Guest User

Windows Technical Preview Build 9860 x64 / DISM / KB958559

a guest
Nov 23rd, 2014
685
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 2.47 KB | None | 0 0
  1. dism.log:
  2. 2014-11-23 17:30:06, Error DISM DISM Package Manager: PID=2948 TID=3660 Failed opening package. - CDISMPackageManager::Internal_CreatePackageByPath(hr:0x80070307)
  3. 2014-11-23 17:30:06, Error DISM DISM Package Manager: PID=2948 TID=3660 Failed to get the underlying CBS package. - CDISMPackageManager::OpenPackageByPath(hr:0x80070307)
  4. 2014-11-23 17:30:06, Error DISM DISM Package Manager: PID=2948 TID=3660 Failed to open the package at location: "Windows6.1-KB958559-x64-RefreshPkg.cab" - CPackageManagerCLIHandler::ProcessPackagePath(hr:0x80070307)
  5. 2014-11-23 17:30:06, Error DISM DISM Package Manager: PID=2948 TID=3660 Failed while processing command add-package. - CPackageManagerCLIHandler::ExecuteCmdLine(hr:0x80070307)
  6. 2014-11-23 17:30:06, Info DISM DISM Package Manager: PID=2948 TID=3660 Further logs for online package and feature related operations can be found at %WINDIR%\logs\CBS\cbs.log - CPackageManagerCLIHandler::ExecuteCmdLine
  7. 2014-11-23 17:30:06, Error DISM DISM.EXE: DISM Package Manager processed the command line but failed. HRESULT=80070307
  8.  
  9. CBS.log:
  10. 2014-11-23 17:30:06, Info DPX Extraction of file: update.ses failed because it is not present in the container.
  11. 2014-11-23 17:30:06, Info DPX DpxException hr=0x80070002 code=0x020109
  12. 2014-11-23 17:30:06, Info CBS Not able to add file to extract: update.ses [HRESULT = 0x80070002 - ERROR_FILE_NOT_FOUND]
  13. 2014-11-23 17:30:06, Error CBS Can't understand the catalog algorithm in catalog \\?\C:\WINDOWS\CbsTemp\30410554_3181564043\update.cat [HRESULT = 0x80070307 - ERROR_NOT_CAPABLE]
  14. 2014-11-23 17:30:06, Error CBS Failed to verify if mum file \\?\C:\WINDOWS\CbsTemp\30410554_3181564043\update.mum is vouched for by catalog \\?\C:\WINDOWS\CbsTemp\30410554_3181564043\update.cat. [HRESULT = 0x80070307 - ERROR_NOT_CAPABLE]
  15. 2014-11-23 17:30:06, Info CBS Failed to copy manifest: \\?\C:\Users\Remik\AppData\Local\Temp\BECB84B1-1E1E-45AE-B6BB-8EAE47837ABB\update.mum to private store and verify the content. [HRESULT = 0x80070307 - ERROR_NOT_CAPABLE]
  16. 2014-11-23 17:30:06, Info CBS Failed to initialize internal package [HRESULT = 0x80070307 - ERROR_NOT_CAPABLE]
  17. 2014-11-23 17:30:06, Error CBS Failed to create internal package [HRESULT = 0x80070307 - ERROR_NOT_CAPABLE]