  1. CCTV:
  2. For remote viewing, we will require an active ethernet connection to the CCTV recorder position.
  3.  
  4. NVR:
  5. DS-7608NI-K2/8P - 8 Channel NVR with POE ports on the back.
  6. MUST Ask for supplier to provide 2TB HDD also.
  7.  
  8. Monitor:
  9. DS-D5022QE-B - 21.5" CCTV Monitor with VGA+HDMI input.
  10.  
  11. Camera options:
  12. Best quality & can be used internal+external: Hikvision DS-2CD2755FWD-IZS - Varifocal 5MP Network Dome Camera
  13. Slightly lower quality but can still be used anywhere: Hikvision DS-2CD2742FWD-I(Z)(S) - 4MP Varifocal Dome Network Camera#
  14.  
  15. xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
  16.  
  17. Intruder Alarm:
  18. Parts Needed:
  19. 1x CAC-0001 (Texecom Premier 88 Control Panel. 8 zones on panel, if more than 8 detectors then you will need expanders.)
  20. 1x 8XP (Texecom Expanders. You will need 1x for every 8 detectors, so if you have 12 in total, you only need one as main panel has 8 zones)
  21. 2x LCDP (Texecom Alarm Keypad with Proximity, change number for required number of keypads)
  22. 1x CDB-0001 (Texecom Proximity Tags, pack of 5)
  23. ?x AFB-0001 (Texecom Anti-Masking Dualtech PIR. Change number for how many detectors needed)
  24. 4x RS007 (Heavy Duty Roller Shutter Contact. 4x for 4 doors)
  25. ?x SC550WH (Heavy Duty White Door Contact. Change number for number required.)
  26. 1x AEB-0001 (Texecom Impaq Inertia detector, detects vibrations to protect window. If more than 1 window, change numbers 1 per.)
  27. 1x Premier Elite Com2400 (Onboard communicator, provides comms for board.
  28. 1x SD1+ Speech Dialler for dialling phone of customer.
  29. 1x Texecom Odyssey X-BE Backplate (Real Bellbox Backplate)
  30. 1x Texecom Odyssey X-D Backplate (Dummy Backplate)
  31. 2x Texecom Odyssey X3 Bellbox Cover (As previous, white frame with blue bottom.)
  32.  
  33. Intuder Panel will require an active phone line to main cabinet position.
  34. It will also require a space measuring at least (H x W x D mm) 600 x 430 x 100 for the panel and all other units.
  35.  
  36. Approx 2 Days to install and test with no provision for running cables.