Advertisement
Guest User

Untitled

a guest
May 9th, 2017
118
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 47.67 KB | None | 0 0
  1. 2017-05-09 17:25:18.770 [WARN ] [o.config.core.ConfigDispatcher] - Main openHAB configuration file 'configurations/openhab.cfg' does not exist.
  2. 2017-05-09 17:25:18.774 [INFO ] [.o.core.internal.CoreActivator] - openHAB runtime has been started (v1.8.3).
  3. 2017-05-09 17:25:19.296 [INFO ] [o.o.i.s.i.DiscoveryServiceImpl] - mDNS service has been started
  4. 2017-05-09 17:25:19.966 [INFO ] [o.o.i.s.i.DiscoveryServiceImpl] - Service Discovery initialization completed.
  5. 2017-05-09 17:25:20.512 [INFO ] [penhab.io.rest.RESTApplication] - Started REST API at /rest
  6. 2017-05-09 17:25:29.177 [INFO ] [c.internal.ModelRepositoryImpl] - Loading model 'demo.sitemap'
  7. 2017-05-09 17:25:29.254 [INFO ] [c.internal.ModelRepositoryImpl] - Loading model 'demo.items'
  8. 2017-05-09 17:25:30.477 [INFO ] [.o.u.w.i.servlet.WebAppServlet] - Started Classic UI at /classicui/openhab.app
  9. 2017-05-09 17:25:33.696 [DEBUG] [o.b.m.internal.ModbusActivator] - Modbus binding has been started.
  10. 2017-05-09 17:25:33.735 [DEBUG] [.modbus.internal.ModbusBinding] - modbusSlave 'onoffcmdstat' instanciated
  11. 2017-05-09 17:25:33.744 [DEBUG] [.modbus.internal.ModbusBinding] - Parsed the following slave->endpoint configurations: {onoffcmdstat=EndpointPoolConfiguration@6a4f4974[passivateBorrowMinMillis=1500,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1,connectTimeoutMillis=0]}. If the endpoint is same, connections are shared between the instances.
  12. 2017-05-09 17:25:33.745 [DEBUG] [.modbus.internal.ModbusBinding] - Parsed the following pool configurations: {ModbusSerialSlaveEndpoint@396161bc[portName=COM4]=EndpointPoolConfiguration@6a4f4974[passivateBorrowMinMillis=1500,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1,connectTimeoutMillis=0]}
  13. 2017-05-09 17:25:33.745 [DEBUG] [.modbus.internal.ModbusBinding] - config looked good
  14. 2017-05-09 17:25:33.746 [INFO ] [.service.AbstractActiveService] - Modbus Polling Service has been started
  15. 2017-05-09 17:25:33.764 [TRACE] [dbusSlaveConnectionFactoryImpl] - Created connection SerialConnection@fcd77fe[portName=COM4,port=<null>] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  16. 2017-05-09 17:25:34.281 [TRACE] [pi.modbus.net.SerialConnection] - Got Port Identifier
  17. 2017-05-09 17:25:34.344 [TRACE] [pi.modbus.net.SerialConnection] - Got Serial Port
  18. 2017-05-09 17:25:34.370 [TRACE] [pi.modbus.net.SerialConnection] - i/o Streams prepared
  19. 2017-05-09 17:25:34.371 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] connection SerialConnection@fcd77fe[portName=COM4,port=//./COM4] -> true
  20. 2017-05-09 17:25:34.371 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@fcd77fe[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] took 624 ms
  21. 2017-05-09 17:25:34.372 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  22. 2017-05-09 17:25:37.382 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  23. 2017-05-09 17:25:37.384 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  24. 2017-05-09 17:25:37.384 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  25. 2017-05-09 17:25:37.393 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@7bd652c8 (unit id 1 & transaction 1). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  26. 2017-05-09 17:25:38.897 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  27. 2017-05-09 17:25:41.907 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  28. 2017-05-09 17:25:41.909 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  29. 2017-05-09 17:25:41.910 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  30. 2017-05-09 17:25:41.919 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@7bd652c8 (unit id 1 & transaction 1). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  31. 2017-05-09 17:25:43.420 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  32. 2017-05-09 17:25:46.430 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  33. 2017-05-09 17:25:46.431 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  34. 2017-05-09 17:25:46.434 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  35. 2017-05-09 17:25:46.443 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@7bd652c8 (unit id 1 & transaction 1). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  36. 2017-05-09 17:25:46.445 [ERROR] [w.m.io.ModbusSerialTransaction] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@7bd652c8. Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  37. 2017-05-09 17:25:46.446 [ERROR] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@7bd652c8. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]. Connection: SerialConnection@fcd77fe[portName=COM4,port=//./COM4]
  38. 2017-05-09 17:25:55.479 [TRACE] [dbusSlaveConnectionFactoryImpl] - Created connection SerialConnection@adb17f8[portName=COM4,port=<null>] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  39. 2017-05-09 17:25:55.483 [TRACE] [pi.modbus.net.SerialConnection] - Got Port Identifier
  40. 2017-05-09 17:25:55.545 [TRACE] [pi.modbus.net.SerialConnection] - Got Serial Port
  41. 2017-05-09 17:25:55.573 [TRACE] [pi.modbus.net.SerialConnection] - i/o Streams prepared
  42. 2017-05-09 17:25:55.577 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] connection SerialConnection@adb17f8[portName=COM4,port=//./COM4] -> true
  43. 2017-05-09 17:25:55.581 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@adb17f8[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] took 102 ms
  44. 2017-05-09 17:25:55.587 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  45. 2017-05-09 17:25:58.598 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  46. 2017-05-09 17:25:58.602 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  47. 2017-05-09 17:25:58.606 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  48. 2017-05-09 17:25:58.617 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@349f2524 (unit id 1 & transaction 2). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  49. 2017-05-09 17:26:00.124 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  50. 2017-05-09 17:26:03.135 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  51. 2017-05-09 17:26:03.137 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  52. 2017-05-09 17:26:03.142 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  53. 2017-05-09 17:26:03.154 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@349f2524 (unit id 1 & transaction 2). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  54. 2017-05-09 17:26:04.661 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  55. 2017-05-09 17:26:10.672 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  56. 2017-05-09 17:26:10.675 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  57. 2017-05-09 17:26:10.678 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  58. 2017-05-09 17:26:10.690 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@349f2524 (unit id 1 & transaction 2). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  59. 2017-05-09 17:26:10.699 [ERROR] [w.m.io.ModbusSerialTransaction] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@349f2524. Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  60. 2017-05-09 17:26:10.705 [ERROR] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@349f2524. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]. Connection: SerialConnection@adb17f8[portName=COM4,port=//./COM4]
  61. 2017-05-09 17:26:19.732 [TRACE] [dbusSlaveConnectionFactoryImpl] - Created connection SerialConnection@1e5d336f[portName=COM4,port=<null>] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  62. 2017-05-09 17:26:19.737 [TRACE] [pi.modbus.net.SerialConnection] - Got Port Identifier
  63. 2017-05-09 17:26:19.798 [TRACE] [pi.modbus.net.SerialConnection] - Got Serial Port
  64. 2017-05-09 17:26:19.828 [TRACE] [pi.modbus.net.SerialConnection] - i/o Streams prepared
  65. 2017-05-09 17:26:19.831 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] connection SerialConnection@1e5d336f[portName=COM4,port=//./COM4] -> true
  66. 2017-05-09 17:26:19.835 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@1e5d336f[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] took 103 ms
  67. 2017-05-09 17:26:19.845 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  68. 2017-05-09 17:26:19.994 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  69. 2017-05-09 17:26:20.027 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Response: 01 02 01 00 a1 88
  70. 2017-05-09 17:26:20.039 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] connection SerialConnection@1e5d336f[portName=COM4,port=//./COM4] -> true
  71. 2017-05-09 17:26:20.043 [TRACE] [dbusSlaveConnectionFactoryImpl] - Passivating connection SerialConnection@1e5d336f[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]...
