  1. debug level is '3'
  2. Checking device (1D6B/0002) (003/001)
  3. - VendorID: 1d6b
  4. - ProductID: 0002
  5. - Manufacturer: unknown
  6. - Product: unknown
  7. - Serial Number: unknown
  8. - Bus: 003
  9. Trying to match device
  10. Device does not match - skipping
  11. Checking device (058F/6362) (001/003)
  12. - VendorID: 058f
  13. - ProductID: 6362
  14. - Manufacturer: unknown
  15. - Product: unknown
  16. - Serial Number: unknown
  17. - Bus: 001
  18. Trying to match device
  19. Device does not match - skipping
  20. Checking device (FFFF/0000) (001/004)
  21. - VendorID: ffff
  22. - ProductID: 0000
  23. - Manufacturer: unknown
  24. - Product: unknown
  25. - Serial Number: unknown
  26. - Bus: 001
  27. Trying to match device
  28. Device matches
  29. Trying megatec protocol...
  30. send: Q1
  31. read: error sending control message: Operation not permitted
  32. blazer_status: short reply
  33. Status read 1 failed
  34. Checking device (1D6B/0002) (003/001)
  35. - VendorID: 1d6b
  36. - ProductID: 0002
  37. - Manufacturer: unknown
  38. - Product: unknown
  39. - Serial Number: unknown
  40. - Bus: 003
  41. Trying to match device
  42. Device does not match - skipping
  43. Checking device (058F/6362) (001/003)
  44. - VendorID: 058f
  45. - ProductID: 6362
  46. - Manufacturer: unknown
  47. - Product: unknown
  48. - Serial Number: unknown
  49. - Bus: 001
  50. Trying to match device
  51. Device does not match - skipping
  52. Checking device (FFFF/0000) (001/004)
  53. - VendorID: ffff
  54. - ProductID: 0000
  55. - Manufacturer: unknown
  56. - Product: 068A
  57. - Serial Number: unknown
  58. - Bus: 001
  59. Trying to match device
  60. Device does not match - skipping
  61. Checking device (8087/0020) (001/002)
  62. - VendorID: 8087
  63. - ProductID: 0020
  64. - Manufacturer: unknown
  65. - Product: unknown
  66. - Serial Number: unknown
  67. - Bus: 001
  68. Trying to match device
  69. Device does not match - skipping
  70. Checking device (1D6B/0002) (001/001)
  71. - VendorID: 1d6b
  72. - ProductID: 0002
  73. - Manufacturer: unknown
  74. - Product: unknown
  75. - Serial Number: unknown
  76. - Bus: 001
  77. Trying to match device
  78. Device does not match - skipping
  79. Checking device (8087/0020) (002/002)
  80. - VendorID: 8087
  81. - ProductID: 0020
  82. - Manufacturer: unknown
  83. - Product: unknown
  84. - Serial Number: unknown
  85. - Bus: 002
  86. Trying to match device
  87. Device does not match - skipping
  88. Checking device (1D6B/0002) (002/001)
  89. - VendorID: 1d6b
  90. - ProductID: 0002
  91. - Manufacturer: unknown
  92. - Product: unknown
  93. - Serial Number: unknown
  94. - Bus: 002
  95. Trying to match device
  96. Device does not match - skipping
  97. No appropriate HID device found
  98. Network UPS Tools - Megatec/Q1 protocol USB driver 0.03 (2.4.1)
  99. blazer_status: short reply
  100. Status read 2 failed
  101. Checking device (1D6B/0002) (003/001)
  102. - VendorID: 1d6b
  103. - ProductID: 0002
  104. - Manufacturer: unknown
  105. - Product: unknown
  106. - Serial Number: unknown
  107. - Bus: 003
  108. Trying to match device
  109. Device does not match - skipping
  110. Checking device (058F/6362) (001/003)
  111. - VendorID: 058f
  112. - ProductID: 6362
  113. - Manufacturer: unknown
  114. - Product: unknown
  115. - Serial Number: unknown
  116. - Bus: 001
  117. Trying to match device
  118. Device does not match - skipping
  119. Checking device (FFFF/0000) (001/004)
  120. - VendorID: ffff
  121. - ProductID: 0000
  122. - Manufacturer:
