icez

Untitled

Feb 4th, 2021
131
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 9.31 KB | None | 0 0
  1.  
  2. === START OF READ SMART DATA SECTION ===
  3. SMART overall-health self-assessment test result: PASSED
  4.  
  5. General SMART Values:
  6. Offline data collection status: (0x82) Offline data collection activity
  7. was completed without error.
  8. Auto Offline Data Collection: Enabled.
  9. Self-test execution status: ( 0) The previous self-test routine completed
  10. without error or no self-test has ever
  11. been run.
  12. Total time to complete Offline
  13. data collection: ( 87) seconds.
  14. Offline data collection
  15. capabilities: (0x5b) SMART execute Offline immediate.
  16. Auto Offline data collection on/off support.
  17. Suspend Offline collection upon new
  18. command.
  19. Offline surface scan supported.
  20. Self-test supported.
  21. No Conveyance Self-test supported.
  22. Selective Self-test supported.
  23. SMART capabilities: (0x0003) Saves SMART data before entering
  24. power-saving mode.
  25. Supports SMART auto save timer.
  26. Error logging capability: (0x01) Error logging supported.
  27. General Purpose Logging supported.
  28. Short self-test routine
  29. recommended polling time: ( 2) minutes.
  30. Extended self-test routine
  31. recommended polling time: (1310) minutes.
  32. SCT capabilities: (0x003d) SCT Status supported.
  33. SCT Error Recovery Control supported.
  34. SCT Feature Control supported.
  35. SCT Data Table supported.
  36.  
  37. SMART Attributes Data Structure revision number: 16
  38. Vendor Specific SMART Attributes with Thresholds:
  39. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  40. 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
  41. 2 Throughput_Performance 0x0005 130 130 054 Pre-fail Offline - 100
  42. 3 Spin_Up_Time 0x0007 176 176 024 Pre-fail Always - 387 (Average 359)
  43. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 11
  44. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
  45. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  46. 8 Seek_Time_Performance 0x0005 140 140 020 Pre-fail Offline - 15
  47. 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 138
  48. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  49. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 11
  50. 22 Helium_Level 0x0023 100 100 025 Pre-fail Always - 100
  51. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 20
  52. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 20
  53. 194 Temperature_Celsius 0x0002 222 222 000 Old_age Always - 27 (Min/Max 25/54)
  54. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
  55. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
  56. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  57. 199 UDMA_CRC_Error_Count 0x000a 199 199 000 Old_age Always - 1773
  58.  
  59. SMART Error Log Version: 1
  60. ATA Error Count: 1773 (device log contains only the most recent five errors)
  61. CR = Command Register [HEX]
  62. FR = Features Register [HEX]
  63. SC = Sector Count Register [HEX]
  64. SN = Sector Number Register [HEX]
  65. CL = Cylinder Low Register [HEX]
  66. CH = Cylinder High Register [HEX]
  67. DH = Device/Head Register [HEX]
  68. DC = Device Command Register [HEX]
  69. ER = Error register [HEX]
  70. ST = Status register [HEX]
  71. Powered_Up_Time is measured from power on, and printed as
  72. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  73. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  74.  
  75. Error 1773 occurred at disk power-on lifetime: 42 hours (1 days + 18 hours)
  76. When the command that caused the error occurred, the device was active or idle.
  77.  
  78. After command completion occurred, registers were:
  79. ER ST SC SN CL CH DH
  80. -- -- -- -- -- -- --
  81. 84 41 00 00 00 00 00 Error: ICRC, ABRT at LBA = 0x00000000 = 0
  82.  
  83. Commands leading to the command that caused the error were:
  84. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  85. -- -- -- -- -- -- -- -- ---------------- --------------------
  86. 60 00 00 00 c8 00 40 00 21:04:05.666 READ FPDMA QUEUED
  87. 2f 00 01 10 00 00 00 00 21:04:05.666 READ LOG EXT
  88. 60 00 08 00 cc 00 40 00 21:04:05.666 READ FPDMA QUEUED
  89. 60 00 00 00 c4 00 40 00 21:04:05.663 READ FPDMA QUEUED
  90. 60 00 00 00 bc 00 40 00 21:04:05.659 READ FPDMA QUEUED
  91.  
  92. Error 1772 occurred at disk power-on lifetime: 42 hours (1 days + 18 hours)
  93. When the command that caused the error occurred, the device was active or idle.
  94.  
  95. After command completion occurred, registers were:
  96. ER ST SC SN CL CH DH
  97. -- -- -- -- -- -- --
  98. 84 41 00 00 00 00 00 Error: ICRC, ABRT at LBA = 0x00000000 = 0
  99.  
