  1. ubuntu@ubuntu:~$ sudo smartctl --all /dev/sda
  2. smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
  3. Home page is http://smartmontools.sourceforge.net/
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Device Model: SAMSUNG HM321HI
  7. Serial Number: S24PJ1NZ600401
  8. Firmware Version: 2AJ10001
  9. User Capacity: 320.072.933.376 bytes
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: 8
  12. ATA Standard is: Not recognized. Minor revision code: 0x28
  13. Local Time is: Sun Mar 6 21:52:19 2011 UTC
  14.  
  15. ==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details.
  16.  
  17. SMART support is: Available - device has SMART capability.
  18. SMART support is: Enabled
  19.  
  20. === START OF READ SMART DATA SECTION ===
  21. SMART overall-health self-assessment test result: PASSED
  22.  
  23. General SMART Values:
  24. Offline data collection status: (0x00) Offline data collection activity
  25. was never started.
  26. Auto Offline Data Collection: Disabled.
  27. Self-test execution status: ( 0) The previous self-test routine completed
  28. without error or no self-test has ever
  29. been run.
  30. Total time to complete Offline
  31. data collection: (4680) seconds.
  32. Offline data collection
  33. capabilities: (0x5b) SMART execute Offline immediate.
  34. Auto Offline data collection on/off support.
  35. Suspend Offline collection upon new
  36. command.
  37. Offline surface scan supported.
  38. Self-test supported.
  39. No Conveyance Self-test supported.
  40. Selective Self-test supported.
  41. SMART capabilities: (0x0003) Saves SMART data before entering
  42. power-saving mode.
  43. Supports SMART auto save timer.
  44. Error logging capability: (0x01) Error logging supported.
  45. General Purpose Logging supported.
  46. Short self-test routine
  47. recommended polling time: ( 2) minutes.
  48. Extended self-test routine
  49. recommended polling time: ( 78) minutes.
  50. SCT capabilities: (0x003f) SCT Status supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 0
  58. 2 Throughput_Performance 0x0026 056 056 000 Old_age Always - 4232
  59. 3 Spin_Up_Time 0x0023 094 093 025 Pre-fail Always - 1976
  60. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 85
  61. 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
  63. 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
  64. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 56
  65. 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
  66. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 16
  67. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 83
  68. 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 9
  69. 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
  70. 194 Temperature_Celsius 0x0002 064 056 000 Old_age Always - 31 (Lifetime Min/Max 13/44)
  71. 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
  72. 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
  73. 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0
  74. 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
  75. 199 UDMA_CRC_Error_Count 0x0036 099 099 000 Old_age Always - 888
  76. 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 22
  77. 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 16
  78. 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 1613
  79.  
  80. SMART Error Log Version: 1
  81. ATA Error Count: 394 (device log contains only the most recent five errors)
  82. CR = Command Register [HEX]
  83. FR = Features Register [HEX]
  84. SC = Sector Count Register [HEX]
  85. SN = Sector Number Register [HEX]
  86. CL = Cylinder Low Register [HEX]
  87. CH = Cylinder High Register [HEX]
  88. DH = Device/Head Register [HEX]
  89. DC = Device Command Register [HEX]
  90. ER = Error register [HEX]
  91. ST = Status register [HEX]
  92. Powered_Up_Time is measured from power on, and printed as
  93. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  94. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  95.  
  96. Error 394 occurred at disk power-on lifetime: 51 hours (2 days + 3 hours)
  97. When the command that caused the error occurred, the device was active or idle.
  98.  
  99. After command completion occurred, registers were:
  100. ER ST SC SN CL CH DH
  101. -- -- -- -- -- -- --
  102. 84 51 00 00 00 00 a0
  103.  
  104. Commands leading to the command that caused the error were:
  105. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  106. -- -- -- -- -- -- -- -- ---------------- --------------------
  107. ec 00 00 00 00 00 a0 02 00:00:00.199 IDENTIFY DEVICE
  108. 29 03 01 00 00 00 e0 02 00:00:00.199 READ MULTIPLE EXT
  109. ef 03 0c 01 00 00 a0 02 00:00:00.198 SET FEATURES [Set transfer mode]
  110. c6 00 10 01 00 00 a0 02 00:00:00.198 SET MULTIPLE MODE
  111. 91 00 3f 01 00 00 af 02 00:00:00.198 INITIALIZE DEVICE PARAMETERS [OBS-6]
  112.  
  113. Error 393 occurred at disk power-on lifetime: 51 hours (2 days + 3 hours)
  114. When the command that caused the error occurred, the device was active or idle.
  115.  
  116. After command completion occurred, registers were:
  117. ER ST SC SN CL CH DH
  118. -- -- -- -- -- -- --
  119. 84 51 00 00 00 00 a0
  120.  
