- icinga2 object list --type="CheckCommand" --name="check_common_ups"
- Object 'check_common_ups' of type 'CheckCommand':
- % declared in '/usr/share/icinga2/include/plugins-contrib.d/common_ups.conf', lines 9:1-9:38
- * __name = "check_common_ups"
- * arguments
- % = modified in '/usr/share/icinga2/include/plugins-contrib.d/common_ups.conf', lines 14:5-120:5
- * -B
- * description = "Set this to not check battery replace status"
- * required = false
- * set_if = "$ups_noreplaceck$"
- * -C
- * description = "SNMP community string. Default: public"
- * required = false
- * value = "$ups_community$"
- * -H
- * description = "Address of the UPS"
- * required = true
- * value = "$ups_address$"
- * -I
- * description = "Integer value of desired high input voltage WARNING threshold. Default: 133"
- * required = false
- * value = "$ups_inhigh$"
- * -L
- * description = "Integer value of desired load CRITICAL threshold. Default: 80"
- * required = false
- * value = "$ups_critload$"
- * -R
- * description = "Integer value of desired run time CRITICAL threshold. Default: 8 Minimum: 1"
- * required = false
- * value = "$ups_critrun$"
- * -T
- * description = "Integer value of desired temperature CRITICAL threshold. Default: 122f/50c"
- * required = false
- * value = "$ups_crittemp$"
- * -W
- * description = "Integer value number of days since last diagnostic for CRITICAL. Default: 20"
- * required = false
- * value = "$ups_diagcrit$"
- * -X
- * description = "Disables calibration check and calibration data"
- * set_if = "$ups_nocalibck$"
- * -Y
- * description = "Integer value number of days since last calibration for CRITICAL. Default: 400"
- * required = false
- * value = "$ups_calibcrit$"
- * -Z
- * description = "Disables calibration data"
- * set_if = "$ups_nocalibdata$"
- * -b
- * description = "Set this if you wish any on battery status to be shown as critical instead of warning"
- * required = false
- * set_if = "$ups_onbattiscrit$"
- * -d
- * description = "Selects celsius or fahrenheit. One of: C,c,F,f. Default: f"
- * required = false
- * value = "$ups_degrees$"
- * -i
- * description = "Integer value of desired low input voltage WARNING threshold. Default: 106"
- * required = false
- * value = "$ups_inlow$"
- * -l
- * description = "Integer value of desired load WARNING threshold. Default: 70"
- * required = false
- * value = "$ups_warnload$"
- * -r
- * description = "Integer value of desired run time WARNING threshold. Default: 10 Minimum: 2"
- * required = false
- * value = "$ups_warnrun$"
- * -t
- * description = "Integer value of desired temperature WARNING threshold. Default: 113f/45c"
- * required = false
- * value = "$ups_warntemp$"
- * -v
- * description = "Set this if you wish CRITICAL instead of default WARNING for input voltage low or high results."
- * set_if = "$ups_voltcrit$"
- * -w
- * description = "Integer value number of days since last diagnostic for WARNING. Default: 15"
- * required = false
- * value = "$ups_diagwarn$"
- * -x
- * description = "Disables diagnostic check and diagnostic data"
- * set_if = "$ups_nodiagck$"
- * -y
- * description = "Integer value number of days since last calibration for WARNING. Default: 365"
- * required = false
- * value = "$ups_calibwarn$"
- * -z
- * description = "Disables diagnostic data"
- * set_if = "$ups_nodiagdata$"
- * command = [ "/usr/lib/nagios/plugins/check_common_ups" ]
- % = modified in '/usr/share/icinga2/include/plugins-contrib.d/common_ups.conf', lines 12:5-12:56
- * env = null
- * execute
- % = modified in 'methods-itl.conf', lines 38:3-38:33
- % = modified in 'methods-itl.conf', lines 38:3-38:33
- * arguments = [ "checkable", "cr", "resolvedMacros", "useResolvedMacros" ]
- * deprecated = false
- * name = "Internal#PluginCheck"
- * side_effect_free = false
- * type = "Function"
- * name = "check_common_ups"
- * package = "_etc"
- * source_location
- * first_column = 1
- * first_line = 9
- * last_column = 38
- * last_line = 9
- * path = "/usr/share/icinga2/include/plugins-contrib.d/common_ups.conf"
- * templates = [ "check_common_ups", "plugin-check-command", "plugin-check-command" ]
- % = modified in '/usr/share/icinga2/include/plugins-contrib.d/common_ups.conf', lines 9:1-9:38
- % = modified in 'methods-itl.conf', lines 37:2-37:69
- % = modified in 'methods-itl.conf', lines 37:2-37:69
- * timeout = 60
- * type = "CheckCommand"
- * vars = null
- * zone = ""