- smartctl -a -d megaraid,5 /dev/bus/0
- smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-74-generic] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Re
- Device Model: WDC WD3000FYYZ-01UL1B2
- Serial Number: WD-
- LU WWN Device Id: 5 0014ee 605bd53d8
- Firmware Version: 01.01K03
- User Capacity: 3,000,592,982,016 bytes [3.00 TB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: 7200 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Sun Jan 26 14:48:42 2020 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART Status not supported: ATA return descriptor not supported by controller firmware
- SMART overall-health self-assessment test result: PASSED
- Warning: This result is based on an Attribute check.
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (34320) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 372) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x70bd) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 167 152 021 Pre-fail Always - 10625
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 29
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 053 053 000 Old_age Always - 34575
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 28
- 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 25
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 3
- 194 Temperature_Celsius 0x0022 117 106 000 Old_age Always - 35
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 34522 -
- # 2 Extended offline Completed without error 00% 34507 -
- # 3 Short offline Completed without error 00% 34500 -
- # 4 Extended offline Completed without error 00% 34208 -
- # 5 Extended offline Completed without error 00% 34189 -
- # 6 Extended offline Completed without error 00% 34072 -
- # 7 Extended offline Completed without error 00% 34053 -
- # 8 Extended offline Completed without error 00% 32183 -
- # 9 Extended offline Completed without error 00% 32163 -
- #10 Short offline Completed without error 00% 31956 -
- #11 Extended offline Completed without error 00% 29611 -
- #12 Extended offline Completed without error 00% 29592 -
- #13 Extended offline Completed without error 00% 28869 -
- #14 Extended offline Completed without error 00% 28849 -
- #15 Extended offline Completed without error 00% 24340 -
- #16 Extended offline Completed without error 00% 24321 -
- #17 Extended offline Completed without error 00% 23526 -
- #18 Extended offline Completed without error 00% 23507 -
- #19 Extended offline Completed without error 00% 13082 -
- #20 Extended offline Completed without error 00% 13062 -
- #21 Extended offline Completed without error 00% 436 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
Add Comment