  72. 2017-05-09 17:26:20.050 [TRACE] [dbusSlaveConnectionFactoryImpl] - (passivate) Connection SerialConnection@1e5d336f[portName=COM4,port=//./COM4] (endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]) age (218ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
  73. 2017-05-09 17:26:20.056 [TRACE] [dbusSlaveConnectionFactoryImpl] - ...Passivated connection SerialConnection@1e5d336f[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  74. 2017-05-09 17:26:20.065 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): returned connection for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  75. 2017-05-09 17:26:20.067 [TRACE] [et.wimpi.modbus.util.BitVector] - Get bit #0
  76. 2017-05-09 17:26:29.071 [TRACE] [dbusSlaveConnectionFactoryImpl] - Waited 0ms (passivateBorrowMinMillis 1500ms) before giving returning connection SerialConnection@1e5d336f[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4], to ensure delay between transactions.
  77. 2017-05-09 17:26:29.077 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] connection SerialConnection@1e5d336f[portName=COM4,port=//./COM4] -> true
  78. 2017-05-09 17:26:29.082 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@1e5d336f[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] took 11 ms
  79. 2017-05-09 17:26:29.086 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  80. 2017-05-09 17:26:35.098 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  81. 2017-05-09 17:26:35.100 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  82. 2017-05-09 17:26:35.103 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  83. 2017-05-09 17:26:35.114 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d751f8 (unit id 1 & transaction 4). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  84. 2017-05-09 17:26:36.621 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  85. 2017-05-09 17:26:42.633 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  86. 2017-05-09 17:26:42.634 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  87. 2017-05-09 17:26:42.636 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  88. 2017-05-09 17:26:42.646 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d751f8 (unit id 1 & transaction 4). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  89. 2017-05-09 17:26:44.148 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  90. 2017-05-09 17:26:47.160 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  91. 2017-05-09 17:26:47.162 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  92. 2017-05-09 17:26:47.165 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  93. 2017-05-09 17:26:47.176 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d751f8 (unit id 1 & transaction 4). Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  94. 2017-05-09 17:26:47.182 [ERROR] [w.m.io.ModbusSerialTransaction] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d751f8. Serial parameters: SerialParameters@6529f820[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=3000]
  95. 2017-05-09 17:26:47.187 [ERROR] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@44d751f8. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]. Connection: SerialConnection@1e5d336f[portName=COM4,port=//./COM4]
  96. 2017-05-09 17:26:56.214 [TRACE] [dbusSlaveConnectionFactoryImpl] - Created connection SerialConnection@3fd1fe83[portName=COM4,port=<null>] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  97. 2017-05-09 17:26:56.219 [TRACE] [pi.modbus.net.SerialConnection] - Got Port Identifier
  98. 2017-05-09 17:26:56.280 [TRACE] [pi.modbus.net.SerialConnection] - Got Serial Port
  99. 2017-05-09 17:26:56.308 [TRACE] [pi.modbus.net.SerialConnection] - i/o Streams prepared
  100. 2017-05-09 17:26:56.313 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] connection SerialConnection@3fd1fe83[portName=COM4,port=//./COM4] -> true
  101. 2017-05-09 17:26:56.318 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@3fd1fe83[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] took 103 ms
  102. 2017-05-09 17:26:56.323 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  103. 2017-05-09 17:26:56.469 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  104. 2017-05-09 17:26:56.497 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Response: 01 02 01 01 60 48
  105. 2017-05-09 17:26:56.508 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4] connection SerialConnection@3fd1fe83[portName=COM4,port=//./COM4] -> true
  106. 2017-05-09 17:26:56.513 [TRACE] [dbusSlaveConnectionFactoryImpl] - Passivating connection SerialConnection@3fd1fe83[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]...
