- smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.2-STABLE amd64] (local build)
- Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red
- Device Model: WDC WD40EFRX-68WT0N0
- Serial Number: WD-WCC4E0JS2X79
- LU WWN Device Id: 5 0014ee 20d474759
- Firmware Version: 82.00A82
- User Capacity: 4,000,787,030,016 bytes [4.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Sat Jan 11 00:44:18 2020 AEDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- Read SMART Thresholds failed: Input/output error
- === START OF READ SMART DATA SECTION ===
- SMART Status command failed: Input/output error
- SMART overall-health self-assessment test result: UNKNOWN!
- SMART Status, Attributes and Thresholds cannot be read.
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (52320) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 523) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x703d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 153 153 --- Pre-fail Always - 308664
- 3 Spin_Up_Time 0x0027 194 182 --- Pre-fail Always - 7283
- 4 Start_Stop_Count 0x0032 100 100 --- Old_age Always - 69
- 5 Reallocated_Sector_Ct 0x0033 199 199 --- Pre-fail Always - 30
- 7 Seek_Error_Rate 0x002e 200 200 --- Old_age Always - 0
- 9 Power_On_Hours 0x0032 069 069 --- Old_age Always - 23104
- 10 Spin_Retry_Count 0x0032 100 253 --- Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 --- Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 --- Old_age Always - 69
- 192 Power-Off_Retract_Count 0x0032 200 200 --- Old_age Always - 65
- 193 Load_Cycle_Count 0x0032 200 200 --- Old_age Always - 744
- 194 Temperature_Celsius 0x0022 121 111 --- Old_age Always - 31
- 196 Reallocated_Event_Count 0x0032 170 170 --- Old_age Always - 30
- 197 Current_Pending_Sector 0x0032 200 200 --- Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 253 --- Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 --- Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 100 253 --- Old_age Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 63688 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 63688 occurred at disk power-on lifetime: 23104 hours (962 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 10 98 02 40 40 Error: UNC 16 sectors at LBA = 0x00400298 = 4194968
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 10 90 02 40 40 08 11:04:39.084 READ DMA
- b0 d1 01 01 4f c2 40 08 11:04:39.076 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
- c8 00 10 90 02 40 40 08 11:04:35.469 READ DMA
- b0 d0 01 00 4f c2 40 08 11:04:35.466 SMART READ DATA
- b0 d0 01 00 4f c2 40 08 11:04:35.380 SMART READ DATA
- Error 63687 occurred at disk power-on lifetime: 23104 hours (962 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 10 98 02 40 40 Error: UNC 16 sectors at LBA = 0x00400298 = 4194968
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 10 90 02 40 40 08 11:04:35.469 READ DMA
- b0 d0 01 00 4f c2 40 08 11:04:35.466 SMART READ DATA
- b0 d0 01 00 4f c2 40 08 11:04:35.380 SMART READ DATA
- c8 00 10 90 02 40 40 08 11:04:31.438 READ DMA
- ec 00 01 00 00 00 40 08 11:04:31.438 IDENTIFY DEVICE
- Error 63686 occurred at disk power-on lifetime: 23104 hours (962 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 10 98 02 40 40 Error: UNC 16 sectors at LBA = 0x00400298 = 4194968
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 10 90 02 40 40 08 11:04:31.438 READ DMA
- ec 00 01 00 00 00 40 08 11:04:31.438 IDENTIFY DEVICE
- ec 00 01 00 00 00 40 08 11:04:31.429 IDENTIFY DEVICE
- c8 00 10 90 02 40 40 08 11:04:28.010 READ DMA
- e5 00 00 00 00 00 40 08 11:04:28.010 CHECK POWER MODE
- Error 63685 occurred at disk power-on lifetime: 23104 hours (962 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 10 98 02 40 40 Error: UNC 16 sectors at LBA = 0x00400298 = 4194968
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 10 90 02 40 40 08 11:04:28.010 READ DMA
- e5 00 00 00 00 00 40 08 11:04:28.010 CHECK POWER MODE
- c8 00 10 90 02 40 40 08 11:04:24.379 READ DMA
- c8 00 e0 a0 00 40 40 08 11:04:21.115 READ DMA
- c8 00 e0 a0 00 40 40 08 11:04:17.830 READ DMA
- Error 63684 occurred at disk power-on lifetime: 23104 hours (962 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 10 98 02 40 40 Error: UNC 16 sectors at LBA = 0x00400298 = 4194968
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 10 90 02 40 40 08 11:04:24.379 READ DMA
- c8 00 e0 a0 00 40 40 08 11:04:21.115 READ DMA
- c8 00 e0 a0 00 40 40 08 11:04:17.830 READ DMA
- c8 00 e0 a0 00 40 40 08 11:04:14.566 READ DMA
- c8 00 e0 a0 00 40 40 08 11:04:11.281 READ DMA
- Read SMART Self-test Log failed: Input/output error
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.