- ~ > pfexec fmadm faulty
- --------------- ------------------------------------ -------------- ---------
- TIME EVENT-ID MSG-ID SEVERITY
- --------------- ------------------------------------ -------------- ---------
- de set. 28 00:10:23 ebd6e9b9-4fbd-4c26-b419-1fb7987642c8 PCIEX-8000-0A Critical
- Host : sula
- Platform : HP-EliteDesk-800-G6-Small-Form-Factor-PC Chassis_id : CZC121B3KZ
- Product_sn :
- Fault class : fault.io.pciex.device-interr
- Affects : dev:////pci@0,0/pci8086,6c0@1b/pci144d,a801@0
- faulted and taken out of service
- FRU : "Slot7 / M2 SSD2" (hc://:product-id=HP-EliteDesk-800-G6-Small-Form-Factor-PC:server-id=sula:chassis-id=CZC121B3KZ/motherboard=0/hostbridge=0/pciexrc=0/pciexbus=1)
- faulty
- Description : A problem was detected for a PCIEX device.
- Refer to http://illumos.org/msg/PCIEX-8000-0A for more
- information.
- Response : One or more device instances may be disabled
- Impact : Loss of services provided by the device instances associated with
- this fault
- Action : Schedule a repair procedure to replace the affected device. Use
- fmadm faulty to identify the device or contact your illumos
- distribution team for support.