  1. smartctl --all /dev/sde
  2. smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
  3. Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family: SandForce Driven SSDs
  7. Device Model: Corsair Force LS SSD
  8. Serial Number: 173079400001226601F3
  9. LU WWN Device Id: 5 000000 000000000
  10. Firmware Version: SBFM01.0
  11. User Capacity: 120,034,123,776 bytes [120 GB]
  12. Sector Size: 512 bytes logical/physical
  13. Rotation Rate: Solid State Device
  14. Form Factor: 2.5 inches
  15. Device is: In smartctl database [for details use: -P show]
  16. ATA Version is: Unknown(0x0ff8) (minor revision not indicated)
  17. SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
  18. Local Time is: Mon Nov 27 12:09:57 2017 CET
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART overall-health self-assessment test result: PASSED
  24.  
  25. General SMART Values:
  26. Offline data collection status: (0x00) Offline data collection activity
  27. was never started.
  28. Auto Offline Data Collection: Disabled.
  29. Self-test execution status: ( 0) The previous self-test routine completed
  30. without error or no self-test has ever
  31. been run.
  32. Total time to complete Offline
  33. data collection: (65535) seconds.
  34. Offline data collection
  35. capabilities: (0x79) SMART execute Offline immediate.
  36. No Auto Offline data collection support.
  37. Suspend Offline collection upon new
  38. command.
  39. Offline surface scan supported.
  40. Self-test supported.
  41. Conveyance Self-test supported.
  42. Selective Self-test supported.
  43. SMART capabilities: (0x0003) Saves SMART data before entering
  44. power-saving mode.
  45. Supports SMART auto save timer.
  46. Error logging capability: (0x01) Error logging supported.
  47. General Purpose Logging supported.
  48. Short self-test routine
  49. recommended polling time: ( 4) minutes.
  50. Extended self-test routine
  51. recommended polling time: ( 32) minutes.
  52. Conveyance self-test routine
  53. recommended polling time: ( 8) minutes.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0/0
  59. 5 Retired_Block_Count 0x0013 100 100 050 Pre-fail Always - 0
  60. 9 Power_On_Hours_and_Msec 0x0012 100 100 000 Old_age Always - 1114h+00m+00.000s
  61. 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 7
  62. 162 Unknown_Attribute 0x0003 094 094 000 Pre-fail Always - 15
  63. 170 Reserve_Block_Count 0x0002 100 100 000 Old_age Always - 227
  64. 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
  65. 173 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 2424932
  66. 174 Unexpect_Power_Loss_Ct 0x0012 100 100 000 Old_age Always - 6
  67. 181 Program_Fail_Count 0x0012 100 100 000 Old_age Always - 0
  68. 187 Reported_Uncorrect 0x0012 100 100 000 Old_age Always - 0
  69. 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 6
  70. 194 Temperature_Celsius 0x0023 067 067 000 Pre-fail Always - 33
  71. 196 Reallocated_Event_Count 0x0000 100 100 000 Old_age Offline - 0
  72. 218 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
  73. 231 SSD_Life_Left 0x0013 100 100 000 Pre-fail Always - 98
  74. 241 Lifetime_Writes_GiB 0x0012 100 100 000 Old_age Always - 2213
  75. 242 Lifetime_Reads_GiB 0x0012 100 100 000 Old_age Always - 262
  76.  
  77. SMART Error Log Version: 1
  78. No Errors Logged
  79.  
  80. SMART Self-test log structure revision number 1
  81. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  82. # 1 Extended offline Completed without error 00% 830 -
  83.  
  84. SMART Selective self-test log data structure revision number 0
  85. Note: revision number not 1 implies that no selective self-test has ever been run
  86. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  87. 1 0 0 Not_testing
  88. 2 0 0 Not_testing
  89. 3 0 0 Not_testing
  90. 4 0 0 Not_testing
  91. 5 0 0 Not_testing
  92. Selective self-test flags (0x0):
  93. After scanning selected spans, do NOT read-scan remainder of disk.
  94. If Selective self-test is pending on power-up, resume after 0 minute delay.