  1. smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.5.4-vs2.3.4.3] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: SAMSUNG SpinPoint F4 EG (AFT)
  6. Device Model: SAMSUNG HD204UI
  7. Serial Number: S2H7JX0C700519
  8. LU WWN Device Id: 5 0000f0 0700b1905
  9. Firmware Version: 1AQ10001
  10. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: 8
  14. ATA Standard is: ATA-8-ACS revision 6
  15. Local Time is: Thu Nov 15 11:20:34 2012 EST
  16.  
  17. ==> WARNING: Using smartmontools or hdparm with this
  18. drive may result in data loss due to a firmware bug.
  19. ****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
  20. Buggy and fixed firmware report same version number!
  21. See the following web pages for details:
  22. http://www.samsung.com/global/business/hdd/faqView.do?b2b_bbs_msg_id=386
  23. http://sourceforge.net/apps/trac/smartmontools/wiki/SamsungF4EGBadBlocks
  24.  
  25. SMART support is: Available - device has SMART capability.
  26. SMART support is: Enabled
  27.  
  28. === START OF READ SMART DATA SECTION ===
  29. SMART overall-health self-assessment test result: PASSED
  30.  
  31. General SMART Values:
  32. Offline data collection status: (0x82) Offline data collection activity
  33. was completed without error.
  34. Auto Offline Data Collection: Enabled.
  35. Self-test execution status: ( 121) The previous self-test completed having
  36. the read element of the test failed.
  37. Total time to complete Offline
  38. data collection: (20220) seconds.
  39. Offline data collection
  40. capabilities: (0x5b) SMART execute Offline immediate.
  41. Auto Offline data collection on/off support.
  42. Suspend Offline collection upon new
  43. command.
  44. Offline surface scan supported.
  45. Self-test supported.
  46. No Conveyance Self-test supported.
  47. Selective Self-test supported.
  48. SMART capabilities: (0x0003) Saves SMART data before entering
  49. power-saving mode.
  50. Supports SMART auto save timer.
  51. Error logging capability: (0x01) Error logging supported.
  52. General Purpose Logging supported.
  53. Short self-test routine
  54. recommended polling time: ( 2) minutes.
  55. Extended self-test routine
  56. recommended polling time: ( 255) minutes.
  57. SCT capabilities: (0x003f) SCT Status supported.
  58. SCT Error Recovery Control supported.
  59. SCT Feature Control supported.
  60. SCT Data Table supported.
  61.  
  62. SMART Attributes Data Structure revision number: 16
  63. Vendor Specific SMART Attributes with Thresholds:
  64. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  65. 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 697
  66. 2 Throughput_Performance 0x0026 055 055 000 Old_age Always - 18500
  67. 3 Spin_Up_Time 0x0023 067 066 025 Pre-fail Always - 10126
  68. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 404
  69. 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
  70. 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
  71. 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
  72. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1859
  73. 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
  74. 11 Calibration_Retry_Count 0x0032 252 252 000 Old_age Always - 0
  75. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 15
  76. 181 Program_Fail_Cnt_Total 0x0022 095 095 000 Old_age Always - 127478518
  77. 191 G-Sense_Error_Rate 0x0022 252 252 000 Old_age Always - 0
  78. 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
  79. 194 Temperature_Celsius 0x0002 061 046 000 Old_age Always - 39 (Min/Max 14/54)
  80. 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
  81. 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
  82. 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 1
  83. 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 1
  84. 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0
  85. 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 12
  86. 223 Load_Retry_Count 0x0032 252 252 000 Old_age Always - 0
  87. 225 Load_Cycle_Count 0x0032 083 083 000 Old_age Always - 177138
  88.  
  89. SMART Error Log Version: 1
  90. ATA Error Count: 1754 (device log contains only the most recent five errors)
  91. CR = Command Register [HEX]
  92. FR = Features Register [HEX]
  93. SC = Sector Count Register [HEX]
  94. SN = Sector Number Register [HEX]
  95. CL = Cylinder Low Register [HEX]
  96. CH = Cylinder High Register [HEX]
  97. DH = Device/Head Register [HEX]
  98. DC = Device Command Register [HEX]
  99. ER = Error register [HEX]
  100. ST = Status register [HEX]
  101. Powered_Up_Time is measured from power on, and printed as
  102. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  103. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  104.  
  105. Error 1754 occurred at disk power-on lifetime: 1854 hours (77 days + 6 hours)
  106. When the command that caused the error occurred, the device was active or idle.
  107.  
  108. After command completion occurred, registers were:
  109. ER ST SC SN CL CH DH
  110. -- -- -- -- -- -- --
  111. 40 51 08 58 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000058 = 88
  112.  
  113. Commands leading to the command that caused the error were:
  114. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  115. -- -- -- -- -- -- -- -- ---------------- --------------------
  116. c8 00 40 20 00 00 e0 00 00:29:28.979 READ DMA
  117. 25 00 08 a0 88 e0 e0 00 00:29:28.979 READ DMA EXT
  118. 25 00 08 00 88 e0 e0 00 00:29:28.979 READ DMA EXT
  119. 25 00 08 70 87 e0 e0 00 00:29:28.979 READ DMA EXT
  120. 25 00 08 e8 85 e0 e0 00 00:29:28.979 READ DMA EXT
  121.  
  122. Error 1753 occurred at disk power-on lifetime: 1845 hours (76 days + 21 hours)
  123. When the command that caused the error occurred, the device was active or idle.
  124.  
  125. After command completion occurred, registers were:
  126. ER ST SC SN CL CH DH
  127. -- -- -- -- -- -- --
  128. 40 51 08 58 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000058 = 88
  129.  
  130. Commands leading to the command that caused the error were:
  131. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  132. -- -- -- -- -- -- -- -- ---------------- --------------------
  133. c8 00 40 20 00 00 e0 00 00:28:27.622 READ DMA
  134. 25 00 08 a0 88 e0 e0 00 00:28:27.622 READ DMA EXT
  135. 25 00 08 00 88 e0 e0 00 00:28:27.622 READ DMA EXT
  136. 25 00 30 28 88 3d e0 00 00:28:27.622 READ DMA EXT
  137. 25 00 20 08 88 3d e0 00 00:28:27.622 READ DMA EXT
  138.  
  139. Error 1752 occurred at disk power-on lifetime: 1845 hours (76 days + 21 hours)
  140. When the command that caused the error occurred, the device was active or idle.
  141.  
  142. After command completion occurred, registers were:
  143. ER ST SC SN CL CH DH
  144. -- -- -- -- -- -- --
  145. 40 51 08 58 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000058 = 88
  146.  
  147. Commands leading to the command that caused the error were:
  148. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  149. -- -- -- -- -- -- -- -- ---------------- --------------------
  150. c8 00 40 20 00 00 e0 00 00:28:27.154 READ DMA
  151. 25 00 08 a0 88 e0 e0 00 00:28:27.154 READ DMA EXT
  152. 25 00 08 00 88 e0 e0 00 00:28:27.154 READ DMA EXT
  153. 25 00 08 90 29 94 e0 00 00:28:27.154 READ DMA EXT
  154. 25 00 08 d8 28 94 e0 00 00:28:27.154 READ DMA EXT
  155.  
  156. Error 1751 occurred at disk power-on lifetime: 1845 hours (76 days + 21 hours)
  157. When the command that caused the error occurred, the device was active or idle.
  158.  
  159. After command completion occurred, registers were:
  160. ER ST SC SN CL CH DH
  161. -- -- -- -- -- -- --
  162. 40 51 08 58 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000058 = 88
  163.  
  164. Commands leading to the command that caused the error were:
  165. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  166. -- -- -- -- -- -- -- -- ---------------- --------------------
  167. c8 00 40 20 00 00 e0 00 00:28:26.925 READ DMA
  168. c8 00 20 00 00 00 e0 00 00:28:26.925 READ DMA
  169. 25 00 08 a0 88 e0 e0 00 00:28:26.925 READ DMA EXT
  170. c8 00 02 08 18 a0 e0 00 00:28:26.925 READ DMA
  171. c8 00 02 08 18 a0 e0 00 00:28:26.925 READ DMA
  172.  
  173. Error 1750 occurred at disk power-on lifetime: 1845 hours (76 days + 21 hours)
  174. When the command that caused the error occurred, the device was active or idle.
  175.  
  176. After command completion occurred, registers were:
  177. ER ST SC SN CL CH DH
  178. -- -- -- -- -- -- --
  179. 40 51 08 58 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000058 = 88
  180.  
  181. Commands leading to the command that caused the error were:
  182. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  183. -- -- -- -- -- -- -- -- ---------------- --------------------
  184. c8 00 40 20 00 00 e0 00 00:28:26.923 READ DMA
  185. c8 00 20 00 00 00 e0 00 00:28:26.923 READ DMA
  186. 25 00 08 a0 88 e0 e0 00 00:28:26.923 READ DMA EXT
  187. c8 00 02 08 18 a0 e0 00 00:28:26.923 READ DMA
  188. c8 00 02 08 18 a0 e0 00 00:28:26.923 READ DMA
  189.  
  190. SMART Self-test log structure revision number 1
  191. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  192. # 1 Extended offline Completed: read failure 90% 1819 88
  193. # 2 Short offline Completed: read failure 90% 1793 88
  194. # 3 Short offline Completed: read failure 90% 1688 88
  195. # 4 Short offline Completed: read failure 90% 1672 88
  196. # 5 Short offline Completed: read failure 90% 1340 88
  197. # 6 Short offline Completed: read failure 90% 1316 88
  198. # 7 Extended offline Completed: read failure 90% 1292 88
  199. # 8 Short offline Completed: read failure 90% 1245 88
  200. # 9 Short offline Completed: read failure 90% 1229 88
  201. #10 Short offline Completed: read failure 90% 1213 88
  202. #11 Short offline Completed: read failure 90% 1198 88
  203. #12 Short offline Completed: read failure 90% 1177 88
  204. #13 Extended offline Completed: read failure 90% 1161 88
  205. #14 Short offline Completed: read failure 90% 1145 88
  206. #15 Short offline Completed: read failure 90% 1122 88
  207. #16 Short offline Completed: read failure 90% 1106 88
  208. #17 Short offline Completed: read failure 90% 1088 88
  209. #18 Short offline Completed: read failure 90% 1072 88
  210. #19 Extended offline Completed: read failure 90% 1058 88
  211. #20 Short offline Completed: read failure 90% 1042 88
  212. #21 Short offline Completed: read failure 90% 1026 88
  213.  
  214. Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run
  215. SMART Selective self-test log data structure revision number 0
  216. Note: revision number not 1 implies that no selective self-test has ever been run
  217. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  218. 1 0 0 Completed_read_failure [90% left] (0-65535)
  219. 2 0 0 Not_testing
  220. 3 0 0 Not_testing
  221. 4 0 0 Not_testing
  222. 5 0 0 Not_testing
  223. Selective self-test flags (0x0):
  224. After scanning selected spans, do NOT read-scan remainder of disk.
  225. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement