  1. smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-431.3.1.el6.x86_64] (local build)
  2. Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: ST1000NM0033-9ZM173
  6. Serial Number: Z1W0Q9T9
  7. LU WWN Device Id: 5 000c50 064efd218
  8. Firmware Version: SN03
  9. User Capacity: 1 000 204 886 016 bytes [1,00 TB]
  10. Sector Size: 512 bytes logical/physical
  11. Device is: Not in smartctl database [for details use: -P showall]
  12. ATA Version is: 8
  13. ATA Standard is: ACS-2 (revision not indicated)
  14. Local Time is: Fri Apr 18 03:07:00 2014 MSK
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x82) Offline data collection activity
  23. was completed without error.
  24. Auto Offline Data Collection: Enabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26. without error or no self-test has ever
  27. been run.
  28. Total time to complete Offline
  29. data collection: ( 600) seconds.
  30. Offline data collection
  31. capabilities: (0x7b) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. Offline surface scan supported.
  36. Self-test supported.
  37. Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 1) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 119) minutes.
  48. Conveyance self-test routine
  49. recommended polling time: ( 2) minutes.
  50. SCT capabilities: (0x50bd) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 10
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x000f 081 064 044 Pre-fail Always - 124220783
  59. 3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0
  60. 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 12
  61. 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x000f 080 060 030 Pre-fail Always - 113340622
  63. 9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 2719
  64. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  65. 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 12
  66. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  67. 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
  68. 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
  69. 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
  70. 190 Airflow_Temperature_Cel 0x0022 074 068 045 Old_age Always - 26 (Min/Max 25/28)
  71. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
  72. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 11
  73. 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 124
  74. 194 Temperature_Celsius 0x0022 026 040 000 Old_age Always - 26 (0 19 0 0 0)
  75. 195 Hardware_ECC_Recovered 0x001a 024 011 000 Old_age Always - 124220783
  76. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
  77. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
  78. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  79.  
  80. SMART Error Log Version: 1
  81. No Errors Logged
  82.  
  83. SMART Self-test log structure revision number 1
  84. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  85. # 1 Extended offline Completed without error 00% 2698 -
  86.  
  87. SMART Selective self-test log data structure revision number 1
  88. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  89. 1 0 0 Not_testing
  90. 2 0 0 Not_testing
  91. 3 0 0 Not_testing
  92. 4 0 0 Not_testing
  93. 5 0 0 Not_testing
  94. Selective self-test flags (0x0):
  95. After scanning selected spans, do NOT read-scan remainder of disk.
  96. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement