Caldin-Maldin

vestibule d1

Mar 3rd, 2023
36
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 1.51 KB | None | 0 0
  1. binary_sensor:
  2. - platform: gpio
  3. pin:
  4. number: D2
  5. # mode: INPUT_PULLUP
  6. mode: INPUT
  7. inverted: true
  8. name: "Street door"
  9. device_class: door
  10. - platform: gpio
  11. pin:
  12. number: D7
  13. # mode: INPUT_PULLDOWN
  14. name: "Motion sensor vestibule"
  15. device_class: motion
  16. filters:
  17. - delayed_on: 100ms
  18. - delayed_off: 60000ms
  19. - platform: gpio
  20. pin:
  21. number: RX
  22. mode: INPUT_PULLUP
  23. # mode: INPUT
  24. inverted: true
  25. name: "Street call"
  26. device_class: plug
  27.  
  28. switch:
  29. - platform: gpio
  30. pin: D8
  31. id: relay1
  32. name: "Street door remote"
  33. icon: "mdi:gate"
  34. on_turn_on:
  35. - delay: 500ms
  36. - switch.turn_off: relay1
  37. restore_mode:
  38. ALWAYS_OFF
  39.  
  40.  
  41. - platform: gpio
  42. pin: D1
  43. id: relay2
  44. name: "Relay"
  45.  
  46. - platform: uart
  47. name: Pzem_Energy_Reset_UART
  48. data: [0x01, 0x42, 0x80, 0x11]
  49. uart_id: pzem_uart
  50.  
  51. uart:
  52. rx_pin: D5
  53. tx_pin: D6
  54. baud_rate: 9600
  55. stop_bits: 1
  56. id: pzem_uart
  57.  
  58. sensor:
  59. - platform: wifi_signal
  60. name: "Street door WiFi Signal"
  61. - platform: pzemac
  62. current:
  63. name: "PZEM-004T V3 Current"
  64. voltage:
  65. name: "PZEM-004T V3 Voltage"
  66. energy:
  67. name: "PZEM-004T V3 Energy"
  68. power:
  69. name: "PZEM-004T V3 Power"
  70. frequency:
  71. name: "PZEM-004T V3 Frequency"
  72. power_factor:
  73. name: "PZEM-004T V3 Power Factor"
  74. update_interval: 30s
  75. - platform: uptime
  76. name: Uptime Sensor
Advertisement