Guest User

Untitled

a guest
Nov 16th, 2017
230
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 6.61 KB | None | 0 0
  1. shinji@zeus:~$ sudo smartctl --health /dev/sda
  2. smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.13.0-16-generic] (local build)
  3. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF READ SMART DATA SECTION ===
  6. SMART overall-health self-assessment test result: PASSED
  7.  
  8. shinji@zeus:~$ sudo smartctl --all /dev/sda
  9. smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.13.0-16-generic] (local build)
  10. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  11.  
  12. === START OF INFORMATION SECTION ===
  13. Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
  14. Device Model: TOSHIBA DT01ACA200
  15. Serial Number: 23IMHPXAS
  16. LU WWN Device Id: 5 000039 ff3c8de03
  17. Firmware Version: MX4OABB0
  18. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  19. Sector Sizes: 512 bytes logical, 4096 bytes physical
  20. Rotation Rate: 7200 rpm
  21. Form Factor: 3.5 inches
  22. Device is: In smartctl database [for details use: -P show]
  23. ATA Version is: ATA8-ACS T13/1699-D revision 4
  24. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  25. Local Time is: Thu Nov 16 20:15:12 2017 UTC
  26. SMART support is: Available - device has SMART capability.
  27. SMART support is: Enabled
  28.  
  29. === START OF READ SMART DATA SECTION ===
  30. SMART overall-health self-assessment test result: PASSED
  31.  
  32. General SMART Values:
  33. Offline data collection status: (0x84) Offline data collection activity
  34. was suspended by an interrupting command from host.
  35. Auto Offline Data Collection: Enabled.
  36. Self-test execution status: ( 0) The previous self-test routine completed
  37. without error or no self-test has ever
  38. been run.
  39. Total time to complete Offline
  40. data collection: (15683) seconds.
  41. Offline data collection
  42. capabilities: (0x5b) SMART execute Offline immediate.
  43. Auto Offline data collection on/off support.
  44. Suspend Offline collection upon new
  45. command.
  46. Offline surface scan supported.
  47. Self-test supported.
  48. No Conveyance Self-test supported.
  49. Selective Self-test supported.
  50. SMART capabilities: (0x0003) Saves SMART data before entering
  51. power-saving mode.
  52. Supports SMART auto save timer.
  53. Error logging capability: (0x01) Error logging supported.
  54. General Purpose Logging supported.
  55. Short self-test routine
  56. recommended polling time: ( 1) minutes.
  57. Extended self-test routine
  58. recommended polling time: ( 262) minutes.
  59. SCT capabilities: (0x003d) SCT Status supported.
  60. SCT Error Recovery Control supported.
  61. SCT Feature Control supported.
  62. SCT Data Table supported.
  63.  
  64. SMART Attributes Data Structure revision number: 16
  65. Vendor Specific SMART Attributes with Thresholds:
  66. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  67. 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
  68. 2 Throughput_Performance 0x0005 139 139 054 Pre-fail Offline - 73
  69. 3 Spin_Up_Time 0x0007 128 128 024 Pre-fail Always - 295 (Average 295)
  70. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 120
  71. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
  72. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  73. 8 Seek_Time_Performance 0x0005 124 124 020 Pre-fail Offline - 33
  74. 9 Power_On_Hours 0x0012 099 099 000 Old_age Always - 13936
  75. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  76. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 120
  77. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 287
  78. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 287
  79. 194 Temperature_Celsius 0x0002 253 253 000 Old_age Always - 20 (Min/Max -1/39)
  80. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
  81. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
  82. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  83. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
  84.  
  85. SMART Error Log Version: 1
  86. No Errors Logged
  87.  
  88. SMART Self-test log structure revision number 1
  89. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  90. # 1 Short offline Completed without error 00% 13915 -
  91. # 2 Short offline Completed without error 00% 13913 -
  92. # 3 Short offline Completed without error 00% 13913 -
  93. # 4 Short offline Completed without error 00% 13030 -
  94. # 5 Short offline Completed without error 00% 13028 -
  95. # 6 Short offline Completed without error 00% 13028 -
  96. # 7 Short offline Completed without error 00% 11353 -
  97. # 8 Short offline Completed without error 00% 11352 -
  98. # 9 Short offline Completed without error 00% 11351 -
  99. #10 Short offline Completed without error 00% 10400 -
  100. #11 Short offline Completed without error 00% 10392 -
  101. #12 Short offline Completed without error 00% 10392 -
  102. #13 Short offline Completed without error 00% 10294 -
  103. #14 Short offline Completed without error 00% 10199 -
  104. #15 Short offline Completed without error 00% 10155 -
  105. #16 Short offline Completed without error 00% 10135 -
  106. #17 Short offline Completed without error 00% 10028 -
  107. #18 Short offline Completed without error 00% 10015 -
  108. #19 Short offline Completed without error 00% 10006 -
  109. #20 Short offline Completed without error 00% 9945 -
  110. #21 Short offline Completed without error 00% 9939 -
  111.  
  112. SMART Selective self-test log data structure revision number 1
  113. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  114. 1 0 0 Not_testing
  115. 2 0 0 Not_testing
  116. 3 0 0 Not_testing
  117. 4 0 0 Not_testing
  118. 5 0 0 Not_testing
  119. Selective self-test flags (0x0):
  120. After scanning selected spans, do NOT read-scan remainder of disk.
  121. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement