  1. smartctl -d sat -a /dev/sdb
  2. smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.3.8-1.fc16.x86_64] (local build)
  3. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Device Model: WDC WD30EURS-63R8UY0
  7. Serial Number: WD-WCAWZ0976011
  8. LU WWN Device Id: 5 0014ee 20611fc5e
  9. Firmware Version: 80.00A80
  10. User Capacity: 3,000,592,982,016 bytes [3.00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Device is: Not in smartctl database [for details use: -P showall]
  13. ATA Version is: 8
  14. ATA Standard is: Exact ATA specification draft version not indicated
  15. Local Time is: Sun Jun 17 07:58:06 2012 CEST
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART STATUS RETURN: incomplete response, ATA output registers missing
  21. SMART overall-health self-assessment test result: PASSED
  22. Warning: This result is based on an Attribute check.
  23.  
  24. General SMART Values:
  25. Offline data collection status: (0x00) Offline data collection activity
  26. was never started.
  27. Auto Offline Data Collection: Disabled.
  28. Self-test execution status: ( 0) The previous self-test routine completed
  29. without error or no self-test has ever
  30. been run.
  31. Total time to complete Offline
  32. data collection: (51660) seconds.
  33. Offline data collection
  34. capabilities: (0x7b) SMART execute Offline immediate.
  35. Auto Offline data collection on/off support.
  36. Suspend Offline collection upon new
  37. command.
  38. Offline surface scan supported.
  39. Self-test supported.
  40. Conveyance Self-test supported.
  41. Selective Self-test supported.
  42. SMART capabilities: (0x0003) Saves SMART data before entering
  43. power-saving mode.
  44. Supports SMART auto save timer.
  45. Error logging capability: (0x01) Error logging supported.
  46. General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time: ( 2) minutes.
  49. Extended self-test routine
  50. recommended polling time: ( 255) minutes.
  51. Conveyance self-test routine
  52. recommended polling time: ( 5) minutes.
  53. SCT capabilities: (0x3035) SCT Status supported.
  54. SCT Feature Control supported.
  55. SCT Data Table supported.
  56.  
  57. SMART Attributes Data Structure revision number: 16
  58. Vendor Specific SMART Attributes with Thresholds:
  59. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  60. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
  61. 3 Spin_Up_Time 0x0027 226 142 021 Pre-fail Always - 5700
  62. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 269
  63. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  64. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  65. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 459
  66. 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  67. 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  68. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 88
  69. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 46
  70. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 222
  71. 194 Temperature_Celsius 0x0022 107 103 000 Old_age Always - 45
  72. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  73. 197 Current_Pending_Sector 0x0032 066 066 000 Old_age Always - 65533
  74. 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
  75. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  76. 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
  77.  
  78. SMART Error Log Version: 1
  79. No Errors Logged
  80.  
  81. SMART Self-test log structure revision number 1
  82. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  83.  
  84.  
  85. SMART Selective self-test log data structure revision number 1
  86. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  87. 1 0 0 Not_testing
  88. 2 0 0 Not_testing
  89. 3 0 0 Not_testing
  90. 4 0 0 Not_testing
  91. 5 0 0 Not_testing
  92. Selective self-test flags (0x0):
  93. After scanning selected spans, do NOT read-scan remainder of disk.
  94. If Selective self-test is pending on power-up, resume after 0 minute delay.