  121. Commands leading to the command that caused the error were:
  122. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  123. -- -- -- -- -- -- -- -- ---------------- --------------------
  124. ec 00 00 00 00 00 a0 02 00:00:00.188 IDENTIFY DEVICE
  125. ec 00 00 00 00 00 a0 02 00:00:00.188 IDENTIFY DEVICE
  126. 29 03 01 00 00 00 e0 02 00:00:00.188 READ MULTIPLE EXT
  127. ef 03 0c 01 00 00 a0 02 00:00:00.187 SET FEATURES [Set transfer mode]
  128. c6 d8 10 01 00 00 a0 02 00:00:00.187 SET MULTIPLE MODE
  129.  
  130. Error 392 occurred at disk power-on lifetime: 51 hours (2 days + 3 hours)
  131. When the command that caused the error occurred, the device was active or idle.
  132.  
  133. After command completion occurred, registers were:
  134. ER ST SC SN CL CH DH
  135. -- -- -- -- -- -- --
  136. 84 51 00 00 00 00 a0
  137.  
  138. Commands leading to the command that caused the error were:
  139. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  140. -- -- -- -- -- -- -- -- ---------------- --------------------
  141. ec 00 00 00 00 00 a0 02 00:00:00.115 IDENTIFY DEVICE
  142. c6 03 00 00 00 00 a0 02 00:00:00.115 SET MULTIPLE MODE
  143. 24 03 08 02 00 00 e0 02 00:00:00.115 READ SECTOR(S) EXT
  144. c6 03 00 00 00 00 a0 02 00:00:00.114 SET MULTIPLE MODE
  145. 24 03 08 02 00 00 e0 02 00:00:00.114 READ SECTOR(S) EXT
  146.  
  147. Error 391 occurred at disk power-on lifetime: 51 hours (2 days + 3 hours)
  148. When the command that caused the error occurred, the device was active or idle.
  149.  
  150. After command completion occurred, registers were:
  151. ER ST SC SN CL CH DH
  152. -- -- -- -- -- -- --
  153. 84 51 00 00 00 00 a0
  154.  
  155. Commands leading to the command that caused the error were:
  156. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  157. -- -- -- -- -- -- -- -- ---------------- --------------------
  158. ec 00 00 00 00 00 a0 02 00:00:00.102 IDENTIFY DEVICE
  159. ec 00 00 00 00 00 a0 02 00:00:00.102 IDENTIFY DEVICE
  160. 24 03 01 00 00 00 e0 02 00:00:00.102 READ SECTOR(S) EXT
  161. ef 03 0c 01 00 00 a0 02 00:00:00.101 SET FEATURES [Set transfer mode]
  162. 91 03 3f 01 00 00 af 02 00:00:00.101 INITIALIZE DEVICE PARAMETERS [OBS-6]
  163.  
  164. Error 390 occurred at disk power-on lifetime: 51 hours (2 days + 3 hours)
  165. When the command that caused the error occurred, the device was active or idle.
  166.  
  167. After command completion occurred, registers were:
  168. ER ST SC SN CL CH DH
  169. -- -- -- -- -- -- --
  170. 84 51 00 00 00 00 a0
  171.  
  172. Commands leading to the command that caused the error were:
  173. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  174. -- -- -- -- -- -- -- -- ---------------- --------------------
  175. ec 00 00 00 00 00 a0 02 00:00:00.052 IDENTIFY DEVICE
  176. ec 00 00 00 00 00 a0 02 00:00:00.052 IDENTIFY DEVICE
  177. ef 03 0c 01 00 00 a0 02 00:00:00.052 SET FEATURES [Set transfer mode]
  178. c6 00 10 01 00 00 a0 02 00:00:00.052 SET MULTIPLE MODE
  179. 91 00 3f 01 00 00 af 02 00:00:00.052 INITIALIZE DEVICE PARAMETERS [OBS-6]
  180.  
  181. SMART Self-test log structure revision number 1
  182. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  183. # 1 Extended offline Completed without error 00% 55 -
  184. # 2 Extended offline Completed without error 00% 54 -
  185. # 3 Extended offline Interrupted (host reset) 90% 44 -
  186. # 4 Extended offline Aborted by host 90% 44 -
  187.  
  188. SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1
  189. SMART Selective self-test log data structure revision number 0
  190. Warning: ATA Specification requires selective self-test log data structure revision number = 1
  191. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  192. 1 0 0 Completed [00% left] (0-65535)
  193. 2 0 0 Not_testing
  194. 3 0 0 Not_testing
  195. 4 0 0 Not_testing
  196. 5 0 0 Not_testing
  197. Selective self-test flags (0x0):
  198. After scanning selected spans, do NOT read-scan remainder of disk.
  199. If Selective self-test is pending on power-up, resume after 0 minute delay.
  200.  
  201. ubuntu@ubuntu:~$