  107. 2017-05-09 17:26:56.517 [TRACE] [dbusSlaveConnectionFactoryImpl] - (passivate) Connection SerialConnection@3fd1fe83[portName=COM4,port=//./COM4] (endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]) age (205ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
  108. 2017-05-09 17:26:56.519 [TRACE] [dbusSlaveConnectionFactoryImpl] - ...Passivated connection SerialConnection@3fd1fe83[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  109. 2017-05-09 17:26:56.522 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): returned connection for endpoint ModbusSerialSlaveEndpoint@396161bc[portName=COM4]
  110. 2017-05-09 17:26:56.524 [TRACE] [et.wimpi.modbus.util.BitVector] - Get bit #0
  111. 2017-05-09 17:26:56.801 [INFO ] [penhab.io.rest.RESTApplication] - Stopped REST API
  112. 2017-05-09 17:27:31.241 [WARN ] [o.config.core.ConfigDispatcher] - Main openHAB configuration file 'configurations/openhab.cfg' does not exist.
  113. 2017-05-09 17:27:31.255 [INFO ] [.o.core.internal.CoreActivator] - openHAB runtime has been started (v1.8.3).
  114. 2017-05-09 17:27:31.799 [INFO ] [o.o.i.s.i.DiscoveryServiceImpl] - mDNS service has been started
  115. 2017-05-09 17:27:32.452 [INFO ] [o.o.i.s.i.DiscoveryServiceImpl] - Service Discovery initialization completed.
  116. 2017-05-09 17:27:33.026 [INFO ] [penhab.io.rest.RESTApplication] - Started REST API at /rest
  117. 2017-05-09 17:27:41.644 [INFO ] [c.internal.ModelRepositoryImpl] - Loading model 'demo.sitemap'
  118. 2017-05-09 17:27:41.743 [INFO ] [c.internal.ModelRepositoryImpl] - Loading model 'demo.items'
  119. 2017-05-09 17:27:42.703 [INFO ] [.o.u.w.i.servlet.WebAppServlet] - Started Classic UI at /classicui/openhab.app
  120. 2017-05-09 17:27:46.099 [DEBUG] [o.b.m.internal.ModbusActivator] - Modbus binding has been started.
  121. 2017-05-09 17:27:46.136 [DEBUG] [.modbus.internal.ModbusBinding] - modbusSlave 'onoffcmdstat' instanciated
  122. 2017-05-09 17:27:46.144 [DEBUG] [.modbus.internal.ModbusBinding] - Parsed the following slave->endpoint configurations: {onoffcmdstat=EndpointPoolConfiguration@4b3b77c[passivateBorrowMinMillis=500,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1,connectTimeoutMillis=0]}. If the endpoint is same, connections are shared between the instances.
  123. 2017-05-09 17:27:46.144 [DEBUG] [.modbus.internal.ModbusBinding] - Parsed the following pool configurations: {ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]=EndpointPoolConfiguration@4b3b77c[passivateBorrowMinMillis=500,interConnectDelayMillis=0,connectMaxTries=3,reconnectAfterMillis=-1,connectTimeoutMillis=0]}
  124. 2017-05-09 17:27:46.145 [DEBUG] [.modbus.internal.ModbusBinding] - config looked good
  125. 2017-05-09 17:27:46.145 [INFO ] [.service.AbstractActiveService] - Modbus Polling Service has been started
  126. 2017-05-09 17:27:46.162 [TRACE] [dbusSlaveConnectionFactoryImpl] - Created connection SerialConnection@f704476[portName=COM4,port=<null>] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  127. 2017-05-09 17:27:46.641 [TRACE] [pi.modbus.net.SerialConnection] - Got Port Identifier
  128. 2017-05-09 17:27:46.705 [TRACE] [pi.modbus.net.SerialConnection] - Got Serial Port
  129. 2017-05-09 17:27:46.739 [TRACE] [pi.modbus.net.SerialConnection] - i/o Streams prepared
  130. 2017-05-09 17:27:46.741 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@f704476[portName=COM4,port=//./COM4] -> true
  131. 2017-05-09 17:27:46.743 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@f704476[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] took 595 ms
  132. 2017-05-09 17:27:46.749 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  133. 2017-05-09 17:27:52.758 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  134. 2017-05-09 17:27:52.760 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  135. 2017-05-09 17:27:52.760 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  136. 2017-05-09 17:27:52.769 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2d2eb78e (unit id 1 & transaction 1). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  137. 2017-05-09 17:27:53.272 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  138. 2017-05-09 17:27:59.281 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  139. 2017-05-09 17:27:59.282 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  140. 2017-05-09 17:27:59.283 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  141. 2017-05-09 17:27:59.292 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2d2eb78e (unit id 1 & transaction 1). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  142. 2017-05-09 17:27:59.795 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  143. 2017-05-09 17:28:05.804 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  144. 2017-05-09 17:28:05.806 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  145. 2017-05-09 17:28:05.807 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  146. 2017-05-09 17:28:05.817 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2d2eb78e (unit id 1 & transaction 1). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  147. 2017-05-09 17:28:05.819 [ERROR] [w.m.io.ModbusSerialTransaction] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@2d2eb78e. Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  148. 2017-05-09 17:28:05.821 [ERROR] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@2d2eb78e. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]. Connection: SerialConnection@f704476[portName=COM4,port=//./COM4]
  149. 2017-05-09 17:28:14.852 [TRACE] [dbusSlaveConnectionFactoryImpl] - Created connection SerialConnection@61434c66[portName=COM4,port=<null>] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  150. 2017-05-09 17:28:14.856 [TRACE] [pi.modbus.net.SerialConnection] - Got Port Identifier
  151. 2017-05-09 17:28:14.917 [TRACE] [pi.modbus.net.SerialConnection] - Got Serial Port
  152. 2017-05-09 17:28:14.945 [TRACE] [pi.modbus.net.SerialConnection] - i/o Streams prepared
  153. 2017-05-09 17:28:14.949 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@61434c66[portName=COM4,port=//./COM4] -> true
  154. 2017-05-09 17:28:14.953 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@61434c66[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] took 101 ms
  155. 2017-05-09 17:28:14.959 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  156. 2017-05-09 17:28:20.971 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  157. 2017-05-09 17:28:20.974 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  158. 2017-05-09 17:28:20.977 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  159. 2017-05-09 17:28:20.987 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@767b43e0 (unit id 1 & transaction 2). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  160. 2017-05-09 17:28:21.495 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  161. 2017-05-09 17:28:21.643 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  162. 2017-05-09 17:28:21.676 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Response: 01 02 01 01 60 48
  163. 2017-05-09 17:28:21.688 [INFO ] [w.m.io.ModbusSerialTransaction] - execute eventually succeeded with 1 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@767b43e0. Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  164. 2017-05-09 17:28:21.698 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@61434c66[portName=COM4,port=//./COM4] -> true
  165. 2017-05-09 17:28:21.703 [TRACE] [dbusSlaveConnectionFactoryImpl] - Passivating connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]...
  166. 2017-05-09 17:28:21.708 [TRACE] [dbusSlaveConnectionFactoryImpl] - (passivate) Connection SerialConnection@61434c66[portName=COM4,port=//./COM4] (endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]) age (6760ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
  167. 2017-05-09 17:28:21.713 [TRACE] [dbusSlaveConnectionFactoryImpl] - ...Passivated connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  168. 2017-05-09 17:28:21.717 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): returned connection for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  169. 2017-05-09 17:28:21.720 [TRACE] [et.wimpi.modbus.util.BitVector] - Get bit #0
  170. 2017-05-09 17:28:30.723 [TRACE] [dbusSlaveConnectionFactoryImpl] - Waited 0ms (passivateBorrowMinMillis 500ms) before giving returning connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4], to ensure delay between transactions.
  171. 2017-05-09 17:28:30.731 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@61434c66[portName=COM4,port=//./COM4] -> true
  172. 2017-05-09 17:28:30.738 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@61434c66[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] took 14 ms
  173. 2017-05-09 17:28:30.744 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  174. 2017-05-09 17:28:36.754 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  175. 2017-05-09 17:28:36.759 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  176. 2017-05-09 17:28:36.763 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  177. 2017-05-09 17:28:36.774 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@10203d54 (unit id 1 & transaction 3). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  178. 2017-05-09 17:28:37.283 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  179. 2017-05-09 17:28:43.294 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  180. 2017-05-09 17:28:43.297 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  181. 2017-05-09 17:28:43.300 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  182. 2017-05-09 17:28:43.310 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@10203d54 (unit id 1 & transaction 3). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  183. 2017-05-09 17:28:43.817 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  184. 2017-05-09 17:28:43.965 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  185. 2017-05-09 17:28:43.995 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Response: 01 02 01 00 a1 88
  186. 2017-05-09 17:28:44.007 [INFO ] [w.m.io.ModbusSerialTransaction] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@10203d54. Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  187. 2017-05-09 17:28:44.014 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@61434c66[portName=COM4,port=//./COM4] -> true
  188. 2017-05-09 17:28:44.019 [TRACE] [dbusSlaveConnectionFactoryImpl] - Passivating connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]...
  189. 2017-05-09 17:28:44.024 [TRACE] [dbusSlaveConnectionFactoryImpl] - (passivate) Connection SerialConnection@61434c66[portName=COM4,port=//./COM4] (endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]) age (29076ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
  190. 2017-05-09 17:28:44.030 [TRACE] [dbusSlaveConnectionFactoryImpl] - ...Passivated connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  191. 2017-05-09 17:28:44.035 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): returned connection for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  192. 2017-05-09 17:28:44.037 [TRACE] [et.wimpi.modbus.util.BitVector] - Get bit #0
  193. 2017-05-09 17:28:53.039 [TRACE] [dbusSlaveConnectionFactoryImpl] - Waited 0ms (passivateBorrowMinMillis 500ms) before giving returning connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4], to ensure delay between transactions.
  194. 2017-05-09 17:28:53.047 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@61434c66[portName=COM4,port=//./COM4] -> true
  195. 2017-05-09 17:28:53.051 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@61434c66[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] took 12 ms
  196. 2017-05-09 17:28:53.058 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  197. 2017-05-09 17:29:05.069 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  198. 2017-05-09 17:29:05.072 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  199. 2017-05-09 17:29:05.075 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  200. 2017-05-09 17:29:05.086 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@357a5836 (unit id 1 & transaction 4). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  201. 2017-05-09 17:29:05.592 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  202. 2017-05-09 17:29:11.604 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  203. 2017-05-09 17:29:11.607 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  204. 2017-05-09 17:29:11.610 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  205. 2017-05-09 17:29:11.622 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@357a5836 (unit id 1 & transaction 4). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  206. 2017-05-09 17:29:12.130 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  207. 2017-05-09 17:29:12.276 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  208. 2017-05-09 17:29:12.309 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Response: 01 02 01 01 60 48
  209. 2017-05-09 17:29:12.318 [INFO ] [w.m.io.ModbusSerialTransaction] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@357a5836. Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  210. 2017-05-09 17:29:12.322 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@61434c66[portName=COM4,port=//./COM4] -> true
  211. 2017-05-09 17:29:12.324 [TRACE] [dbusSlaveConnectionFactoryImpl] - Passivating connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]...
  212. 2017-05-09 17:29:12.330 [TRACE] [dbusSlaveConnectionFactoryImpl] - (passivate) Connection SerialConnection@61434c66[portName=COM4,port=//./COM4] (endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]) age (57380ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
  213. 2017-05-09 17:29:12.337 [TRACE] [dbusSlaveConnectionFactoryImpl] - ...Passivated connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  214. 2017-05-09 17:29:12.357 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): returned connection for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  215. 2017-05-09 17:29:12.361 [TRACE] [et.wimpi.modbus.util.BitVector] - Get bit #0
  216. 2017-05-09 17:29:21.364 [TRACE] [dbusSlaveConnectionFactoryImpl] - Waited 0ms (passivateBorrowMinMillis 500ms) before giving returning connection SerialConnection@61434c66[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4], to ensure delay between transactions.
  217. 2017-05-09 17:29:21.371 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@61434c66[portName=COM4,port=//./COM4] -> true
  218. 2017-05-09 17:29:21.377 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@61434c66[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] took 14 ms
  219. 2017-05-09 17:29:21.384 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  220. 2017-05-09 17:29:27.393 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  221. 2017-05-09 17:29:27.396 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  222. 2017-05-09 17:29:27.399 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  223. 2017-05-09 17:29:27.411 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@496d30fe (unit id 1 & transaction 5). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  224. 2017-05-09 17:29:27.918 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  225. 2017-05-09 17:29:33.929 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  226. 2017-05-09 17:29:33.930 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  227. 2017-05-09 17:29:33.931 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  228. 2017-05-09 17:29:33.941 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@496d30fe (unit id 1 & transaction 5). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  229. 2017-05-09 17:29:34.445 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  230. 2017-05-09 17:29:46.457 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  231. 2017-05-09 17:29:46.460 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  232. 2017-05-09 17:29:46.463 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  233. 2017-05-09 17:29:46.474 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 3/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@496d30fe (unit id 1 & transaction 5). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  234. 2017-05-09 17:29:46.481 [ERROR] [w.m.io.ModbusSerialTransaction] - execute reached max tries 3, throwing last error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@496d30fe. Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  235. 2017-05-09 17:29:46.491 [ERROR] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): Error getting modbus data for request net.wimpi.modbus.msg.ReadInputDiscretesRequest@496d30fe. Error: I/O exception - failed to read. Endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]. Connection: SerialConnection@61434c66[portName=COM4,port=//./COM4]
  236. 2017-05-09 17:29:55.520 [TRACE] [dbusSlaveConnectionFactoryImpl] - Created connection SerialConnection@77a144af[portName=COM4,port=<null>] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  237. 2017-05-09 17:29:55.529 [TRACE] [pi.modbus.net.SerialConnection] - Got Port Identifier
  238. 2017-05-09 17:29:55.590 [TRACE] [pi.modbus.net.SerialConnection] - Got Serial Port
  239. 2017-05-09 17:29:55.618 [TRACE] [pi.modbus.net.SerialConnection] - i/o Streams prepared
  240. 2017-05-09 17:29:55.620 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@77a144af[portName=COM4,port=//./COM4] -> true
  241. 2017-05-09 17:29:55.623 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@77a144af[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] took 104 ms
  242. 2017-05-09 17:29:55.630 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  243. 2017-05-09 17:30:07.640 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  244. 2017-05-09 17:30:07.643 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  245. 2017-05-09 17:30:07.646 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  246. 2017-05-09 17:30:07.658 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1a65293 (unit id 1 & transaction 6). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  247. 2017-05-09 17:30:08.165 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  248. 2017-05-09 17:30:14.176 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  249. 2017-05-09 17:30:14.177 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  250. 2017-05-09 17:30:14.178 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  251. 2017-05-09 17:30:14.187 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1a65293 (unit id 1 & transaction 6). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  252. 2017-05-09 17:30:14.694 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  253. 2017-05-09 17:30:14.842 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  254. 2017-05-09 17:30:14.870 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Response: 01 02 01 00 a1 88
  255. 2017-05-09 17:30:14.882 [INFO ] [w.m.io.ModbusSerialTransaction] - execute eventually succeeded with 2 re-tries. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@1a65293. Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  256. 2017-05-09 17:30:14.888 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@77a144af[portName=COM4,port=//./COM4] -> true
  257. 2017-05-09 17:30:14.894 [TRACE] [dbusSlaveConnectionFactoryImpl] - Passivating connection SerialConnection@77a144af[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]...
  258. 2017-05-09 17:30:14.898 [TRACE] [dbusSlaveConnectionFactoryImpl] - (passivate) Connection SerialConnection@77a144af[portName=COM4,port=//./COM4] (endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]) age (19278ms) is below the reconnectAfterMillis (-1ms) limit. Keep the connection open.
  259. 2017-05-09 17:30:14.905 [TRACE] [dbusSlaveConnectionFactoryImpl] - ...Passivated connection SerialConnection@77a144af[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  260. 2017-05-09 17:30:14.907 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): returned connection for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4]
  261. 2017-05-09 17:30:14.910 [TRACE] [et.wimpi.modbus.util.BitVector] - Get bit #0
  262. 2017-05-09 17:30:23.911 [TRACE] [dbusSlaveConnectionFactoryImpl] - Waited 0ms (passivateBorrowMinMillis 500ms) before giving returning connection SerialConnection@77a144af[portName=COM4,port=//./COM4] for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4], to ensure delay between transactions.
  263. 2017-05-09 17:30:23.917 [TRACE] [dbusSlaveConnectionFactoryImpl] - Validating endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] connection SerialConnection@77a144af[portName=COM4,port=//./COM4] -> true
  264. 2017-05-09 17:30:23.922 [TRACE] [.b.modbus.internal.ModbusSlave] - ModbusSlave (onoffcmdstat): borrowing connection (got SerialConnection@77a144af[portName=COM4,port=//./COM4]) for endpoint ModbusSerialSlaveEndpoint@2a8ad745[portName=COM4] took 11 ms
  265. 2017-05-09 17:30:23.929 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  266. 2017-05-09 17:30:35.940 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  267. 2017-05-09 17:30:35.942 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  268. 2017-05-09 17:30:35.945 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  269. 2017-05-09 17:30:35.957 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 1/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@216c6899 (unit id 1 & transaction 7). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  270. 2017-05-09 17:30:36.464 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb
  271. 2017-05-09 17:30:41.926 [INFO ] [penhab.io.rest.RESTApplication] - Stopped REST API
  272. 2017-05-09 17:30:42.476 [TRACE] [i.modbus.io.ModbusRTUTransport] - Managed to read at least one byte
  273. 2017-05-09 17:30:42.479 [ERROR] [i.modbus.io.ModbusRTUTransport] - Last request: 01 02 00 00 00 02 f9 cb
  274. 2017-05-09 17:30:42.481 [ERROR] [i.modbus.io.ModbusRTUTransport] - failed to read: Error reading response (EOF)
  275. 2017-05-09 17:30:42.493 [ERROR] [w.m.io.ModbusSerialTransaction] - execute try 2/3 error: I/O exception - failed to read. Request: net.wimpi.modbus.msg.ReadInputDiscretesRequest@216c6899 (unit id 1 & transaction 7). Serial parameters: SerialParameters@72cf1582[portName=COM4,baudRate=19200,flowControlIn=none,flowControlOut=none,databits=8,stopbits=1,parity=even,encoding=rtu,echo=false,receiveTimeoutMillis=6000]
  276. 2017-05-09 17:30:42.999 [DEBUG] [i.modbus.io.ModbusRTUTransport] - Sent: 01 02 00 00 00 02 f9 cb