  123. - Product: 068A
  124. - Serial Number: unknown
  125. - Bus: 001
  126. Trying to match device
  127. Device does not match - skipping
  128. Checking device (8087/0020) (001/002)
  129. - VendorID: 8087
  130. - ProductID: 0020
  131. - Manufacturer: unknown
  132. - Product: unknown
  133. - Serial Number: unknown
  134. - Bus: 001
  135. Trying to match device
  136. Device does not match - skipping
  137. Checking device (1D6B/0002) (001/001)
  138. - VendorID: 1d6b
  139. - ProductID: 0002
  140. - Manufacturer: unknown
  141. - Product: unknown
  142. - Serial Number: unknown
  143. - Bus: 001
  144. Trying to match device
  145. Device does not match - skipping
  146. Checking device (8087/0020) (002/002)
  147. - VendorID: 8087
  148. - ProductID: 0020
  149. - Manufacturer: unknown
  150. - Product: unknown
  151. - Serial Number: unknown
  152. - Bus: 002
  153. Trying to match device
  154. Device does not match - skipping
  155. Checking device (1D6B/0002) (002/001)
  156. - VendorID: 1d6b
  157. - ProductID: 0002
  158. - Manufacturer: unknown
  159. - Product: unknown
  160. - Serial Number: unknown
  161. - Bus: 002
  162. Trying to match device
  163. Device does not match - skipping
  164. No appropriate HID device found
  165. blazer_status: short reply
  166. Status read 3 failed
  167. Trying mustek protocol...
  168. Checking device (1D6B/0002) (003/001)
  169. - VendorID: 1d6b
  170. - ProductID: 0002
  171. - Manufacturer: unknown
  172. - Product: unknown
  173. - Serial Number: unknown
  174. - Bus: 003
  175. Trying to match device
  176. Device does not match - skipping
  177. Checking device (058F/6362) (001/003)
  178. - VendorID: 058f
  179. - ProductID: 6362
  180. - Manufacturer: unknown
  181. - Product: unknown
  182. - Serial Number: unknown
  183. - Bus: 001
  184. Trying to match device
  185. Device does not match - skipping
  186. Checking device (FFFF/0000) (001/004)
  187. - VendorID: ffff
  188. - ProductID: 0000
  189. - Manufacturer: unknown
  190. - Product: 068A
  191. - Serial Number: unknown
  192. - Bus: 001
  193. Trying to match device
  194. Device does not match - skipping
  195. Checking device (8087/0020) (001/002)
  196. - VendorID: 8087
  197. - ProductID: 0020
  198. - Manufacturer: unknown
  199. - Product: unknown
  200. - Serial Number: unknown
  201. - Bus: 001
  202. Trying to match device
  203. Device does not match - skipping
  204. Checking device (1D6B/0002) (001/001)
  205. - VendorID: 1d6b
  206. - ProductID: 0002
  207. - Manufacturer: unknown
  208. - Product: unknown
  209. - Serial Number: unknown
  210. - Bus: 001
  211. Trying to match device
  212. Device does not match - skipping
  213. Checking device (8087/0020) (002/002)
  214. - VendorID: 8087
  215. - ProductID: 0020
  216. - Manufacturer: unknown
  217. - Product: unknown
  218. - Serial Number: unknown
  219. - Bus: 002
  220. Trying to match device
  221. Device does not match - skipping
  222. Checking device (1D6B/0002) (002/001)
  223. - VendorID: 1d6b
  224. - ProductID: 0002
  225. - Manufacturer: unknown
  226. - Product: unknown
  227. - Serial Number: unknown
  228. - Bus: 002
  229. Trying to match device
  230. Device does not match - skipping
  231. No appropriate HID device found
  232. blazer_status: short reply
  233. Status read 1 failed
  234. Checking device (1D6B/0002) (003/001)
  235. - VendorID: 1d6b
  236. - ProductID: 0002
  237. - Manufacturer: unknown
  238. - Product: unknown
  239. - Serial Number: unknown
  240. - Bus: 003
  241. Trying to match device
  242. Device does not match - skipping
  243. Checking device (058F/6362) (001/003)
  244. - VendorID: 058f
  245. - ProductID: 6362
  246. - Manufacturer: unknown
  247. - Product: unknown
  248. - Serial Number: unknown
  249. - Bus: 001
  250. Trying to match device
  251. Device does not match - skipping
  252. Checking device (FFFF/0000) (001/004)
  253. - VendorID: ffff
  254. - ProductID: 0000
  255. - Manufacturer: unknown
  256. - Product: 068A
  257. - Serial Number: unknown
  258. - Bus: 001
  259. Trying to match device
  260. Device does not match - skipping
  261. Checking device (8087/0020) (001/002)
  262. - VendorID: 8087
  263. - ProductID: 0020
  264. - Manufacturer: unknown
  265. - Product: unknown
  266. - Serial Number: unknown
  267. - Bus: 001
  268. Trying to match device
  269. Device does not match - skipping
  270. Checking device (1D6B/0002) (001/001)
  271. - VendorID: 1d6b
  272. - ProductID: 0002
  273. - Manufacturer: unknown
  274. - Product: unknown
  275. - Serial Number: unknown
  276. - Bus: 001
  277. Trying to match device
  278. Device does not match - skipping
  279. Checking device (8087/0020) (002/002)
  280. - VendorID: 8087
  281. - ProductID: 0020
  282. - Manufacturer: unknown
  283. - Product: unknown
  284. - Serial Number: unknown
  285. - Bus: 002
  286. Trying to match device
  287. Device does not match - skipping
  288. Checking device (1D6B/0002) (002/001)
  289. - VendorID: 1d6b
  290. - ProductID: 0002
  291. - Manufacturer: unknown
  292. - Product: unknown
  293. - Serial Number: unknown
  294. - Bus: 002
  295. Trying to match device
  296. Device does not match - skipping
  297. No appropriate HID device found
  298. blazer_status: short reply
  299. Status read 2 failed
  300. Checking device (1D6B/0002) (003/001)
  301. - VendorID: 1d6b
  302. - ProductID: 0002
  303. - Manufacturer: unknown
  304. - Product: unknown
  305. - Serial Number: unknown
  306. - Bus: 003
  307. Trying to match device
  308. Device does not match - skipping
  309. Checking device (058F/6362) (001/003)
  310. - VendorID: 058f
  311. - ProductID: 6362
  312. - Manufacturer: unknown
  313. - Product: unknown
  314. - Serial Number: unknown
  315. - Bus: 001
  316. Trying to match device
  317. Device does not match - skipping
  318. Checking device (FFFF/0000) (001/004)
  319. - VendorID: ffff
  320. - ProductID: 0000
  321. - Manufacturer: unknown
  322. - Product: unknown
  323. - Serial Number: unknown
  324. - Bus: 001
  325. Trying to match device
  326. Device matches
  327. send: QS
  328. read: QS
  329. blazer_status: short reply
  330. Status read 3 failed
  331. Trying megatec/old protocol...
  332. send: D
  333. read: D
  334. blazer_status: short reply
  335. Status read 1 failed
  336. send: D
  337. read: D
  338. blazer_status: short reply
  339. Status read 2 failed
  340. send: D
  341. read: D
  342. blazer_status: short reply
  343. Status read 3 failed
  344. No supported UPS detected