  100. Commands leading to the command that caused the error were:
  101. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  102. -- -- -- -- -- -- -- -- ---------------- --------------------
  103. 60 00 00 00 0c 00 40 00 21:04:05.563 READ FPDMA QUEUED
  104. 2f 00 01 10 00 00 00 00 21:04:05.563 READ LOG EXT
  105. 60 00 00 00 08 00 40 00 21:04:05.560 READ FPDMA QUEUED
  106. 60 00 00 00 04 00 40 00 21:04:05.558 READ FPDMA QUEUED
  107. 60 00 00 00 fc ff 40 00 21:04:05.554 READ FPDMA QUEUED
  108.  
  109. Error 1771 occurred at disk power-on lifetime: 42 hours (1 days + 18 hours)
  110. When the command that caused the error occurred, the device was active or idle.
  111.  
  112. After command completion occurred, registers were:
  113. ER ST SC SN CL CH DH
  114. -- -- -- -- -- -- --
  115. 84 41 00 00 00 00 00 Error: ICRC, ABRT at LBA = 0x00000000 = 0
  116.  
  117. Commands leading to the command that caused the error were:
  118. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  119. -- -- -- -- -- -- -- -- ---------------- --------------------
  120. 60 00 00 00 74 ff 40 00 21:04:05.469 READ FPDMA QUEUED
  121. 60 00 08 00 6c ff 40 00 21:04:05.463 READ FPDMA QUEUED
  122. 60 00 00 00 68 ff 40 00 21:04:05.462 READ FPDMA QUEUED
  123. 60 00 00 00 64 ff 40 00 21:04:05.460 READ FPDMA QUEUED
  124. 60 00 00 00 5c ff 40 00 21:04:05.458 READ FPDMA QUEUED
  125.  
  126. Error 1770 occurred at disk power-on lifetime: 42 hours (1 days + 18 hours)
  127. When the command that caused the error occurred, the device was active or idle.
  128.  
  129. After command completion occurred, registers were:
  130. ER ST SC SN CL CH DH
  131. -- -- -- -- -- -- --
  132. 84 41 00 00 00 00 00 Error: ICRC, ABRT at LBA = 0x00000000 = 0
  133.  
  134. Commands leading to the command that caused the error were:
  135. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  136. -- -- -- -- -- -- -- -- ---------------- --------------------
  137. 60 00 00 00 54 ff 40 00 21:04:05.437 READ FPDMA QUEUED
  138. 60 00 00 00 4c ff 40 00 21:04:05.431 READ FPDMA QUEUED
  139. 60 00 00 00 48 ff 40 00 21:04:05.429 READ FPDMA QUEUED
  140. 60 00 00 00 44 ff 40 00 21:04:05.427 READ FPDMA QUEUED
  141. 60 00 00 00 3c ff 40 00 21:04:05.423 READ FPDMA QUEUED
  142.  
  143. Error 1769 occurred at disk power-on lifetime: 42 hours (1 days + 18 hours)
  144. When the command that caused the error occurred, the device was active or idle.
  145.  
  146. After command completion occurred, registers were:
  147. ER ST SC SN CL CH DH
  148. -- -- -- -- -- -- --
  149. 84 41 00 00 00 00 00 Error: ICRC, ABRT at LBA = 0x00000000 = 0
  150.  
  151. Commands leading to the command that caused the error were:
  152. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  153. -- -- -- -- -- -- -- -- ---------------- --------------------
  154. 60 00 00 00 ec fe 40 00 21:04:05.375 READ FPDMA QUEUED
  155. 60 00 00 00 e8 fe 40 00 21:04:05.372 READ FPDMA QUEUED
  156. 60 00 00 00 e4 fe 40 00 21:04:05.370 READ FPDMA QUEUED
  157. 60 00 00 00 dc fe 40 00 21:04:05.366 READ FPDMA QUEUED
  158. 60 00 00 00 d8 fe 40 00 21:04:05.364 READ FPDMA QUEUED
  159.  
  160. SMART Self-test log structure revision number 1
  161. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  162. # 1 Short offline Completed without error 00% 0 -
  163.  
  164. SMART Selective self-test log data structure revision number 1
  165. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  166. 1 0 0 Not_testing
  167. 2 0 0 Not_testing
  168. 3 0 0 Not_testing
  169. 4 0 0 Not_testing
  170. 5 0 0 Not_testing
  171. Selective self-test flags (0x0):
  172. After scanning selected spans, do NOT read-scan remainder of disk.
  173. If Selective self-test is pending on power-up, resume after 0 minute delay.
  174.  
  175.  
Advertisement