor Specific SMART Attributes with Thresholds:
  64. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  65. 1 Raw_Read_Error_Rate 0x000f 071 064 044 Pre-fail Always - 134663752
  66. 3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0
  67. 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 2
  68. 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
  69. 7 Seek_Error_Rate 0x000f 062 060 045 Pre-fail Always - 1603459
  70. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 68
  71. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  72. 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 1
  73. 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0
  74. 187 Reported_Uncorrect 0x0032 091 091 000 Old_age Always - 9
  75. 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
  76. 190 Airflow_Temperature_Cel 0x0022 064 049 040 Old_age Always - 36 (Min/Max 26/44)
  77. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 0
  78. 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 12
  79. 194 Temperature_Celsius 0x0022 036 044 000 Old_age Always - 36 (0 26 0 0 0)
  80. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 32
  81. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 32
  82. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  83. 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0
  84. 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 20h+17m+03.781s
  85. 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 5509822400
  86. 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 236662
  87.  
  88. SMART Error Log Version: 1
  89. ATA Error Count: 9 (device log contains only the most recent five errors)
  90. CR = Command Register [HEX]
  91. FR = Features Register [HEX]
  92. SC = Sector Count Register [HEX]
  93. SN = Sector Number Register [HEX]
  94. CL = Cylinder Low Register [HEX]
  95. CH = Cylinder High Register [HEX]
  96. DH = Device/Head Register [HEX]
  97. DC = Device Command Register [HEX]
  98. ER = Error register [HEX]
  99. ST = Status register [HEX]
  100. Powered_Up_Time is measured from power on, and printed as
  101. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  102. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  103.  
  104. Error 9 occurred at disk power-on lifetime: 37 hours (1 days + 13 hours)
  105. When the command that caused the error occurred, the device was active or idle.
  106.  
  107. After command completion occurred, registers were:
  108. ER ST SC SN CL CH DH
  109. -- -- -- -- -- -- --
  110. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  111.  
  112. Commands leading to the command that caused the error were:
  113. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  114. -- -- -- -- -- -- -- -- ---------------- --------------------
  115. 25 00 08 ff ff ff ef 00 1d+13:42:13.753 READ DMA EXT
  116. 00 00 00 00 00 00 00 ff 1d+13:41:37.143 NOP [Abort queued commands]
  117. 25 00 08 ff ff ff ef 00 1d+13:41:34.492 READ DMA EXT
  118. 00 00 00 00 00 00 00 ff 1d+13:41:34.443 NOP [Abort queued commands]
  119. 25 00 08 ff ff ff ef 00 1d+13:41:31.767 READ DMA EXT
  120.  
  121. Error 8 occurred at disk power-on lifetime: 37 hours (1 days + 13 hours)
  122. When the command that caused the error occurred, the device was active or idle.
  123.  
  124. After command completion occurred, registers were:
  125. ER ST SC SN CL CH DH
  126. -- -- -- -- -- -- --
  127. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  128.  
  129. Commands leading to the command that caused the error were:
  130. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  131. -- -- -- -- -- -- -- -- ---------------- --------------------
  132. 25 00 08 ff ff ff ef 00 1d+13:41:34.492 READ DMA EXT
  133. 00 00 00 00 00 00 00 ff 1d+13:41:34.443 NOP [Abort queued commands]
  134. 25 00 08 ff ff ff ef 00 1d+13:41:31.767 READ DMA EXT
  135. 00 00 00 00 00 00 00 ff 1d+13:40:55.110 NOP [Abort queued commands]
  136. 25 00 08 ff ff ff ef 00 1d+13:40:52.435 READ DMA EXT
  137.  
  138. Error 7 occurred at disk power-on lifetime: 37 hours (1 days + 13 hours)
  139. When the command that caused the error occurred, the device was active or idle.
  140.  
  141. After command completion occurred, registers were:
  142. ER ST SC SN CL CH DH
  143. -- -- -- -- -- -- --
  144. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  145.  
  146. Commands leading to the command that caused the error were:
  147. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  148. -- -- -- -- -- -- -- -- ---------------- --------------------
  149. 25 00 08 ff ff ff ef 00 1d+13:41:31.767 READ DMA EXT
  150. 00 00 00 00 00 00 00 ff 1d+13:40:55.110 NOP [Abort queued commands]
  151. 25 00 08 ff ff ff ef 00 1d+13:40:52.435 READ DMA EXT
  152. 00 00 00 00 00 00 00 ff 1d+13:40:52.386 NOP [Abort queued commands]
  153. 25 00 08 ff ff ff ef 00 1d+13:40:49.781 READ DMA EXT
  154.  
  155. Error 6 occurred at disk power-on lifetime: 37 hours (1 days + 13 hours)
  156. When the command that caused the error occurred, the device was active or idle.
  157.  
  158. After command completion occurred, registers were:
  159. ER ST SC SN CL CH DH
  160. -- -- -- -- -- -- --
  161. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  162.  
  163. Commands leading to the command that caused the error were:
  164. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  165. -- -- -- -- -- -- -- -- ---------------- --------------------
  166. 25 00 08 ff ff ff ef 00 1d+13:40:52.435 READ DMA EXT
  167. 00 00 00 00 00 00 00 ff 1d+13:40:52.386 NOP [Abort queued commands]
  168. 25 00 08 ff ff ff ef 00 1d+13:40:49.781 READ DMA EXT
  169. 00 00 00 00 00 00 00 ff 1d+13:40:13.186 NOP [Abort queued commands]
  170. 25 00 08 ff ff ff ef 00 1d+13:40:10.519 READ DMA EXT
  171.  
  172. Error 5 occurred at disk power-on lifetime: 37 hours (1 days + 13 hours)
  173. When the command that caused the error occurred, the device was active or idle.
  174.  
  175. After command completion occurred, registers were:
  176. ER ST SC SN CL CH DH
  177. -- -- -- -- -- -- --
  178. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  179.  
  180. Commands leading to the command that caused the error were:
  181. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  182. -- -- -- -- -- -- -- -- ---------------- --------------------
  183. 25 00 08 ff ff ff ef 00 1d+13:40:49.781 READ DMA EXT
  184. 00 00 00 00 00 00 00 ff 1d+13:40:13.186 NOP [Abort queued commands]
  185. 25 00 08 ff ff ff ef 00 1d+13:40:10.519 READ DMA EXT
  186. 00 00 00 00 00 00 00 ff 1d+13:40:10.470 NOP [Abort queued commands]
  187. 25 00 08 ff ff ff ef 00 1d+13:40:07.795 READ DMA EXT
  188.  
  189. SMART Self-test log structure revision number 1
  190. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  191.  
  192. SMART Selective self-test log data structure revision number 1
  193. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  194. 1 0 0 Not_testing
  195. 2 0 0 Not_testing
  196. 3 0 0 Not_testing
  197. 4 0 0 Not_testing
  198. 5 0 0 Not_testing
  199. Selective self-test flags (0x0):
  200. After scanning selected spans, do NOT read-scan remainder of disk.
  201. If Selective self-test is pending on power-up, resume after 0 minute delay.
  202.  
  203. ~]# smartctl -l selftest /dev/sdc
  204. smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.8-200.fc38.x86_64] (local build)
  205. Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
  206.  
  207. === START OF READ SMART DATA SECTION ===
  208. SMART Self-test log structure revision number 1
  209. No self-tests have been logged. [To run self-tests, use: smartctl -t]